首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A non-enzymatic impedimetric glucose sensor was fabricated based on the adsorption of gold nanoparticles (GNPs) onto conductive polyaniline (PANI)-modified glassy carbon electrode (GCE). The modified electrode (GCE/PANI/GNPs) was characterized by using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). The determination of glucose concentration was based on the measurement of EIS with the mediation of electron transfer by ferricyanide ([Fe(CN)6]3?). The [Fe(CN)6]3? is reduced to ferrocyanide ([Fe(CN)6]4?), which in turn is oxidized at GCE/PANI/GNPs. An increase in the glucose concentration results in an increase in the diffusion current density of the [Fe(CN)6]4? oxidation, which corresponds to a decrease in the faradaic charge transfer resistance (R ct). A wide linear concentration range from 0.3 to 10 mM with a lower detection limit of 0.1 mM for glucose was obtained. The proposed sensor shows high sensitivity, good reproducibility, and stability. In addition, the sensor exhibits no interference from common interfering substances such as ascorbic acid, acetaminophen, and uric acid.  相似文献   

2.
1. Cupric ferrocyanide is oxidized by bromine water to cupric ferricyanide. 2. Cupric ferrocyanide is soluble in disodium tartrate in presence of a small quantity of sodium carbonate. 3. Cupric ferricyanide is reduced by sodium sulfite or by sulfurous acid to cupric ferrocyanide only. 4. Cupric ferrocyanide is reduced by sodium hyposulfite (Na2S2O4) to white cuprous ferrocyanide Cu4[Fe(CN)6].  相似文献   

3.
Fe(CN)4?6, Cu(CN)3?4, Co(CN)3?6, Fe(CN)3?6, Ni(CN)2?4 and Cr(CN)3?6 are determined by ion-interaction chromatography using a C18 column and methanol-tetrahydrofuran-10 mM phosphate buffer (pH 7.9) (25 + 1 + 74, v/v/v) containing 5 mM tetrabutylammonium hydroxide as mobile phase, with spectrophotometric detection at 214 nm. Detection limits are in the range 0.01–0.5 mg 1?1. In an alternative approach, an automated on-line sample preconcentration technique is used wherein a 2-ml volume of sample containing metallo-cyanides is loaded onto a C18 precolumn which has been equilibrated with the above mobile phase. The bound solutes are then eluted from the precolumn to a C18 analytical column where they are separated using the same mobile phase as employed to equilibrate the precolumn. Detection limits are in the rate 0.08–1.58 μg 1?1 and calibration graphs are linear up to 200 μg 1?1. The preconcentration step is shown to give quantitative recoveries for all species except Fe(CN)4?6 and (CN)3?4. The iron(II) complex does not bind quantitatively to the precolumn, and extensive studies with the copper complex suggested that low recoveries were due to dissociation and ligand-exchange reactions occurring during the chromatographic separation process. Negative interference effects were observed for Cl? and SO2?4 when present at a level of 250 mg 11?, and UV-absorbing anions such as Br?, SCN?, NO?2 and NO?3 caused positive interference when present at concentrations as low as 1 mg 1?1. The negative interferences could be reduced by diluting the sample and the positive interferences could be eliminated by incorporating an additional step in the preconcentration process, in which UV-absorbing anions bound to the precolumn after sample loading were eluted selectively using an eluent consisting of 10 mM NaCl in phosphate buffer (pH 6.7).  相似文献   

4.
Nickel ferrocyanide in presence of acids is oxidised by the oxygen of the air to nickel ferricyanide. Cobalt ferrocyanide is oxidised under the same conditions to a ultramarine blue substance with a slight grayish tinge. This substance is very similar to Prussian blue and to Turnbull's blue and could be called cobalt Prussian blue. This blue substance is also formed if mixtures of potassium ferrocyanide and potassium ferricyanide are precipitated with an excess of cobalt salt. This investigation led to the conclusion that the blue substance is probably not a mere mixture of cobalt ferrocyanide and cobalt ferricyanide. but the compound 6 Co2[Fe(CN)6]. Co3[Fe(CN)6]2. A new method of the determination of ferricyan is described. Moreover, it was proved that some statements of former investigators on the reactions of nickel and cobalt with iron-cyanogen compounds are erroneous, and some iron-cyanogen compounds of nickel and cobalt described in the literature do not exist at all.  相似文献   

5.
Yu L  Ye H  Zheng L  Chen L  Chu K  Liu X  Xu X  Chen G 《Electrophoresis》2011,32(2):218-222
A new method for separation and determination of amygdalin and its epimer (neoamygdalin) in the epimerization of amygdalin by MEEKC is proposed. For the chiral separation of amygdalin and neoamygdalin, a running buffer composed of 80 mM sodium cholate, 5.0% v/v butan‐1‐ol, 0.5% v/v heptane and 94.5% v/v 30 mM Na2B4O7 buffer (pH 9.00) is proposed. Under optimum conditions, the basic separation of amygdalin and neoamygdalin can be achieved within 7 min. The calibration curve for amygdalin showed excellent linearity in the concentration range of 20–1000 μg/mL with a detection limit of 5.0 μg/mL (S/N=3). The epimerization rate constant of amygdalin in basic microemulsion was first determined by monitoring the concentration changes of amygdalin, and the epimerization rate constant of amygdalin was found to be 2×10?3 min?1 at 25°C under the above optimum microemulsion conditions.  相似文献   

6.
In this study, a stability‐indicating reversed‐phase liquid chromatographic electrospray mass spectrometric method was developed and validated for the determination of process‐related impurities and forced degradants of Efavirenz in bulk drugs. Efavirenz was subjected to acid, alkaline hydrolysis, H2O2 oxidation, photolysis, and thermal stress. Significant degradation was observed during alkaline hydrolysis, and the degradants were isolated on a mass‐based purification system and characterized by high‐resolution mass spectrometry, positive electrospray ionization tandem mass spectrometry, and 1H and 13C NMR spectroscopy. Accurate mass measurement and NMR spectroscopy revealed the possible structure of process‐related impurities and degradant under stress conditions. The acceptable separation was accomplished on Waters bondapak C18 column (250 mm × 4.6 mm; 5 μm), using 5 mM ammonium acetate and acetonitrile as a mobile phase in a gradient elution mode at a flow rate of 1.0 mL/min. The eluents were monitored by diode array detector at 247 nm and quantitation limits were obtained in the range of 0.1–2.5 μg/mL for Efavirenz, degradants, and process‐related impurities. The liquid chromatography method was validated with respect to accuracy, precision, linearity, robustness, and limits of detection and quantification as per International Conference on Harmonization guidelines.  相似文献   

7.
Within this paper, a glassy carbon electrode modified with single‐walled carbon nanotubes (SWCNTs?GCE) was prepared, and employed for the determination of clorsulon (Clo), which is a frequently used veterinary drug against common liver fluke. The comprehensive topographical and electrochemical characterizations of bare GCE and SWCNTs?GCE were performed by atomic force microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry. Significantly enhanced electrochemical characteristics of SWCNTs?GCE toward a ferrocyanide/ferricyanide redox couple was observed when compared to bare GCE. Further, the prepared sensor was applied for the voltammetric determination of Clo, which was electrochemically investigated for the first time in this work. Voltammetric experiments were performed using square‐wave voltammetry with optimized parameters in phosphate buffer solution, pH 6.8, which was selected as the most suitable medium for the determination of Clo. The corresponding current at approx. +1.1 V increased linearly with Clo concentration within two linear dynamic ranges of 0.75–4.00 μmol L?1 (R2=0.9934) and 4.00–15.00 μmol L?1 (R2=0.9942) with a sensitivity for the first calibration range of 0.76 μA L μmol?1, a limit of detection of 0.19 μmol L?1, and a limit of quantification of 0.64 μmol L?1. The developed method was subsequently applied for quantitative analysis of Clo in milk samples with results proving high repeatability and recovery.  相似文献   

8.
Zuo Y  Wang C  Van T 《Talanta》2006,70(2):281-285
A simple, fast, sensitive and accurate reversed-phase ion-pair HPLC method for simultaneous determination of nitrite and nitrate in atmospheric liquids and lake waters has been developed. Separations were accomplished in less than 10 min using a reversed-phase C18 column (150 mm × 2.00 mm i.d., 5 μm particle size) with a mobile phase containing 83% 3.0 mM ion-interaction reagent tetrabutylammonium hydroxide (TBA-OH) and 2.0 mM sodium phosphate buffer at pH 3.9 and 17% acetonitrile (flow rate, 0.4 mL/min). UV light absorption responses at 205 nm were linear over a wide concentration range from 100 μg/mL to the detection limits of 10 μg/L for nitrite and 5 μg/L nitrate. Quantitation was carried out by the peak area method. The relative standard deviation for the analysis of nitrite and nitrate was less than 3.0%. This method was applied for the simultaneous determination of nitrite and nitrate in dew, rain, snow and lake water samples collected in southeast Massachusetts. Nitrate was found being present at 4.79-5.99 μg/mL in dew, 1.20-2.63 μg/mL in rain, 0.32-0.60 μg/mL in snow and 0.12-0.23 μg/mL in lake water. Nitrite was only a minor species in dew (0.62-0.83 μg/mL), rain (<0.005-0.14 μg/mL), snow (0.021-0.032 μg/mL) and lake water (0.12-0.16 μg/mL). High levels of nitrite and nitrate observed in dew water droplets may constitute an important source of hydroxyl radicals in the sunny early morning.  相似文献   

9.
《Analytical letters》2012,45(6):1125-1135
Abstract

A HPLC method has been developed to determine the concentrations of SAZ-VII-23 (3-benzoyl-7-isopropyl-3,7-diazabicyclo[3.3.1]nonane HClO4), a novel antiarrhythmic agent, in dog plasma and urine. Plasma treated with acetonitrile and alkalinized urine were extracted with chloroform- propanol (9:1). An aliquot was injected on to HPLC system using a C6 reversed-phase column and acetonitrile-methanol-37.5 mM phosphate buffer, pH 6.8 (28.5:28.5:43 v/v) containing 4.0 mM triethylamine as mobile phase. Detection wavelength was 255 nm. The linear range were 0.04–8 μg/ml, and the lower limit of quantitation was 0.04 μg/ml in plasma and urine, respectively. The method was applied to determine plasma and urine concentrations and preliminary pharmacokinetic profiles of SAZ-VII-23 in a dog.  相似文献   

10.
A cobalt oxide nanoparticles (Co3O4NPs) and multi walled carbon nanotubes (MWCNTs) modified carbon paste electrodes were used to study the electrochemical behavior of linagliptin and empagliflozin in Britton Robinson buffer solution of pH 8.0 using cyclic and square wave voltammetry. The above mentioned modified electrodes showed highly sensitive sensing and gave an excellent anodic response for both drugs. The peak current varied linearly over the concentration ranges: 3.98×10?5–1.53×10?3 mol L?1 (18.82–723.00 μg/mL) and 7.94×10?6–1.07×10?4 mol L?1 (3.65–48.25 μg/mL) with determination coefficients of 0.9999 and 0.9998 for linagliptin and empagliflozin, respectively. The recoveries and relative standard deviations were found in the following ranges: 98.80 %–102.00 % and 0.23 %–1.90 % for linagliptin and 98.30 %–101.80 % and 0.11 %–1.86 % for empagliflozin. The detection and quantification limits were 1.13×10?5 and 3.76×10?5 mol L?1 (5.34and17.77 μg/mL) for linagliptin, 1.71×10?6and 5.68×10?6 mol L?1 (0.77 and 2.56 μg/mL) for empagliflozin. The proposed sensors have been successfully applied for the determination of the drugs in bulk, pharmaceutical formulations and biological fluids.  相似文献   

11.
In this paper, the simultaneous separation of several polyphenols such as (+)‐catechin, (–)‐epicatechin, (–)‐epigallocatechin, theophylline, caffeine in green and black teas by capillary electrochromatography (CEC) was developed. Several experimental parameters such as stationary phase type, mobile phase composition, buffer and pH, inner diameter of the columns, sample injection, were evaluated to obtain the complete separation of the analysed compounds. Baseline resolution of the studied polyphenols was achieved within 30 min by using a capillary column (id 100 μm) packed with bidentate C18 particles for 24.5 cm and a mobile phase composed of 5 mM ammonium acetate buffer pH 4 with H2O/ACN (80:20, v/v). The applied voltage and the temperature were set at 30 kV and 20°C. Precision, detection and quantification limits, linearity, and accuracy were investigated. A good linearity (R2 > 0.9992) was achieved over a concentration working range of 2–100 μg/mL for all the analytes. LOD and LOQ were 1 and 2 μg/mL, respectively, for all studied compounds. The CEC method was applied to the analysis of those polyphenols in green and black tea samples after an extraction procedure. Good recovery data from accuracy studies ranged between 90% and 112% for all analytes.  相似文献   

12.
A novel method performing for coulometric backtitrations in flow channels was developed, which ¶was applied for the precise and sensitive determination of low concentrations of nitrite. Under acid conditions nitrite is reacting stoichiometrically with hydrazine, the remained excess of which is backtitrated with electrogenerated bromine. The titration course is recorded either amperometrically or chemiluminometrically. Hydrazine can be determined precisely and accurately in the range between 0.1 μM and 1 mM without calibration. Nitrite is reduced by hydrazine according to the reaction 2 NO2 + 2 H+ + NH2-NH2→N2O + N2 + 3 H2O. Applying the amperometric and the chemiluminometric end-point location nitrite was determined accurately and precisely in the ranges 0.25–65 μM and 0.10–50 μM, respectively. The method was applied to the determination of nitrite in tap and river water.  相似文献   

13.
Meldola′s blue was immobilized into a self-assembled decanethiol monolayer modified on a gold electrode to provide a biological membrane model for electron transport having a molecular gate. Cyclic voltammograms of ferricyanide at this modified electrode showed only its reduction current at potentials where Meldola′s blue was reduced, but not at the redox potential of ferricyanide itself and no reaction was observed for ferrocyanide, indicating the direction of electron flow was controlled through the functionalized monolayer. Similar electrochemical responses were also observed for both octacyanotungustate and octacyanomolybdate. The cathodic peak currents observed in metal cyanide solutions at the modified electrode decreased in the order of Fe(CN)63− > W(CN)83− > Mo(CN)83− at a given pH. From the analysis of the voltammograms using the microelectrode assembly model, the potential-dependent rectified electron flow was explained in terms of a gate function of Meldola′s blue in the monolayer, and the apparent electron transfer rate constant, k0app, and the apparent diffusion coefficient, Dapp, of metal cyanide ions in the monolayer were also estimated.  相似文献   

14.
Tolnaftate, an antifungal drug (TF) and related impurities arising from synthesis, viz., N-methyl-m-toluidine (NMmT) and β-naphthol-1-chlorothio carbamate (β-NCTC) can be determined by supercritical fluid chromatography. Even though it was possible to elute TF completely with neat SCF CO2, the peaks of the impurities were found to merge. The chromatographic figures of merit of the three analytes such as retention time (tR), capacity factor (k|), selectivity factor (α), no. of theoretical plates (N), were optimized. The three compounds can be resolved in 5 min on a Hypersil (250 × 4.0 mm) 5 μ, C18 column with supercritical carbon dioxide, modified with 1.96% methanol as the mobile phase at 9.81 MPa and at 40?°C. Detection was carried out at 220 nm. The data as evaluated by the linear regression least squares fit method gave linearity ranges from 0.2 to 10.0 μg/mL for TF and NMmT and 0.3 to 10.0 μg/mL for β-NCTC with correlation coefficients > 0.99. The method was successfully employed to estimate levels of 0.01% for NMmT and 0.02% for β-NCTC with respect to TF.  相似文献   

15.
A comparison between C18 silica and multi‐walled carbon nanotubes (MWCNTs) in the extraction of Chlorpyrifos and Phosalone in environmental water samples was carried out using HPLC. Parameters affecting the extraction were type and volume of elution solvent, pH and flow rate of sample through the adsorbent. The optimum conditions obtained by C18 cartridge for adsorption of these pesticides were 4 mL dichloromethane as elution solvent, sample pH of 5, flow rate of 1 mL/min, and those for MWCNT cartridge were 3 mL dichloromethane, pH of 5 and flow rate of 10 mL/min, respectively. Optimized mobile phase for separation and determination of these compounds by HPLC was methanol/water (80:20 v/v) with pH=5 (adjusted with phosphate buffer). Under optimal chromatographic and SPE conditions, LOD, linear range and precision (RSD n=8) were 3.03×10?3, 0.01–5.00 μg/mL and 2.7% for Chlorpyrifos and 4.03×10?4, 0.01–5.00 μg/mL and 2.3% for Phosalone, in C18 cartridge, respectively. These values for MWCNT were 4.02×10?6, 0.001–0.500 μg/mL and 1.8% for Chlorpyrifos and 1.02×10?6, 0.001–0.500 μg/mL and 1.5% for Phosalone, respectively.  相似文献   

16.
Chromenone-rhodamine conjugate 1 has been synthesized and its metal ion binding properties have been studied in CH3CN/water (3:1, v/v; 10 mM HEPES buffer; pH = 6.85). Compound 1 senses multiple metal ions such as Al3+ and Hg2+ by exhibiting turn on fluorescence and color change (colorless to pink). Al3+ and Hg2+ ions have been distinguished with the aid of tetrabutylammonium iodide (TBAI). While in the presence of I? the pink color of the 1.Hg2+ complex was completely discharged; under identical conditions the pink color of 1.Al3+ complex was retained.  相似文献   

17.
The effect of the alkali metal nature on the electronic structures and chemical bonding in mixed cyanoferrates M2Cu[Fe(CN)6] (M = Na, K, Rb, and Cs) was studied by ab initio tight-binding linear muffin-tin orbital (TB-LMTO) method (in the spin-polarized implementation) and the extended Hückel molecular orbital (EHMO) method. It was found that the X-ray photoelectron spectra of the ferrimagnetic compounds Na2Cu[Fe(CN)6] (I), K2Cu[Fe(CN)6] (II), Rb2Cu[Fe(CN)6] (III), and Cs2Cu[Fe(CN)6] (IV) are similar. The magnetic moments on Cu2+ and iron ions remain virtually constant in compounds I–IV (μ(Cu) = 0.9 μB, μ(Fe) < ?0.06 μB). Analyses of the electron density maps and the bond overlap populations showed that the cubic frameworks of cyanoferrates are built from stable fragments ?-Fe-C≡N-Cu-?. The bond strength in these fragments decreases substantially in the order C-N → Fe-C → Cu-N and only slight in the order IV → III → II → I. The calculated total energies of the cyanoferrates Cs2?x Cu[Fe(CN)6], CsHCu[Fe(CN)6], and NaHCu[Fe(CN)6] for different concentrations and configurations of defects (cesium vacanices and hydrogen substitution defects) suggest mutual repulsion of defects. This repulsion is responsible for the experimentally observed lowering of the ionic conductivity with an increase in the defect concentration in the mixed cyanoferrates.  相似文献   

18.
Two selective and accurate chromatographic methods are presented for simultaneous quantitation of spironolactone (SP) and furosemide (FR) and canrenone (CN), the main degradation product and the main active metabolite of SP. Method A was HPTLC, where separation was completed on silica gel HPTLC F254 plates using ethyl acetate–triethylamine–acetic acid (9:0.7:0.5, by volume) as a developing system and UV detection at 254 nm. Method B was a green isocratic RP‐HPLC utilizing a C18 (4.6 × 100 mm) column, the mobile phase consisting of ethanol–deionized water (45: 55, v/v) and UV estimation at 254 nm. Adjustment of flow rate at 1 mL/min and pH at 3.5 with glacial acetic acid was done. Regarding the greenness profile, the proposed RP‐HPLC method is greener than the reported one. ICH guidelines were followed to validate the developed methods. Successful applications of the developed methods were revealed by simultaneous determination of FR, SP and CN in pure forms and plasma samples in the ranges of 0.2–2, 0.05–2.6 and 0.05–2 μg/band for method A and 5–60, 2–60 and 2–60 μg/mL for method B for FR, SP and CN, respectively.  相似文献   

19.
Novel films consist of multi-walled carbon nanotubes (MWCNT) were fabricated by means of catalytic chemical vapor deposition (CVD) technique with decomposition of either acetonitrile (ACN) or benzene (BZ) using ferrocene (FeCp2) as catalyst. The electrochemical and thermodynamic behavior of the ferrocyanide/ferricyanide, [Fe(CN)6]3−/4− redox couple on synthesized MWCNT-based films was investigated by means of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques at T = (278.15, 283.15, 293.15, and 303.15) K. The redox couple [Fe(CN)6]3−/4− behaves quasi-reversibly on fabricated MWCNT-based films and its reversibility is enhanced upon increasing temperature. Namely, the findings establish that with the rise in temperature the barrier for interfacial electron transfer decreases, leading, consequently, to an enhancement of the kinetics of the charge transfer process. According to thermodynamics the equilibrium of the redox process is shifted towards the formation of [Fe(CN)6]3− at elevated temperatures.  相似文献   

20.
Dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME–SFO) was for the first time combined with field‐amplified sample injection (FASI) in CE to determine four β2‐agonists (cimbuterol, clenbuterol, mabuterol, and mapenterol) in bovine urine. Optimum BGE consisted of 20 mM borate buffer and 0.1 mM SDS. Using salting‐out extraction, β2‐agonists were extracted into ACN that was then used as the disperser solvent in DLLME–SFO. Optimum DLLME–SFO conditions were: 1.0 mL ACN, 50 μL 1‐undecanol (extraction solvent), total extraction time 1.5 min, no salt addition. Back extraction into an aqueous solution (pH 2.0) facilitated direct injection of β2‐agonists into CE. Compared to conventional CZE, DLLME–SFO–FASI–CE achieved sensitivity enhancement factors of 41–1046 resulting in LODs in the range of 1.80–37.0 μg L?1. Linear dynamic ranges of 0.15–10.0 mg L?1 for cimbuterol and 15–1000 μg L?1 for the other analytes were obtained with coefficients of determination (R2) ≥ 0.9901 and RSD% ≤5.5 (n = 5). Finally, the applicability of the proposed method was successfully confirmed by determination of the four β2‐agonists in spiked bovine urine samples and accuracy higher than 96.0% was obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏