首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The development of a miniaturized ammonia sensor made using microsystem technology is described. Gas is sampled in a sampler comprising two opposite channels separated by a gas permeable, water repellent polypropylene membrane. Subsequently, the acid sample solution is pumped into a selector where an alkaline solution is added to ionize all sampled ambient acid gasses, resulting in an enhanced selectivity. In the selector, the ammonia can diffuse through a second membrane into a purified water stream where an electrolyte conductivity sensor quantifies the resulting ammonium concentration. The realized system is shown to be selective enough not to be influenced by normal ambient carbon dioxide concentrations. Experiments with a gas flow of 3 ml/min, containing ammonia concentrations ranging from 9.8 to 0.3 ppm in a nitrogen carrier flow, into a 15 μl/min sample solution flow and finally into a 5 μl/min purified water stream have been carried out and show that the system is sensitive to ammonia concentration below 1 ppm.  相似文献   

2.
This work details the fabrication and performance of a sensor for ammonia gas analysis which has been constructed via the inkjet-printed deposition of polyaniline nanoparticle films. The conducting films were assembled on interdigitated electrode arrays and characterised with respect to their layer thickness and thermal properties. The sensor was further combined with heater foils for operation at a range of temperatures. When operated in a conductimetric mode, the sensor was shown to exhibit temperature-dependent analytical performance to ammonia detection. At room temperature, the sensor responded rapidly to ammonia (t50 = 15 s). Sensor recovery time, response linearity and sensitivity were all significantly improved by operating the sensor at temperatures up to 80 °C. The sensor was found to have a stable logarithmic response to ammonia in the range of interest (1-100 ppm). The sensor was also insensitive to moisture in the range from 35 to 98% relative humidity. The response of the sensor to a range of common potential interferents was also studied.  相似文献   

3.
The development of a nanosized SrCO3-based sensor based on the generated chemiluminescence (CL) from catalytic oxidation of organic vapors was demonstrated. The luminescence characteristics and effect of different parameters, such as temperature and flow rate, were discussed with a prepared CL detection system. This sensor was evaluated for the measurement of gaseous ethanol as a model analyte. Under the optimized conditions, the linear range of CL intensity versus concentration of ethanol vapor is 6-3750 ppm (r=0.998, n=8), with the limit of detection of 2.1 ppm. This SrCO3 sensor shows high selectivity to ethanol. There is no response while the foreign substances, such as gasoline, ammonia and hydrogen, are passing through the sensor. The hydrocarbons can slightly interfere with the ethanol measurement. The sensor also exhibits good stability and durability during 100 h reaction with 2000 ppm ethanol. The interactions between ethanol molecules and SrCO3 involving CL emission were investigated by utilizing gas chromatography in this paper and the possible mechanism of CL from ethanol oxidation on SrCO3 was discussed.  相似文献   

4.
A modified glassy carbon electrode was prepared by depositing a composite of polymer and mediator on a glassy carbon electrode (GCE). The mediator, flavin adenine dinucleotide (FAD) and the polymer, poly(3,4-ethylenedioxythiophene) (PEDOT) were electrochemically deposited as a composite on the GCE by applying cyclic voltammetry (CV). This modified electrode is hereafter designated as GCE/PEDOT/FAD. FAD was found to significantly enhance the growth of PEDOT. Electrochemical quartz crystal microbalance (EQCM) analysis was performed to study the mass changes in the electrode during the electrodeposition of PEDOT, with and without the addition of FAD. The optimal cycle number for preparing the modified electrode was determined to be 9, and the corresponding surface coverage of FAD (ΓFAD) was ca. 5.11 × 10−10 mol cm−2. The amperometric detection of iodate was performed in a 100 mM buffer solution (pH 1.5). The GCE/PEDOT/FAD showed a sensitivity of 0.78 μA μM−1 cm−2, a linear range of 4–140 μM, and a limit of detection of 0.16 μM for iodate. The interference effects of 250-fold Na+, Mg2+, Ca2+, Zn2+, Fe2+, Cl, NO3, I, SO42− and SO32−, with reference to the concentration of iodate were negligible. The long-term stability of GCE/PEDOT/FAD was also investigated. The GCE/PEDOT/FAD electrode retained 82% of its initial amperometric response to iodate after 7 days. The GCE/PEDOT/FAD was also applied to determine iodate in a commercial salt.  相似文献   

5.
A new ammonia gas microsensor was developed, based on the large resistance change of an ionic conductor (CuBr) film when exposed to low NH3 concentrations. The detection is based on specific interactions between ammonia molecules contained in the gas atmosphere and mobile copper ions in the copper(I) bromide layer. The sensor is operating at ambient temperature and allows highly sensitive and specific ammonia detection. The sensor works at ammonia concentrations between 1 and 500 ppm. There are no significant cross-effects to acetylene and carbon monoxide and only a weak cross-sensitivity to hydrogen sulfide gas (200 ppm). The selectivity was experimentally compared with commercial tin dioxide sensors (TGS 826). The sensor fabrication is a simple process, allowing low cost device production.  相似文献   

6.
A new piezoelectric quartz crystal (PQC) sorption detector was developed to monitor carbon monoxide (CO) at sub-ppm level in ambient air. Out of the 28 coating materials studied, the palladium(II) acetamide complex with a 1:10 mole ratio of Pd(II) to acetamide was found to be the best. The detection is based on a non-reversible gas/coating interaction with sensitivity depending on gas flowrate. For 5-15 min exposure at a flowrate of 50 ml/min, the working ranges were found to vary from 0.7 to 40 ppm (total exposure from 8 to 160 μg CO) and detection limits (S/N=2) from 0.7 to 2 ppm CO (total exposure to 8 μg CO). The repeatability at 10 ppm CO was 11.8% (R.S.D. for n=3). The sensor lifetime was found dependent on exposure up to 160 μg CO or not exceeding 1000 Hz accumulative shift of frequency to avoid saturation of active sites at the crystal surface. No interference to CO detection was found for H2, H2S, SO2, NO2, CO2, HCHO, gasoline and water vapors at concentrations much higher than ambient air. Compared to existing CO monitor, the PQC detector developed has advantages of adequate selectivity, high sensitivity, fast response and a much lower detection limit for detecting CO at sub-ppm levels. However, it is limited by the total exposure to a maximum of 160 μg CO that restricts its application to intermittent monitoring of low CO concentration. The present work has demonstrated the advantages of using strong non-reversible interaction to enhance PQC sensitivity, as the total exposure can be adjusted easily by a suitable control of the gas flowrate.  相似文献   

7.
Graphene-CdS (G-CdS) nanocomposites were successfully prepared by CdS nanocrystals (CdS NCs) formed in situ on the surface of graphene sheets, using graphene oxide (GO) sheets with rich negatively charged carboxylic acid groups as starting materials. Compared with pure CdS NCs, the presence of the graphene doped in G-CdS nanocomposites could facilitate the electrochemical redox process of CdS NCs; further, the as-prepared G-CdS nanocomposite can react with H2O2 to generate strong and stable electrochemiluminescent (ECL) emission, which not only enhances its ECL intensity by about 4.3-fold but also decreases its onset potential for about 320 mV. The as-prepared solid-state ECL H2O2 sensor shows acceptable linear response from 5 μM up to 1 mM with a detection limit of 1.7 μM (S/N = 3). The ECL H2O2 sensor exhibits excellent reproducibility and long-term stability. Such a property would promote the potential application of the graphene as enhanced materials in fabricating sensors for chemical and biochemical analysis.  相似文献   

8.
A sensor fabricated from the inkjet-printed deposition of polyaniline nanoparticles onto a screen-printed silver interdigitated electrode was developed for the detection of ammonia in simulated human breath samples. Impedance analysis showed that exposure to ammonia gas could be measured at 962 Hz at which changes in resistance dominate due to the deprotonation of the polymer film. Sensors required minimal calibration and demonstrated excellent intra-electrode baseline drift (≤1.67%). Gases typically present in breath did not interfere with the sensor. Temperature and humidity were shown to have characteristic impedimetric and temporal effects on the sensor that could be distinguished from the response to ammonia. While impedance responses to ammonia could be detected from a single simulated breath, quantification was improved after the cumulative measurement of multiple breaths. The measurement of ammonia after 16 simulated breaths was linear in the range of 40–2175 ppbv (27–1514 μg m−3) (r2 = 0.9963) with a theoretical limit of detection of 6.2 ppbv (4.1 μg m−3) (SN−1 = 3).  相似文献   

9.
Huili Zhang 《Talanta》2010,82(2):733-982
This work proposed a gas sensor for the determination of tert-butyl mercaptan, one of the highly toxic volatile sulfur compounds, which was based on cataluminescence emission during its catalytic oxidation on the surface of nanosized V2O5. The cataluminescence characteristics and the optimum conditions, including the morphology of sensing material, the wavelength of cataluminescence emission, the oxygen flow rate and working temperature were investigated in detail. Under the optimized conditions, the calibration curve of the relative cataluminescence intensity versus the concentration of tert-butyl mercaptan vapor was made, with the linear range of 5.6-196 μg mL−1 and the detection limit of 0.5 μg mL−1 (S/N = 3). The relative standard deviation (R.S.D.) (n = 5) of relative cataluminescence intensity for 84 μg mL−1 tert-butyl mercaptan was 3.6%. There is no or weak response to some common substances, such as formic acid, alcohol (methanol, ethanol, propanol, isopropanol, n-butanol, isoamyl alcohol), o-dichlorobenzene, acetonitrile, ethyl acetate, aldehyde (formaldehyde, acetaldehyde and propanal), 1,2-dichloroethane and ammonia. Furthermore, the proposed sensor was successfully used for determining tert-butyl mercaptan in four artificial samples, with a good recovery. The results demonstrated that the proposed gas sensor had a promising capability for the tert-butyl mercaptan in routine monitoring.  相似文献   

10.
Dacres H  Narayanaswamy R 《Talanta》2006,69(3):631-636
A highly sensitive optical humidity probe based on reflectance measurements has been developed using Nafion®-crystal violet (CV) films. This sensor can be used to calibrate relative humidity (RH) in the range 0-0.25% with a detection limit (blank signal + 3σb, where σb = the standard deviation (S.D.) of the blank signal) of 0.018% RH (∼4.37 ppm) and exhibited low hysteresis. The sensor films were fully reversible in dry nitrogen and reversal times were shown to be dependent on exposure time and % RH. The response to 1% RH was highly reproducible (S.D. = 1.67%, number of samples (n) = 5). Hydrogen chloride gas did not interfere with the response of the sensor to RH but did reduce sensor reversal times. This sensor displayed sufficient sensitivity that it could be used to detect ppm levels of moisture in process gases such as nitrogen and HCl.  相似文献   

11.
Design and fabrication of an ammonia sensor operating at room temperature based on pigment-sensitized TiO2 films was described. TiO2 was prepared by sol–gel method and deposited on glass slides containing gold electrodes. Then, the film immersed in a 2.5 × 10−4 M ethanol solution of cyanidin to absorb the pigment. The hybrid organic–inorganic formed film here can detect ammonia reversibly at room temperature. The relative change resistance of the films at a potential difference of 1.5 V is determined when the films are exposed to atmospheres containing ammonia vapors with concentrations over the range 10–50 ppm. The relative change resistance, S, of the films increased almost linearly with increasing concentrations of ammonia (r = 0.92). The response time to increasing concentrations of the ammonia is about 180–220 s, and the corresponding values for decreasing concentrations 240–270 s. At low humidity, ammonia could be ionized by the cyanidin on the TiO2 film and thereby decrease in the proton concentration at the surface. Consequently, more positively charged holes at the surface of the TiO2 have to be extracted to neutralize the adsorbed cyanidin and water film. The resistance response to ammonia of the sensors was nearly independent on temperature from 10 to 50 °C. These results are not actually as good as those reported in the literature, but this preliminary work proposes simpler and cheaper processes to realize NH3 sensor for room temperature applications.  相似文献   

12.
A chemiluminescence one-shot sensor for hydrogen peroxide is described. It is prepared by immobilization of cobalt chloride and sodium lauryl sulphate in hydroxyethyl cellulose matrix cast on a microscope cover glass. Luminol, sodium phosphate and the sample are mixed before use and applied on the membrane by a micropipette. The calibration graph is linear in the range 20-1600 μg/L, and the detection limit of the method (3σ) is 9 μg/L. A relative standard deviation of 4.5% was obtained for 100 μg/L H2O2 (n = 11). The sensor has been applied successfully to the determination of hydrogen peroxide in rainwater.  相似文献   

13.
An infrared (IR) chemical sensor based on immobilization of an acidified tris(2-aminoethyl)amine (ATAA) for the detection of tyrosine in urine is described. The sensing phase (i.e., coating) was saturated with nickel ions so that it would interact with tyrosine molecules in aqueous solution through the formation of stable ATAA-Ni2+-tyrosine complexes. Investigation of the signals of nine amino acids shows that only the three containing phenyl groups could be detected by this sensor system. A unique spectral feature located at 1515 cm−1 allowed tyrosine to be discriminated from the other two amino acids. To examine the performance of the ATAA sensing phase in the quantitative analysis of tyrosine, the effects of several factors were examined. pH affected the ability of tyrosine to form complexes; the optimal signal occurred at ca. pH 8. The concentration of ammonia buffer also affected the analytical signals through a competition effect; lower concentrations of ammonia buffer provided higher intensity signals. It was found that nickel ions are the most useful for detection of tyrosine. Although the concentration of nickel ions had less influence on the analytical signal than did the concentration of the ammonia buffer, the signal intensity was optimal when the nickel ions and the target molecule had similar concentrations. The detected time profiles indicated that the ATAA sensor phase functioned via a surface adsorption mechanism. The linear range of signal intensities was up to 600 μM with a detection limit of 30 μM.  相似文献   

14.
Gha-Young Kim 《Talanta》2007,71(1):129-135
A poly(vinyl alcohol) film cross-linked with glutaraldehyde (PVA-GA) was introduced to the surface of a tyrosinase-based carbon paste electrode. The coated PVA-GA film was beneficial in terms of increasing the stability and reproducibility of the enzyme electrode. The electrode showed a sensitive current response to the reduction of the o-quinone, which was the oxidation product of phenol, by the tyrosinase, in the presence of oxygen. The effects of the PVA and PVA-GA coating, the pH, and the GA:PVA ratio on the current response were investigated. The sensitivity of the PVA-GA-Tyr electrode was 130.56 μA/mM (1.8 μA/μM cm2) and the linear range of phenol was 0.5-100 μM. At a higher concentration of phenol (>100 μM), the current response showed the Michaelis-Menten behavior. Using the PVA-GA-Tyr electrode, a two-electrode system was tested as a prototype sensor for portable applications.  相似文献   

15.
Trichosporon jirovecii yeast cells are used for the first time as a source of l-cysteine desulfhydrase enzyme (EC 4.4.1.1) and incorporated in a biosensor for determining l-cysteine. The cells are grown under cadmium stress conditions to increase the expression level of the enzyme. The intact cells are immobilized on the membrane of a solid-state Ag2S electrode to provide a simple l-cysteine responsive biosensor. Upon immersion of the sensor in l-cysteine containing solutions, l-cysteine undergoes enzymatic hydrolysis into pyruvate, ammonia and sulfide ion. The rate of sulfide ion formation is potentiometrically measured as a function of l-cysteine concentration. Under optimized conditions (phosphate buffer pH 7, temperature 37 ± 1 °C and actual weight of immobilized yeast cells 100 mg), a linear relationship between l-cysteine concentration and the initial rate of sulfide liberation (dE/dt) is obtained. The sensor response covers the concentration range of 0.2-150 mg L−1 (1.7-1250 μmol L−1) l-cysteine. Validation of the assay method according to the quality control/quality assurance standards (precision, accuracy, between-day variability, within-day reproducibility, range of measurements and lower limit of detection) reveals remarkable performance characteristics of the proposed biosensor. The sensor is satisfactorily utilized for determination of l-cysteine in some pharmaceutical formulations. The lower limit of detection is ∼1 μmol L−1 and the accuracy and precision of the method are 97.5% and ±1.1%, respectively. Structurally similar sulfur containing compounds such as glutathione, cystine, methionine, and d-cysteine do no interfere.  相似文献   

16.
Lan Luo  Yi Lv 《Analytica chimica acta》2009,635(2):183-8983
A novel and sensitive gas sensor was proposed for the determination of carbon tetrachloride based on its cataluminescence (CTL) by oxidation in the air on the surface of nanosized ZnS. The luminescence characteristics and the optimal conditions were investigated in detail. Under the optimized conditions, the linear range of the CTL intensity versus the concentration of carbon tetrachloride was 0.4-114 μg mL−1, with a correlation coefficient (R) of 0.9986 and a limit of detection (S/N = 3) of 0.2 μg mL−1. The relative standard deviation (R.S.D.) for 5.9 μg mL−1 carbon tetrachloride was 2.9% (n = 5). There was no or weak response to common foreign substances including methanol, ethanol, benzene, acetone, formaldehyde, acetaldehyde, dichloromethane, xylene, ammonia and trichloromethane. There was no significant change of the catalytic activity of the sensor for 40 h over 4 days, with a R.S.D. of less than 5% by collecting the CTL intensity once an hour. The proposed method was simple and sensitive, with a potential of detecting carbon tetrachloride in environment and industry grounds. The possible mechanism was also discussed briefly.  相似文献   

17.
Chia-Yu Lin  Yi-Hsuan Lai 《Talanta》2010,82(5):1905-1911
In the present work, the oxidative electrochemistry of nitrite on the poly(3,4-ethylenedioxythiophene)/iron phthalocyanine/multi-wall carbon nanotubes-(PEDOT/FePc/MWCNT) modified screen-printed carbon electrodes (SPCE) has been investigated. The parameters, such as overpotential, current density and rate constant at PEDOT/FePc/MWCNT-modified SPCE, were compared with an un-modified, FePc-, and FePc/MWCNT-modified SPCE for electro-oxidation of nitrite. As compared with the un-modified SPCE, an increase in the anodic peak current density (Jpa) (∼100%) along with a decrease in the anodic peak potential (Epa) of ∼150 mV for electro-oxidation of nitrite at the FePc-modified SPCE was observed. When an under-layer of MWCNT was introduced onto FePc-modified SPCE, denoted as FePc/MWCNT-modified SPCE, and the number of FePc/MWCNT bilayer was optimized, the heterogeneous electron transfer rate constant (k) at FePc/MWCNT-modified SPCE was enhanced about 7.8 times as compared with that at FePc-modified SPCE. Moreover, as a layer of PEDOT film was electrodeposited onto the FePc/MWCNT-modified SPCE, denoted as PEDOT/FePc/MWCNT-modified SPCE, a significant increase in current response along with a remarkable decrease in Epa were noticed. This can be attributed to the pre-concentration effect induced by the electrostatic interaction between the negatively charged nitrite and oxidized PEDOT film. On the whole, the PEDOT/FePc/MWCNT-modified SPCE greatly reduces the overpotential of ∼330 mV along with 3.5 times enhanced the peak current density for the electro-oxidation of nitrite as compared with un-modified SPCE. The sensitivity and limit of detection (S/N = 3) for the PEDOT/FePc/MWCNT-modified SPCE were found to be as 638 mA cm−2 M−1 and 71 nM, respectively. Notably, PEDOT/FePc/MWCNT-modified SPCE has a lower sensing potential than compared to several other modified electrodes. The developed sensor was also applied for the determination of nitrite in tap water sample.  相似文献   

18.
A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32 μmol of HCl and 26.4 μmol of H3BO3in a final 20 ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK1 = 2.18, pK2 = 7.20 and pK3 = 12.32) as well as for a very weak acid of uncertain pK values H3BO3 (pK1 = 9.20, pK2 = 12.7 and pK3 = 13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.  相似文献   

19.
Zhouping Wang  Jun Li  Jinghong Li 《Talanta》2009,77(3):1050-319
It was found that the mixing of CdTe semiconductor nanocrystals (NCs) with luminol in the presence of KMnO4 can induce a great sensitized effect on chemiluminescence (CL) emission. When the concentration of luminol, KMnO4 and NaOH were fixed at 1 μM, 1 μM and 0.05 M, respectively, the most excellent performance can be obtained for the CdTe NCs sensitized CL. By means of CL and photoluminescence spectra, we suppose the enhanced CL signals resulted from the accelerated luminol CL induced by the oxidized species of CdTe NCs. Based on the finding, using thioglycolic acid-capped CdTe NCs as label and immunoglobulin G (IgG) as a model analyte, a CL immunoassay protocol for IgG content detection was developed. The strong inhibition effect of phenol compounds on luminol-KMnO4-CdTe NCs CL system was also observed. All these findings demonstrated the possibility of semiconductor nanocrystals induced chemiluminescence to be utilized for more practical applications.  相似文献   

20.
A novel cataluminescence (CTL) sensor using nanosized MgO as the sensing material for determination of the trace of vinyl acetate in air was proposed in the present study. Eight catalysts were examined and the results showed that the CTL intensity on MgO nanoparticles was the strongest. Under the optimized conditions, the linear range of the CTL intensity versus the concentration of vinyl acetate vapor was 2-2000 ppm with a detection limit of 1.0 ppm (3σ) and a relative standard deviation (R.S.D.) of 1.18% for five times determination of 1000 ppm vinyl acetate. There were no CTL emissions when foreign substances, including ammonia, benzene, acetic acid, formaldehyde and ethyl acetate, passed through the sensor. CTL emissions were detected for methanol, ethanol and acetaldehyde at levels around 5.5%, 10.1% and 13.4% compared with the responsed vinyl acetate. The sensor had a long lifetime more than 100 h.  相似文献   