首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A robust optical composite thin film dissolved oxygen sensor was fabricated by ionically trapping the dye ruthenium(II) tris(4,7-diphenyl-1,10-phenanthroline) dichloride in a blended fluoropolymer matrix consisting of Nafion® and Aflas®. Strong phosphorescence, which was strongly quenched by dissolved oxygen (DO), was observed when the sensor was immersed in water. The sensor was robust, optically transparent, with good mechanical properties. Fast response, of a few seconds, coupled with sensitivity of about 0.1 mg L−1 (DO) over the range 0-30 mg L−1 and resistance to leaching, were also exhibited by this system. The Stern-Volmer (SV) plot exhibited slight downward turning at all oxygen concentrations. A linear plot was obtained when the SV equation was modified to account for the varying sensitivity of dye molecules in the matrix to the quencher. Good long term stability was observed.  相似文献   

2.
Liu H  Yuan R  Chai Y  Mao L  Yang X  Zhuo Y  Yuan Y 《Talanta》2011,84(2):387-392
A new electrochemiluminescence (ECL) detector for capillary electrophoresis (CE) based on tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) immobilized in Nafion/PTC-NH2 (an ammonolysis product of 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA)) composite film was presented for the first time. The Nafion/PTC-NH2 composite film could effectively immobilize tris(2,2′-bipyridyl)ruthenium(II) via ion-exchange and electrostatic interaction. Cyclic voltammetric and ECL behavior of Nafion/PTC-NH2/Ru composite film was investigated compared to Nafion/Ru composite. The Nafion/PTC-NH2/Ru composite film exhibited good ECL stability and simple operability. Then the CE with solid-state ECL detector system was successfully used to detect sophora - a quinolizidine type - alkaloids as sophoridine (SR) and matrine (MT). The CE-ECL parameters that affected separation and detection were optimized. Under the optimized conditions, the linear range was from 2.5 × 10−8 to 2 × 10−6 mol/L for SR, 1.0 × 10−8 to 1.0 × 10−6 mol/L for MT. The detection limit (S/N = 3) was estimated to be 5 × 10−9 and 10−9 mol/L for SR and MT, respectively. It was shown that the CE coupling with solid-state ECL detector system exhibited satisfying sensitivity of analysis.  相似文献   

3.
本文根据氧分子能有效地猝灭金属有机络合物的荧光的原理,研制了一种氧传感器。  相似文献   

4.
An effective electrochemiluminescence (ECL) sensor based on Nafion/poly(sodium 4-styrene sulfonate) (PSS) composite film-modified ITO electrode was developed. The Nafion/PSS/Ru composite film was characterized by atomic force microscopy, UV-vis absorbance spectroscopy and electrochemical experiments. The Nafion/PSS composite film could effectively immobilize tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) via ion-exchange and electrostatic interaction. The ECL behavior of Ru(bpy)32+ immobilized in Nafion/PSS composite film was investigated using tripropylamine (TPA) as an analyte. The detection limit (S/N = 3) for TPA at the Nafion/PSS/Ru composite-modified electrode was estimated to be 3.0 nM, which is 3 orders of magnitude lower than that obtained at the Nafion/Ru modified electrode. The Nafion/PSS/Ru composite film-modified indium tin oxide (ITO) electrode also exhibited good ECL stability. In addition, this kind of immobilization approach was simple, effective, and timesaving.  相似文献   

5.
It is shown that microenvironments formed around catalytically active sites mitigate catalyst deactivation by biogenic impurities that are present during the production of biorenewable chemicals from biologically derived species. Palladium and ruthenium catalysts are inhibited by the presence of sulfur‐containing amino acids; however, these supported metal catalysts are stabilized by overcoating with poly(vinyl alcohol) (PVA), which creates a microenvironment unfavorable for biogenic impurities. Moreover, deactivation of Pd catalysts by carbon deposition from the decomposition of highly reactive species is suppressed by the formation of bimetallic PdAu nanoparticles. Thus, a PVA‐overcoated PdAu catalyst was an order of magnitude more stable than a simple Pd catalyst in the hydrogenation of triacetic acid lactone, which is the first step in the production of biobased sorbic acid. A PVA‐overcoated Ru catalyst showed a similar improvement in stability during lactic acid hydrogenation to propylene glycol in the presence of methionine.  相似文献   

6.
A series of VTES/TEOS composite xerogels covalently grafted with a novel complex Ru(phen)2(Dppz-Si)Cl2 were prepared, using the alkoxysilane-modified dipyrido[3,2-a:2′,3′-c]phenazine compound (denoted as Dppz-Si) as the second ligand of the Ru(phen)2Cl2 (phen = 1,10-phenanthroline) complex and a precursor of the sol–gel process. Bulk xerogels were obtained by co-hydrolyzing and co-condensation from a mixture of triethoxysilane (TEOS), Ru(phen)2(Dppz-Si)Cl2 and Vinyltriethoxysilane (VTES). The luminescence intensity of composite xerogels is enhanced by 18.2 times, and the sensitivity is improved from 1.1 to 3.1 by optimizing the molar ratio of VTES to TEOS. The composite xerogel containing 80% VTES in precursor was optimal, exhibiting the maximum luminescence intensity and sensitivity. These results indicate that the complex Ru(phen)2(Dppz-Si)Cl2 is sensitive to oxygen concentration, VTES is a kind of excellent organic modifier and can greatly improved photoluminescent (PL) and oxygen sensing performances.  相似文献   

7.
Herein, highly efficient solid-state ECL sensor was introduced for the first time onto the screen printed electrodes of the paper-based chips (PCs) based on the composite film of poly(sodium 4-styrenesulfonate) functionalized graphene (PSSG) and Nafion. Attributed to the cooperative characteristics of both PSS and graphene, PSSG ensured both effective Ru(bpy)32+ immobilization and fast electron transfer of Ru(bpy)32+ in the composite film. The ECL behaviors at the developed sensor were investigated using tripropylamine as a representative analyte and low detection limit (S N−1 = 3) of 5.0 nM was obtained. It also exhibited more excellent reproducibility (relative standard deviations of 0.63% for continuous 45 cycles) and long-term stability (∼80% of its initial ECL intensity could be retained over 3 months). More importantly, assisted by the developed ECL sensor, discrimination of 1.0 nM single-nucleotide mismatch in human urine matrix could be realized on the PCs for the first attempt. Thus, the developed sensor was confirmed with the advantages of highly sensitivity, long-term stability, simplicity, low cost, disposability, high efficiency and potential applicability.  相似文献   

8.
A new ordered mesoporous carbon (OMC) composite modified electrode was fabricated for the first time. Binuclear cobalt phthalocyaninehexasulfonate sodium salt (bi-CoPc) can be adsorbed onto didodecyldimethylammonium bromide (DDAB)/OMC film by ion exchange. UV-vis spectroscopy, scanning electron microscopy (SEM) and electrochemical methods were used to characterize the composite film. The cyclic voltammograms demonstrate that the charge transfer of bi-CoPc is promoted by the presence of OMC. Further study indicated that bi-CoPc/DDAB/OMC film is the excellent electrocatalyst for the electrochemical reduction of oxygen in a neutral aqueous solution and hemoglobin (Hb) at lower concentrations. Additionally, as an amperometric 2-mercaptoethanol (2-ME) sensor, this modified electrode shows a wider linear range (2.5 × 10−6 to 1.4 × 10−4 M), high sensitivity (16.5 μA mM−1) and low detection limit of 0.6 μM (S/N = 3). All these confirm the fact that the new composite film may have wide potential applications in biofuel cells, biological and environmental sensors.  相似文献   

9.
Tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) has been successfully immobilized onto electrode through the electrodeposition of Ru(bpy)32+/AuNPs/chitosan composite film. In the experiments, chitosan solution was first mixed with Au nanoparticles (AuNPs) and Ru(bpy)32+. Then, during chronopotentiometry experiments in this mixed solution, a porous 3D network structured film containing Ru(bpy)32+, AuNPs and chitosan has been electrodeposited onto cathode due to the deposition of chitosan when pH value is over its pKa (6.3). The applied current density is crucial to the film thickness and the amount of the entrapped Ru(bpy)32+. Additionally, these doping Ru(bpy)32+ in the composite film maintained their intrinsic electrochemical and electrochemiluminescence activities. Consequently, this Ru(bpy)32+/AuNPs/chitosan modified electrode has been used in ECL to detect tripropylamine, and the detection limit was 5 × 10−10 M.  相似文献   

10.
Chun Li 《Tetrahedron》2004,60(37):8037-8041
It has been confirmed that octasulfonatocalix[8]arene (Calx-S8) and tris(2,2′-bipyridine)ruthenium (II) (Ru(bpy)32+) can form a stable host-guest complex in aqueous solution. The binding constant for 1:1 [Calx-S88−·Ru(bpy)32+]6− complex formation was estimated to be (2.4±0.8)×104 dm3 mol−1 by fluorescence titration, which indicates that the [Calx-S88−·Ru(bpy)32+]6− complex is the main species in 1:1 molar ratio aqueous solution of Calx-S8 and Ru(bpy)32+. In situ UV-Vis spectroscopic measurements indicated that Ru(bpy)32+ complexes can be readily deposited onto ITO electrode through electrochemical polymerization of 3,4-ethylenedioxythiophene (EDOT) using [Calx-S88−·Ru(bpy)32+]6− host-guest complex as a dopant anion owing to the electrostatic interaction between the cationic conductive polymer and the anionic host-guest complex. The loading degree of the composite film with Ru(bpy)32+ can be determined by Lambert-Beer law modified for the two-dimensional concentration. The obtained composite film showed good photoelectric conversion properties in response to visible light irradiation. This is a novel photocurrent generation system in which the photoexcited state energy is efficiently collected by the conductive polymeric layer.  相似文献   

11.
A highly sensitive and stable tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)32+ immobilized in the ECL sensor by adsorption of Ru(bpy)32+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both titania-Nafion composite films without CNT and pure Nafion films. The present Ru(bpy)32+ ECL sensor based on the MWCNT-titania--Nafion composite gave a linear response (R2 = 0.999) for TPA concentration from 50 nM to 1.0 mM with a remarkable detection limit (S/N = 3) of 10 nM while the ECL sensors based on titania-Nafion composite without MWCNT, pure Nafion films, and MWCNT-Nafion composite gave a detection limit of 0.1 μM, 1 μM, and 50 nM, respectively. The present ECL sensor showed outstanding long-term stability (no signal loss for 4 months).  相似文献   

12.
A two-step sol-gel technique was used here to prepare a carbon ceramic electrode modified with nafion and [Ru(bpy)(tpy)Cl]PF6. This involves two steps: first, forming a bulk-modified carbon ceramic electrode with nafion, and then immersing the electrode into a Ru-complex solution (electroless deposition) for a short period of time (5-25 s). Cyclic voltammograms of the resulting surface-modified carbon ceramic electrode show stable and a well-defined redox couple due to Ru(II)/Ru(III) system with surface-confined characteristic. l-Cysteine (CySH) has been chosen as a model to elucidate the electrocatalytic ability of Ru-complex nafion sol-gel composite electrode. Not only the modified electrode shows excellent catalytic activity toward l-cysteine electrooxidation in pH range 3-9, but the antifouling effect of nafion film also increases the reproducibility of results in comparison with CCE modified with homogeneous mixing of graphite powder and Ru-complex (one step sol-gel method). Under the optimized conditions in amperometry method, the concentration calibration range, detection limit and sensitivity were 0.1-100 μM, 20 nM and 50 nA/μM, respectively. The advantages of this modified electrode are good reproducibility, excellent catalytic activity, simplicity of preparation and especially its antifouling properties towards l-cysteine and its oxidation products. Additionally, it is promising as a detector in flow system or chromatography systems.  相似文献   

13.
Li Mao  Ruo Yuan  Yaqin Chai  Xia Yang 《Talanta》2010,80(5):1692-4551
An effective method for immobilization of Ru(bpy)32+ on glassy carbon electrode surface (GCE) is developed for the preparation of a novel electrochemiluminescence sensor. First of all, the positively charged Ru(bpy)32+ is modified on the surface of negatively charged gold nanoparticles (nano-Au) via the electrostatic interactions to obtain the Ru(bpy)32+/nano-Au nano-sphere (abbreviate as Ru-AuNPs). Subsequently, the large amount of Ru-AuNPs are immobilized on the multi-wall carbon nanotubes (MWCNTs)-Nafion homogeneous composite coated GCE by dual interaction: firstly, the Nafion, a kind of typical cation-exchange membrane, can absorb the Ru-AuNPs as the enrichment of cation Ru(bpy)32+ on the Ru-AuNPs surface; secondly, the employment of carboxylic MWCNTs in the Nafion film can also chemosorb the Ru(bpy)32+ cation on the Ru-AuNPs surface to increase the carrier content. At the same time, the experiment confirms that the enhancement of the ECL intensity on the sensor is attributed to following reasons. One hand, the employment of MWCNTs in the Nafion film enlarged the electro-active surface areas to benefit the contact between the signal probe on the composite film and coreactant used as reinforcing agent. On the other hand, the nano-materials of MWCNTs and nano-Au also improve the conductivity of the assembled film to increase the quantity of excited state of Ru(bpy)32+ in the unit time under the electrochemical condition and finally cause better properties in luminescence. In the experiment, the influence of the coreactant tripropylamine (TPA) on proposed ECL sensor is investigated. The logarithm of ECL intensity is proportional to the logarithm of TPA concentration on the range of 4 × 10−10 M to 2.8 × 10−6 M and 2.8 × 10−6 M to 0.71 × 10−3 M. After optimizing these conditions, the ECL sensor with TPA as coreactant is employed to detect a kind of alkaloid medicine, Matrine, for evaluating the practical application in the medicine analysis. The present sensor with TPA as coreactant shows the good response to the medicine concentration of the Matrine from 2.0 × 10−6 M to 6.0 × 10−3 M, which is used to detect the Matrine concentration in the Matrine injection.  相似文献   

14.
A compact photoluminescence (PL)-based O2 sensor utilizing an organic light emitting device (OLED) as the light source is described. The sensor device is structurally integrated. That is, the sensing element and the light source, both typically thin films that are fabricated on separate glass substrates, are attached back-to-back. The sensing elements are based on the oxygen-sensitive dyes Pt- or Pd-octaethylporphyrin (PtOEP or PdOEP, respectively), which are embedded in a polystyrene (PS) matrix, or dissolved in solution. Their performance is compared to that of a sensing element based on tris(4,7-diphenyl-l,10-phenanthroline) Ru II (Ru(dpp)) embedded in a sol-gel film. A green OLED light source, based on tris(8-hydroxy quinoline Al (Alq3), was used to excite the porphyrin dyes; a blue OLED, based on 4,4'-bis(2,2'-diphenylviny1)-1,1'-biphenyl, was used to excite the Ru(dpp)-based sensing element. The O2 level was monitored in the gas phase and in water, ethanol, and toluene solutions by measuring changes in the PL lifetime tau of the O2-sensitive dyes. The sensor performance was evaluated in terms of the detection sensitivity, dynamic range, gas flow rate, and temperature effect, including the temperature dependence of tau in pure Ar and O2 atmospheres. The dependence of the sensitivity on the preparation procedure of the sensing film and on the PS and dye concentrations in the sensing element, whether a solid matrix or solution, were also evaluated. Typical values of the detection sensitivity in the gas phase, S(g) identical with tau(0% O2)/tau(100% O2), at 23 degrees C, were approximately 35 to approximately 50 for the [Alq3 OLED[/[PtOEP dye] pair; S(g) exceeded 200 for the Alq3/PdOEP sensor. For dissolved oxygen (DO) in water and ethanol, S(DO) (defined as the ratio of tau in de-oxygenated and oxygen-saturated solutions) was approximately 9.5 and approximately 11, respectively, using the PtOEP-based film sensor. The oxygen level in toluene was measured with PtOEP dissolved directly in the solution. That sensor exhibited a high sensitivity, but a limited dynamic range. Effects of aggregation of dye molecules, sensing film porosity, and the use of the OLED-based sensor arrays for O2 and multianalyte detection are also discussed.  相似文献   

15.
Conductive composite film which contains nafion (NF) doped multi-walled carbon nanotubes (MWCNTs) along with the incorporation of poly(malachite green) (PMG) has been synthesized on glassy carbon electrode (GCE), gold and indium tin oxide (ITO) electrodes by potentiostatic methods. The presence of MWCNTs in the composite film (MWCNTs-NF-PMG) enhances surface coverage concentration (Γ) of PMG to ≈396%, and increases the electron transfer rate constant (ks) to ≈305%. Similarly, electrochemical quartz crystal microbalance study reveals the enhancement in the deposition of PMG at MWCNTs-NF film. The surface morphology of the composite film deposited on ITO electrode has been studied using scanning electron microscopy (SEM) and scanning tunneling microscopy (STM). These two techniques reveal that the PMG incorporated on MWCNTs-NF film. The MWCNTs-NF-PMG composite film also exhibits promising enhanced electrocatalytic activity towards the simple aliphatic alcohols such as methanol, ethanol and propanol. The electroanalytical responses of analytes at NF-PMG and MWCNTs-NF-PMG films were measured using both cyclic voltammetry (CV) and differential pulse voltammetry (DPV). From electroanalytical studies, well defined voltammetric peaks have been obtained at MWCNTs-NF-PMG composite film for methanol, ethanol and propanol at Epa = 609, 614 and 602 mV respectively. The sensitivity of MWCNTs-NF-PMG composite film towards methanol, ethanol and propanol in CV technique are 0.59, 0.36 and 0.92 μA mM−1 cm−2 respectively, which are higher than NF-PMG film. Further, the sensitivity values obtained using DPV are higher than the values obtained using CV technique.  相似文献   

16.
This paper presents a highly sensitive oxygen sensor that comprises an optical fiber coated at one end with platinum(II) meso-tetrakis(pentafluorophenyl)porphyrin (PtTFPP) and PtTFPP entrapped core-shell silica nanoparticles embedded in an n-octyltriethoxysilane (Octyl-triEOS)/tetraethylorthosilane (TEOS) composite xerogel. The sensitivity of the optical oxygen sensor is quantified in terms of the ratio I0/I100, where I0 and I100 represent the detected fluorescence intensities in pure nitrogen and pure oxygen environments, respectively. The experimental results show that the oxygen sensor has a sensitivity (I0/I100) of 166. The response time was 1.3 s when switching from pure nitrogen to pure oxygen, and 18.6 s when switching in the reverse direction. The experimental results show that compared to oxygen sensors based on PtTFPP, PtOEP, or Ru(dpp)32+ dyes, the proposed optical fiber oxygen sensor has the highest sensitivity. In addition to the increased surface area per unit mass of the sensing surface, the dye entrapped in the core of silica nanoparticles also increases the sensitivity because a substantial number of aerial oxygen molecules penetrate the porous silica shell. The dye entrapped core-shell nanoparticles is more prone to oxygen quenching.  相似文献   

17.
Lam H  Rao G  Loureiro J  Tolosa L 《Talanta》2011,84(1):65-70
In measuring specific conditions in the real world, there are many situations where both the oxygen concentration and the temperature have to be determined simultaneously. Here we describe a dual optical sensor for oxygen and temperature that can be adapted for different applications. The measurement principle of this sensor is based on the luminescence decay times of the oxygen-sensitive ruthenium complex tris-4,7-diphenyl-1,10-phenanthroline ruthenium(III) [Rudpp] and the temperature-sensitive europium complex tris(dibenzoylmethane) mono(5-amino-1,10-phenanthroline)europium(III) [Eudatp]. The excitation and emission spectra of the two luminophores overlap significantly and cannot be discriminated in the conventional way using band pass filters or other optical components. However, by applying both the frequency and time domain techniques, we can separate the signals from the individual decay time of the complexes. The europium complex is entrapped in a poly(methyl methacrylate) (PMMA) layer and the ruthenium complex is physically adsorbed on silica gel and incorporated in a silicone layer. The two layers are attached to each other by a double sided silicone based tape. The europium sensing film was found to be temperature-sensitive between 10 and 70 °C and the ruthenium oxygen-sensitive layer can reliably measure between 0 and 21% oxygen.  相似文献   

18.
Chang G  Tatsu Y  Goto T  Imaishi H  Morigaki K 《Talanta》2010,83(1):61-65
Optical biosensor arrays for rapidly determining the glucose concentrations in a large number of beverage and blood samples were developed by immobilizing glucose oxidase (GOD) on oxygen sensor layer. Glucose oxidase was first encapsulated in silica based gels through sol-gel approach and then immobilized on 96-well microarrays integrated with oxygen sensing film at the bottom. The oxygen sensing film was made of an organically modified silica film (ORMOSIL) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium dichloride (Ru(dpp)3Cl2). The oxidation reaction of glucose by glucose oxidase could be monitored through fluorescence intensity enhancement due to the oxygen consumption in the reaction. The luminescence changing rate evaluated by the dynamic transient method (DTM) was correlated with the glucose concentration with the wide linear range from 0.1 to 5.0 mM (Y = 13.28X − 0.128, R = 0.9968) and low detection limit (0.06 mM). The effects of pH and coexisting ions were systemically studied. The results showed that the optical biosensor arrays worked under a wide range of pH value, and normal interfering species such as Na+, K+, Cl, PO43−, and ascorbic acid did not cause apparent interference on the measurement. The activity of glucose oxidase was mostly retained even after 2-month storage, indicating their long-term stability.  相似文献   

19.
This paper reports the utilization of triangular silver nanoplates (TSNPs) to enhance the sensitivity of surface plasmon resonance (SPR) biosensor. TSNPs modified with 3-mercaptopropinic acid (MPA) were simply mixed with chitosan and glutaraldehyde to form TSNPs/chitosan composite. The composite was deposited on Au film as immobilization substrate for SPR biosensor. The novel structures of TSNPs are preserved against etching by MPA and chitosan polymer. Moreover, chitosan cross-linked by glutaraldehyde enables antibody to be immobilized on fabricated substrate directly via Schiff alkali reaction. In the optimized conditions, the resulting biosensor based on TSNPs/chitosan composite shows a satisfactory response to bovine IgG in the concentration range of 0.075–40.00 μg mL−1. While the biosensor based on chitosan without TSNPs shows a response in the concentration range of 0.6–40 μg mL−1 and the biosensor based on Au film shows a response in the concentration range of 2.5–40 μg mL−1. The experiment results show that the sensitivity of SPR biosensor based on TSNPs/chitosan composite was significantly enhanced and the immobilization procedure of antibody was simplified.  相似文献   

20.
Polarization-based oxygen sensor   总被引:2,自引:0,他引:2  
A new approach to oxygen sensing based on the luminescence polarization observed from a novel type of sensor is described. The oxygen sensor consists of an oxygen-sensitive silicone film containing tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) chloride [Ru(dpp)3Cl2] and an oxygen-insensitive film of Styryl 7 in poly(vinyl alcohol). Polarizers are used to select orthogonally polarized emission components from Ru(dpp)3Cl2 and Styryl 7. The polarization of the combined emission was found to be highly sensitive to the partial pressure of oxygen. This method of polarization sensing is generic and can be used with any fluorophore which displays an analyte-dependent change in intensity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号