首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this paper, we synthesized flowerlike silver microspheres with nanostructures by simply reducing silver nitrate by ascorbic acid in the presence of PVP. The structure was investigated by SEM. The chemical composition was determined by EDX, XRD and XPS. Recent studies on hydrogen peroxide sensor based on silver nanoparticles inspired us to examine the electrocatalytic activity of prepared microspheres. This electrochemical sensor exhibited good electrocatalytic activity towards the reduction of H2O2 in 0.2 M phosphate buffer solution (pH 7.0), and the detection limit of H2O2 was found to be 1.2 μM, which was lower than certain enzyme-based biosensors.  相似文献   

2.
The development of an accurate and low-cost monitoring technique for hydrogen peroxide (H2O2) is a crucial demand in environment, food industry, medicine and biology. Herein, we report the design and synthesis of viologen terminated second (G2.0) and third generation (G3.0) poly(amidoamine) PAMAM dendrimers, followed by encapsulation with gold nanoparticles to form G2.0 and G3.0 Vio-PAMAM-AuNPs. The G2.0 and G3.0 Vio-PAMAM-AuNPs were deposited over glassy carbon electrode (GCE) to form G2.0 and G3.0 Vio-PAMAM-AuNPs/GCE modified electrodes, respectively. The electrochemical behavior of G2.0 and G3.0 Vio-PAMAM-AuNPs/GCEs were investigated using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Both the G2.0 and G3.0 Vio-PAMAM-AuNPs/GCEs showed a pair of well-defined redox peaks in 0.1 M phosphate buffer corresponding to the redox behavior of viologen V2+?V?+ radical. G3.0 Vio-PAMAM-AuNPs/GCE has shown a higher current response than that of the G2.0 Vio-PAMAM-AuNPs/GCE and further the G3.0 Vio-PAMAM-AuNPs/GCE demonstrated impressive electrocatalytic activity towards reduction of H2O2, based on which a nonenzymatic sensor for the detection of H2O2 has been developed. The developed nonenzymatic sensor has displayed excellent performance towards H2O2 detection in the broad linear range of 0.1 mM – 6.2 mM with a low detection limit of 27 μM and high sensitivity of 202.7 μA mM?1 cm?2. The G3.0 Vio-PAMAM-AuNPs/GCE modified electrode with its extensive dendritic structure creating tailored sanctuary to accommodate a large number of viologen mediator and AuNPs exhibited good operational and long term stability and further the quantification of H2O2 in real samples has been verified by standard addition method.  相似文献   

3.
《Comptes Rendus Chimie》2017,20(7):693-696
Silver nanorods (Ag NRs) with rough sidewalls were successfully obtained via extremely simple template-assisted electrochemical deposition followed by selective dealloying. Ag–Zn NRs with an average diameter of ∼250 nm and the atomic ratio of about 1:1 were synthesized inside the nanochannels of a polycarbonate membrane. A chemical etching of Zn in a sulfuric acid solution led to the formation of NRs with smaller diameters, rough sidewalls, and much lower Zn content. Such kind of a material exhibited quite promising electrocatalytic properties toward reduction of hydrogen peroxide and can be used as an amperometric sensor for the detection and determination of H2O2.  相似文献   

4.
Silver coated ZnO nanorods and nanoflakes with different crystallographic orientations were synthesized by a combination of sputter deposition and solution growth process. Catalytic properties of morphology‐dependent Ag/ZnO nanostructures were then investigated for urea sensors without enzyme. Ag/ZnO nanorods on carbon electrodes exhibit a higher catalytic activity and an improved efficiency than Ag/ZnO nanoflakes on carbon electrodes. Ag/ZnO nanorod catalysts with more electrochemically surface area (169 cm2 mg?1) on carbon electrode facilitate urea electrooxidation due to easier electron transfer, which further promotes the urea electrolysis. The Ag/ZnO nanorod catalysts also show a significant reduction in the onset voltage (0.410 V vs. Ag/AgCl) and an increase in the current density (12.0 mA cm?2 mg?1) at 0.55 V vs Ag/AgCl. The results on urea electrooxidation show that Ag/ZnO nanostructures can be a potential catalyst for non‐enzymatic biosensors and fuel cells.  相似文献   

5.
Wei Zhao  Xia Qin  Zixia Zhao  Lili Chen  Yuxin Fang 《Talanta》2009,80(2):1029-943
A novel strategy to fabricate hydrogen peroxide (H2O2) sensor was developed based on multi-wall carbon nanotube/silver nanoparticle nanohybrids (MWCNT/Ag nanohybrids) modified gold electrode. The process to synthesize MWCNT/Ag nanohybrids was facile and efficient. In the presence of carboxyl groups functionalized multi-wall carbon nanotubes (MWCNTs), silver nanoparticles (Ag NPs) were in situ generated from AgNO3 aqueous solution and readily attached to the MWCNTs convex surfaces at room temperature, without any additional reducing reagent or irradiation treatment. The formation of MWCNT/Ag nanohybrids product was observed by transmission electron microscope (TEM), and the electrochemical properties of MWCNT/Ag nanohybrids modified gold electrode were characterized by electrochemical measurements. The results showed that this sensor had a favorable catalytic ability for the reduction of H2O2. The resulted sensor could detect H2O2 in a linear range of 0.05-17 mM with a detection limit of 5 × 10−7 M at a signal-to-noise ratio of 3. The sensitivity was calculated as 1.42 μA/mM at a potential of −0.2 V. Additionally, it exhibited good reproducibility, long-term stability and negligible interference of ascorbic acid (AA), uric acid (UA), and acetaminophen (AP).  相似文献   

6.
Photocatalytic oxidation of glycerol at ambient conditions has been investigated with the use of Zinc oxide photocatalysts. Zinc oxide nanorods were prepared via a simple hydrothermal method using zinc nitrate and sodium hydroxide in the solution pH of 7, 8 and 9. The samples prepared in this way were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscope (TEM), Brunauer-Emmett-Teller (BET) and ultraviolet–visible spectroscopy (UV–vis). The pH of the solution is 7, the sample contains zinc hydroxide nitrate hydrated. When the pH of solution was adjusted to 8 and 9, the samples consisted of pure hexagonal wurtzite ZnO without impurity detection. The influence of solution pH on hydrogen formation was investigated. The wurtzite ZnO nanorods synthesized in a solution with pH 9 are considered promising photocatalysts for hydrogen production under xenon radiation.  相似文献   

7.
Ag nanoparticles were prepared by using the ion-exchange of Nafion combined with electrochemical reduction on the electrode. Ag nanoparticles are highly dispersed in Nafion film with an average size of 4.0±0.2 nm.The amount of Ag nanoparticles can be readily controlled by the amount of Nafion coated on the electrode.Thus obtained Ag nanoparticles exhibit good catalytic activity for the reduction of H2O2 with a linear response to H2O2 in the concentration range of 0.04-8.0 mmol/L with a sensitivity of 0.34μA/mmol/L and a detection limit of 1.0×10-8 mol/L.  相似文献   

8.
The electrocatalytic activity of a CuO flower-like nanostructured electrode was investigated in terms of its application to enzyme-less amperometric H2O2 sensors. The CuO nanoflowers film was directly formed by chemical oxidation of copper foil under hydrothermal condition and then used as active electrode material of non-enzymatic electrochemical sensors for H2O2 detection under alkaline conditions. The sensitivity of the sensor with CuO nanoflowers electrode was 88.4 μA/mM cm2 with a linear response in the range from 4.25 × 10−5 to 4 × 10−2 M and a detection limit of 0.167 μM (S/N = 3). Excellent electrocatalytic activity, large surface-to-volume ratio and efficient electron transport property of CuO nanoflowers electrode have enabled stable and highly sensitive performance for the non-enzymatic H2O2 sensor.  相似文献   

9.
Electrochemical detection of hydrogen peroxide using an edge-plane pyrolytic-graphite electrode (EPPG), a glassy carbon (GC) electrode, and a silver nanoparticle-modified GC electrode is reported. It is shown, in phosphate buffer (0.05 mol L–1, pH 7.4), that hydrogen peroxide cannot be detected directly on either the EPPG or GC electrodes. However, reduction can be facilitated by modification of the glassy-carbon surface with nanosized silver assemblies. The optimum conditions for modification of the GC electrode with silver nanoparticles were found to be deposition for 1 min at –0.5 V vs. Ag from 5 mmol L–1 AgNO3/0.1 mol L–1 TBAP/MeCN, followed by stripping for 2 min at +0.5 V vs. Ag in the same solution. A wave, due to the reduction of hydrogen peroxide on the silver nanoparticles is observed at –0.68 V vs. SCE. The limit of detection for this modified nanosilver electrode was 2.0×10–6 mol L–1 for hydrogen peroxide in phosphate buffer (0.05 mol L–1, pH 7.4) with a sensitivity which is five times higher than that observed at a silver macro-electrode. Also observed is a shoulder on the voltammetric wave corresponding to the reduction of oxygen, which is produced by silver-catalysed chemical decomposition of hydrogen peroxide to water and oxygen then oxygen reduction at the surface of the glassy-carbon electrode.  相似文献   

10.
A new electrochemical biosensor for determination of hydrogen peroxide (H2O2) has been developed by immobilizing horseradish peroxidase (HRP) on silver colloids (nanosilver) and use of a DNA-functionalized interface. In the presence of the DNA and the nanosilver the immobilized HRP gives a pair of well-defined redox peaks with an electron-transfer rate constant of 3.27 ± 0.91 s−1 in pH 7.0 PBS. The presence of DNA also provides a biocompatible microenvironment for enzyme molecules, greatly amplifies the amount of HRP molecules immobilized on the electrode surface, and improves the sensitivity of the biosensor. Under optimum conditions the biosensor has electrocatalytic activity in the reduction of hydrogen peroxide with linear dependence on H2O2 concentration in the range 1.5 × 10−6 to 2.0 × 10−3 mol L−1; the detection limit is 5.0 × 10−7 mol L−1 at a signal-to-noise ratio of 3. The value of HRP in the composite membrane was found to be 1.62 mmol L−1. These results suggest that the properties of the complex film, with its bioelectrochemical catalytic activity, could make it useful for development of bioelectronic devices and for investigation of protein electrochemistry at functional interfaces.  相似文献   

11.
《中国化学会会志》2018,65(9):1082-1089
In this work, a screen‐printed carbon electrode (SPCE) was modified with a cobalt/porous silicon (Co@PSi) nanocomposite powder to develop a nonenzymatic sensor for the detection of hydrogen peroxide. The Co@PSi nanocomposite was synthesized through the chemical reaction between silicon powder in a HF/HNO3 solution and cobalt cations. In this process, cobalt nanoparticles were anchored on the porous silicon. The structure and morphology of the synthesized nanocomposite were investigated by X‐ray diffraction, Fourier transform infrared spectroscopy, X‐ray photoemission spectroscopy, energy dispersive X‐ray spectroscopy, and field‐emission scanning electron microscopy. The constructed nonenzymatic, screen‐printed sensors based on the Co@PSi nanocomposite showed perfect electrocatalytic oxidation response to hydrogen peroxide over the range 1–170 and 170–3,770 μmol/L with the limit of detection of 0.8 μmol/L. In addition, the Co@PSi‐SPCE sensor exhibited good selectivity for the determination of H2O2 in the presence of common interfering species including glucose, ascorbic acid, uric acid, dopamine, nitrate, and nitrite ions. The constructed electrochemical sensor was successfully used for the determination of H2O2 in real samples.  相似文献   

12.
Zheng X  Guo Z 《Talanta》2000,50(6):196-1162
A novel hydrogen peroxide (H2O2) potentiometric sensor, made with a MnO2-doped carbon paste electrode (CPE), is reported. Under optimum conditions, the electrode gives a Nernstian response for H2O2 in the concentration range 3.00×10−7–3.63×10−4 mol/l, with a slope of 21–19.4 mV/pH2O2 and a detection limit of 1.2×10−7mol/l H2O2. In addition, this sensor offers some analytical characteristics such as sensitivity, good reproducibility and a simple preparation procedure. The effects of both the components of the electrode and other conditions on the potential response of the sensor, as well as the possible response mechanism, are discussed.  相似文献   

13.
Li S  Zheng Y  Qin GW  Ren Y  Pei W  Zuo L 《Talanta》2011,85(3):1260-1264
In this paper, an enzyme-free amperometric electrochemical sensor was fabricated by casting Nafion-impregnated Cu2O particles onto a glassy carbon electrode. A dual dependence of peak current on sweeping rate, which can be attributed for the accumulation of reaction products, was observed on the sensor. Electrochemical analysis of the particulate Cu2O for detecting H2O2 and glucose is described, showing remarkable sensitivity in both cases. The estimated detection limits and sensitivities for H2O2 (0.0039 μM, 52.3 mA mM−1 cm−2) and glucose (47.2 μM, 0.19 mA mM−1 cm−2) suggest that the response for H2O2 detection was much higher than for glucose detection. Electron microscopy observation suggested that the hierarchical structures of Cu2O resulting from self-assembly of nanocrystals are responsible for the specific electrochemical properties.  相似文献   

14.
A hierarchical nanostructure consisting of uniform copper oxide nanowires vertically grown on three-dimensional copper framework (CuO NWs/3D-Cu foam) was prepared by a two-step synthetic process. The uniform CuO NWs anchored onto the 3D foam exhibited outstanding electrocatalytic activity towards hydrogen peroxide reduction due to the unique one‐dimensional direction with its excellent catalytic activity and large surface area of 3D substrate, which enhanced electroactive sites and charge conductivity. As a result, a wide linear detection range of 1 µM–1 mM, good sensitivity of 8.87 µA/(mM ⋅ cm2), low detection limit of 0.98 µM, and rapid response time of 5 s to hydrogen peroxide were achieved under a working potential of −0.4 V in phosphate buffer solution (pH of 7.4). In addition, the CuO NWs/3D-Cu foam material showed excellent selectivity to hydrogen peroxide and good resistance against poisonous interferents, including ascorbic acid, dopamine, urea, uric acid, and potassium chloride. Furthermore, the CuO NWs/3D-Cu foam presented good reproducibility, stability, and accurate detection for hydrogen peroxide in real sample; therefore, it may be considered to be a potential free-standing hydrogen peroxide sensor in practical analysis applications.  相似文献   

15.
采用嵌入修饰法制得了碳纳米管负载铂修饰的浸蜡石墨电极,结果发现该修饰电极对H2O2的氧化还原都有良好的电催化性能。但对H2O2的还原有更好的催化性能。H2O2的浓度在2.5×10-6~1×10-4mol/L范围内呈现良好的线性关系;检出限为1.26×10-6mol/L。  相似文献   

16.
Onion-like mesoporous carbon vesicle (MCV) with multilayer lamellar structure was synthesized by a simply aqueous emulsion co-assembly approach. Palladium (Pd) nanoparticles were deposited on the MCV matrix (Pd/MCV) by chemical reduction of H2PdCl4 with NaBH4 in aqueous media. Pd(X)/MCV (X wt.% indicates the Pd loading amount) nanocomposites with different Pd loading amount were obtained by adjusting the ratio of precursors. The particular structure of the MCV results in efficient mass transport and the onion-like layers of MCV allows for the obtainment of highly dispersed Pd nanoparticles. The introduction of Pd nanoparticles on the MCV matrix facilitates hydrazine oxidation at more negative potential and delivers higher oxidation current in comparison with MCV. A linear range from 2.0 × 10−8 to 7.1 × 10−5 M and a low detection limit of 14.9 nM for hydrazine are obtained at Pd(25)/MCV nanocomposite modified glassy carbon (GC) electrode. A nonenzymatic amperometric sensor for hydrogen peroxide based on the Pd(25)/MCV nanocomposite modified GC electrode is also developed. Compared with MCV modified GC electrode, the Pd(25)/MCV nanocomposite modified GC electrode displays enhanced amperometric responses towards hydrogen peroxide and gives a linear range from 1.0 × 10−7 to 6.1 × 10−3 M. The Pd(25)/MCV nanocomposite modified GC electrode achieves 95% of the steady-current for hydrogen peroxide within 1 s. The combination of the unique properties of Pd nanoparticles and the porous mesostructure of MCV matrix guarantees the improved analytical performance for hydrazine and hydrogen peroxide.  相似文献   

17.
Lei CX  Hu SQ  Shen GL  Yu RQ 《Talanta》2003,59(5):981-988
A procedure for fabricating an enzyme electrode has been described based on the effective immobilization of horseradish peroxidase (HRP) to a nano-scaled particulate gold (nano-Au) monolayer modified chitosan-entrapped carbon paste electrode (CCPE). The high affinity of chitosan entrapped in CCPE for nano-Au associated with its amino groups has been utilized to realize the use of nano-Au as an intermediator to retain high bioactivity of the enzyme. Hydrogen peroxide (H2O2) was determined in the presence of hydroquinone as a mediator to transfer electrons between the electrode and HRP. The HRP immobilized on nano-Au displayed excellent electrocatalytical activity to the reduction of H2O2. The effects of experimental variables such as the operating potential of the working electrode, mediator concentration and pH of measuring solution were investigated for optimum analytical performance by using an amperometric method. The enzyme electrode provided a linear response to hydrogen peroxide over a concentration range of 1.22×10−5-2.43×10−3 mol l−1 with a sensitivity of 0.013 A l mol−1 cm−2 and a detection limit of 6.3 μmol l−1 based on signal per noise =3. The apparent Michaelis-Menten constant (Kmapp) for the sensor was found to be 0.36 mmol l−1. The lifetime, fabrication reproducibility and measurement repeatability were evaluated with satisfactory results. The analysis results of real sample by this sensor were in satisfactory agreement with those of the potassium permanganate titration method.  相似文献   

18.
A mixed-valence cluster of cobalt(II)hexacyanoferrate possesses an electron transfer property and is suitable for the development of an effective hydrogen peroxide detection scheme. The characteristics of cobalt(II)hexacyanoferrate have been studied using both elemental analysis and infrared spectra, confirming the structure is Co[FeII(CN)6]. The cobalt(II)hexacyanoferrate-modified electrode exhibits a rapid response (t95% - 6.5 s) to the injection of 5.0 × 10−5 M hydrogen peroxide. The linearity of the response is up to 1.1 × 10−3 M (correlation coefficients is 0.999). The sensitivity of this modified electrode is 11.8 μA/mM-mm2. The detection limit of cobalt(II)hexacyanoferrate-modified electrode to hydrogen peroxide is 6.25 × 10−8 M. The current chemical sensor modified with Co[FeII(CN)6] has better sensitivity than previous ones. The modified glassy carbon electrode shows no interference from ascorbic acid, uric acid, acetaminophen, 1,4-dihydroxyquinone, dopamine at the 2.0 × 10−4 M level and polyamines at 5.0 × 10−5 M level.  相似文献   

19.
Campuzano S  Pedrero M  Pingarrón JM 《Talanta》2005,66(5):1310-1319
The construction and performance under flow-injection conditions of an integrated amperometric biosensor for hydrogen peroxide is reported. The design of the bioelectrode is based on a mercaptopropionic acid (MPA) self-assembled monolayer (SAM) modified gold disk electrode on which horseradish peroxidase (HRP, 24.3 U) was immobilized by cross-linking with glutaraldehyde together with the mediator tetrathiafulvalene (TTF, 1 μmol), which was entrapped in the three-dimensional aggregate formed.

The amperometric biosensor allows the obtention of reproducible flow injection amperometric responses at an applied potential of 0.00 V in 0.05 mol L−1 phosphate buffer, pH 7.0 (flow rate: 1.40 mL min−1, injection volume: 150 μL), with a range of linearity for hydrogen peroxide within the 2.0 × 10−7–1.0 × 10−4 mol L−1 concentration range (slope: (2.33 ± 0.02) × 10−2 A mol−1 L, r = 0.999). A detection limit of 6.9 × 10−8 mol L−1 was obtained together with a R.S.D. (n = 50) of 2.7% for a hydrogen peroxide concentration level of 5.0 × 10−5 mol L−1. The immobilization method showed a good reproducibility with a R.S.D. of 5.3% for five different electrodes. Moreover, the useful lifetime of one single biosensor was estimated in 13 days.

The SAM-based biosensor was applied for the determination of hydrogen peroxide in rainwater and in a hair dye. The results obtained were validated by comparison with those obtained with a spectrophotometric reference method. In addition, the recovery of hydrogen peroxide in sterilised milk was tested.  相似文献   


20.
A new sensor for simultaneous determination of peroxyacetic acid and hydrogen peroxide using silver nanoparticles (Ag-NPs) as a chromogenic reagent is introduced. The silver nanoparticles have the catalytic ability for the decomposition of peroxyacetic acid and hydrogen peroxide; then the decomposition of them induces the degradation of silver nanoparticles. Hence, a remarkable change in the localized surface plasmon resonance absorbance strength could be observed. Spectra-kinetic approach and artificial neural network was applied for the simultaneous determination of peroxyacetic acid and hydrogen peroxide. Linear calibration graphs were obtained in the concentration range of (8.20 × 10−5 to 2.00 × 10−3 mol L−1) for peroxyacetic acid and (2.00 × 10−5 to 4.80 × 10−3 mol L−1) for hydrogen peroxide. The analytical performance of this sensor has been evaluated for the detection of simultaneous determination of peroxyacetic acid and hydrogen peroxide in real samples.  相似文献   