首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In recent years, despite the increasing success of liquid chromatography (LC) coupled to tandem mass spectrometry (MS), reports on matrix susceptibility have shown the limitations of the this powerful analytical technique. Matrix effects (MEs) result from co-eluting residual matrix components affecting the ionization efficiency of target analytes and can lead to erroneous results. The present work evaluates the matrix effect of environmental water samples on 35 endocrine disrupting chemicals (EDCs) in negative and positive LC-ESI-MS/MS. It was shown that mobile-phase additives could significantly influence matrix effects. Addition of acids resulted in a severe signal suppression (average ME%: <65%), and 1 mM ammonium formate increased the average ME% to 84%. The importance of an efficient sample clean-up and internal standardization also was demonstrated. Cleaner extracts resulted in reduced matrix effects (average ME%: 89%) and labeled internal standards proved to have a beneficial effect especially on signal reproducibility (average CV% 4.2% versus 2.6%). The results from the present work indicate that evaluation of matrix effects should become an integrated part of quantitative LC-ESI-MS/MS method development and validation.  相似文献   

2.
Two new ultra-high performance liquid chromatography (UHPLC) methods for analyzing 21 selected antivirals and their metabolites were optimized, including sample preparation step, LC separation conditions, and tandem mass spectrometry detection. Micro-solid phase extraction in pipette tips was used to extract antivirals from the biological material of Hanks balanced salt medium of pH 7.4 and 6.5. These media were used in experiments to evaluate the membrane transport of antiviral drugs. Challenging diversity of physicochemical properties was overcome using combined sorbent composed of C18 and ion exchange moiety, which finally allowed to cover the whole range of tested antivirals. For separation, reversed-phase (RP) chromatography and hydrophilic interaction liquid chromatography (HILIC), were optimized using extensive screening of stationary and mobile phase combinations. Optimized RP-UHPLC separation was carried out using BEH Shield RP18 stationary phase and gradient elution with 25 mmol/L formic acid in acetonitrile and in water. HILIC separation was accomplished with a Cortecs HILIC column and gradient elution with 25 mmol/L ammonium formate pH 3 and acetonitrile. Tandem mass spectrometry (MS/MS) conditions were optimized in both chromatographic modes, but obtained results revealed only a little difference in parameters of capillary voltage and cone voltage. While RP-UHPLC-MS/MS exhibited superior separation selectivity, HILIC-UHPLC-MS/MS has shown substantially higher sensitivity of two orders of magnitude for many compounds. Method validation results indicated that HILIC mode was more suitable for multianalyte methods. Despite better separation selectivity achieved in RP-UHPLC-MS/MS, the matrix effects were noticed while using both chromatographic modes leading to signal enhancement in RP and signal suppression in HILIC.  相似文献   

3.
The application of LC separation and mobile phase additives in addressing LC-MS/MS matrix signal suppression effects for the analysis of pesticides in a complex environmental matrix was investigated. It was shown that signal suppression is most significant for analytes eluting early in the LC-MS analysis. Introduction of different buffers (e.g. ammonium formate, ammonium hydroxide, formic acid) into the LC mobile phase was effective in improving signal correlation between the matrix and standard samples. The signal improvement is dependent on buffer concentration as well as LC separation of the matrix components. The application of LC separation alone was not effective in addressing suppression effects when characterizing complex matrix samples. Overloading of the LC column by matrix components was found to significantly contribute to analyte-matrix co-elution and suppression of signal. This signal suppression effect can be efficiently compensated by 2D LC (LC-LC) separation techniques. The effectiveness of buffers and LC separation in improving signal correlation between standard and matrix samples is discussed.  相似文献   

4.
The application of LC separation and mobile phase additives in addressing LC-MS/MS matrix signal suppression effects for the analysis of pesticides in a complex environmental matrix was investigated. It was shown that signal suppression is most significant for analytes eluting early in the LC-MS analysis. Introduction of different buffers (e.g. ammonium formate, ammonium hydroxide, formic acid) into the LC mobile phase was effective in improving signal correlation between the matrix and standard samples. The signal improvement is dependent on buffer concentration as well as LC separation of the matrix components. The application of LC separation alone was not effective in addressing suppression effects when characterizing complex matrix samples. Overloading of the LC column by matrix components was found to significantly contribute to analyte-matrix co-elution and suppression of signal. This signal suppression effect can be efficiently compensated by 2D LC (LC-LC) separation techniques. The effectiveness of buffers and LC separation in improving signal correlation between standard and matrix samples is discussed.  相似文献   

5.
The study presents for the first time a systematic investigation of matrix effects in the LC-MS/MS analysis of ergot alkaloids in cereals. In order to assure the accuracy of the results, several approaches to minimize/eliminate matrix effects were investigated including variation of ionization techniques, chromatography and sample preparation on different grain types and grain varieties. It was revealed that the use of UPLC and careful choice of sample preparation might reduce signal suppression/enhancement. In general, ergometrine was found to be the most susceptible among the ergot alkaloids studied, but none of the used approaches suggested a total elimination of matrix effects; only less than half of its MS signal could be recovered. The late-eluting compounds were less affected by matrix components in all conditions tested. Further, the robustness of the applied LC-MS method was checked by means of a fractional factorial design. The results indicate that small changes to the sample preparation parameters, namely pH and concentration of extraction buffer, shaking time, drying temperature and extraction volumes, did not significantly (α?=?0.05) affect the recoveries of ergot alkaloids.
Figure
SSE (%) applying different sample preparation procedures  相似文献   

6.
提出使用甲酸甲胺作为新型电离增强剂改善反相液相色谱-电喷雾质谱(LC-ESI-MS)检测甘油三酯灵敏度的方法.使用反相C18色谱柱,以玉米油的异丙醇溶液为样品,选择文献中常用的异丙醇-乙腈-甲醇-水,异丙醇-乙腈流动相,在考察甲酸、乙酸、甲酸铵、乙酸铵、甲酸丁胺、甲酸二丁胺、甲酸三乙胺、甲酸二乙胺、甲酸甲胺、甲酸乙胺等不同电离增强剂的基础上,比较了甲酸甲胺和常用的甲酸铵电离增强剂对LC-ESI-MS分析甘油三酯检测灵敏度的影响,结果表明,甲酸甲胺可以使其中三亚油酸甘油酯组分的质谱峰响应值和信噪比均约为使用甲酸铵的5倍.考察了使用甲酸甲胺时,甲酸甲胺电离增强剂的浓度、流动相流速以及雾化气流速对检测的影响.通过测定不同玉米油浓度与其中甘油三酯总离子流色谱峰面积的关系曲线,显示玉米油中甘油三酯组分在不同流动相的电喷雾过程中出现聚集的最小浓度相差不大,三亚油酸甘油酯峰面积与浓度在7×10-7~2×10-4 mol/L范围内的线性关系较好,相关系数R2=0.9997,在更高的浓度时则峰面积增加缓慢.根据实验数据分析甲酸甲胺改进检测的机理,提出含有疏水性基团的加合甲胺单电荷离子具有较低的溶剂化能,在雾滴表面富集的加合甲胺离子容易被蒸发,从而提高了电喷雾离子化效率.本方法为LC-ESI-MS分析食用油中甘油三酯时提高检测灵敏度提供了有效途径.  相似文献   

7.
The combination of capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) via a triaxial interface was studied as a potential means for the characterization of intact proteins. To evaluate the possibility to use a nonvolatile electrolyte for CE, the effect of sodium phosphate and ammonium borate on the MS signal of the proteins insulin, myoglobin, and bovine serum albumin (BSA) was investigated by employing infusion experiments, and compared to the effect of ammonium formate and formic acid. The study shows that with formic acid (50 mM, pH 2.4) the most intense protein signals were obtained, while the use of sodium phosphate buffer (5 and 10 mM, pH 7.5) almost completely diminished the MS response. Ammonium formate and ammonium borate (up to 100 mM, pH 8.5) also caused protein ion suppression, but especially with the borate buffer significant MS intensity remained. MS analysis of myoglobin revealed the loss of the heme group when an acidic CE electrolyte was used. Using a background electrolyte containing 25 mM ammonium borate (pH 8.5), it is demonstrated that a CE separation of a protein test mixture can be monitored with ESI-MS without degrading the MS performance allowing molecular weight determinations of the separated compounds. In the presence of borate, detection limits were estimated to be 5-10 microM (ca. 100 fmol injected). The usefulness of the CE-MS system employing a borate buffer is indicated by the analysis of a stored sample of BSA revealing several degradation products. A sample of placental alkaline phosphatase (PLAP), a potential therapeutic agent, was also analyzed by CE-MS indicating the presence of a protein impurity. Probably due to insufficient ionization of the PLAP (a complex glycoprotein), no MS signals of the intact protein were observed.  相似文献   

8.
The aim of this study was developing a supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS) method and an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method, for the analysis of N-acetyl-serotonin (NAS) and melatonin (Mel) in human serum, and to compare the performance of these methods. Deuterated isotopologues of the neurotransmitters were synthesized and evaluated for suitability as internal standards in sample preparation. Liquid-liquid extraction was selected as sample preparation procedure. With chloroform, the best extraction solvent tested, an extraction yield of 48 ± 2% for N-acetyl-serotonin and 101 ± 10% for melatonin was achieved. SFC separation was accomplished within 3 min on a BEH stationary phase, employing isocratic elution with 90% carbon dioxide and 0.1% formic acid as well as 0.05% ammonium formate in methanol. For the 4 min UHPLC gradient separation with 0.1% formic acid in water and methanol, respectively, a Kinetex XB-C18 was used as stationary phase. Both chromatographic techniques were optimized regarding mobile phase composition, additives to the mobile phase and column temperature. Multiple reaction monitoring (MRM) analysis was used for quantification of the metabolites. Both methods were validated regarding retention time stability, LOD, LOQ, repeatability and reproducibility of quantification, process efficiency, extraction recovery and matrix effects. LOD and LOQ were 0.017 and 0.05 pg μL−1 for NAS and 0.006 and 0.018 pg μL−1 for Mel in SFC-MS/MS compared to 0.028 and 0.1 pg μL−1 for NAS and 0.006 and 0.017 pg μL−1 for Mel in UHPLC-MS/MS.  相似文献   

9.
A hydrophilic interaction chromatography‐tandem mass spectrometric method (HILIC/MS/MS) for the determination of irbesartan in human plasma was developed. Irbesartan and losartan (internal standard) were extracted from human plasma with ethyl acetate at acidic pH. The analytes were analyzed on a Luna HILIC column with the mobile phase of ACN–ammonium formate (50 mM, pH 6.5) (96:4, v/v) and detected by ESI MS/MS in the selected reaction monitoring mode. The standard curve was linear (r2 = 0.9981) over the concentration range of 10–2500 ng/mL and the lower LOQ was 10 ng/mL using 100 μL of plasma sample. The CV and relative error for intra‐ and interassay at four QC levels were 2.9 to 8.1% and –2.7 to 2.3%, respectively. There were less absolute and relative matrix effects for irbesartan and losartan. The present method was successfully applied to the pharmacokinetic study of irbesartan after oral dose of irbesartan (150 mg tablet) to male healthy volunteers.  相似文献   

10.
The potential of solid phase extraction (SPE) clean-up has been assessed to reduce matrix effects (signal suppression or enhancement) in the liquid chromatography-tandem mass spectrometry (LC–MS/MS) analysis of lipophilic marine toxins. A large array of ion-exchange, silica-based, and mixed-function SPE sorbents was tested. Polymeric sorbents were found to retain most of the toxins. Optimization experiments were carried out to maximize recoveries and the effectiveness of the clean-up. In LC–MS/MS analysis, the observed matrix effects can depend on the chromatographic conditions used, therefore, two different HPLC methods were tested, using either an acidic or an alkaline mobile phase. The recovery of the optimized SPE protocol was around 90% for all toxins studied and no break-through was observed. The matrix effects were determined by comparing signal response from toxins spiked in crude and SPE-cleaned extracts with those derived from toxins prepared in methanol. In crude extracts, all toxins suffered from matrix effects, although in varying amounts. The most serious effects were observed for okadaic acid (OA) and pectenotoxin-2 (PTX2) in the positive electrospray ionization mode (ESI+). SPE clean-up on polymeric sorbents in combination with the alkaline LC method resulted in a substantial reduction of matrix effects to less than 15% (apparent recovery between 85 and 115%) for OA, yessotoxin (YTX) in ESI and azaspiracid-1 (AZA1), PTX2, 13-desmethyl spirolides C (SPX1), and gymnodimine (GYM) in ESI+. In combination with the acidic LC method, the matrix effects after SPE were also reduced but nevertheless approximately 30% of the matrix effects remained for PTX2, SPX1, and GYM in ESI+. It was concluded that SPE of methanolic shellfish extracts can be very useful for reduction of matrix effects. However, the type of LC and MS methods used is also of great importance. SPE on polymeric sorbents in combination with LC under alkaline conditions was found the most effective method.  相似文献   

11.
An analytical method was developed for the detection of toldimfos sodium residues in porcine muscle and bovine milk using liquid chromatography–triple quadrupole tandem mass spectrometry (LC–MS/MS) analysis. The drug was extracted from muscle and milk using 10 mm ammonium formate in acetonitrile and then purified using n ‐hexane. The drug was well separated on a Luna C18 column using a mixture of 10 mm ammonium formate in ultrapure water (A) and acetonitrile (B) as the mobile phase. Good linearity was achieved over the tested concentration range (0.005–0.03 mg/kg) in matrix‐matched standard calibration. The determination coefficients (R 2 ) were 0.9942 and 0.9898 for muscle and milk, respectively. Fortified porcine muscle and bovine milk contained concentrations equivalent to and twice the limit of quantification (0.005 mg/kg) yielded recoveries in the range of 75.58–89.74% and relative standard deviations of ≤8.87%. Samples collected from large markets located in Seoul, Republic of Korea, tested negative for toldimfos sodium residue. In conclusion, ammonium formate in acetonitrile can effectively extract toldimfos sodium from porcine muscle and bovine milk without solid‐phase extraction, which is usually required for cleanup before analysis. This method can be applied for the routine analysis of toldimfos in foods of animal origins.  相似文献   

12.
We present a fast liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the analysis of the coccidiostat amprolium in food samples. Tandem mass spectrometry in a triple quadrupole was used for quantitative purposes, and the information from multiple-stage mass spectrometry in an ion-trap mass analyzer contributed to fragmentation studies. Hydrophilic interaction liquid chromatography (HILIC) in a Fused-Core™ column using isocratic elution (acetonitrile:formic acid/ammonium formate buffer pH 4, 50 mM (60:40)) successfully analyzed this compound in less than 3 min. The HILIC system was coupled to heated electrospray-MS/MS using highly selective-selected reaction monitoring (H-SRM) to improve sensitivity and selectivity for the analysis of amprolium, after a simple sample treatment based on an “extract and shoot” strategy. Accurate mass measurements were performed to identify the interfering compound responsible for causing matrix ion enhancement in the signal of amprolium. The addition of l-carnitine (the interfering compound) (1 μg L−1) to standards and sample extracts allowed the use of the external calibration method for quantitative purposes. The LC–MS/MS (H-SRM) method showed good precision (relative standard deviation, RSD, lower than 13%), accuracy and linearity and allowed the determination of amprolium down to the ppb level (LODs between 0.1 and 0.6 μg kg−1).  相似文献   

13.

A comprehensive survey of matrix effects on the LC–MS/MS analysis of the banned antibiotic growth promoters carbadox and olaquindox in feed was carried out. Various factors of sample preparation procedure and measurement were systematically investigated by pre- and post-extraction addition and postcolumn infusion experiments. In general, strong signal suppression up to 70 % for carbadox and up to 90 % for olaquindox was observed when using different extraction solvents and techniques as well as different chromatographic conditions. Reduction of matrix effects was achieved by SPE clean-up and dilution of sample extracts. Nevertheless, matrix effect profiles determined by postcolumn infusion revealed, that reduction of signal suppression at a respective retention time cannot guarantee improvement of the methods performance. If high variability of matrix effects is present along the chromatographic run, accuracy might decrease despite reduced signal suppression. Besides method parameters, different feedingstuffs were investigated and showed similar matrix effects.

  相似文献   

14.
张莹  陆豪杰  杨芃原 《中国化学》2008,26(10):1863-1869
本文建立了以磷酸铵盐为添加剂的基质新系统,增强了磷酸化肽在MALDI正离子模式下的离子化。系统地考察了不同的磷酸盐以及不同的盐浓度对磷酸化肽离子化效率的影响。考察了两种适合于磷酸化肽离子化的基质类型2,5-二羟基苯甲酸和2,4,6-三羟基苯乙酮。用2,5-二羟基苯甲酸作为基质时,当加入10 mM 磷酸氢二铵时,磷酸化蛋白质β-casein的磷酸肽 48FQ[pS]EEQQQTEDELQDK63的离子化效率可以增强5-8倍,当加入10 mM磷酸二氢胺时,磷酸肽的离子化效率可以增强3-4倍。用2,4,6-三羟基苯乙酮作为基质时,当加入5mM磷酸氢二铵时,磷酸化肽的离子化效率比文献报道的最有利于磷酸化肽离子化的基质体系增强了2倍。并探讨了铵根离子和磷酸根离子促进磷酸化肽在MALDI的正离子模式下离子化效率的机理。  相似文献   

15.
A comprehensive survey of matrix effects on the LC–MS/MS analysis of the banned antibiotic growth promoters carbadox and olaquindox in feed was carried out. Various factors of sample preparation procedure and measurement were systematically investigated by pre- and post-extraction addition and postcolumn infusion experiments. In general, strong signal suppression up to 70 % for carbadox and up to 90 % for olaquindox was observed when using different extraction solvents and techniques as well as different chromatographic conditions. Reduction of matrix effects was achieved by SPE clean-up and dilution of sample extracts. Nevertheless, matrix effect profiles determined by postcolumn infusion revealed, that reduction of signal suppression at a respective retention time cannot guarantee improvement of the methods performance. If high variability of matrix effects is present along the chromatographic run, accuracy might decrease despite reduced signal suppression. Besides method parameters, different feedingstuffs were investigated and showed similar matrix effects.  相似文献   

16.
It would be preferable for pesticide residues substituted by hydrolyzable functionality to be analyzed after cooking because their structures are apt to degrade during boiling and/or heating. A liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for the quantitative determination of 44 pesticide residues with hydrolyzable functional group in five typical vegetable widely consumed in Republic of Korea is described. The sample clean‐up was carried out according to the method of Food Code No. 83 established by the Korea Food and Drug Administration (KFDA). Zorbox XDB‐C18 column was selected for the analysis because of the best peak separation. The LC mobile phase consisted of water and 5 mm methanolic ammonium formate, which resulted in a peak shape with good symmetry at each run. Tandem mass spectroscopic (MS/MS) experiments were performed in ESI positive mode and the multiple reaction monitoring modes. A conventional matrix effect was modified to more comprehensive form 100γij (%). A high matrix effect (相似文献   

17.
An improved, precise and reliable ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method has been developed for the quantification of trimetazidine, using trimetazidine‐d8 as the internal standard (IS). Interference owing to plasma phospholipids during sample preparation was overcome using a hybrid solid‐phase extraction–phospholipid ultra cartridge. The mean extraction recovery of trimetazidine (98.66%) and trimetazidine‐d8 (97.63%) from spiked plasma was consistent and reproducible. Chromatographic analysis was performed on a UPLC Ethylene Bridged Hybrid (BEH) C18 (50 × 2.1 mm, 1.7 μm) column with isocratic elution using acetonitrile–5 mm ammonium formate, pH 3.5 (40:60, v/v) as the mobile phase. The parent → product ion transitions for trimetazidine (m/z 267.1 → 181.1) and trimetazidine‐d8 (m/z 275.2 → 181.1) were monitored on a triple quadrupole mass spectrometer with electrospray ionization functioning in the positive multiple reaction monitoring mode. The linearity of the method was established in the concentration range of 0.05–100 ng/mL for trimetazidine. The intra‐batch and inter‐batch accuracy and precision (CV) were 97.3–103.1 and 1.7–5.3%, respectively. Qualitative and quantitative assessment of matrix effect showed no interference of endogenous/exogenous components. The developed method was used to measure plasma trimetazidine concentration for a bioequivalence study with 12 healthy subjects.  相似文献   

18.
Due to its high efficiency, selectivity, and sensitivity, CE-ESI/MS has evolved as an efficient technique for the drugs and metabolites analysis in biological matrices. However, a sample preparation is mandatory prior to CE-ESI/MS analysis. To achieve fast and simplified sample preparation of plasma samples, protein precipitation (PP) and liquid-liquid extraction (LLE) were used with two injection techniques: hydrodynamic (HD) and electrokinetic (EK) injection. CE-ESI/MS analyses of pharmaceutical compounds and amphetamine derivatives were developed. Detection limits of 1 ppm were reached with PP and HD injection whereas 1 ppb was detected when samples were prepared with LLE and injected by EK. Same experiments were performed for stereoselective determinations in partial-filling mode and detection limits achieved were equivalent to conventional analysis (0.5 ppb per enantiomer). When complex matrices are analyzed, MS signal suppression or enhancement effects are generally not reproducible and could compromise results with ESI. Therefore, matrix effect was investigated in CE-ESI/MS with a commercially available coaxial sheath-liquid ESI interface used as postcapillary infusion system to determine MS signal alterations. Matrix effects were differentially evidenced according to the selected sample preparation. With PP, signal suppression was observed out of the analyses migration window, while for LLE no relevant matrix effect occurred in all experiments.  相似文献   

19.
Liquid chromatography in conjunction with tandem mass spectrometry was used to directly quantify of 47 pesticide residues from cooked wheat flour and polished rice, which are the most widely consumed cereals in the Republic of Korea. The sample clean‐up was carried out according to the method established by the Korea Food and Drug Administration. The mobile phase for liquid chromatograpy separation consisted of water and 5 mm methanolic ammonium formate. Tandem mass spectroscopy experiments were performed in electrospray ionization positive mode and the multiple reaction monitoring mode. The matrix effects estimated for the 47 pesticides had a mean value of 99% and ranged from 45 to 147%. High recoveries (70–140%) and relative standard deviations (≤20%) were achieved for most of the pesticides tested. The method used in this study allowed for rapid quantification and identification of low levels of pesticides in cooked wheat flour and polished rice samples. Of the screened pesticide residues, only tricyclazole and fenobucarb were found in polished rice samples. However, no samples contained residues above the MRL established by the Korea Food and Drug Administration. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
Turbulent flow chromatography (TFC) is presented as a means to reduce ion suppression in simultaneous multianalyte mass spectrometric bioassays. In this study, the effects of enzymes present in the sample on the signal response of five analytes were simultaneously investigated over a protein content range from 0 to 38 microg/mL by means of direct flow injection MS. As model enzymes, trypsin, thrombin, and chymotrypsin were selected. Without employment of TFC, both signal suppression and signal enhancement, depending on the nature of the analyte and the amount of matrix in the sample, were observed. Generally, these matrix effects were found to be intolerably large. The deviation from the mean signal response as a measure of deterioration was found to be between 14 and 112%. The addition of an excess of methanol as means of sample clean-up was investigated and found not to be sufficient. By employing TFC for online sample preparation, it was possible to reduce the matrix effecTs to a minimum for all model systems investigated. In case of trypsin the distortion could be lowered from 41.9 to 2.6%. Thus, TFC is considered to be a highly valuable tool for improving the sensitivity and reliability in the monitoring of enzymatic conversions by means of MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号