首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A novel platform for electroanalysis of isoniazid based on graphene-functionalized multi-walled carbon nanotube as support for iron phthalocyanine (FePc/f-MWCNT) has been developed. The FePc/f-MWCNT composite has been dropped on glassy carbon forming FePc/f-MWCNT/GC electrode, which is sensible for isoniazid, decreasing substantially its oxidation potential to +200 mV vs Ag/AgCl. Electrochemical and electroanalytical properties of the FePc/f-MWCNT/GC-modified electrode were investigated by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electrochemical microscopy, and amperometry. The sensor presents better performance in 0.1 mol L?1 phosphate buffer at pH 7.4. Under optimized conditions, a linear response range from 5 to 476 μmol L?1 was obtained with a limit of detection and sensitivity of 0.56 μmol L?1 and 0.023 μA L μmol?1, respectively. The relative standard deviation for 10 determinations of 100 μmol L?1 isoniazid was 2.5%. The sensor was successfully applied for isoniazid selective determination in simulated body fluids.  相似文献   

2.
A new voltammetric sensor based on electropolymerization of glycine at glassy carbon electrode (GCE) was developed and applied to determine of pyrazinamide (PZA) by square-wave voltammetry (SWV). The initial cyclic voltammetric studies showed an electrocatalytic activity of poly(Gly)/GCE on redox system of pyrazinamide in 0.1 mol L?1 phosphate buffer solution pH 7.5, with E Pc and E Pa in ?0.85 and ?0.8 V (versus E Ag/AgCl), respectively. Studies at different scan rates suggest that the redox system of pyrazinamide at poly(Gly)/GCE is a process controlled by diffusion in the interval from 10 to 100 mV s?1. Square-wave voltammetry-optimized conditions showed a linear response of PZA concentrations in the range from 0.47 to 6.15 μmol L?1 (R?=?0.998) with a limit of detection (LOD) of 0.035 μmol L?1 and a limit of quantification (LOQ) of 0.12 μmol L?1. The developed SWV-poly(Gly)/GCE method provided a good intra-day (RSD?=?3.75 %) and inter-day repeatability (RSD?=?4.96 %) at 4.06 μmol L?1 PZA (n?=?10). No interference of matrix of real samples was observed in the voltammetric response of PZA, and the method was considered to be highly selective for the compound. In the accuracy test, the recovery was found in the range of 98.2 and 104.0 % for human urine samples and pharmaceutical formulation (tablets). The PZA quantification results in pharmaceutical tablets obtained by the proposed SWV-poly(Gly)/GCE method were comparable to those found by official analytical protocols.  相似文献   

3.
The electrochemical oxidation of fipronil is investigated on unmodified and multi-walled carbon-nanotube (MWCNT)-modified glassy carbon electrodes (GCEs), and its amperometric determination using batch injection analysis (BIA) is demonstrated. An oxidation peak was observed at 1.5 V in a 0.1 mol L?1 HClO4/acetone solution (50:50, v/v) on both surfaces. Although MWCNT-modified GCE provided greater sensitivity, the unmodified GCE showed low RSD value, wider linear range, and reduced adsorption of fipronil or its oxidized products on the electrode surface. A detection limit of 4.7 μmol L?1 and linear range of 25–300 μmol L?1 were obtained using a bare GCE. The method was applied in veterinary formulations with results in agreement with those obtained by high-performance liquid chromatography.  相似文献   

4.
The high-quality CTAB-stabilized gold nanorods (Au NRs) were prepared by the way of seed-mediated protocol. The microstructure and composition of the Au NRs were identified by transmission electron microscopy, field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy and UV–visible spectroscopy. Further, a novel non-enzymatic electrochemical sensor of nitrite based on Au NRs–Nafion-modified glassy carbon electrode (GCE) was successfully developed. Under the optimum experimental conditions, the electrochemical behaviors of nitrite on the Au NRs–Nafion-modified GCE were systematically studied by electrochemical impedance spectroscopy, cyclic voltammetry and chronoamperometry. The electrochemical investigations indicated that the Au NRs–Nafion-modified GCE had a wide linear range of 3.0 × 10?6–6.0 × 10?3 mol L?1, an acceptable sensitivity of 130.9 ± 0.05 μA mM?1 cm?2, a fast response time of 3 s and a low detection limit of 0.64 ± 0.02 μmol L?1 at the signal-to-noise ratio of 3 (S/N = 3). Additionally, the electrochemical sensor also showed good stability and favorable anti-interference capability for the detection of nitrite.  相似文献   

5.
This paper reported a simple method for sulfanilamide determination by redox process electroanalysis of oxidation products (SFDox) formed in situ on glassy carbon electrode. The CV experiments showed a reversible process after applied E acc = + 1.06 V and t acc = 1 s, in 0.1 mol L?1 BRBS (pH = 2.0) at 50 mV s?1. Different voltammetric scan rates (from 10 to 450 mV s?1) suggested that the redox peaks of SFDox on the glassy carbon electrode (GCE) is an adsorption-controlled process. Square-wave voltammetry (SWV) method optimized conditions showed a linear response to SFD from 3.00 to 250.0 μmol L?1 (R = 0.998) with a limit of detection of 0.638 μmol L?1 and limit of quantification of 2.0 μmol L?1. The developed the SWV method was successfully used in the determination of SFD pharmaceutical formulation and human serum. The SFD quantification results in pharmaceutical obtained by SWV-GCE were comparable to those found by official analytical protocols.  相似文献   

6.
In this work, we described an electrochemical sensor using a nanocomposite based on graphene oxide (GO), silver nanoparticles (AgNP), and disordered mesoporous silica (SiO2), which was used for the determination of bisphenol A in water samples. Initially, the hybrid material SiO2/GO was synthesized via sol-gel process, subsequently decorated with AgNP with an approximate 20 nm particle size prepared directly on the surface of the SiO2/GO using N, N-dimethylformamide (DMF) as an agent reducer. A glassy carbon electrode was modified with SiO2/GO/AgNP and used in developing a sensitive electrochemical sensor for the determination of bisphenol A in phosphate buffer 0.1 mol L?1 (pH 7.0). The detection limit was 45.2 nmol L?1 with a linear response range between 1.0 × 10?7 and 2.6 × 10?6 mol L?1 and a sensitivity of 1.27 × 10?7 A mol?1 L. Finally, the optimized electrochemical sensor was used for the quantitation of endocrine interfering in natural waters.  相似文献   

7.
This work describes the development of a simple, fast and low-cost method for determining prazosin (PRA) in pharmaceutical samples by flow injection analysis with multiple-pulse amperometric (FIA-MPA) detection using a boron-doped diamond film electrode. Electrochemical detection of PRA was optimized in phosphate buffer pH 4.0 by cyclic voltammetry, in which PRA presented two oxidation processes around at 0.97 and 1.40 V versus Ag/AgCl (3.0 mol L?1 KCl). In these conditions, PRA also showed one reduction process at ?0.75 V that is dependent on the oxidation processes. Thus, the determination of PRA by FIA-MPA detection consisted on the application of a two-potential waveform, E 1 (generator potential)?=?1.6 V/400 ms and E 2 (collector potential)?=??1.0 V/30 ms, with sample loop of 150 μL and flow rate of 3.0 mL min?1. The method showed good repeatability (RSD?<?3.0 %) and high analytical frequency (70 injections per h). The working linear range was obtained from 2 to 200 μmol L?1 with a limit of detection of 0.5 μmol L?1. The recovery tests in all samples were approximately 100 %, and the results were compared with chromatographic methods.  相似文献   

8.
A new electrochemical sensor was developed for determination of D-penicillamine using glassy carbon electrode which had been modified by gold nanoparticles–reduced graphene oxide nanocomposite (AuNPs/RGO/GCE) in aqueous solution. Cyclic voltammetry, transmission electron microscopy and electrochemical impedance spectroscopy were used for characterization of the modified electrode. The results indicated that the kinetic of oxidation reaction of D-penicillamine at the surface of the electrode was controlled by both diffusion and adsorption processes. In 0.1 mol L?1 phosphate buffer (pH 2.0), the oxidation current increased linearly with concentration of D-penicillamine with a linear range of 5.0 × 10?6 to 1.1 × 10?4 mol L?1 and regression coefficient of R 2 = 0.9972. Theoretical detection limit, defined based on 3σ of the blank signal (n = 9) divided by the slope of the linear regression equation, was 3.9 × 10?6 mol L?1 D-penicillamine using differential pulse voltammetry. The developed method was successfully applied to the determination of D-penicillamine in pharmaceutical formulation and blood serum samples.  相似文献   

9.
This paper is focused on a characterization of bacterial contamination in pool water of the interim spent fuel storage (JAVYS Inc.) in Slovak Republic and on bioaccumulation of 137Cs and 60Co by isolated bacteria. Bacterial community in pool water is kept on very low level by extremely low concentration of solutes in deionized water and by the efficient water filtration system. Based on standard methods and sequencing of 16S rDNA four pure bacterial cultures were identified as Kocuria palustris, Micrococcus luteus, Ochrobactrum spp. and Pseudomonas aeruginosa. Isolated aerobic bacteria were able to bioaccumulate 137Cs and 60Co in laboratory experiments. The mechanism of Co and Cs binding involve rapid interactions with anionic groups of the components of cell surface and in the case of Cs+ ions is followed by transport processes across cytoplasm membranes and by intracellular distribution. The maximum specific uptake of Cs+ after 48 h cultivation in mineral medium (MM) reached 7.54 ± 0.48 μmol g?1 dw (Ochrobactrum spp.), 19.6 ± 0.1 μmol g?1 dw (M. luteus) and 20.1 ± 2.2 μmol g?1 dw (K. palustris). The maximum specific uptake of Co2+ after 24 h cultivation in MM reached 31.1 ± 3.5 μmol g?1 dw (Ochrobactrum spp.), 86.6 ± 12.2 μmol g?1 dw (M. luteus) and 16.9 ± 1.2 μmol g?1 dw (K. palustris). These results suggest that due to the long lasting uptake of 137Cs, 60Co and other radionuclides by biofilm in pool water high specific radioactivities (Bq m?2) can be expected on stainless steel walls of pools.  相似文献   

10.
In this work, a simple method for electroanalytical determination of 17α-ethinylestradiol (EE2) hormone in natural waters was developed using a boron-doped diamond electrode (BDD). The analyses were performed using square wave voltammetry and the parameters were optimized. The results showed a well-defined irreversible oxidation peak (BR buffer 0.1 mol L?1, pH 8.0) at +0.65 V (vs. Ag/AgCl). The voltammetric results showed also that the oxidation process is controlled by adsorption of species and indicated that there are two electrons involved. The obtained analytical curves for 17α-ethinylestradiol presented good linearity in the concentration range 9.9?×?10?7 to 5.2?×?10?6 mol L?1 in utlrapure water and 7.9?×?10?7 to 5.2?×?10?6 mol L?1 in natural water samples (supply dam). Detection limits (DL) obtained were between 2.4?×?10?7 and 7.5?×?10?7 mol L?1 and quantification limits (QL) between 7.9?×?10?7 and 2.5?×?10?6 mol L?1. The recovery experiments showed values between 86 and 114 % for spiked samples thus indicating the applicability of the electroanalytical methodology to quantify 17α-ethinylestradiol directly in natural water of supply Dam (Billings Dam in Diadema-SP. Brazil), without any preconcentration or derivatization.  相似文献   

11.
An electrochemical sensor for theophylline (ThPh) was prepared by electropolymerizing o-phenylenediamine on a glassy carbon electrode in the presence of ThPh via cyclic voltammetry, followed by deposition of gold nanoparticles using a potentiostatic method. The effects of pH, ratio between template molecule and monomer, number of cycles for electropolymerization, and of the solution for extraction were optimized. The current of the electro-active model system hexacyanoferrate(III) and hexacyanoferrate(IV) decreased linearly with successive addition of ThPh in the concentration range between 4.0?×?10?7?~?1.5?×?10?5 mol·L?1 and 2.4?×?10?4?~?3.4?×?10?3 mol·L?1, with a detection limit of 1.0?×?10?7 mol·L?1. The sensor has an excellent recognition capability for ThPh compared to structurally related molecules, can be regenerated and is stable.
Figure
In this paper, an electrochemical sensor for theophylline (ThPh) was prepared by electropolymerizing o-phenylenediamine (o-PD) on a glassy carbon electrode in the presence of ThPh via cyclic voltammetry, followed by deposition of gold nanoparticles to enhance the sensitivity of the sensor. Therefore, the sensor showed a high sensitivity for ThPh determining. Peak current of [Fe(CN)6]3?/[Fe(CN)6]4? varied linearly with the concentration of ThPh in the range of 4.0×10-7~1.5×10-5 mol·L-1 and 2.4×10-4~3.4×10-3 mol·L-1, and the detection limit reached 1.0×10-7 mol·L-1. Compared to structurally related molecules, the sensor also has a high recognition capability for ThPh. With excellent regeneration property and stability, the present sensor maybe provides a new class of polymer modified electrodes for sensor applications.  相似文献   

12.
The preparation of a carbon ceramic electrode modified with SnO2 (CCE/SnO2) using tin dibutyl diacetate as precursor was optimized by a 23 factorial design. The factors analyzed were catalyst (HCl), graphite/organic precursor ratio, and inorganic precursor (dibutyltin diacetate). The statistical treatment of the data showed that only the second-order interaction effect, catalyst × inorganic precursor, was significant at 95% confidence level, for the electrochemical response of the system. The obtained material was characterized by scanning electron microscopy (MEV), X-ray diffraction (XRD), RAMAN spectroscopy, XPS spectra, and voltammetric techniques. From the XPS spectra, it was confirmed the formation of the Si–O–Sn bond by the shift in the binding energy values referred to Sn 3d3/2 due to the interaction of Sn with SiOH species. The incorporation of SnO2 provided an increment of the electrode response for levofloxacin, with Ipa = 147.0 μA for the ECC and Ipa = 228.8 μA for ECC/SnO2, indicating that SnO2 when incorporated into the silica network enhances the electron transfer process. Under the optimized working conditions, the peak current increased linearly with the levofloxacin concentration in the range from 6.21×10?5 to 6.97×10?4 mol L?1 with quantification and detection limits of 3.80×10?5 mol L?1 (14.07 mg L?1) and 1.13×10?5 mol L?1 (4.18 mg L?1), respectively.  相似文献   

13.
In this work, the electrocatalytical properties and kinetic characteristics of new electrodes modified with Pt nanoparticles (PtNPs) and three generations of ferrocene functionalized dendrimers have been investigated as new acetaminophen amperometric sensors. The catalytic synergy of PtNPs with the ferrocene groups is discussed in relation to the ferrocenyl dendrimer generation and their properties. The modified electrodes show excellent catalytic responses toward the oxidation of acetaminophen, with good reproducibility. The overpotential for oxidation of acetaminophen at pH 7 is decreased, and the current response significantly enhanced. The best dendrimer/PtNPs/Pt electrode shows several wide linear concentration ranges for the acetaminophen oxidation from 0 to beyond 17 mM. At 0.5 V vs. SCE, the first linear range extends from 0 to 100 μM (y = 0.0131x ? 0.0028; R 2 = 0.9996) and the last from 10 mM to at least 17 mM (y = 0.0024x + 26.6; R 2 = 0.9977). This fact turns the developed acetaminophen sensor in the device with the widest application range. In addition, the sensor allows measuring acetaminophen in the presence of interfering substances as glucose, dopamine, uric acid, and ascorbic acid, and it has been successfully applied to the determination of acetaminophen in three pharmaceutical formulations.  相似文献   

14.
Growths of Lyngbya limnetica and Oscillatoria obscura were investigated at varying pH, light intensity, temperature, and trace element concentration with a view to optimize these parameters for obtaining the maximum carbohydrate content. The maximum growth for both strains was obtained at pH 9.0 and temperature 20 ± 3 °C using a light intensity of 68.0 μmol m?2 s?1 with continuous shaking. Growth under the nitrogen starvation condition affected the carbohydrate content more compared to the phosphorus starvation, and maximum concentrations were found as 0.660 and 0.621 g/g of dry biomass for L. limnetica and O. obscura, respectively. Under the optimized nitrogen-rich conditions, the specific growth rates for the two strains were found to be 0.187 and 0.215 day?1, respectively. The two-stage growth studies under nitrogen-rich (stage I) followed by nitrogen starvation (stage II) conditions were performed, and maximum biomass and carbohydrate productivity were found as 0.088 and 0.423 g L?1 day?1 for L. limnetica. This is the first ever attempt to evaluate and optimize various parameters affecting the growth of cyanobacterial biomass of L. limnetica and O. obscura as well as their carbohydrate contents.  相似文献   

15.
《Analytical letters》2012,45(7):1321-1332
Abstract

A novel amperometric nitric oxide (NO) sensor based on a glassy carbon electrode modified with thionine and Nafion films has been developed. The oxidation peak current of NO increased significantly at the poly(thionine)/Nafion‐modified glassy carbon electrode (GCE), which can be used for the detection of NO. The oxidation peak current was linear with the concentration of nitric oxide over the range from 3.6×10?7 to 6.8×10?5 mol · L?1, and the detection limit was 7.2×10?8 mol · L?1. This nitric oxide sensor showed high selectivity to nitric oxide determination, and some potential interference could be eliminated effectively. The nitric oxide sensor has been applied to monitor NO release from rat kidney stimulated by L‐arginine. The results indicated the applicability of the NO sensor to biomedical samples.  相似文献   

16.
Formaldehyde is known as a highly toxic compound to humans and identified as a carcinogenic substance. In this study, Hantzsch reaction was utilized for the derivatization of trace amounts of formaldehyde in aqueous samples with acetylacetone in the presence of ammonia to form an extractable colored product named 3,5-diacetyl 1,4-dihydrolutidine (DDL) and its further extraction using two-phase hollow fiber liquid-phase microextraction. The main experimental variables affecting the extraction performance were investigated and optimized. Under the optimum conditions (sample volume 12 mL; reaction temperature 70 °C; ammonium acetate buffer solution 4 mL 0.1 mol L?1; acetylacetone 5 mL 0.15 mol L?1; solvent octanol, salt concentration 20% (w/v) NaCl; pH of donor phase 7.0; stirring speed 400 rpm and extraction time 30 min), the linear dynamic range, limit of detection (LOD as 3S b/m) and relative standard deviation (RSD %) of the proposed method were obtained as 5–250 μg L?1 (r 2 = 0.9979), 3.6 μg L?1 and 2.5%, respectively. Finally, the applicability of the proposed method was examined, and very good results were obtained. The results confirmed the applicability of the proposed method as a versatile, low-cost and sensitive preconcentration method for determination of low concentrations of formaldehyde in aqueous solutions.  相似文献   

17.
18.
In this study, a new procedure for the fabrication of biosensors was developed. The method is based on the covalent attachment of nitrophenyl groups to the electrode surface via diazonium salt reaction followed by their conversion to amine moieties through electrochemical reduction and electrostatic layer-by-layer (LbL) assembly technique. In this procedure, highly stable iron oxide (Fe3O4) nanoparticles (IONPs), chitosan (CHIt), GOx, and Nile blue (NB) were assembled on the surface of aminophenyl modified glassy carbon electrode (AP/GCE) by LbL assembly technique. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the interfaces. The surface coverage of the active GOx and Michaelis–Menten constant (K M) of the immobilized GOx were Γ?=?3.38?×?10?11 mol cm?2 and 2.54 mM, respectively. The developed biosensor displayed a well-defined amperometric response for glucose determination with high sensitivity (8.07 μA mM?1) and low limit of detection (LOD) of 19.0 μM. The proposed approach allows simple biointerface regeneration by increasing pH which causes disruption of the ionic interactions and release of the electrostatic attached layers. The biosensor can then be reconstructed again using fresh enzyme. Simple preparation, good chemical and mechanical stabilities, and easy surface renewal are remarkable advantages of the proposed biosensor fabrication procedure.  相似文献   

19.
We have fabricated, in a single step, carbon ceramic electrodes modified with a poly(acridine orange) film containing reduced graphene oxide. They display electrocatalytic activity to ascorbic acid (AA) and uric acid (UA) at pH 4.5. The anodic peak potentials of AA and UA are separated by 276 mV so that they can be well resolved in cyclic voltammetry. UA and AA were simultaneously determined in a mixture at working potentials of 170 and 400 mV, respectively. Under optimized conditions, the calibration curves for AA and UA cover the 0.8–5,000 μM and 0.6–900 μM concentration range, respectively, while detection limits are 0.3 μM and 0.2 μM. The electrode was applied to determine AA and UA in urine samples.
Figure
DPV curves of RGO–PAO/CCE in the phosphate buffer solution (pH 4.5) containing 5.0?×?10?5 mol L?1 AA with different concentration of UA (a?→?f: 0, 1, 3, 5, 7, 9?×?10?6 mol L?1)  相似文献   

20.
From three cell-associated β-xylosidases produced by Aureobasidium pullulans CBS 135684, the principal enzyme was enriched to apparent homogeneity and found to be active at high temperatures (60–70 °C) over a pH range of 5–9 with a specific activity of 163.3 units (U) mg?1. The enzyme was thermostable, retaining over 80% of its initial activity after a 12-h incubation at 60 °C, with half-lives of 38, 22, and 10 h at 60, 65, and 70 °C, respectively. Moreover, it was tolerant to xylose inhibition with a K i value of 18 mM. The K m and V max values against p-nitrophenyl-β-d-xylopyranoside were 5.57 ± 0.27 mM and 137.0 ± 4.8 μmol min?1 mg?1 protein, respectively. When combining this β-xylosidase with xylanase from the same A. pullulans strain, the rate of black liquor xylan hydrolysis was significantly improved by up to 1.6-fold. The maximum xylose yield (0.812 ± 0.015 g g?1 dry weight) was obtained from a reaction mixture containing 10% (w/v) black liquor xylan, 6 U g?1 β-xylosidase and 16 U g?1 xylanase after incubation for 4 h at 70 °C and pH 6.0.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号