首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
A novel automated off-line preconcentration system for trace metals (Al, Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in seawater was developed by improving a commercially available solid-phase extraction system SPE-100 (Hiranuma Sangyo). The utilized chelating resin was NOBIAS Chelate-PA1 (Hitachi High-Technologies) with ethylenediaminetriacetic acid and iminodiacetic acid functional groups. Parts of the 8-way valve made of alumina and zirconia in the original SPE-100 system were replaced with parts made of polychlorotrifluoroethylene in order to reduce contamination of trace metals. The eluent pass was altered for the back flush elution of trace metals. We optimized the cleaning procedures for the chelating resin column and flow lines of the preconcentration system, and developed a preconcentration procedure, which required less labor and led to a superior performance compared to manual preconcentration (Sohrin et al. [5]). The nine trace metals were simultaneously and quantitatively preconcentrated from ∼120 g of seawater, eluted with ∼15 g of 1 M HNO3, and determined by HR-ICP-MS using the calibration curve method. The single-step preconcentration removed more than 99.998% of Na, K, Mg, Ca, and Sr from seawater. The procedural blanks and detection limits were lower than the lowest concentrations in seawater for Mn, Ni, Cu, and Pb, while they were as low as the lowest concentrations in seawater for Al, Fe, Co, Zn, and Cd. The accuracy and precision of this method were confirmed by the analysis of reference seawater samples (CASS-5, NASS-5, GEOTRACES GS, and GD) and seawater samples for vertical distribution in the western North Pacific Ocean.  相似文献   

2.
The main difficulties of trace metals analysis in estuarine and seawater stem from their very low concentration (mug/l to sub-mug/l), and, by contrast, the high salt content (up to 38 g/l in the Mediterranean Sea). ICP-MS allows multi-elemental analysis and offers great sensitivity, but may be strongly affected by matrix effects induced by high salt contents (> 1 g/l). To perform trace metals analysis both in riverine, estuarine and seawater, we have developed a hyphenated method: ion chelation chromatography coupled on-line with ICP-MS. Iminodiacetate resin, Metpac CC-1 (Dionex), was used to concentrate most of the trace metals, and to separate them from alkaline and alkaline-earth metals. Behaviour of 17 elements (Pb, Cu, Cd, Ni, U, Cr, Mn, Al, Co, Ga, In, Zn, V, Tl, Bi, Ag and Sn) towards the resin was qualitatively investigated. A method validation, partly derived from AFNOR standard XPT 90-210, was carried out on 12 elements (Pb, Cu, Cd, Ni, U, Cr, Mn, Al, Co, Ga, Bi and In). Replicate measurements of multi-elemental standard solutions were used to check linearity, and to determine repeatability and detection limits. Method accuracy was then assessed by analysing two certified materials: a synthetic freshwater (SRM 1643d), and a natural filtered coastal seawater (NRCC CASS-3). An application assay of natural samples from the Rh?ne river (France) was eventually carried out, and the analytical results were found to be consistent with previous works.  相似文献   

3.
D. Point  G. Bareille  C. Belin 《Talanta》2007,72(3):1207-1216
An integrated approach for the accurate determination of total, labile and organically bound dissolved trace metal concentration in the field is presented. Two independent automated platforms consisting of an ultraviolet (UV) on-line unit and a chelation/preconcentration/matrix elimination module were specifically developed to process samples on-site to avoid sample storage prior to inductively coupled plasma mass spectrometry (ICP-MS) analysis. The speciation scheme allowed simultaneous discrimination between labile and organic stable dissolved species of seven trace elements including Cd, Cu, Mn, Ni, Pb, U and Zn, using only 5 ml of sample with detection limits ranging between 0.6 ng l−1 for Cd and 33 ng l−1 for Ni. The influence of UV photolysis on organic matter and its associated metal complexes was investigated by fluorescence spectroscopy and validated against natural samples spiked with humic substances standards. The chelation/preconcentration/matrix elimination procedure was validated against an artificial seawater spiked sample and two certified reference materials (SLRS-4 and CASS-4) to ensure homogenous performance across freshwater, estuarine and seawater samples. The speciation scheme was applied to two natural freshwater and seawater samples collected in the Adour Estuary (Southwestern, France) and processed in the field. The results indicated that the organic complexation levels were high and unchanged for Cu in both samples, whereas different signatures were observed for Cd, Mn, Ni, Pb, U and Zn, suggesting organic ligands of different origin and/or their transformation/alteration along estuarine water mixing.  相似文献   

4.
A bulk liquid membrane system has been developed and applied to the simultaneous separation and preconcentration of up to seven heavy metals (copper, zinc, lead, cadmium, aluminium, manganese, and nickel) in seawater. Copper was selected to optimize transport conditions and then, under these conditions, the simultaneous extraction of other heavy metals was studied. The system achieved preconcentration yields ranging between 44.11% (Cd) and 77.77% (Cu) after nine hours of operation, the effectiveness of metal transport being Cu > Zn > Pb > Mn > Ni > Al > Cd. The system was applied to the preconcentration of four real seawater samples before their quantification by inductively coupled plasma–mass spectrometry (ICP–MS). Compared with the analytical procedures commonly used for trace metal determination in oceanography, the results obtained demonstrated that the new system may be used as a very clean (sample contamination-free), simple, and one-step alternative for semiquantitative, and even quantitative, simultaneous determination of heavy metals in seawater.  相似文献   

5.
A flow-injection system is developed for Cu, Mn and Zn partitioning in seawater by flame atomic absorption spectrometry. The first approach is where the trace metal species are fractionated in situ, but analysis is performed by using a flow injection manifold in the laboratory. This operational mode is used for the determination of the dissolved labile metallic fraction and is based on the elution of this fraction from a minicolumn packed with a chelating resin containing iminodiacetic acid groups (Serdolit Chelite Che) loaded in situ with the sample. The second is used for the determination of total dissolved concentrations of trace metals. This last mode is based on the retention/preconcentration of total dissolved metals on the chelating resin after on-line sonolysis of seawater samples acidified with diluted nitric acid to breakdown the metal-organic matter complexes. The figures of merit for Cu, Mn and Zn determinations in both fractions are given and the obtained values are discussed. The fractionation scheme is applied to the analysis of coastal seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Mn and Zn are mainly in the labile fraction, while Cu was mainly present in the organic fraction.  相似文献   

6.
The study of Fe, Zn and Cd stable isotopes (δ56Fe, δ66Zn and δ114Cd) in seawater is a new field, which promises to elucidate the marine cycling of these bioactive trace metals. However, the analytical challenges posed by the low concentration of these metals in seawater has meant that previous studies have typically required large sample volumes, highly limiting data collection in the oceans. Here, we present the first simultaneous method for the determination of these three isotope systems in seawater, using Nobias PA-1 chelating resin to extract metals from seawater, purification by anion exchange chromatography, and analysis by double spike MC-ICPMS. This method is designed for use on only a single litre of seawater and has blanks of 0.3, 0.06 and <0.03 ng for Fe, Zn and Cd respectively, representing a 1–20 fold reduction in sample size and a 4–130 decrease in blank compared to previously reported methods. The procedure yields data with high precision for all three elements (typically 0.02–0.2‰; 1σ internal precision), allowing us to distinguish natural variability in the oceans, which spans 1–3‰ for all three isotope systems. Simultaneous extraction and purification of three metals makes this method ideal for high-resolution, large-scale endeavours such as the GEOTRACES program.  相似文献   

7.
Copper is an essential trace metal that shows a vertical recycled-scavenged profile in the ocean. To help elucidate the biogeochemical cycling of Cu in the present and past oceans, it is important to determine the distribution of Cu isotopes in seawater. However, precise isotopic analysis of Cu has been impaired by the low concentrations of Cu as well as co-existing elements that interfere with measurements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The objective of this study is to develop a simple Cu pre-concentration method using Nobias-chelate PA1 resin (Hitachi High Technologies). This extraction followed by anion exchange, allows precise analysis of the Cu isotopic composition in seawater. Using this method, Cu was quantitatively concentrated from seawater and >99.9999% of the alkali and alkaline earth metals were removed. The technique has a low procedural blank of 0.70 ng for Cu for a 2 L sample and the precision of the Cu isotopic analysis was ±0.07‰ (±2SD, n = 6). We applied this method to seawater reference materials (i.e., CASS-5 and NASS-6) and seawater samples obtained from the northwestern Pacific Ocean. The range of dissolved δ65Cu was 0.40–0.68‰.  相似文献   

8.
Dwinna Rahmi 《Talanta》2007,72(2):600-606
The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200-400 mesh), with which trace metals in 50 mL of original seawater sample were concentrated into 0.50 mL of 2 M nitric acid, and then 100-fold preconcentration of trace metals was achieved. Then, 0.50 mL analysis solution was subjected to the multielement determination by ICP-MS equipped with a MicroMist nebulizer for micro-sampling introduction. The preconcentration and elution parameters such as the sample-loading flow rate, the amount of 1 M ammonium acetate for elimination of matrix elements, and the amount of 2 M nitric acid for eluting trace metals were optimized to obtain good recoveries and analytical detection limits for trace metals. The analytical results for V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U in three kinds of seawater certified reference materials (CRMs; CASS-3, NASS-4, and NASS-5) agreed well with their certified values. The observed values of rare earth elements (REEs) in the above seawater CRMs were also consistent with the reference values. Therefore, the compiled reference values for the concentrations of REEs in CASS-3, NASS-4, and NASS-5 were proposed based on the observed values and reference data for REEs in these CRMs.  相似文献   

9.
In order to estimate metal distribution patterns in biomolecules of different sizes and their possible relationship with environmental heavy metal contamination, multi-elemental distributions in different fractions of the cytosols of mussels were studied. To do so, samples were collected from natural populations of two coastal regions in Spain: a wild (uncontaminated) coast and an industrialised (contaminated) area in Asturias. Moreover, some commercial mussels from the Galicia coast were also investigated for comparison. Aliquots of the mussel cytosol extracts from each sample were applied to a calibrated Sephadex G-75 column (100 x 1 cm) and forty 3 ml fractions were obtained. After suitable dilution, 18 trace metals were determined by double focusing inductively coupled plasma mass spectrometry (DF-ICP-MS). The use of DF-ICP-MS detection allowed the resolution of several spectral interferences that cannot be resolved by quadrupole ICP-MS. Accurate results for ultratrace elements at basal levels are possible even after sample dilution to prevent matrix effects. After biomolecule-metal association pattern has been established, quantitative analysis of mussel cytosols from the three coastal areas was carried out, using external aqueous calibration plus standard additions to correct for possible matrix effects. Results showed that total metal contents increased following the expected order: wild coast < Galicia coast < industrial area coast. Speciation of Cu, Zn, Ca, U, Ni, Mo, Mn, Cr, V, Cd, Al and Sb showed a similar distribution pattern among cytosolic ligands for all the studied samples. Conversely, Fe, Pb, Sn, Co, Hg and Ag were found to exhibit different speciation patterns when samples from industrialised (contaminated) and non-industrialised areas were compared.  相似文献   

10.
An automated on-line sample-preparation method using a computer-controlled pretreatment system (Auto-Pret AES system) coupled with ICP-AES was developed. In this work, an iminodiacetate chelating resin, packed in a mini-column and installed in the system was employed for the collection/concentration of 13 trace metals, including such toxic metals as Be, Cd, Cr, Cu and Pb. The limits of detection of the proposed method for trace metals were in the range of 0.001 (Be) -0.18 (Pb) ng mL-1. The enrichment factors for metal ions were about 19 times, when 5 mL of samples were used. The sample throughput was 11 h-1. The accuracy and the precision of the method were evaluated using river-water reference materials, SLRS-4 from NRCC, JSAC 0301-1 and JSAC 0302 from the Japan Society for Analytical Chemistry. The proposed method can be favorably applied to the collection/concentration of trace metals in natural water samples.  相似文献   

11.
Here, we present the first simultaneous preconcentration and determination of ultratrace (pmol kg−1 level) Zr, Hf, Nb, Ta and W in seawater, both in the form of dissolved and acid-dissolvable species. 8-Hydroxyquinoline (8HQ) bonded covalently to a vinyl polymer resin, TSK-8HQ, was used in a chelating adsorbent column to concentrate the metals. The greatest advantage of this resin is its endurance to 5 M HF, since this is an effective eluent for all five metals. The analytes were successfully concentrated from 250 mL seawater with a 50-fold concentration factor through the column extraction and evaporation. The detection limit was 0.009-0.15 pmol kg−1. The procedure blank determined using ultra pure water as a sample was 0.005-0.37 pmol kg−1. The five metals were quantitatively recovered from seawater with good precision (2-4%). The effect of sample pH, sample flow rate, eluent composition and sample pretreatment were carefully studied. This method was applied to seawater.  相似文献   

12.
A simple and accurate low-blank method has been developed for the analysis of total dissolved copper, cadmium, lead, and iron in a small volume (1.3-1.5 mL per element) of seawater. Pre-concentration and salt-separation of a stable isotope spiked sample are achieved by single batch extraction onto nitrilotriacetate (NTA)-type Superflow(?) chelating resin beads (100-2400 beads depending on the element). Metals are released into 0.1-0.5 M HNO(3), and trace metal isotope ratios are determined by ICPMS. The benefit of this method compared to our previous Mg(OH)(2) coprecipitation method is that the final matrix is very dilute so cone-clogging and matrix sensitivity suppression are minimal, while still retaining the high accuracy of the isotope dilution technique. Recovery efficiencies are sensitive to sample pH, number of resin beads added, and the length of time allowed for sample-resin binding and elution; these factors are optimized for each element to yield the highest recovery. The method has a low procedural blank and high sensitivity sufficient for the analysis of pM-nM open-ocean trace metal concentrations. Application of this method to samples from the Bermuda Atlantic Time-Series Study station provides oceanographically consistent Cu, Cd, Pb, and Fe profiles that are in good agreement with other reliable data for this site. In addition, the method can potentially be modified for the simultaneous analysis of multiple elements, which will be beneficial for the analysis of large number of samples.  相似文献   

13.
J. Galceran  C. Huidobro  G. Alberti 《Talanta》2007,71(4):1795-1803
Absence of Gradients and Nernstian Equilibrium Stripping (AGNES) is a recently suggested electroanalytical technique designed for the determination of the free concentration of heavy metals (such as Zn, Cd or Pb) which is here developed and applied to seawater samples. A key improvement for the implementation of AGNES with complex matrices is the development of a new blank, called the shifted blank (presented in this work for the first time), which can be applied to the same sample where the measurement is intended. The careful selection of the required parameters for the determination of the free Zn concentration (or activity) at the nanomolar level is described in detail. The methodology has been validated with a synthetic solution containing Zn and nitrilotriacetic acid (NTA) and then applied, as a first case, to two coastal seawater samples taken close to Barcelona and Tarragona (Catalonia, North-Eastern Spain) finding values in the range of 1-3 nM, representing around 25% of total Zn. This technique can, in the near future, be crucial in helping to elucidate the role of the free zinc(II) concentration in natural waters.  相似文献   

14.
We have developed a method for the quantification of 14 cosmochemically moderately volatile to highly volatile trace elements (Cu, Zn, Ga, Se, Rb, Ag, Cd, In, Sn, Sb, Te, Cs, Tl, and Bi) in chondritic meteorites by ICPMS. The method utilizes internal standardization via addition of Be, Rh, Re, and U and multiple single point matrix-matched external calibrations with Allende standard reference meteorite to provide drift corrected calibration within an ICPMS procedure. We have demonstrated our method's precision and accuracy by performing replicate dissolutions and analyses of 0.05-0.10 g samples of a homogenized sample of the CM2 Murchison meteorite and compared our results to literature values for this meteorite. Our procedure allows for a rapid and accurate determination of the cosmochemically important VTEs in chondritic meteorites providing the means for an even more comprehensive elemental analysis of a single sample of chondritic material.  相似文献   

15.
A rapid separation and preconcentration method was developed for the determination of trace metals Cu, Zn, Cd, and Pb in seawater using a minicolumn packed with thiol cotton fiber (TCF) coupled with inductively coupled plasma mass spectrometry (ICP-MS). Preconcentration parameters, such as seawater sample volume and flow rate and eluent hydrochloric acid concentration, volume and flow rate, were optimized. Under the optimized conditions, trace metals Cu, Zn, Cd, and Pb in seawater can be determined with no interference from saline matrices. When a sample volume of 1500 ml and a sample flow rate of 15 ml min(-1) were used, the preconcentration factor of 1500 and RSD value of <7% at ng ml(-1) were achieved. The accuracy of the recommended method was verified by the analysis of certified reference materials.  相似文献   

16.
Rosi Ketrin Katarina 《Talanta》2009,78(3):1043-990
On-line preconcentration and determination of transition and rare-earth metals in water samples was performed using a Multi-Auto-Pret system coupled with inductively coupled plasma-atomic emission spectrometry (ICP-AES). The Multi-Auto-Pret AES system proposed here consists of three Auto-Pret systems with mini-columns that can be used for the preconcentration of trace metals sequentially or simultaneously, and can reduce analysis time to one-third and running cost of argon gas and labor. A newly synthesized chelating resin, ethylenediamine-N,N,N′-triacetate-type chitosan (EDTriA-type chitosan), was employed in the Multi-Auto-Pret system for the collection of trace metals prior to their measurement by ICP-AES. The proposed resin showed very good adsorption ability for transition and rare-earth metal ions without any interference from alkali and alkaline-earth metal ions in an acidic media. For the best result, pH 5 was adopted for the collection of metal ions. Only 5 mL of samples could be used for the determination of transition metals, while 20 mL of samples was necessary for the determination of rare-earth metals. Metal ions adsorbed on the resin were eluted using 1.5 M nitric acid, and were measured by ICP-AES. The proposed method was evaluated by the analysis of SLRS-4 river water reference materials for trace metals. Good agreement with certified and reference values was obtained for most of the metals examined; it indicates that the proposed method using the newly synthesized resin could be favorably used for the determination of transition and rare-earth metals in water samples by ICP-AES.  相似文献   

17.
EDTA, a powerful chelating agent, is used extensively in soil sciences to determine the bioavailability of trace metals and their possible decontamination from polluted soils. Because of its non-selective nature, the co-dissolution of major elements also occurs, in addition to the extraction of trace metal ions.In this work, the reactivity of trace and major elements (Pb, Cu, Cd, Al, Fe, Ca and Mg) with different concentrations of EDTA was studied in eight soil samples (Burgundy, France). The limit between lack and excess of EDTA with respect to total metal extracted, determined after 24 h of reaction for different types of soil varied from 0.002 to 0.05 M, respectively.For calcareous samples the amount of Pb, Cu and Cd extracted by EDTA was reduced to 50% of that extracted in non-calcareous soils.From the kinetic point of view, the extraction behavior of major elements seemed to depend heavily on excess or lack of EDTA and the soil Ca content. For a lack of EDTA, different competitive behaviors were revealed for the major elements (Al, Ca, Fe and Mg) towards the reagent, depending on the soil matrix.According to these experimental results, the mass balance between the reagent and cations in any EDTA-soil media is strongly controlled by major metal extraction. When choosing the reagent concentration needed to extract the trace metals efficiently, all the extractable metal present in the concerned sample must be taken into account.  相似文献   

18.
This paper discusses the partitioning of metals (K, Na, Ca, Mg, Al, Cu, Fe, Pb and Zn) between the aqueous phase and the suspended insoluble material in fog samples collected in the Po Valley during two extensive fields campaigns. Metals represent on average 11% of the mass of suspended insoluble matter, while the main component is carbon (both organic carbon, OC = 35%, and black carbon, BC = 8%). The unaccounted suspended matter mass is very high, on average 46%, and is attributable to non metallic species, such as O and N and of Si. The principal metals in the insoluble suspended fraction are Fe and Al (2-5%), while the contributions of other metals (Na, Mg, Cu, Pb and Zn) are lower than 1%. Ca and K exhibited high blank values and could not be detected above blank detection limit threshold. The main components in the aqueous phase are NO3- (34%), WSOC (23%), SO4(2-) (18%) and NH4+ (19%), while trace metals and remaining cations and anions accounted for less than 1% of solute mass. The main dissolved trace metals in fog droplets are Zn, Al and Fe, while the main metallic cations are Na and Ca. Fe and Al are the only metals preferentially distributed in the suspended insoluble matter of fog droplets (partitioning ratio respectively 37% and 33%). All other metals are mostly dissolved in the aqueous phase (mean partitioning ratios of Mg, Pb, Zn, Cu and Na are 69%, 70%, 77%, 81% and 87%). These findings are in agreement with literature data on metal speciation in cloud and rain samples. The dependence of partitioning ratios on pH is investigated for the different metals, with only Al showing a clear partitioning ratio decrease with increasing pH. Conversely, the other metals show no dependence or a complex and highly variable behaviour. The partitioning ratio of iron (mean 37%) observed in the Po Valley fog samples is much higher than the water extractable iron in aerosol particles (typically 1-2 %): this fact can be explained by differences in the aerosol sources and composition among sites and by chemical processes in the aqueous phase, such as complexation and redox reactions involving organic ligands (oxalate, or other organic acids as humic-like organic matter) which may promote Fe solubility.  相似文献   

19.
A method has been developed for the determination of Al, Cd, Cr, Cu, Fe, Mg, Mn, Ni, Sb, Sn and Zn at trace levels in high purity di-boron trioxide using ETAAS. The boron trioxide matrix was eliminated as trimethyl borate ester in a multiplex vapor phase matrix extraction (MVPME) device using a mixture of glycerol and methanol. In this MVPME device, in situ reagent purification, sample digestion and simultaneous matrix elimination were achieved by a single step in closed condition, which in combined effect reduce the process blanks. The matrix extraction procedure allows determination of trace elemental impurities by electrothermal atomic absorption spectrometry (ETAAS) with fast furnace analysis (without an ashing step and modifier) and calibration against aqueous standards. The performance and accuracy of the vapor phase matrix elimination technique are compared to those of suprapur grade hydrofluoric acid solution in two ways; (i) matrix separation as BF3 over hot plate and (ii) in situ matrix elimination inside graphite furnaces. The method detection limits calculated from blank samples are in the range of 0.5 (Ni) and 2.9 (Al) ng g−1. Thus the MVPME-based sample preparation approach is well suited for the trace analysis of high purity di-boron trioxide used in microelectronics applications.  相似文献   

20.
Miró M  Estela JM  Cerdà V 《Talanta》2004,63(2):201-223
In the earlier parts of this series of reviews [1] and [2], the most relevant flowing stream techniques (namely, segmented flow analysis, continuous flow analysis, flow injection (FI) analysis, sequential injection (SI) analysis, multicommuted flow injection analysis and multisyringe flow injection analysis) applied to the determination of several core inorganic parameters for water quality assessment, such as nutrients and anionic species including nitrogen, sulfur and halogen compounds, were described.In the present paper, flow techniques are presented as powerful analytical tools for the environmental monitoring of metal ions (alkaline and alkaline-earth metals, and elemental and harmful transition metals) as well as to perform both multielemental and speciation analysis in water samples. The potentials of flow techniques for automated sample treatment involving on-line analyte separation and/or pre-concentration are also discussed in the body of the text, and demonstrated for each individual ion with a variety of strategies successfully applied to trace analysis. In this context, the coupling of flow methodologies with atomic spectrometric techniques such as flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS), inductively coupled plasma mass spectrometry (ICPMS) or hydride-generation (HG)/cold-vapor (CV) approaches, launching the so-called hyphenated techniques, is specially worth mentioning.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号