首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The relative quantification and identification of proteins by matrix‐assisted laser desorption ionization time‐of‐flight MS is very important in /MS is very important in protein research and is usually conducted separately. Chemical N‐terminal derivatization with 4‐sulphophenyl isothiocyanate facilitates de novo sequencing analysis and accurate protein identification, while 18O labeling is simple, specific and widely applicable among the isotopic labeling methods used for relative quantification. In the present study, a method combining 4‐sulphophenyl isothiocyanate derivatization with 18O isotopic labeling was established to identify and quantify proteins simultaneously in one experiment. Reaction conditions were first optimized using a standard peptide (fibrin peptide) and tryptic peptides from the model protein (bovine serum albumin). Under the optimized conditions, these two independent labeling steps show good compatibility, and the linear relativity of quantification within the ten times dynamic range was stable as revealed by correlation coefficient analysis (R2 value = 0.998); moreover, precursor peaks in MS/MS spectrum could provide accurate quantitative information, which is usually acquired from MS spectrum, enabling protein identification and quantification in a single MS/MS spectrum. Next, this method was applied to native peptides isolated from spider venoms. As expected, the de novo sequencing results of each peptide matched with the known sequence precisely, and the measured quantitative ratio of each peptide corresponded well with the theoretical ratio. Finally, complex protein mixtures of spider venoms from male and female species with unknown genome information were analyzed. Differentially expressed proteins were successfully identified, and their quantitative information was also accessed. Taken together, this protein identification and quantification method is simple, reliable and efficient, which has a good potential in the exploration of peptides/proteins from species with unknown genome. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
Nowadays isotopic 18O-labeling of peptides has recalled the attention of researchers due to its simplicity of application and high versatility for proteomics studies. Protein quantification, differential peptide mass mapping, studies regarding proteins overexpressed or underexpressed, or the searching of biomarkers can be accomplished by using 18O-labeling. In this critical review we comment on the different ways in which 18O-labeling can be done, highlighting the key parameters of the different sample treatments to obtain a reliable and reproducible labeling. In addition we describe and compare the latest improvement in terms of sample treatment that allows to reduce the handling and to increase the throughput for this sample treatment. Finally, we hypothesize on the future trends of these methods under the light of the new technological advances to speed protein cleavage.  相似文献   

3.
To reduce the influence of the between-spectra variability on the results of peptide quantification, one can consider the 18O-labeling approach. Ideally, with such labeling technique, a mass shift of 4 Da of the isotopic distributions of peptides from the labeled sample is induced, which allows one to distinguish the two samples and to quantify the relative abundance of the peptides. It is worth noting, however, that the presence of small quantities of 16O and 17O atoms during the labeling step can cause incomplete labeling. In practice, ignoring incomplete labeling may result in the biased estimation of the relative abundance of the peptide in the compared samples. A Markov model was developed to address this issue (Zhu, Valkenborg, Burzykowski. J. Proteome Res. 9, 2669–2677, 2010). The model assumed that the peak intensities were normally distributed with heteroscedasticity using a power-of-the-mean variance funtion. Such a dependence has been observed in practice. Alternatively, we formulate the model within the Bayesian framework. This opens the possibility to further extend the model by the inclusion of random effects that can be used to capture the biological/technical variability of the peptide abundance. The operational characteristics of the model were investigated by applications to real-life mass-spectrometry data sets and a simulation study.  相似文献   

4.
A comparison is made between plasma profiling time‐of‐flight mass spectrometry (PP‐TOFMS) and nuclear reaction analysis (NRA) for depth profiling of 18O tracer in porous anodic oxide films on aluminum. The films were formed galvanostatically, for a range of times, using phosphoric acid electrolytes that were either enriched in 18O or of the natural isotopic concentration. The morphologies of the films were determined by electron microscopy. The findings from PP‐TOFMS and NRA reveal a partitioning of the tracer between the surface regions and buried layers of the films. However, a relatively high background of 16O in PP‐TOFMS prevents a reliable quantification of the concentration of 18O. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
Preliminary results regarding fast isotopic labeling of proteins with (18)O in conjunction with matrix assisted laser desorption ionization time of flight mass spectrometry technique are presented. Similar (16)O/(18)O isotopic labeling ratios were found for the overnight procedure (12h) and the new fast ultrasonic one (30 min) for the BSA, ovalbumin and alpha-lactalbumin proteins. The procedure, however, failed to promote double (18)O isotopic labeling for the proteins, ovalbumin and alpha-lactalbumin. Two different sonication frequencies, 35 and 130 kHz, were studied at two different sonication times of 15 and 30 min, being best results obtained with the procedure at 130 kHz of sonication frequency and 30 min of sonication time. For comparative purposes the overnight isotopic (18)O labeling procedure was done. In addition, the new fast isotopic labeling procedure was also studied without ultrasonication, in a water bath at 60 degrees C.  相似文献   

6.
建立了定量肽段串联体蛋白质(concatamers of Q peptides, QconCATs)结合18O同位素标记-多反应监测质谱的蛋白质绝对定量新方法。首先对QconCAT重组蛋白质进行了纯度表征,十二烷基硫酸钠-聚丙烯酰胺凝胶电泳(SDS-PAGE)表征结果表明重组蛋白质的纯度在99%以上,相对分子质量约为63.4 kDa。对QconCAT重组蛋白质酶切后的肽段混合物进行质谱分析,并经pFind和pLabel软件处理,验证了目标肽段。还考察了QconCAT重组蛋白质的酶切效率和18O标记效率,并对QconCAT蛋白质结合18O标记-同位素稀释-多反应监测质谱方法进行了评价。实验结果表明,采用该方法对腾冲嗜热厌氧菌(Thermoanaerobacter tengcongensis, TTE)中选定蛋白质的肽段进行绝对含量测定时,相对标准偏差小于20%,准确度较高,说明该方法可用于复杂生物样本中蛋白质的绝对定量。更重要的是所建方法不仅解决了细胞培养氨基酸稳定同位素标记(SILAC)技术的重标试剂价格昂贵的问题,也为定量蛋白质组学提供了一种新的方法。  相似文献   

7.
We have used a high‐precision, easy, low‐cost and rapid method of oxygen isotope analysis applied to various O‐bearing matrices, organic and inorganic (sulfates, nitrates and phosphates), whose 18O/16O ratios had already been measured. It was first successfully applied to 18O analyses of natural and synthetic phosphate samples. The technique uses high‐temperature elemental analysis–pyrolysis (EA‐pyrolysis) interfaced in continuous‐flow mode to an isotope ratio mass spectrometry (IRMS) system. Using the same pyrolysis method we have been able to generate a single calibration curve for all those samples showing pyrolysis efficiencies independent of the type of matrix pyrolysed. We have also investigated this matrix‐dependent pyrolysis issue using a newly developed pyrolysis technique involving 'purge‐and‐trap' chromatography. As previously stated, silver phosphate being a very stable material, weakly hygroscopic and easily synthesized with predictable 18O/16O values, could be considered as a good candidate to become a reference material for the determination of 18O/16O ratios by EA‐pyrolysis‐IRMS. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
A sensitive and reliable liquid chromatography tandem mass spectrometry (LC–MS/MS) method was developed to determine cyanidin‐3‐O‐glucoside (Cy‐3G) in normal and streptozotocin‐induced diabetic rat plasma. Chromatographic separation was carried out on a Zorbax SB‐C18 (50 × 4.6 mm, 5 μm) column and mass spectrometric analysis was performed using a Thermo Finnigan TSQ Quantum Ultra triple‐quadrupole mass spectrometer coupled with an ESI source in the negative ion mode. Selected reaction monitoring mode was applied for quantification using target fragment ions m/z 447.3 → 285.2 for Cy‐3G and m/z 463.0 → 300.1 for quercetin‐3‐O‐glucoside (internal standard). The calibration curve was linear over the range 3.00–2700 ng/mL (r2 ≥ 0.99) with the lower limit of quantitation at 3.00 ng/mL. Intra‐ and inter‐day precision was <14.5% and mean accuracy was from −11.5 to 13.6%. Stability testing showed that Cy‐3G remained stable during the whole analytical procedure. After validation, the assay was successfully used to support a preclinical pharmacokinetic comparison of Cy‐3G between normal and diabetic rats. Results indicated that diabetes mellitus significantly altered the in vivo pharmacokinetic characteristics of Cy‐3G after oral administration in rats.  相似文献   

9.
The natural variation of the oxygen isotopic composition is used among geologists to determine paleotemperatures and the origin of minerals. In recent studies, oxygen isotopic composition has been recognized as a possible tool for identification of the origin of seized uranium oxides in nuclear forensic science. In the last 10 years, great effort has been made to develop new direct and accurate n(18O)/n(16O) measurements methods. Traditionally, n(18O)/n(16O) analyses are performed by gas mass spectrometry. In this work, a novel oxygen isotope analysis by thermal ionization mass spectrometry (TIMS), using metal oxide ion species (UO+), is compared to the direct methods: glow discharge mass spectrometry (GDMS) and secondary ion mass spectrometry (SIMS). Because of the possible application of the n(18O)/n(16O) ratio in nuclear forensics science, the samples were solid, pure UO2 or U3O8 particles. The precision achieved using TIMS analysis was 0.04%, which is similar or even better than the one obtained using the SIMS technique (0.05%), and clearly better if compared to that of GDMS (0.5%). The samples used by TIMS are micrograms in size. The suitability of TIMS as a n(18O)/n(16O) measurement method is verified by SIMS measurements. In addition, TIMS results have been confirmed by characterizing the n(18O)/n(16O) ratio of UO2 sample also by the traditional method of static vacuum mass spectrometry at the University of Chicago.  相似文献   

10.
Quantitative or comparative proteome analysis was initially performed with 2-dimensional gel electrophoresis with the inherent disadvantages of being biased towards certain proteins and being labor intensive. Alternative mass spectrometry-based approaches in conjunction with gel-free protein/peptide separation have been developed in recent years using various stable isotope labeling techniques. Common to all these techniques is the incorporation, biosynthetically or chemically, of a labeling moiety having either a natural isotope distribution of hydrogen, carbon, oxygen, or nitrogen (light form) or being enriched with heavy isotopes like deuterium, (13)C, (18)O, or (15)N, respectively. By mixing equal amounts of a control sample possessing for instance the light form of the label with a heavy-labeled case sample, differentially labeled peptides are detected by mass spectrometric methods and their intensities serve as a means for direct relative protein quantification. While each of the different labeling methods has its advantages and disadvantages, the endoprotease (16)O-to-(18)O catalyzed oxygen exchange at the C-terminal carboxylic acid is extremely promising because of the specificity assured by the enzymatic reaction and the labeling of essentially every protease-derived peptide. We show here that this methodology is applicable to complex biological samples such as a subfraction of human plasma. Furthermore, despite the relatively small mass difference of 4 Da between the two labeled forms, corresponding to the exchange of two oxygen atoms by two (18)O isotopes, it is possible to quantify differentially labeled proteins on an ion trap mass spectrometer with a mass resolution of about 2000 in automated data dependent LC-MS/MS acquisition mode. Post column sample deposition on a MALDI target parallel to on-line ESI-MS/MS enables the analysis of the same compounds by means of ESI- and MALDI-MS/MS. This has the potential to increase the confidence in the quantification results as well as to increase the sequence coverage of potentially interesting proteins by complementary peptide ionization techniques. Additionally the paired y-ion signals in tandem mass spectra of (16)O/(18)O-labeled peptide pairs provide a means to confirm automatic protein identification results or even to assist de novo sequencing of yet unknown proteins.  相似文献   

11.
Metabolomic profiling involves relative quantification of metabolites in comparative samples and identification of the significant metabolites that differentiate different groups (e.g., diseased vs. controls). Chemical isotope labeling (CIL) liquid chromatography–mass spectrometry (LC–MS) is an enabling technique that can provide improved metabolome coverage and metabolite quantification. However, chemical identification of labeled metabolites can still be a challenge. In this work, a new set of isotopic labeling reagents offering versatile properties to enhance both detection and identification are described. They were prepared by a glycine molecule (or its isotopic counterpart) and an aromatic acid with varying structures through a simple three-step synthesis route. In addition to relatively low costs of synthesizing the reagents, this reaction route allows adjusting reagent property in accordance with the desired application objective. To date, two isotopic reagents, 4-dimethylaminobenzoylamido acetic acid N-hydroxylsuccinimide ester (DBAA-NHS) and 4-methoxybenzoylamido acetic acid N-hydroxylsuccinimide ester (MBAA-NHS), for labeling the amine-containing metabolites (i.e., amine submetabolome) have been synthesized. The labeling conditions and the related LC–MS method have been optimized. We demonstrate that DBAA labeling can increase the metabolite detectability because of the presence of an electrospray ionization (ESI)-active dimethylaminobenzoyl group. On the other hand, MBAA labeled metabolites can be fragmented in MS/MS and pseudo MS3 experiments to provide structural information on metabolites of interest. Thus, these reagents can be tailored to quantitative profiling of the amine submetabolome as well as metabolite identification in metabolomics applications.  相似文献   

12.
The 18O and 2H of water vapor serve as powerful tracers of hydrological processes. The typical method for determining water vapor δ18O and δ2H involves cryogenic trapping and isotope ratio mass spectrometry. Even with recent technical advances, these methods cannot resolve vapor composition at high temporal resolutions. In recent years, a few groups have developed continuous laser absorption spectroscopy (LAS) approaches for measuring δ18O and δ2H which achieve accuracy levels similar to those of lab‐based mass spectrometry methods. Unfortunately, most LAS systems need cryogenic cooling and constant calibration to a reference gas, and have substantial power requirements, making them unsuitable for long‐term field deployment at remote field sites. A new method called Off‐Axis Integrated Cavity Output Spectroscopy (OA‐ICOS) has been developed which requires extremely low‐energy consumption and neither reference gas nor cryogenic cooling. In this report, we develop a relatively simple pumping system coupled to a dew point generator to calibrate an ICOS‐based instrument (Los Gatos Research Water Vapor Isotope Analyzer (WVIA) DLT‐100) under various pressures using liquid water with known isotopic signatures. Results show that the WVIA can be successfully calibrated using this customized system for different pressure settings, which ensure that this instrument can be combined with other gas‐sampling systems. The precisions of this instrument and the associated calibration method can reach ~0.08‰ for δ18O and ~0.4‰ for δ2H. Compared with conventional mass spectrometry and other LAS‐based methods, the OA‐ICOS technique provides a promising alternative tool for continuous water vapor isotopic measurements in field deployments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
建立了分析测定水环境中十氯酮的液相色谱-串联质谱法。水样经液液萃取、净化后,采用Eclipse plus C18柱(100 mm×2.1 mm,3.5 μm)分离,乙腈和水为流动相进行梯度洗脱,在电喷雾负离子多反应监测模式下进行检测,同位素内标法定量。结果表明:采用液相色谱-质谱联用技术,证实了十氯酮在甲醇中以半缩醛的形式存在,而在丙酮/乙腈中以偕二醇的形式存在。由于十氯酮极性较强,在净化时难以洗脱,并且不耐酸,所以不能与其他有机氯农药一起分析。十氯酮在5~100 μg/L范围有良好的线性关系,相关系数r2=0.999,检出限及定量限分别为0.70 ng/L和2.8 ng/L;在5、40和100 ng/L 3个浓度添加水平的平均回收率为95.1%~98.9%,相对标准偏差为3.85%~4.72%。本方法具有良好的灵敏度、回收率和重现性,适用于水环境中十氯酮的测定。  相似文献   

14.
15.
A mass spectrometer for isotopic analysis of solid uranium samples has been constructed and evaluated. This system employs the fluorinating agent chlorine trifluoride (ClF3) to convert solid uranium samples into their volatile uranium hexafluorides (UF6). The majority of unwanted gaseous byproducts and remaining ClF3 are removed from the sample vessel by condensing the UF6 and then pumping away the unwanted gases. The UF6 gas is then introduced into a quadrupole mass spectrometer and ionized by electron impact ionization. The doubly charged bare metal uranium ion (U2+) is used to determine the U235/U238 isotopic ratio. Precision and accuracy for several isotopic standards were found to be better than 12%, without further calibration of the system. The analysis can be completed in 25 min from sample loading, to UF6 reaction, to mass spectral analysis. The method is amenable to uranium solid matrices, and other actinides.  相似文献   

16.
N-Linked glycosylation is a major protein modification involved in many essential cellular functions. Methods capable of quantitative glycan analysis are highly valuable and have been actively pursued. Here we describe a novel N-glycosylamine-based strategy for isotopic labeling of N-linked glycans for quantitative analysis by use of mass spectrometry (MS). This strategy relies on the primary amine group on the reducing end of freshly released N-linked glycans for labeling, and eliminates the need for the harsh labeling reaction conditions and/or tedious cleanup procedures required by existing methods. By using NHS-ester amine chemistry we used this strategy to label N-linked glycans from a monoclonal antibody with commercially available tandem mass tags (TMT). Only duplex experiments can be performed with currently available TMT reagents, because quantification is based on the intensity of intact labeled glycans. Under mild reaction conditions, greater than 95 % derivatization was achieved in 30 min and the labeled glycans, when kept at ?20 °C, were stable for more than 10 days. By performing glycan release, TMT labeling, and LC–MS analysis continuously in a single volatile aqueous buffer without cleanup steps, we were able to complete the entire analysis in less than 2 h. Quantification was highly accurate and the dynamic range was large. Compared with previously established methods, N-glycosylamine-mediated labeling has the advantages of experimental simplicity, efficient labeling, and preserving glycan integrity.
Principle of N-Glycosylamine-mediated isotope labeling for mass spectrometry-based quantitative analysis of N-linked glycans  相似文献   

17.
Nylon 6.6 containing 13C isotopic labels at specific positions along the macromolecular backbone has been subjected to extensive thermal-oxidative aging at 138 °C for time periods up to 243 days. In complementary experiments, unlabeled Nylon 6.6 was subjected to the same aging conditions under an atmosphere of 18O2. Volatile organic degradation products were analyzed by cryofocusing gas chromatography mass spectrometry (cryo-GC/MS) to identify the isotopic labeling. The labeling results, combined with basic considerations of free radical reaction chemistry, provided insights to the origin of degradation species, with respect to the macromolecular structure. A number of inferences on chemical mechanisms were drawn, based on 1) the presence (or absence) of the isotopic labels in the various products, 2) the location of the isotope within the product molecule, and 3) the relative abundance of products as indicated by large differences in peak intensities in the gas chromatogram. The overall degradation results can be understood in terms of free radical pathways originating from initial attacks on three different positions along the nylon chain which include hydrogen abstraction from: the (CH2) group adjacent to the nitrogen atom, at the (CH2) adjacent the carbonyl group, and direct radical attack on the carbonyl. Understanding the pathways which lead to Nylon 6.6 degradation ultimately provides new insight into changes that can be leveraged to detect and reduce early aging and minimize problems associated with material degradation.  相似文献   

18.
A method is described for the identification and relative quantification of proteomes using accurate mass tags (AMT) generated by nLC-dual ESI-FT-ICR-MS on a 7T instrument in conjunction with stable isotope labeling using 16O/18O ratios. AMTs were used for putative peptide identification, followed by confirmation of peptide identity by tandem mass spectrometry. For a combined set of 58 tryptic peptides from bovine serum albumin (BSA) and human transferrin, a mean mass measurement accuracy of 1.9 ppm +/-0.94 ppm (CIM99%) was obtained. This subset of tryptic peptides was used to measure 16O/18O ratios of 0.36 +/- 0.09 (CIM99%) for BSA (micro = 0.33) and 1.48 +/- 0.47 (CIM99%) for transferrin (micro = 1.0) using a method for calculating 16O/18O ratios from overlapping isotopic multiplets arising from mixtures of 16O, 18O1, and 18O2 labeled C-termini. The model amino acid averagine was used to calculate a representative molecular formula for estimating and subtracting the contributions of naturally occurring isotopes solely as a function of peptide molecular weight. The method was tested against simulated composite 16O/18O spectra where peptide molecular weight, 16O/18O ratio, 18O1/18O2 ratios, and number of sulfur atoms were varied. Relative errors of 20% or less were incurred when the 16O/18O ratios were less than three, even for peptides where the number of sulfur atoms was over- or under-estimated. These data demonstrate that for biomarker discovery, it is advantageous to label the proteome representing the disease state with 18O; and the method is not sensitive to variations in 18O1/18O2 ratio. This approach allows a comprehensive differentiation of expression levels and tentative identification via AMTs, followed by targeted analysis of over- and under-expressed peptides using tandem mass spectrometry, for applications such as the discovery of disease biomarkers.  相似文献   

19.
Mass isotopomer analysis is an important technique to measure the production and flow of metabolites in living cells, tissues, and organisms. This technique depends on accurate quantifications of different mass isotopomers using mass spectrometry. Constructing calibration curves using standard samples is the most universal approach to convert raw mass spectrometry measurements into quantitative distributions of mass isotopomers. Calibration curve approach has been, however, of very limited use in comprehensive analyses of biological systems, mainly suffering from the lack of extensive range of standard samples with accurately known isotopic enrichment. Here, we present a biological method capable of synthesizing specifically labeled amino acids. These amino acids have well‐determined and estimable mass isotopomer distributions and thus can serve as standard samples. In this method, the bacterium strain Methylobacterium salsuginis sp. nov. was cultivated with partially 13C‐labeled methanol as the only carbon source to produce 13C‐enriched compounds. We show that the mass isotopomer distributions of the various biosynthesized amino acids are well determined and can be reasonably estimated based on proposed binomial approximation if the labeling state of the biomass reached an isotopic steady state. The interference of intramolecular inhomogeneity of 13C isotope abundances caused by biological isotope fractionation was eliminated by estimating average 13C isotope abundance. Further, the predictions are tested experimentally by mass spectrometry (MS) spectra of the labeled glycine, alanine, and aspartic acid. Most of the error in mass spectrometry measurements was less than 0.74 mol% in the test case, significantly reduced as compared with uncalibrated results, and this error is expected to be less than 0.4 mol% in real experiment as revealed by theoretical analysis. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
We present a new isotopic labeling strategy to modify the N-terminal amino group of peptides in a quantifiable reaction without the use of expensive reagents or solvents. The In Vacuo Isotope Coded Alkylation Technique (IVICAT) is a methylation reaction, carried out at low pressure (<100 mTorr), that results in a stable quaternary trimethylammonium group, thus adding a permanent positive charge at the N-terminus of peptides without modifying the epsilon-amino groups of lysine. The methylation reaction increases the signal intensity of modified peptides in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and liquid chromatography (LC)/MS and the isotopic peak pair differs by 9 mass units which can be easily resolved by either instrument. N-terminally trimethylated peptides exhibit collision-induced dissociation (CID) mass spectra that differ from their unmodified analogues by an enhanced b-ion series in MS2 spectra due to the fixed positive charge. Using LC/MS/MS with an LTQ mass analyzer for quantification, the experimentally determined ratios of H9- to D9-trimethyl-labeled peptides of beta-casein provided accurate estimates of the actual ratios with low % error. IVICAT labeling also accurately quantified proteins in rat kidney inner medullary collecting duct cell types, as judged by comparison with relative quantification by subsequent immunoblotting experiments. IVICAT labeling, when used in conjunction with the new proteomics software QUIL, can accurately report relative protein abundances and increase the sequence coverage of proteins of tissue proteomes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏