首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
Based on the characteristics of synchronous fluorescence spectroscopy (SFS), a new method with high sensitivity and selectivity was developed for rapid determination of silver ion with functional cadmium sulphide (CdS) nanoparticles as a fluorescence probe. When Δλ (λem − λex) = 215 nm, maximum synchronous fluorescence is produced at 304 nm. Under optimal conditions, functional cadmium sulphide displayed a calibration response for silver ion over a wide concentration range from 0.8 × 10−10 to 1.5 × 10−8 mol L−1. The limit of detection was 0.4 × 10−10 mol L−1 and the relative standard deviation of seven replicate measurements for the lowest concentration (0.8 × 10−10 mol L−1) was 2.8%. Compared with several fluorescence methods, the proposed method had a wider linear range and improved the sensitivity. Furthermore, the concentration dependence of the synchronous fluorescence intensity is effectively described by a Langmuir-type binding isotherm.  相似文献   

2.
A sensitive FIA method was developed for the selective determination of formaldehyde in alcoholic beverages. This method is based on the reaction of Fluoral-P (4-amine-3-pentene-2-one) with formaldehyde, leading to the formation of 3,5-diacetyl-1,4-dihydrolutidine (DDL), which fluoresces at λex = 410 nm and λem = 510 nm. The analytical parameters were optimized by the response surface method using the Box-Behnken design. The proposed flow injection system allowed for the determination of up to 3.33 × 10−5 mol L−1 of formaldehyde with R.S.D. < 2.5% and a detection limit of 3.1 ng mL−1. The method was successfully applied to determine formaldehyde in alcoholic beverages, without requiring any sample pretreatment, and the results agreed with the reference at a 95% confidence level by paired t-test. In the optimized condition, the FIA system proved able to analyze up to 60 samples/h.  相似文献   

3.
The synthesis, properties and applications of a novel boronate-functioned styryl dye, BSD, as a colorimetric sensor for hydrogen peroxide is presented. The dye displayed remarkable color change from colorless (λmax = 391 nm) to deep red (λmax = 522 nm) in the presence of H2O2 and the behavior could be rationalized by the chemoselective H2O2-mediated transformation of arylboronate to phenolate, resulting in the release of the merocyanine dye which featured with strong intramolecular charge transfer (ICT) absorption band. The absorption increment of merocyanine at λmax = 522 nm (? = 87000 L mol−1 cm−1) is linear with the concentration of H2O2 in the range of 1.0 × 10−7-2.5 × 10−5 mol L−1 with the detection limit of 6.8 × 10−8 mol L−1 under optimum conditions. There is almost no interference by other species that commonly exist due to the specific deprotection of H2O2 towards arylboronate group on BSD. The chromogenic sensor has been applied to the detection of trace amounts of hydrogen peroxide in rain water.  相似文献   

4.
Fluorescence and terbium-sensitised luminescence properties of new quinolone garenoxacin have been studied. The fluorimetric method allows the determination of 0.060-0.600 μg ml−1 of garenoxacin in aqueous solution containing HCl/KCl buffer (pH 1.5) with λexc=282 nm and λem=421 nm. Micellar-enhanced fluorescence was also studied, leading to a higher than 400% increase in analytical signal in presence of 12 mM sodium dodecyl sulphate (SDS), allowing the determination of 0.020-0.750 μg ml−1 of garenoxacin. The terbium-sensitised luminescence method allows the determination of 0.100-1.500 μg ml−1 of garenoxacin in 12 mM SDS solution containing 0.08 M acetic acid/sodium acetate buffer (pH 4.1) and 7.5 mM Na2SO3 (chemical deoxygenation agent), with λexc=281 nm and λem=546 nm. Relative standard deviation (R.S.D.) values for the three methods were in the range 1.0-2.0%. The proposed procedures have been applied to the determination of garenoxacin in spiked human urine and serum.  相似文献   

5.
A bifurcated optical fiber chemical sensor for continuous monitoring of bisphenol A (BPA) has been proposed based on the fluorescence quenching (λex/λem = 286/390 nm) of pyrene/dimethyl β-cyclodextrin (HDM-β-CD) supramolecular complex immobilized in a plasticized poly(vinyl chloride) (PVC) membrane, in which pyrene served as a sensitive fluorescence indicator probe. The decrease of the fluorescence intensity of pyrene/HDM-β-CD complex upon the addition of BPA was attributed to the displacement of pyrene by BPA, which has been utilized as the basis of the fabrication of a BPA-sensitive fluorescence sensor. The response mechanism of the sensor was discussed in detail. The sensor exhibited a dynamic detection range from 7.90 × 10−8 to 1.66 × 10−5 mol L−1 with a detection limit of 7.00 × 10−8 mol L−1, and showed excellent reproducibility, reversibility, selectivity, and lifetime. The proposed sensor was successfully used for the determination of BPA in water samples and landfill leachate.  相似文献   

6.
A high-performance liquid chromatographic method has been developed for the determination in human plasma of the specific serotonin reuptake inhibitor (SSRI) antidepressant paroxetine and its three main metabolites (M1, M2, M3). Fluorescence detection was used, exciting at λ = 294 nm and monitoring emission at λ = 330 nm for paroxetine (λexc = 280 nm, λem = 330 nm for M1 and M2; λexc = 268 nm, λem = 290 nm for M3). Separation was obtained on a reversed-phase C18 column using a mobile phase composed of 66.7% aqueous phosphate at pH 2.5 and 33.3% acetonitrile. Imipramine (λexc = 252 nm, λem = 390 nm) was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C8 cartridges (50 mg, 1 mL). The calibration curves were linear over a working range of 2.5-100 ng mL−1 for paroxetine and of 5-100 ng mL−1 for all metabolites. The limit of detection (LOD) was 1.2 ng mL−1 for PRX and 2.0 ng mL−1 for the metabolites. The method was applied with success to plasma samples from depressed patients undergoing treatment with paroxetine. Hence, the method seems to be suitable for the therapeutic drug monitoring of paroxetine and its main metabolites in depressed patients’ plasma.  相似文献   

7.
A novel flow injection analysis (FIA) system based on liquid-liquid microextraction and fluorimetric determination was developed for the determination of traces of the Zn2+ ion using 5-(8-hydroxy-2-quinolinylmethyl)-2,8-dithia-5-aza-2,6-pyridinophane (L) as a sensitive and selective fluorimetric sensor, with λex = 373 nm and λem = 530 nm, and hexanol as the extracting organic solvent. In the designed FIA system, the phase separation takes place via gravitation forces in the absence of any segmenter. The influence of pH and ionic strength of the solution, amount of ligand, nature of counter ion, volume of organic solvent, extraction time and coil length was investigated. Under optimized experimental conditions, the calibration curve found to be liner over a concentration range of 0.025-4.53 μg mL−1 (R2 = 0.9951) with a limit of detection of 2.3 ng mL−1. The enrichment factor was 45 and relative standard deviation for 7 replicate determinations was 2.43%. The method is very fast and uses low levels of organic solvents. The proposed method was applied successfully to the determination of zinc(II) in human hair, human serum and two inorganic sludge samples.  相似文献   

8.
A new, simple and highly sensitive method for spectrofluorimetric determination of amiloride (AMI) and furosemide (FUR) in pharmaceuticals is presented. The proposed method is based on the separation of AMI from FUR by solid-phase extraction using a nylon membrane, followed by spectrofluorimetric determination of both drugs, on the solid surface and the filtered aqueous solution, respectively. AMI shows low native fluorescence, but its separation-preconcentration by immobilization (solid-phase extraction) on nylon membrane surface provides a considerable enhancement in fluorescence intensity. The fluorescence determination is carried out at λex = 237, λem = 415 nm for FUR; and λex = 365, λem = 406 nm for AMI. The calibration graphs are linear in the range 3.20 × 10−4 to 0.8 μg mL−1and 1.33 × 10−3 to 4.0 μg mL−1, for AMI and FUR, respectively, with a detection limit of 9.62 × 10−5 and 4.01 × 10−4 μg mL−1 (S/N = 3). The commonly found excipients in commercial pharmaceutical formulations do not interfere. The developed method is successfully applied to the determination of both drugs in pharmaceutical formulations.  相似文献   

9.
Zisiou EP  Pinto PC  Saraiva ML  Siquet C  Lima JL 《Talanta》2005,68(2):226-230
A sensitive sequential injection analysis (SIA) methodology for the fluorimetric determination of naproxen is proposed. The developed automatic analytical procedure is based on the complexation of naproxen with β-cyclodextrin (β-CD) yielding an enhanced fluorimetric signal (λex = 280 nm, λem = 356 nm).Linear calibration plots were obtained for naproxen concentrations up to 1 × 10−5 mol l−1. The developed methodology exhibited a good precision, with a R.S.D. < 2.1% (n = 15). The detection limit of the determination was 1.9 × 10−7 mol l−1 with a sampling rate of about 70 h−1. The automatic method was applied to the determination of naproxen in pharmaceutical formulations. The obtained results were compared with those furnished by the reference procedure and the relative deviations were lower than 3.6%. No interference was found from the excipients usually used in solid pharmaceutical formulations.  相似文献   

10.
Passos ML  Saraiva ML  Santos JL  Reis S  Lúcio M  Lima JL 《Talanta》2011,84(5):1309-1313
According to the current demands of environmentally friendly analytical chemistry and with a view to achieving lower reagent consumption with improved analytical performance, an automatic methodology composed of a photoreactor and fluorimetric detection (λexc = 287 nm, λem = 378 nm) was developed. To this end, a sequential injection analysis (SIA) system was developed for indomethacin determination using ultra-violet (UV) light which promotes an increase in the fluorescence of indomethacin. This increase in sensitivity makes it possible to apply this methodology to a dissolution test and to determine indomethacin in pharmaceutical formulations.The calibration graph for indomethacin was linear between 4.10 × 10−6 and 9.00 × 10−5 mol L−1and the detection limit was 1.23 × 10−6 mol L−1. The method was proven to be reproducible with a R.S.D. < 5% and sampling rate of approximately 20 per hour. The potential effect of several compounds commonly used as excipients on analytical signals was studied and no interfering effect was observed. Statistical evaluation at the 95% confidence level showed good agreement between the results obtained for the pharmaceutical samples with both the SIA system and comparison batch procedures.  相似文献   

11.
Tang B  Wang X  Wang G  Yu C  Chen Z 《Talanta》2006,69(1):113-120
An indirect spectrofluorimetric method with high sensitivity and selectivity was developed for the determination of antifungal drug: tolnaftate (TNF), depending on the supramolecualr multirecognition interaction among the anionic surfactant sodium laurylsulfate (SLS), β-cyclodextrin (β-CD) and β-naphthol (ROH). The mechanism of the inclusion was studied and discussed by means of fluorescence spectrum, infra-red spectrograms and 1HNMR spectroscopy. Results showed that the naphthalene ring of ROH and the hydrophobic hydrocarbon chain of SLS were included into the β-CD's cavity to form a ROH:SLS:β-CD ternary inclusion complex with stoichiometry of 1:1:1 at room temperature, which provided effective protection for the excited state of ROH. At λex/λem = 273/360 nm, the fluorescence intensity was linear over a tolnaftate concentration range of 2.46 × 10−9 to 2.10 × 10−6 mol L−1. The detection limit and relative standard deviation was 7.50 × 10−10 mol L−1 and 1.4%, respectively. The interference of 31 foreign substances was slight. The proposed method had been successfully applied to the determination of tolnaftate in artificial mixed samples with almost quantitative recovery.  相似文献   

12.
A new, simple and sensitive spectrofluorimetric method for the determination of salicylic acid (λex = 315 nm, λem = 408 nm) using As(III) as a sensitizing reagent has been investigated by measuring the increase of fluorescence intensity of salicylic acid due to the complexation of As(III)-salicylic acid in presence of sodium dodecyl sulfate (SDS) 10−3 M. Under optimum conditions, a significant relationship was obtained between the fluorescence intensity and salicylic acid concentration. A linear calibration curve was obtained in the range 13.8-13812 μg l−1 with product-moment correlation coefficient (R) 0.99985 and detection limit 4.2 μg l−1. The R.S.D. is 2.35% (n = 5).The method was applied successfully to the determination of salicylic acid in human serum.  相似文献   

13.
Li YS  Gao XF 《Analytica chimica acta》2007,588(1):140-146
A novel method for the determination of ethanol in tequila based on the immobilized enzyme fluorescence capillary analysis (IE-EFCA) has been proposed. Alcohol dehydrogenase (ADH) was immobilized in inner surface of a capillary and an immobilized enzyme capillary bioreactor (IE-ECBR) was formed. After nicotinamide adenine dinucleotide (NAD+) as an oxidizer is mixed with alcohol sample solution, it was sucked into the IE-ECBR. The fluorescence intensity of the mixed solution in the IE-ECBR was detected at λex = 350 nm and λem = 459 nm. The experimental conditions are as follows: The reaction time is 20 min; temperature is 40 °C; the concentrations of phosphate buffer solution (pH 7.5) and NAD+ are 0.1 mol L−1 and 5 mmol L−1, respectively; immobilization concentration of ADH is 10 U L−1. The determination range of ethanol is 2.0-15.0 g L−1 (F = 10.44C + 6.6002, r > 0.9958); its detection limit is 1.11 g L−1; and relative standard deviation is 1.9%. IE-EFCA method is applicable for the determination of the samples containing alcohol in medicine, industry and environment.  相似文献   

14.
Tang B  Zhang L  Xu KH 《Talanta》2006,68(3):876-882
A new kind of near-infrared fluorescence agent, tricarbochlorocyanine dye (Cy.7.Cl), had been synthesized in house and used for near-infrared spectrofluorimetric determination of hydrogen peroxide (H2O2) by flow injection analysis (FIA) for the first time. The oxidation reaction of Cy.7.Cl with H2O2 occurred under the catalysis of horseradish peroxidase (HRP) and it was studied in detail. The possible reaction mechanism was discussed. Under optimal experimental conditions, fluorescence from Cy.7.Cl displayed excitation and emission maxima (ex/em) at 780 and 800 nm, respectively. The two linear working ranges were 1.86 × 10−7 to 4.11 × 10−7 mol L−1 and 4.11 × 10−7 to 7.19 × 10−6 mol L−1, respectively. The detection limit was 5.58 × 10−8 mol L−1 of H2O2. The effect of interferences was studied. The proposed method was successfully applied to the determination of hydrogen peroxide in rainwater, serum and plant samples.  相似文献   

15.
Different extraction and clean-up techniques used before HPLC analysis were compared in order to obtain a reliable method for the quantitative determination of zearalenone (ZEA) and α-zearalenol (α-ZOL) in animal feed. Immunoaffinity clean-up was compared to C18 and Florisil column clean-up. Extracted samples were analysed by reversed-phase HPLC with fluorescence detection (λex=274 nm, λem=440 nm). A mobile phase of acetonitrile:water (50:50 (v/v)) and a flow-rate of 1.0 ml min−1 resulted in a good separation between ZEA and α-ZOL. Using immunoaffinity clean-up the linear range was between 25 and 600 μg kg−1 for ZEA and α-ZOL in maize. Intra-laboratory coefficients of variation (CV) (under repeatability conditions) were 9.16% for ZEA and 2.18% for α-ZOL. Recoveries for spiked ZEA and α-ZOL samples ranged from 89 to 110% with CVs between 5.2 and 11.2% (under within-laboratory reproducibility conditions). Using C18 and Florisil solid-phase clean-up, matrix interference was too high. Therefore, naturally contaminated animal feed samples were analysed using the developed HPLC method coupled to the immunoaffinity clean-up.  相似文献   

16.
Pinto PC  Saraiva ML  Santos JL  Lima JL 《Talanta》2006,68(3):857-862
A sequential injection analysis (SIA) methodology for the fluorimetric determination of aminocaproic acid in pharmaceutical formulations is proposed. The developed analytical procedure is based on the derivatisation reaction of the aminocaproic primary amine with o-phthalaldehyde (OPA) and N-acetylcysteine (NAC) and fluorimetric detection of the formed product (λex = 350 nm; λem = 450 nm). The implementation of a SIA flow system allowed for the development of a simple, fast and versatile automated methodology, which exhibits evident advantages regarding the US Pharmacopoeia 24 (USP 24) reference procedure. By combining the SIA time-based sample insertion with a subsequent zone sampling approach, which permitted to select for detection of a well-defined sample zone, it was possible to implement an on-line dilution strategy that enabled the expansion of the analytical working range of the methodology, and thus its application in dissolution studies, without manifold re-configuration.Linear calibration plots were obtained for aminocaproic acid concentrations up to 6 × 10−5 mol l−1. The developed methodology exhibit a good precision, with a R.S.D. < 2.0% (n = 15) and the detection limit was 2.5 × 10−7 mol l−1. The obtained results complied with those furnished by the reference procedure with a relative deviation lower than 1.2%. No interference was found.  相似文献   

17.
A highly sensitive catalytic quenching spectrofluorimetric method was described for the determination of V(V) based on its catalytic effect on the oxidation of 1,8-diaminonaphthalene by potassium bromate with Tiron as an activator in weakly acidic medium and the reaction mechanism was investigated. The reaction was followed spectrofluorimetrically by measuring the fluorescence intensity of 1,8-diaminonathphlene (DAN) (λex=356 nm, λem=439 nm) at a fixed time of 5 min from initiation of the reaction. Under the optimum conditions, vanadium(V) can be determined in the range 0.05-50.0 ng ml−1 with a S.D.=0.024 for 15 times measurements. The detection limit of the method was down to 0.0088 ng ml−1 and the catalytic reaction activation energy was found to be 43.92 kJ mol−1. The proposed method was tested for the determination of vanadium(V) in rice and natural water samples.  相似文献   

18.
Terbium sensitized fluorescence was used as a post-column detection system to develop a simple, sensitive and rapid high-performance liquid chromatographic method for the simultaneous determination of catecholamines norepinephrine (NE), epinephrine (E) and dopamine (DA).Catecholamines were separated by an ion-pair reversed-phase chromatography on a BDS-Hypersil analytical column with a mobile phase of methanol and 50 mmol l−1 acetate buffer (pH 4.7) containing 1.1 mmol l−1 SOS and 0.11 mmol l−1 EDTA (15+85 v/v).Catecholamines and the internal standard (3,4-dihydroxybenzylamine, DHBA) were post-column derivatized by the addition to the eluent of an alkaline solution containing a stoichiometric mixture of terbium(III) chloride and EDTA. Fluorescence detection (λex=300 nm, λem=545 nm) is based on the sensitization of terbium ion fluorescence after complexation with catecholamines.The chemical compatibility between the eluent and the post-column reagent was studied and the analytical characteristics of the method were established. Detection limits found were 1.0×10−8, 4.0×10−8 and 7.0×10−8 mol l−1 for NE, E and DA, respectively. The method has been successfully applied to the determination of catecholamines in urine samples after solid-phase extraction (SPE) pre-treatment. Recoveries from urine spiked with NE (4.0×10−7, 2.0×10−6 and 4.0×10−6 mol l−1), E (8.2×10−8, 4.1×10−7 and 8.2×10−7 mol l−1) and DA (1.0×10−6, 5.0×10−6 and 1.0×10−5 mol l−1) varied from 98 to 100% (mean=99.3%), from 106 to 107% (mean=106.3%) and from 98 to 101% (mean=99.3%), respectively. The between-run precision (relative standard deviation, R.S.D.) for the method for three urine samples at different concentration levels of each catecholamine varied from 3.6 to 7.0%.  相似文献   

19.
In this study the development, validation and application of a new chromatographic method for the determination of glutathione (GSH) in wine samples is presented. The separation of the GSH was carried out using a sulfobetaine-based hydrophilic interaction chromatography (HILIC) analytical column whereas its detection was carried out spectrofluorimetrically (λext/λem = 340/455 nm) after post-column derivatization with o-phthalaldehyde. GSH was separated efficiently from matrix endogenous compounds of wines by using a mobile phase of 15 mmol L−1 CH3COONH4 (pH = 2.5)/CH3CN, 35/65% (v/v). The parameters of the post-column reaction (pH, amount concentration of the reagent and buffer solution, flow rate, length of the reaction coil) were investigated. The linear determination range for GSH was 0.25–5.0 μmol L−1 and the LOD was 19 nmol L−1. No matrix effect was observed, while the accuracy was evaluated with recovery experiments and was ranged between 89% and 108%.  相似文献   

20.
A normal spectrophotometric and a stopped-flow (SF) spectrofluorimetric method have been developed and optimized for the determination of alendronic acid (ALD) in its pharmaceutical formulations. Both methods are automated using the sequential injection analysis (SIA) principle. The spectrophotometric assay is based on the reaction of the analyte with Cu(II) ions in acidic medium to form an UV-absorbing derivative (λmax = 240 nm). The SF spectrofluorimetric method is based on the reaction of ALD with o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol at basic medium (λex = 340 nm/λem = 455 nm). Linear calibration curves were obtained in the range 1.0-60.0 mg l−1 ALD for the UV method, and in the range 0.13-10.0 mg l−1 ALD for the SF spectrofluorimetric one. The sampling rates were 60 and 30 h−1, respectively. The developed assays are critically compared and their advantages are discussed. Both methods were applied to the analysis of an ALD containing pharmaceutical formulation with satisfactory accuracy and precision.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号