首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A simple, sensitive and selective solid phase microextraction with hollow fiber-supported multi-walled carbon nanotube functionalization reinforced sol–gel combined HPLC method was proposed for the determination of naproxen in tap, well and river water samples. In this method, functionalized multi-walled carbon nanotubes (MWCNTs) were prepared and held in pores of hollow fiber with sol–gel technology by immersion of polypropylene hollow fiber segment into the sol of the functionalized MWCNTs/silica composite and ultrasonically treated at room temperature. Effect of main parameters such as volume of donor phase, pH, extraction time, desorption time, type of desorption solvent, sample ionic strength and stirring rate were studied. Under optimum conditions, linearity was observed in the range of 0.03–500 ng/mL, with correlation coefficients of 0.997. The relative standard deviation for three replicate determinations of 50 ng/mL of naproxen was 4.3%. Limit of detection and pre-concentration factor were 0.008 ng/mL and 198, respectively. In order to check the applicability of the proposed method, it was used to determine trace levels of naproxen in different water samples.  相似文献   

2.
Optimization of extraction and enrichment parameters of chemical warfare agents and their related chemicals from water are presented using multiwalled carbon nanotubes (MWCNTs) as solid-phase extractant. Selected analytes were O,O'-dialkyl alkylphosphonates, nerve agent and mustards. Extraction parameters, including sample volume, nature and volume of washing and eluting solvent, were optimized. Recoveries of analytes were determined by GC-MS and ranged from 81 to 104%. A comparison with C(18), hydrophilic-lipophilic balance and active carbon sorbents demonstrated the superiority of MWCNTs for non-toxic analogues of nerve agents. Optimized conditions involve 40?mg MWCNTs as the sorbent, 5.0?mL water as the washing solvent, 3?mL ethyl acetate as the eluent and sample loading of 10?mL water spiked at 0.1?μg/mL. The limits of detection (LOD) were achieved down to 1 and 0.05?ng/mL in full scan and selected ion-monitoring modes, respectively.  相似文献   

3.
A sensitive and selective preconcentration method using solid-phase extraction (SPE) disk, namely multiwalled carbon nanotubes (MWCNTs) disk, is proposed for the determination of atrazine and simazine in water samples. Atrazine and simazine were extracted on MWCNTs disk and then determined by gas chromatography–mass spectrometry (GC/MS). Several parameters on the enrichment factor of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 5 using 200 mL of validation solution containing 0.1 μg of triazines and 5 mL of acetone as an eluent. The maximum enrichment factors for atrazine and simazine were 3900 ± 250 and 4000 ± 110, respectively when 200 mL of sample solution volume was used. Relative standard deviations for seven determinations were 6.9% (atrazine) and 3.0% (simazine) under optimum conditions. The linear range of calibration curves were 0.1 to 1 ng mL− 1 for each analyte with good correlation coefficients. The detection limits (3S/N) were 2.5 and 5.0 pg mL− 1 for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of atrazine and simazine in environmental water samples with high precision and accuracy.  相似文献   

4.
In this paper, a novel flow chemiluminescence (CL) clenbuterol sensor based on molecularly imprinted polymer (MIP) on line enrichment nanogram clenbuterol and chemiluminescence reaction of potassium permanganate and formaldehyde in the polyphosphate enhanced by clenbuterol. Clenbuterol in the urine was selectively adsorbed on the clenbuterol-imprinted polymer, which was packed into the flow cell. The formaldehyde and the polyphosphate with potassium permanganate flowed through the flow cell and reacted with the on line adsorbed clenbuterol and produced strong CL. The results show that the sensor was reversible. The CL intensity was linear with clenbuterol concentration from 1.0 × 10−9 g/mL to 5.0 × 10−8 g/mL. The detection limit was 3.0 × 10−10 g/mL. The R.S.D. for ng/mL clenbuterol was less than 5% (n = 3). The present method offered a high selectivity and sensitivity that made the quantitative analysis of trace clenbuterol (ng/mL) in the animal urine sample.  相似文献   

5.
A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2+ ions are adsorbed selectively and quantitatively during the passage. The retained copper ions were desorbed from the potassium tetratitanate whisker with 10.0mL of 2mol/L sulphuric acid solutions as eluent and were determined by FAAS. The linear range was 0.05μg/mL-0.20μg/mL in the original solution with a correlation coefficient of 0.9998. The detection limit of the proposed method is 2. lng/mL in the original solution (3σ, n=9). Determination of copper in standard ions showed that the proposed method has good accuracy (recovery was more than 95%). The method was successfully applied for recovery and determination of copper in cereals food samples  相似文献   

6.
Thallium in potassium chloride and electrolyte replenishers was determined by electrothermal atomic absorption spectrometry (ETAAS) with direct injection of a resin suspension. Thallium(III) was extracted on fine particles of a cellulose nitrate resin (CNR) from dilute HCl (pH 1.6) in the presence of ammonium pyrrolidine-1-carbodithioate. The CNR particles were collected on a membrane filter by filtration under suction, suspended in 1.0 mL 10mM HNO3, and then delivered directly to ETAAS as the suspension. The effects of chloride ions were thoroughly investigated. The results showed that the addition of 0.5mM NaCl to the suspension (10mM HNO3) was recommended, after CNR and a membrane filter holding the CNR were washed thoroughly with 0.025M HCl, to eliminate interference from chloride ions. No chemical modifier was required. Extraction from the solution containing up to 2M chloride ion was allowable. The proposed method gave a concentration factor of 50 for a 50 mL sample volume. The detection limit (3sigma, n = 5) was 1 ng (20 pg/mL). The relative standard deviation was 4.9% (n = 5) at 30 ng level of thallium. The content of thallium in potassium chloride was 15.7-32.8 ng/g, and in electrolyte replenishers was 0.18-4.16 ng/mL.  相似文献   

7.
A novel headspace gas chromatographic (HS-GC) method is demonstrated for an indirect determination of oxalate in oxygen delignification liquors. A small volume (50-100 microL) of liquor sample is introduced into a sampling vial that contains 1.0 mL of 2 mol/L sulfuric acid. After removal of carbon dioxide (generated from carbonate in the acidic medium) by heating, the sample was mixed with a 0.5 mL of 0.02 mol/L potassium permanganate solution in a closed testing vial. At an elevated temperature (70 degrees C), the oxalate in the sample is rapidly converted to carbon dioxide by reacting with permanganate. The carbon dioxide in the headspace can be measured by gas chromatography with a thermal conductive detector. Using a multiple headspace extraction (MHE) measurement technique, the kinetics of formation of the carbon dioxide from the other organic species in the sample can be determined, and thus a correction can be made for minimizing the interferences. The present method is simple, accurate and can be easily automated.  相似文献   

8.
The adsorption behavior of multiwalled carbon nanotubes (MWNTs) toward copper has been investigated systemically, and a new method has been developed for the determination of trace copper in water samples based on preconcentration with a microcolumn packed with MWNTs prior to its determination by flame atomic absorption spectrometry. The optimum experimental parameters for preconcentration of copper, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. Copper can be quantitatively retained by MWNTs in the pH range 5-8, and then eluted completely with 0.5 M HNO3. The detection limit of this method for Cu was 0.42 ng/mL, and the RSD was 3.5% at the 10 ng/mL Cu level. The method was validated using a certified reference material, and has been successfully applied for the determination of trace copper in water samples.  相似文献   

9.
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of diazinon. Diazinon was preconcentrated on multiwalled carbon nanotubes (MWCNTs) as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 6 using 200 mL of validation solution containing 2 μg of diazinon and 5 mL of acetonitrile as an eluent. Recovery of diazinon was 95.2 ± 4.2% with a relative standard deviation for seven determinations of 4.9% under optimum conditions. The maximum preconcentration factor was 200 for diazinon when 1000 mL of sample solution volume was used. The linear range of calibration curve was 0.3 to 10,000 ng mL− 1 with a correlation coefficient of 0.997 and the detection limit (3S/N) was 0.06 ng mL− 1. The proposed method was successfully applied to the determination of diazinon in tap water with high precision and accuracy.  相似文献   

10.
W Gao  X Sun  T Chen  Y Lin  Y Chen  F Lu  Z Chen 《Journal of separation science》2012,35(15):1967-1976
In the present work, we showed a novel method to synthesize cyano-functionalized multiwalled carbon nanotubes (MWCNTs-CN) and utilize it as a solid-phase extraction sorbent for preconcentration of phenolic compounds in environmental water samples. MWCNTs-CN was synthesized through surface functionalization of multiwalled carbon nanotubes (MWCNTs). The functional groups on the surface of modified MWCNTs were characterized by Fourier transform infrared spectroscopy, thermogravimetric analysis and scanning electron microscopy. The analytical procedure was based on a conventional solid-phase extraction step for which 100 mg of MWCNTs-CN were packed in a 3 mL polypropylene cartridge. Analytes were thus isolated and preconcentrated from the pretreated samples and subsequently detected on high-performance liquid chromatography-ultraviolet detection. The results showed the proposed method exhibited good sensitivity and precision for the extraction and elution of analytes. The limit of detections (S/N = 3) of the method were 0.45, 0.09, 0.08, and 3.00 ng mL(-1) for p-chlorophenol, 1-naphthol, 2-naphthol, and 2,4-dichlorophenol, respectively. The mean relative recoveries (n = 3) were between 80.28 and 103.13%, and the repeatability (RSD ≤ 5.10%) and reproducibility (RSD ≤ 7.68%) were accepted. This developed method was applied to determine phenolic compounds in environmental water samples. There is a positive result only for 2-naphthol with concentration of 0.38 ng mL(-1) in seawater sample.  相似文献   

11.
A new simple and reliable method has been developed to separate and preconcentrate trace copper ion in drinking water and tea samples for subsequent measurement by flame atomic absorption spectrometry (FAAS). The copper ions are adsorbed quantitatively during passage of aqueous solutions through Amberlyst 36 cation exchange resin. After the separation and preconcentration stage, the analyte was eluted with a potassium cyanide solution and determined by FAAS. Different factors including pH of sample solution, sample volume, amount of resin, flow rate of aqueous solution, volume and concentration of eluent, and matrix effects for preconcentration were examined. The analytical figures of merit for the determination of copper are as follows: analytical detection limit (3 sigma), 0.26 microg/L; precision (RSD), 3.1% for 100 microg/L; enrichment factor, 200 (using 1000 mL of sample solution and 5 mL of eluent); time of analysis, 3.5 h (for obtaining enrichment factor of 200); capacity of resin, 125 mg/g. The method was applied for copper determination by FAAS in tap water, commercial natural spring water, commercial treated drinking water, and commercial tea bag sample. The accuracy of the method is confirmed by analyzing tea leaves (GBW 07605). The results demonstrated good agreement with the certified values.  相似文献   

12.
This paper described a new method for the trace determination of fenpropathrin, cyhalothrin and deltamethrin using multiwalled carbon nanotubes (MWCNTs) cartridge. Important parameters, such as the sample pH, eluent and its volume, sample flow rate and sample volume were investigated in detail. The linear ranges, the detection limits, and precisions (R.S.D.) were in the range of 0.1- 40 μg L^-11, 1.34.3 ng L^-1 and 2.3-2.8%, respectively. The performance of the proposed method was validated with real water samples, and the spiked recoveries were in the range of 91.7-117.8%, respectively. The experimental results demonstrated that the proposed method was an excellent alternative for the routine analysis of such pollutants in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.  相似文献   

13.
Using bamboo‐activated charcoal as SPE adsorbent, a novel SPE method was developed for the sensitive determination of tetrabromobisphenol A and bisphenol A in environmental water samples by rapid‐resolution LC‐ESI‐MS/MS. Important parameters influencing extraction efficiency, including type of eluent, eluent volume, sample pH, volume and flow rate, were investigated and optimized. Under the optimal extraction conditions (eluent: 8 mL methanol, pH: 7; flow rate: 4 mL/min; sample volume: 100 mL), low LODs (0.01–0.02 ng/mL), good repeatability (6.2–8.3%) and wide linearity range (0.10–10 ng/mL) were obtained. Satisfied results were achieved when the proposed method was applied to determine the two target compounds in real‐world environmental water samples with spiked recoveries over the range of 80.5–119.8%. All these facts indicate that trace determination of tetrabromobisphenol A and bisphenol A in real‐world environmental water samples can be realized by bamboo‐activated charcoal SPE‐rapid resolution‐LC‐ESI‐MS/MS.  相似文献   

14.
Based on the chemiluminescence (CL) emission generated from the oxidation of ceftriaxone sodium alkali hydrolysate by potassium permanganate in polyphosphoric acid (PPA), a novel determination method for ceftriaxone sodium was developed by using a flow-injection technique. The calibration curve appears to be linear in the range between 0.05 and 100 microg mL(-1) with a detection limit (3sigma) of 25 ng mL(-1), and a relative standard deviation (RSD) of 0.6% for eleven replicate determinations of 5.0 microg mL(-1) ceftriaxone sodium. The proposed method has been successfully utilized for the determination of ceftriaxone sodium in pharmaceutical formulations, while the chemiluminescence reaction mechanisms were investigated.  相似文献   

15.
In this study, flow injection-cloud point extraction (FI-CPE) of iron and copper in food samples by flame atomic absorption spectrometric determination was described. Triton X-114 non-ionic surfactant and Eriochrome Cyanine R (ECR) have been used as an extraction medium and a chelating agent, respectively. The amounts of Triton X-114, ECR and the pH value necessary for extraction were carefully optimized. In addition, several parameters of the FI-CPE system, including sample loading rate, column dimension, type of packing material, eluent flow rate were investigated and analytical characteristics of the method were evaluated. Under optimum conditions, detection limits of 0.33 ng/mL and 0.57 ng/mL and quantification limits of 1.1 ng/mL and 1.9 ng/mL for iron and copper along with enrichment factors of 141 and 99 were obtained, respectively. The calibration was linear over the range 1.5-25 ng/mL and 1.0-35 ng/mL for iron and copper, respectively. The proposed CPE technique has been successfully applied for the determination of iron and copper ions in certified reference materials (NCS DC 73349—bush, branches and leaves; and TM-23.2—fortified water), water samples (mineral and sea water) and food samples (vegetables, bread and hazelnut) with high efficiency.  相似文献   

16.
研究了氢化物发生原子吸收法测定包头矿中痕量砷、锑、铋的分析方法,试验确立了反应条件,建立了以KI、抗坏血酸、硫脲为还原体系,消除试样中共存元素的干扰,利用KMnO4消除锑对砷的干扰.砷、锑、铋的检出限可分别达到:0.15,0.28,0.15 ng/mL.方法已用于包头矿分析.  相似文献   

17.
A chemiluminescence method with potassium permanganate was developed for use as an indicator of organic pollutants in fresh water. This method could be applied to the determination of organic pollutants in seawater as well. However, the flow chemiluminescence method suffered from the interference of chloride ions at the same concentration of seawater because of the production of manganese dioxide in the oxidation of chloride ions with permanganate. The conditions (concentrations of potassium permanganate and sulfuric acid and sample volume, i.e. flow injection method) were chosen to minimize the interference of chloride ions. The chemiluminescence method shows a good correlation with the chemical oxygen demand method on fresh water added artificial sea salt and seawater samples. Natural seawater was analyzed by the chemiluminescence method. The results obtained were compared with those obtained by chemical oxygen demand under the alkaline condition and total organic carbon methods. The chemiluminescence method has higher sensitivity and reproducibility than the conventional chemical oxygen demand and total organic carbon methods.  相似文献   

18.
Multiwalled carbon nanotubes (MWCNTs) were used as a novel kind of solid-phase extraction adsorbents in this work as well as an analytical method based on MWCNTs solid-phase extraction (SPE) combined with high-performance liquid chromatography (HPLC) was established for the determination of polycyclic aromatic hydrocarbons (PAHs), some of which belong to typical persistent organic pollutants (POPs) owing to their carcinogenicity and endocrine disrupting activity. Several conditions that probably affected the extraction efficiency including the eluent volume, sample flow rate, sample pH and the sample volume were optimized in detail. The characteristic data of analytical performance were determined to investigate the sensitivity and precision of the method, and the method was applied to the determination of PAHs in environmental water samples such as river water sample, tap water sample and wastewater sample from the constructed wetland effluent. The experimental results indicated that there were excellent linear relationship between peak area and the concentration of PAHs over the range of 0.04-100 microg L(-1), and the precisions (RSD) were 1.7-4.8% under the optimal conditions. The detection limits of proposed method for the studied PAHs were 0.005-0.058 microg L(-1) (S/N=3). The recoveries of PAHs spiked in environmental water samples ranged from 78.7 to 118.1%. It was concluded that MWCNTs packed cartridge coupled with HPLC was an excellent alternative for the routine analysis of PAHs at trace level.  相似文献   

19.
The use of ram horn powder (RHP) as a new sorbent for the preconcentration of copper(II) was proposed. The procedure is based on the adsorption of copper(II) ions as 1-nitroso-2-naphthol-3,6-disulfonic acid chelate onto the minicolumn packed with RHP followed by the elution with 5 mL 1 M HCl and determination by flame atomic absorption spectrometry (FAAS). Analytical variables such as pH, eluent type, flow rate, and sample volume were optimized, and analytical parameters such as accuracy and limit of detection were studied. The optimum pH of the sample solution was found to be in a range of 4–8. The enrichment factor when using a sample volume of 500 mL was 100. The capacity of the sorbent was found to be 1.7 mg/g. The limit of detection for copper(II) was 0.42 μg/L. The accuracy of the method was confirmed by analyzing the lead base alloy and aluminum base alloy (NBS SRM 53e, NBS SRM 85b). The results demonstrated good agreement with the certified values. The procedure was applied to the determination of copper in aluminum foil and different waters, such as tap water, lake water, dam water, and synthetic seawater samples. The text was submitted by the authors in English.  相似文献   

20.
研究了硫酸介质中,高锰酸钾氧化柳氮磺吡啶(SASP)体系的荧光特性,结合流动注射进样技术,建立了流动注射在线氧化荧光分析测定SASP的新方法。SASP本身不发荧光,但在硫酸介质中与高锰酸钾反应后可产生1种有强荧光的产物(λex=301 nm,λem=366 nm)。在优化条件下,SASP的质量浓度在1.2×10-5~2.0×10-3 g/L范围内与相对荧光强度呈良好线性,相关系数为0.999 6。方法的检出限为3.0×10-6 g/L,对1.2×10-4 g/L的SASP标准溶液平行测定11次的相对标准偏差为0.6%。该法简单、快速、灵敏度高、选择性好,可用于药物制剂中SASP含量的直接分析。  相似文献   