首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Surface-activated chemical ionization (SACI) was employed for the analysis of cocaine and its metabolite, benzoylecgonine, extracted from hair. Following decontamination and acid hydrolysis procedures on the hair sample, the sample solution was diluted (1:10) and directly analyzed by liquid chromatography/surface-activated chemical ionization multiple collisional stage single reaction monitoring mass spectrometry (LC/SACI-MS(3)-SRM) without solid-phase extraction (SPE) pre-purification and concentration procedures. To increase the selectivity of the method, MS(3) was chosen instead of the less selective MS/MS. This data was compared with that achieved using gas chromatography/mass spectrometry (GC/MS), the reference method used by the Italian Government Institute of Health protocol. The limits of detection (LODs) were 0.003 ng/(mg hair) for cocaine and 0.02 ng/(mg hair) for benzoylecgonine and the limits of quantitation (LOQs) were 0.01 ng/(mg hair) for cocaine and 0.04 ng/(mg hair) for benzoylecgonine. The squared correlation coefficient (R(2)) of the calibration curve was 0.9887-0.9980 for cocaine and 0.9987-0.9997 for benzoylecgonine. The percent accuracy error was 2-5% for both cocaine and benzoylecgonine using the LC/SACI-MS(3)-SRM approach, whereas it was higher for benzoylecgonine (20-25%) using the LC/SACI-MS/MS-SRM approach compared with the GC/MS data due to hair matrix contamination. In both cases, high precision was achieved (1-3% precision error), which confirmed the stability of the developed methods.  相似文献   

2.
This article describes an easy and innovative extraction procedure for cocaine and its primary metabolite, benzoylecgonine (BE), from hair consisting of sonication with H2O/0.1% formic acid for 4 h. The same extract was used for screening with an enzyme-linked immunoassay (ELISA) and confirmation by liquid chromatography–tandem mass spectrometry (LC–MS/MS). For the ELISA screening test a cutoff of 0.5 ng/mg was used according to the Society of Hair Testing recommendations. LC–MS/MS limits of detection (LODs) were established to be 10 pg/mg and 1 pg/mg for cocaine and BE, respectively. Linearity was obtained over a range of 0.2–5 ng/mg for BE (target analyte) in the ELISA screening test, while in the LC–MS/MS method the range was 0.10–10 ng/mg for cocaine and 0.01–10 ng/mg for BE. Intra- and interbatch coefficients of variation and mean relative errors were less than 20% for all analytes and concentrations studied. The validated ELISA and LC–MS/MS methods were applied to 48 hair samples and the results of both methods were compared; ELISA demonstrated a sensitivity and specificity of 89.2% and 10.8%.  相似文献   

3.
The development of analytical techniques that enable the use of hair as an alternative matrix for the analysis of drugs of abuse is useful for confirming the exposure in a larger time window (weeks to months, depending on the length of the hair shaft). In the present study a methodology aimed at the simultaneous quantification of cocaine and morphine in human hair was developed and validated. After decontamination, hair samples (20?mg) were incubated with a mixture of methanol/hydrochloric acid (2:1) at 65?°C overnight (~16?h) in order to extract the drugs of the matrix. Purification was performed by solid-phase extraction using mixed-mode extraction cartridges. After derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide, blank, standards and samples were analyzed by gas chromatography/electron impact-mass spectrometry (GC-EI/MS). The method proved to be selective, as there were no interferences of endogenous compounds with the same retention time as cocaine, morphine and ethylmorphine (internal standard). The regression analysis for both analytes showed linearity in the range 0.25-10.00?ng/mg with correlation coefficients ranging from 0.9989 to 0.9991. The coefficients of variation oscillated between 0.83 and 14.60%. The limits of detection were 0.01 and 0.02?ng/mg, and the limits of quantification were 0.03 and 0.06?ng/mg for cocaine and morphine, respectively. The proposed GC-EI/MS method provided an accurate and simple assay with adequate precision and recovery for the quantification of cocaine and morphine in hair samples. The proof of applicability was performed in hair samples obtained from drug addicts enrolled in a Regional Detoxification Treatment Center. The importance of hair samples is highlighted, since positives results were obtained when urine immunoassay analyses were negative. Copyright ? 2012 John Wiley & Sons, Ltd.  相似文献   

4.
A validated method for simultaneous LCMSMS quantification of nicotine, cocaine, 6-acetylmorphine (6AM), codeine, and metabolites in 100 mg fetal human brain was developed and validated. After homogenization and solid-phase extraction, analytes were resolved on a Hydro-RP analytical column with gradient elution. Empirically determined linearity was from 5–5,000 pg/mg for cocaine and benzoylecgonine (BE), 25–5,000 pg/mg for cotinine, ecgonine methyl ester (EME) and 6AM, 50-5000 pg/mg for trans-3-hydroxycotinine (OH-cotinine) and codeine, and 250–5,000 pg/mg for nicotine. Potential endogenous and exogenous interferences were resolved. Intra- and inter-assay analytical recoveries were ≥92%, intra- and inter-day and total assay imprecision were ≤14% RSD and extraction efficiencies were ≥67.2% with ≤83% matrix effect. Method applicability was demonstrated with a postmortem fetal brain containing 40 pg/mg cotinine, 65 pg/mg OH-cotinine, 13 pg/mg cocaine, 34 pg/mg EME, and 525 pg/mg BE. This validated method is useful for determination of nicotine, opioid, and cocaine biomarkers in brain.  相似文献   

5.
A fast and sensitive liquid chromatography/triple quadrupole tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous determination of morphine, codeine, 6‐acetylmorphine (6‐AM), cocaine and benzoylecgonine (BE) in hair. Pulverized hair samples were extracted with methanol, and a 50 µL supernatant aliquot was injected into the LC/MS/MS system. Chromatography was performed with an XBridge? phenyl column (3.5 µm particle size, 4.6 × 150 mm), and the mobile phase was composed of methanol and 10 mM ammonium acetate adjusted to pH 4.00 with 99% formic acid (95:5, v/v). A separation run with isocratic elution was completed in 10 min at a flow rate of 500 µL/min. Positive electrospray ionization and multiple reaction monitoring (MRM) with one precursor ion/product ion transition were used for the identification of each analyte. Deuterated analogues as internal standards were used for quantification and qualification. Linearity was established in the concentration range of 100–3000 pg/mg. The limits of detection were 10 pg/mg for morphine, codeine and 6‐AM; and 1 pg/mg for cocaine and BE. The precision and accuracy were determined by spiking hair samples at six concentration levels. For all analytes, the relative standard deviations of intra‐ and inter‐day precision were 0.1–6.3% and 1.5–10.6%, respectively. The accuracy ranged from 92.7 to 109.7%. The validated LC/MS/MS method was successfully applied to the analysis of 79 authentic hair samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
A simple and sensitive gas chromatography/tandem mass spectrometry (GC/MS/MS) method is described for the detection of anabolic steroids, usually found in keratin matrix at very low concentrations. Hair samples from seven athletes who spontaneously reported their abuse of anabolic steroids, and in a single case cocaine, were analyzed for methyltestosterone, nandrolone, boldenone, fluoxymesterolone, cocaine and its metabolite benzoylecgonine. Anabolic steroids were determinate by digestion of hair samples in 1 m NaOH for 15 min at 95 degrees C. After cooling, samples were purificated by solid-phase and liquid-liquid extraction, then anabolic steroids were converted to their trimethylsilyl derivative and finally analyzed by GC/MS/MS. For detection of cocaine and benzoylecgonine, hair samples were extracted with methanol in an ultrasonic bath for 2 h at 56 degrees C then overnight in a thermostatic bath at the same temperature. After the incubation, methanol was evaporated to dryness, and benzoylecgonine was converted to its trimethylsilyl derivative prior of GC/MS/MS analysis. Results obtained are in agreement with the athletes' reports, confirming that hair is a valid biological matrix to establish long-term intake of drugs.  相似文献   

7.
Miyaguchi H  Inoue H 《The Analyst》2011,136(17):3503-3511
An LTQ Orbitrap XL hybrid mass spectrometry method was developed for the determination of illicit drugs and their metabolites, including amphetamine (AP), methamphetamine (MA), dimethylamphetamine (DMA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), ketamine (KET), norketamine (NK), cocaine (COC) and benzoylecgonine (BE), in hair. Micropulverized extraction was employed for sample preparation using a small hair sample (2 cm piece or 0.2 mg). Recoveries of the analytes during sample preparation were estimated using fortified hair samples and ranged from 35.5% for COC to 71.7% for AP. High resolution full-scan mass spectra and unit resolution product-ion spectra were obtained with the Orbitrap analyzer and the linear ion-trap analyzer, respectively. High-resolution extracted ion chromatograms at a tolerance of 3 ppm were utilized for quantification. The analytes were identified using the product-ion spectra in combination with the accurate masses of the corresponding protonated molecules observed in the high-resolution mass spectra. Lower limits of quantification obtained from a 0.2 mg hair sample were 0.050 ng mg(-1) (MDMA, KET and BE), 0.10 ng mg(-1) (AP, MA, DMA, NK and COC) and 0.50 ng mg(-1) (MDA). Two reference materials were analyzed for verification, and segmental analysis of single strands of hair specimens from actual cases was performed.  相似文献   

8.
建立了提取和清洗整合成一步的超声辅助-固相分散溶液提取离子色谱法测定染发剂中的9种染料中间体的方法。样品基质经分散后,测定组分进入溶液,油脂溶解在正己烷中,干扰化合物被分散剂吸附。在振荡、超声和加热的协同作用下,9min内快速完成提取,具有高的样品处理效率。用离子色谱法测定商业染发剂中的中间体以确定方法的提取效率。方法的线性范围为0.2~100mg/L,检出限0.019~0.048mg/L,回收率85.0%~107.0%,相对标准偏差0.3%~3.7%。实验结果表明,方法简单、可靠,适用于大批量样品的常规分析。  相似文献   

9.
A simple and rapid method for the determination of methadone and its main metabolite EDDP in hair has been developed and validated. The analytes were completely extracted from the matrix after a short alkaline incubation, and the extracts were further cleaned up by solid‐phase extraction using mixed‐mode cartridges. Linearity was obtained from 0.1 (lower limit of quantitation, LLOQ) to 30 ng/mg for both compounds, with correlation coefficients higher than 0.99. Intra‐ and interday precision and accuracy were in conformity with internationally accepted guidelines for bioanalytical method validation, and the cleanup procedure presented mean extraction efficiencies higher than 90% for both analytes. This high efficiency greatly contributed to the low limits of quantitation achieved, and therefore this method can be successfully applied in the determination of methadone and EDDP in hair samples in clinical and forensic scenarios where these compounds are involved. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
This study reports the development and validation of a method using hydrophilic interaction liquid chromatography–tandem mass spectrometry (HILIC-MS/MS) for the analysis of cocaine and its metabolites benzoylecgonine (BE), ecgonine methyl ester (EME), and cocaethylene (CE) in hair samples. Decontamination was performed as follows: Firstly, the aliquot of hair was briefly rinsed with 2 mL dichloromethane, then was washed three times with 10 mL 0.01 M phosphate buffer, pH 6, for 15 min, followed by 2 mL 2-propanol for less than 2 min, and, finally, a last rinse with 2 mL dichloromethane was again done. Cocaine compounds were extracted from 10 mg of hair by incubation with 2 mL 0.1 M HCl at 50 °C for 12 h and purified by solid phase extraction with Oasis MCX cartridges. Analysis was performed by LC-MS/MS using an Atlantis HILIC silica chromatographic column. The method was fully validated. Linearity was established over the concentration range 0.020–10.0 ng/mg for cocaine (COC), 0.010–10.0 ng/mg for BE and CE, and 0.005–2.0 ng/mg for EME, and the correlation coefficients were all >0.99. Extraction efficiency was >70% for all analytes. Limits of detection were 0.0005 ng/mg for CE and 0.001 ng/mg for the other analytes (COC, BE, and EME). Lower limits of quantification were the lowest points of the calibration curves with acceptable accuracy and precision (coefficient of variation ≤20%). Intra- and inter-day imprecision ranged between 1.5% and 9.5% and 0.7% and 12.6%, respectively. Intra- and inter-day inaccuracy ranged from 0.5% to 12.3% and from 0.7% to 7.1%, respectively. With regard to matrix effects, suppression was <27.5% in all cases. The method was applied to the analysis of several samples derived from forensic cases.  相似文献   

11.
The techniques of continuous-flow fast-atom bombardment (CF-FAB) and tandem mass spectrometry (MS/MS) are combined and applied to the analysis of small molecular mass drugs (mol.wt less than 500 Da). The approach involves the interfacing of a CF-FAB inlet with a triple-stage quadrupole mass spectrometer, enabling the acquisition of collision-activated decomposition mass spectra of the drugs after FAB ionization. The relationship between a stable sample surface on the CF-FAB probe tip and the quality of the mass spectrum is discussed, as are practical methods for obtaining and maintaining surface stability. CF-FAB MS/MS spectra for several drugs are presented, including penicillin G, phentolamine, cocaine and benzoylecgonine. Minimum detection limits range from 50-500 pg injected, depending on the compound. The reproducibility of the integrated areas of peaks from repetitive injections is approximately five per cent. Data are also presented for the direct CF-FAB MS/MS analysis of cocaine and benzoylecgonine in spiked urine samples.  相似文献   

12.
For analysis of hair samples derived from a pilot study (‘in vivo’ contamination of hair by sidestream marijuana smoke), an LC‐MS/MS method was developed and validated for the simultaneous quantification of Δ9‐tetrahydrocannabinolic acid A (THCA‐A), Δ9‐tetrahydrocannabinol (THC), cannabinol (CBN) and cannabidiol (CBD). Hair samples were extracted in methanol for 4 h under occasional shaking at room temperature, after adding THC‐D3, CBN‐D3, CBD‐D3 and THCA‐A‐D3 as an in‐house synthesized internal standard. The analytes were separated by gradient elution on a Luna C18 column using 0.1% HCOOH and ACN + 0.1% HCOOH. Data acquisition was performed on a QTrap 4000 in electrospray ionization‐multi reaction monitoring mode. Validation was carried out according to the guidelines of the German Society of Toxicological and Forensic Chemistry (GTFCh). Limit of detection and lower limit of quantification were 2.5 pg/mg for THCA‐A and 20 pg/mg for THC, CBN and CBD. A linear calibration model was applicable for all analytes over a range of 2.5 pg/mg or 20 pg/mg to 1000 pg/mg, using a weighting factor 1/x. Selectivity was shown for 12 blank hair samples from different sources. Accuracy and precision data were within the required limits for all analytes (bias between ?0.2% and 6.4%, RSD between 3.7% and 11.5%). The dried hair extracts were stable over a time period of one to five days in the dark at room temperature. Processed sample stability (maximum decrease of analyte peak area below 25%) was considerably enhanced by adding 0.25% lecithin (w/v) in ACN + 0.1% HCOOH for reconstitution. Extraction efficiency for CBD was generally very low using methanol extraction. Hence, for effective extraction of CBD alkaline hydrolysis is recommended. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
A high performance liquid chromatography-high resolution mass spectrometry (HPLC-HRMS) method for simultaneous screening and quantification of 28 drugs was developed and validated for 2.5 mg hair samples. Target drugs and their metabolites included amphetamines, cocaine, opioids, benzodiazepines, antidepressants, and hallucinogens. After decontamination, hair samples were extracted with 200 μL of a mixture of water: acetonitrile:1 M trifluoroacetic acid (80:10:10, v/v) using a 5 min simultaneous pulverization/extraction step. The extracts were analysed by HPLC-HRMS in an Orbitrap at a nominal resolution of 60,000, with concomitant in source collisional experiments (in source CID). Gradient elution on an Atlantis T3 column resolved 28 target compounds and 5 internal standards. Total chromatographic run time was 26 min. Calibration was achieved by linear regression analysis utilizing six calibration points; R2 ranged from 0.9964 to 0.9999, the limits of quantification were 0.1 ng/mg for 8 compounds, 0.2 ng/mg for 16 compounds and 0.5 ng/mg for 4 compounds; mean relative errors from -21% to +23% were obtained; relative standard deviation, used to estimate repeatability and intermediate reproducibility at three concentrations, was always less than 20%. Process efficiency and recoveries for all analytes were better than 65 and 73%, respectively, at any concentration. The method was applied to hair samples from forensic investigations that contained a broad assortment of drugs of abuse and pharmaceuticals. The use of concomitant HRMS full scan and CID afforded the possibility of retrospective analysis for discovering untargeted drugs.  相似文献   

14.
《Analytical letters》2012,45(11):2307-2316
Abstract

This paper describes a gas chromatography‐mass spectrometry method for the simultaneous detection of opiates, cocaine, and benzoylecgonine from human hair samples. Conditioning samples were extracted with Waters Oasis HLB (hydrophilic‐lipophilic balance) cartridges. The detector response was linear for the drugs studied over the range 0.5–20 ng/mg. The limits of quantitation and detection were found to be acceptable. Intra‐ and interbatch coefficients of variation oscillated between 0.2 and 17.9%, and mean relative errors were in the range of 0.04–18.2%. The recoveries were higher than 66.7% in all cases. Finally, the method was applied to 20 hair samples from drug users, obtaining positive results in all cases.  相似文献   

15.
The sensitivity and specificity of a novel method of screening for cocaine in hair, based on matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry (MS), have been evaluated. The method entails a rapid extraction procedure consisting of shaking 2.5 mg pulverised hair at high frequency in the presence of an acidic solution (160 μL of water, 20 μL of acetonitrile and 20 μL of 1 M trifluoroacetic acid) and a stainless-steel bullet. Following centrifugation, the supernatant is dried under a nitrogen stream, and the residue is reconstituted in 10 μL of methanol/trifluoroacetic acid (7:3; v/v). One microlitre of the extract is deposed on a MALDI sample holder previously scrubbed with graphite; an α-cyano-4-hydroxycinnamic acid (matrix) solution is electrosprayed over the dried sample surface to achieve a uniform distribution of matrix crystals. The identification of cocaine is obtained by post-source decay experiments performed on its MH+ ion (m/z 304), with a limit of detection of 0.1 ng/mg of cocaine. A total of 304 hair samples were analysed in parallel by MALDI-MS and a reference gas chromatography-MS method. The obtained results demonstrate specificity and sensitivity of 100% for MALDI-MS. Evidence of cocaine presence was easily obtained even when hair samples exhibiting particularly low cocaine levels (<0.5 ng/mg) were analysed.  相似文献   

16.

Background

Considerable efforts are being extended to develop more effective methods to detect drugs in forensic science for applications such as preventing doping in sport. The aim of this study was to develop a sensitive and accurate method for analytes of forensic and toxicological nature in human hair at sub-pg levels.

Results

The hair test covers a range of different classes of drugs and metabolites of forensic and toxicological nature including selected anabolic steroids, cocaine, amphetamines, cannabinoids, opiates, bronchodilators, phencyclidine and ketamine. For extraction purposes, the hair samples were decontaminated using dichloromethane, ground and treated with 1 M sodium hydroxide and neutralised with hydrochloric acid and phosphate buffer and the homogenate was later extracted with hexane using liquid-liquid extraction (LLE). Following extraction from hair samples, drug-screening employed liquid chromatography coupled to tandem mass spectrometric (LC-MS/MS) analysis using dynamic multiple reaction monitoring (DYN-MRM) method using proprietary software. The screening method (for?>?200 drugs/metabolites) was calibrated with a tailored drug mixture and was validated for 20 selected drugs for this study. Using standard additions to hair sample extracts, validation was in line with FDA guidance. A Zorbax Eclipse plus C18 (2.1 mm internal diameter × 100 mm length × 1.8 μm particle size) column was used for analysis. Total instrument run time was 8 minutes with no noted matrix interferences. The LOD of compounds ranged between 0.05-0.5 pg/mg of hair. 233 human hair samples were screened using this new method and samples were confirmed positive for 20 different drugs, mainly steroids and drugs of abuse.

Conclusions

This is the first report of the application of this proprietary system to investigate the presence of drugs in human hair samples. The method is selective, sensitive and robust for the screening and confirmation of multiple drugs in a single analysis and has potential as a very useful tool for the analysis of large array of controlled substances and drugs of abuse.
  相似文献   

17.
Two new standard reference materials (SRM) for drugs of abuse in human hair have been developed. SRM 2379 consists of hair spiked with cocaine, benzoylecgonine, cocaethylene, phencyclidine, amphetamine, and methamphetamine. SRM 2380 consists of hair spiked with codeine, morphine, monoacetylmorphine, and tetrahydrocannabinol (THC). The SRMs were prepared by soaking the hair in a solution of the target analytes in water-dimethylsulfoxide. The concentration of each analyte was determined using two methods, one based upon gas chromatography/mass spectrometry (GC/MS) and one based upon liquid chromatography/mass spectrometry (LC/MS). Both methods used 0.1 M HCl for extraction of all the analytes from the hair, except for THC, which was extracted with 1 M NaOH. For isolation of the analytes from the extracts, the GC/MS-based methods used different clean-up procedures from those used for the LC/MS-based methods. The results from the two methods were in good agreement with mean differences for the analytes ranging from 4% to 16%. These materials will enable laboratories performing analyses of hair for drugs of abuse to test the accuracy of their methods.  相似文献   

18.
In order to reduce time of analysis, a new pressurized liquid extraction (PLE) method that automatically and rapidly achieves quantitative and selective extraction of 39 polybrominated diphenyl ether (PBDE) congeners in sediment samples was optimized. It consists of on-line cleanup by inclusion of sorbents in the extraction cell. The new method was compared with a conventional method based on the use of Soxhlet extraction followed by solid-phase extraction (SPE) with cartridges. The instrumental determination was performed by GC-MS, using negative chemical ionization in the selected-ion monitoring mode. Recoveries from 47 to 82% were obtained for spiked tri- to hepta-PBDE congeners in sediment sample. The repeatability of replicate extractions was better than 15% relative standard deviation. The detection limits obtained with the new developed method were between 1 and 46 pg/g dry weight. The reduction in the sample preparation (extraction + cleanup) time (from days to 30 min) with a similar efficiency than that afforded by the conventional Soxhlet extraction-SPE cleanup technique indicates the suitability of this method. The method was applied to sediment samples where the analytes were detected in the range of 0.86-2.49 ng/g dry mass.  相似文献   

19.
Detection of testosterone,nandrolone and precursors in horse hair   总被引:1,自引:0,他引:1  
Growing interest among several horse-breeder associations has initiated the development of a screening procedure to test for anabolic agents in hair, which has the advantage over blood and urine specimens of allowing long-term detection. An analytical method was established to monitor in tails or manes several anabolic substances available as veterinary medicines or as so-called nutritional supplements (clenbuterol, different esters or prohormones of nandrolone and testosterone). The analytical procedure to detect steroids in hair samples consists of the following steps: decontamination of the hair strand or segment with methanol/water (1:1), milling, extraction of the hair material in an ultrasonic bath using methanol, purification by liquid–liquid extraction (n-pentane/methanol, 25:1) and HPLC cleanup, derivatisation of the relevant LC fractions with MSTFA, and measurement using GC-MS/MS technique. The first objective of our study was the detection of exogenous nandrolone (nortestosterone, NT) in the horse hair; therefore nandrolone-associated compounds [nandrolone dodecanoate administered intramuscularly (i.m.) and a mixture of 4-estrenediol and 4-estrenedione, transdermal] were administered to four geldings. The highest concentrations of NT following i.m. treatment were measured after 10 days in a 2-cm hair segment (up to 18 pg/mg); NT was detectable for up to 120 days and in some cases up to 330 days in tail hair (limit of detection 0.3 pg/mg). Following transdermal application, nandrolone as well as the administered prohormones were identified in tail and mane until the latest sampling at 3 months. Furthermore, untreated stallions (128) were investigated to estimate the range of endogenous levels of NT and testosterone (T) in hair. Maximum values of 3 pg/mg (NT) and 1 pg/mg (T) were quantified originating from endogenous formation in the male horse. Additionally, a possible relationship between steroid concentrations in hair specimens and the age of stallions was appraised. NT and T were not detected in hair samples of control geldings. Following nandrolone treatment of geldings, highest values in hair exceeded the endogenous amount detected in untreated stallions. Therefore comparison of concentrations measured in control samples with the estimated endogenous levels could give a clue to exogenous application in cases of abnormally high amounts of NT or T. The possibility of the evaluation of threshold values is discussed as a means to verify an exogenous administration of NT and T in hair samples. Furthermore, the detection of a synthetic substance in hair, e. g. the parent steroid ester by itself, would be unequivocal proof of an exogenous origin of NT or T and the previous medication of the stallion.  相似文献   

20.
A simple procedure has been developed and validated for the qualitative and quantitative analysis of several opiates (morphine, 6-acetylmorphine, codeine, 6-acetylcodeine) and tramadol in hair. The analytes were extracted from within the matrix via an overnight incubation with methanol at 65 °C, and afterwards the samples were cleaned up by mixed-mode solid-phase extraction. The extracts were derivatized with N-methyl-N-(trimethylsilyl) trifluoroacetamide with 5% trimethylchlorosilane and analyzed by gas chromatography–mass spectrometry in the selected ion monitoring mode. The method was linear from 0.05 (lower limit of quantitation) to 50 ng/mg (40 ng/mg for tramadol), with correlation coefficients higher than 0.99 for all compounds, accomplishing the cut-off values proposed by the Society of Hair Testing for the detection of these substances in hair (0.2 ng/mg). Intra- and interday precision and trueness were in conformity with the criteria normally accepted in bioanalytical method validation, and the sample cleanup step presented a mean efficiency higher than 90% for all analytes. Furthermore, using these incubation conditions, 6-acetylmorphine did not significantly hydrolyze to morphine. For these reasons, and because of its simplicity, the proposed method can be successfully applied in the determination of these compounds in hair samples, and is suitable for application in routine analysis with forensic purposes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号