首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
肖红  杨竟  张石宁  张心保 《色谱》1999,17(4):395-396
建立了测定人血浆中利培酮及其活性代谢物9-羟利培酮质量浓度的反相高效液相色谱方法。用Zor-baxODSC18色谱柱,以V(甲醇):V(水):V(1mol/L醋酸铵):V(3mol/L氨水)=300:50:3:1为流动相,检测波长为280nm,流速为0.8mL/min。利培酮的线性范围为2~600μg/L(r=0.996),回收率为(98.2±3.5)%,日内与日间的标准偏差分别为4.12%和4.83%;9-羟利培酮的线性范围为2~800μg/L(r=0.998),回收率为(97.8±3.8)%,日内与日间的标准偏差分别为4.28%和4.81%。  相似文献   

2.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of risperidone (RSP) and its active metabolite 9-hydroxyrisperidone (9-OH-RSP) in human plasma. The analytes were extracted from human plasma by using the protein precipitation extraction technique. Methyl risperidone was used as internal standard for RSP and 9-OH-RSP. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 411.28 --> 191.15 for RSP and m/z 427.30 --> 207.10 for 9-OH-RSP. The method involves a simple extraction, isocratic chromatography conditions and mass spectrometric detection that enable detection at sub-nanogram levels. The proposed method has been validated with a linear range of 0.10-15.0 ng/mL for RSP and 9-OH-RSP. The intrarun and interrun precision and accuracy values were within 15%. The overall recoveries for RSP and 9-OH-RSP were 82.1% and 83.2%, respectively. The total analysis time was as low as 3.0 min only. The developed method was applied for the determination of the pharmacokinetic parameters of RSP and 9-OH-RSP following a single oral administration of a 1 mg RSP tablet in 24 healthy male volunteers.  相似文献   

3.
Zhang  Xianhua  Zhao  Xia  Zhang  Chao  Yang  Li  Xiong  Xin  Zhou  Yong  Yang  Yiheng  Duan  Jingli 《Chromatographia》2010,71(11):1015-1023

A sensitive and specific LC–MS-MS method is described for the simultaneous quantification of risperidone and 9-hydroxyrisperidone in human plasma. After extraction with tert-butyl methyl ether, plasma samples were separated on an Atlantis HILIC Silica C18 column (4.6 × 150 mm, 5 μm)with a mobile phase of ammonium formate buffer (10 mM, pH 4.0)/acetonitrile (40/60, v/v). Detection was by MS-MS. The method was fully validated according to the accuracy profile theory. It is based on β-expectation tolerance interval for the total measurement error which includes trueness and intermediate precision. The measurement uncertainty derived from β-expectation tolerance interval was estimated at each of the validation standards. The linearity fitted well over the range of 0.11–26.75 ng mL−1 for risperidone with an LLOQ of 0.11 ng mL−1, and for 9-hydroxyrisperidone, at a range of 0.15–37.8 ng mL−1 with an LLOQ of 0.15 ng mL−1. The intra- and inter-batch precision of risperidone were <5.71 and 8.22%, respectively. For 9-hydroxyrisperidone, the data were 5.78 and 6.48%. The recoveries were 88.78% (risperidone) and 70.35% (9-hydroxyrisperidone). The developed method was applied to a pharmacokinetic study of risperidone.

  相似文献   

4.
A sensitive and specific LC–MS-MS method is described for the simultaneous quantification of risperidone and 9-hydroxyrisperidone in human plasma. After extraction with tert-butyl methyl ether, plasma samples were separated on an Atlantis HILIC Silica C18 column (4.6 × 150 mm, 5 μm)with a mobile phase of ammonium formate buffer (10 mM, pH 4.0)/acetonitrile (40/60, v/v). Detection was by MS-MS. The method was fully validated according to the accuracy profile theory. It is based on β-expectation tolerance interval for the total measurement error which includes trueness and intermediate precision. The measurement uncertainty derived from β-expectation tolerance interval was estimated at each of the validation standards. The linearity fitted well over the range of 0.11–26.75 ng mL?1 for risperidone with an LLOQ of 0.11 ng mL?1, and for 9-hydroxyrisperidone, at a range of 0.15–37.8 ng mL?1 with an LLOQ of 0.15 ng mL?1. The intra- and inter-batch precision of risperidone were <5.71 and 8.22%, respectively. For 9-hydroxyrisperidone, the data were 5.78 and 6.48%. The recoveries were 88.78% (risperidone) and 70.35% (9-hydroxyrisperidone). The developed method was applied to a pharmacokinetic study of risperidone.  相似文献   

5.
A new, rapid analytical method, based on liquid chromatography with diode array detection, has been developed and applied to the determination of risperidone and its main active metabolite 9-hydroxyrisperidone in human plasma. The chromatographic separation was obtained on a C8 (150 x 4.6 mm, 5 microm) column, using a mobile phase composed of acetonitrile (27%) and a pH 3.0 phosphate buffer (73%). A sample clean-up procedure was carried out by using C8 cartridges and eluting the analytes with methanol. The extraction yield was highly satisfactory for both analytes, with average absolute recovery values of about 95%. The experimental conditions permitted the quantitative determination of risperidone and 9-hydroxyrisperidone with high precision (RSD < 3.6%) and satisfactory sensitivity (LOQ = 4 ng mL(-1)). The method was applied to plasma samples from a patient who had tried to poison himself with 150 mg of risperidone, and was undergoing polypharmacy.  相似文献   

6.
A simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated for simultaneous quantification of olanzapine, clozapine, ziprasidone, haloperidol, risperidone, and its active metabolite 9-hydroxyrisperidone, in rat plasma using midazolam as internal standard (IS). The analytes were extracted from rat plasma using a single step liquid-liquid extraction technique. The compounds were separated on a Waters Atlantis dC-18 (30 mm x 2.1 mm i.d., 3 microm) column using a mobile phase of acetonitrile/5 mM ammonium formate (pH 6.1 adjusted with formic acid) with gradient elution. All of the analytes were detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. LLOQ was 0.1 ng/mL and correlation coefficient (R(2)) values for the linear range of 0.1-100 ng/mL were 0.997 or greater for all the analytes. The intra-day and inter-day precision and accuracy were better than 8.05%. The relative and absolute recovery was above 77% and matrix effects were low for all the analytes except for ziprasidone. This validated method has been successfully used to quantify the plasma concentration of the analytes after chronic treatment with antipsychotic drugs.  相似文献   

7.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of the new antipsychotic risperidone and its major metabolite 9-hydroxyrisperidone in plasma, urine and animal tissues. The alkalinized plasma samples were extracted with ethyl acetate and further purified prior to reversed-phase chromatography with ultraviolet detection at 280 nm. The method could also be applied to urine samples and animal tissue homogenates. Quantification limits were 2 ng/ml for plasma and urine and 10 ng/g for animal tissue. The method was applied to pharmacokinetic studies in experimental animals, human volunteers and patients.  相似文献   

8.
A simple, specific and sensitive high performance liquid chromatography-mass spectrometry (LC-MS) method for the determination of risperidone and its active metabolite 9-hydroxyrisperidone in human plasma has been developed and validated. The analytes were prepared through a single-step liquid-liquid extraction (LLE) procedure with the solvent methyl tert-butyl ether and quantitated by MS detection in the positive mode using selected ion monitoring (SIM). Each analytical run was completed within 9 min. Results showed that the LC-MS method enabled to detection of both compounds down to 0.1 ng.mL–1 (S/N > 3) and the linear range was 0.2–24 ng.mL–1, with the correlation coefficients above 0.99. At the concentration of 0.2, 0.5, 10 and 20 ng.mL–1, the inter-day and intra-day RSD were both below 15%. The method has been successfully used to support the routine therapeutic drug monitoring (TDM) and the pharmacokinetics study of risperidone.  相似文献   

9.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of classical neuroleptics (chlorpromazine, haloperidol, loxapine and clotiapine), atypical antipsychotics (clozapine, quetiapine and risperidone) and their active metabolites (N-desmethylclozapine, clozapine N-oxide and 9-hydroxyrisperidone) in human plasma. Separation was obtained by using a C8 reversed-phase column and a mobile phase composed of 70% aqueous phosphate buffer containing triethylamine at pH 3.0 and 30% acetonitrile. The UV detector was set at 238 nm and amitriptyline was used as the internal standard. A careful pre-treatment procedure of plasma samples was developed, using solid-phase extraction with cyanopropyl cartridges, which gives high extraction yields (>or=93%). The limits of quantitation (LOQ) were always lower than 2.6 ng mL-1 and the limits of detection (LOD) were always lower than 0.9 ng mL-1 for all analytes. The method was applied with success to plasma samples from schizophrenic patients undergoing polypharmacy with two or more different antipsychotics. Precision data and accuracy results were satisfactory and no interference from other central nervous system (CNS) drugs was found. Hence the method is suitable for the therapeutic drug monitoring (TDM) of the analytes in psychotic patients' plasma.  相似文献   

10.
The development and validation of an assay for the determination of paclitaxel in human plasma, human brain tumor tissue, mouse plasma and mouse brain tumor tissue is described. Paclitaxel was extracted from the matrices using liquid-liquid extraction with tert-butyl methyl ether, followed by chromatographic analysis using an alkaline eluent. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicate that calibration standards in human plasma can be used to quantify paclitaxel in all tested matrices. In human samples, the validated range for paclitaxel was from 0.25-1000 ng ml(-1) using 200 microl plasma aliquots and from 5 to 5000 ng g(-1) using 50 microl tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma). In mice, the ranges were 1-1000 ng ml(-1) and 5-5000 ng g(-1) using 50 microl of mouse plasma and 50 microl of tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma), respectively. The method can be applied to studies generating only small sample volumes (e.g. mouse plasma and tumor tissue), but also to studies in human plasma requiring a lower limit of quantitation. The assay was applied successfully to several studies with both human and mouse samples.  相似文献   

11.
The present work describes for the first time the use of SPME coupled to LC–MS/MS employing the polar organic mode in a stereoselective fungal biotransformation study to investigate the fungi ability to biotransform the drug risperidone into its chiral and active metabolite 9-hydroxyrisperidone (9-RispOH). The chromatographic separation was performed on a Chiralcel OJ-H column using methanol:ethanol (50:50, v/v) plus 0.2% triethylamine as the mobile phase at a flow rate of 0.8 mL min−1. The SPME process was performed using a C18 fiber, 30 min of extraction time and 5 min of desorption time in the mobile phase. The method was completely validated and all parameters were in agreement with the literature recommendations. The Cunninghamella echinulata fungus was able to biotransform risperidone into the active metabolite, (+)-9-RispOH, resulting in 100% of enantiomeric excess. The Cunninghamella elegans fungus was also able to stereoselectively biotransform risperidone into (+)- and (−)-9-RispOH enantiomers at different rates.  相似文献   

12.
An automated high performance liquid chromatography with column-switching and ultraviolet detection was developed for the analysis of risperidone and 9-hydroxyrisperidone. The method needs minimum sample preparation and is useful for the detection down to a limit of 1 ng mL−1. Sample clean-up of serum was carried out on a CN 20 μm SPE-column using 8% (v/v) acetonitrile in water. Chromatographic separation was performed on ODS Hypersil C18 material with 38% (v/v) acetonitrile and 0.4% (v/v) TEMED in water. Application of the method to the analysis of serum samples confirmed its suitability for therapeutic drug monitoring of risperidone and 9-hydroxyrisperidone.  相似文献   

13.
A gas chromatography method with mass spectrometric detection is described for the determination of Salvinorin A, the main active ingredient of the hallucinogenic mint Salvia divinorum. The method was validated in plasma, urine, saliva and sweat using 17-alpha-methyltestosterone as internal standard. The analytes were extracted from biological matrices with chloroform/isopropanol (9:1, v/v). Chromatography was performed on a 5% phenyl methyl silicone capillary column and analytes were determined in the selected ion monitoring mode. The method was validated over the concentration range 0.015-5 microg/mL plasma, urine and saliva and 0.01-5 microg/patch in the case of sweat. Mean recoveries ranged between 77.1 and 92.7% for Salvinorin A in different biological matrices, with precision and accuracy always better than 15%. The method was applied to the analysis of urine, saliva and sweat from two consumers after smoking 75 mg plant leaves to verify the presence of the active ingredient of S. divinorum in human biological fluids as a biomarker of plant consumption. Salvinorin A was detected in urine (2.4 and 10.9 ng/mL) and saliva (11.1 and 25.0 ng/mL), but not in sweat patches from consumers.  相似文献   

14.
A liquid chromatographic/mass spectrometric assay with atmospheric pressure chemical ionization (APCI-LC/MS) is presented for the fast and reliable screening and identification and for the precise and sensitive quantification of 15 neuroleptic (antipsychotic) drugs and three of their relevant metabolites in plasma. It allows confirmation of the diagnosis of a neuroleptic overdose and monitoring of psychiatric patients' compliance. The neuroleptics amisulpride, bromperidol, clozapine, droperidol, flupenthixol, fluphenazine, haloperidol, melperone, olanzapine, perazine, pimozide, risperidone, sulpiride, zotepine and zuclopenthixol and the pharmacologically active metabolites norclozapine, clozapine N-oxide and 9-hydroxyrisperidone were extracted from plasma using solid-phase extraction and were separated on a Merck LiChroCART column with Superspher 60 RP Select B as the stationary phase. Gradient elution was performed using aqueous ammonium formate and acetonitrile. After screening and identification in the scan mode using the authors' new LC/MS library, the neuroleptics were quantified in the selected-ion mode. The quantification assay was fully validated. It was found to be selective and proved to be linear from sub-therapeutic to over therapeutic concentrations for all analytes. The corresponding reference levels are listed. The accuracy and precision data were within the required limits. The analytes were stable in frozen plasma for at least 1 month. The method was successfully applied to several authentic plasma samples from patients treated or intoxicated with various neuroleptics. The validated LC/MS assay has proved to be appropriate for the isolation, separation, screening, identification and quantification of various neuroleptics in plasma for clinical toxicology and therapeutic drug monitoring purposes.  相似文献   

15.
An analytical method for the enantioseparation of the 9-hydroxyrisperidone, main metabolite of the antipsychotic risperidone (Risp), was developed by CD-EKC in the dual CDs mode using anionic and neutral CDs at acidic pH 2.5. Preliminary experiments allowed us to select the more suitable couple of CDs composed of sulfated-alpha-CD and hydroxypropylated-beta-CD. The optimization of the main experimental parameters (concentrations of both CDs and concentration of the phosphate buffer) was based on a central composite design through the response surface methodology. Then, the influence of the voltage and the temperature on the enantioseparation was studied using the classical univariate approach. The final method permits to resolve the enantiomers of the 9-hydroxyrisperidone with a resolution of 3.13 and an analysis time of about 13 min. Finally, this method was successfully applied for the simultaneous determination of Risp and the enantiomers of 9-hydroxyrisperidone (9-OHRisp).  相似文献   

16.
A simple and highly sensitive liquid chromatographic/electrospray tandem mass spectrometric (LC/MS/MS) assay was developed for the simultaneous determination of risperidone (RSP) and its major circulating metabolite 9-hydroxyrisperidone (9-OH-RSP) in the plasma of humans and rats. A simple one-step solvent extraction with 15% methylene chloride in pentane was used to isolate the compounds from plasma. The compounds were eluted from a phenyl-hexyl column and detected with a Perkin-Elmer SCIEX API2000 triple-quadrupole mass spectrometer using positive ion atmospheric pressure electrospray ionization and multiple reaction monitoring. The assay was linear over the range 0.1-100 ng ml(-1) when 0.5 ml of plasma was used in the extraction. The overall intra- (within-day) and inter- (between days) assay variations were < 11%. The variations in the concentrations of two long-term quality control samples from pooled patient plasma samples analyzed over a period of 6 months were approximately 10%. The analysis time for each sample was 4 min and more than 100 samples could be analyzed in one day by running the system overnight. The assay is simple, highly sensitive, selective, precise and fast. This method is being used for the therapeutic drug monitoring of schizophrenic patients treated with RSP and to study the pharmacokinetics and tissue distribution of RSP and 9-OH-RSP in rats.  相似文献   

17.
Knowing that microbial transformations of compounds play vital roles in the preparation of new derivatives with biological activities, risperidone and its chiral metabolites were determined by capillary electrophoresis and hollow fiber liquid-phase microextraction after a fungal biotransformation study in liquid culture medium. The analytes were extracted from 1 mL liquid culture medium into 1-octanol impregnated in the pores of the hollow fiber, and into an acid acceptor solution inside the polypropylene hollow fiber. The electrophoretic separations were carried out in 100 mmol/L sodium phosphate buffer pH 3.0 containing 2.0% w/v sulfated-α-CD and carboxymethyl-β-CD 0.5% w/v with a constant voltage of -10 kV. The method was linear over the concentration range of 100-5000 ng/mL for risperidone and 50-5000 ng/mL for each metabolite enantiomer. Within-day and between-day assay precisions and accuracies for all the analytes were studied at three concentration levels, and the values of relative standard deviation and relative error were lower than 15%. The developed method was applied in a pilot biotransformation study employing risperidone as the substrate and the filamentous fungus Mucor rouxii. This study showed that the filamentous fungus was able to metabolize risperidone enantioselectively into its chiral active metabolite, (-)-9-hydroxyrisperidone.  相似文献   

18.
A simple high performance liquid chromatography techniques with ultraviolet detection (HPLC–UV) method is described for the simultaneous determination of clozapine (CZP), clozapine N-oxide (CNO), N-desmethylclozapine (NCZ), risperidone (RSP) and 9-hydroxyrisperidone (9-OHRSP) in human plasma. After extraction process, the analytes were separated on a C18 column (150 mm×3.9 mm i.d.) by the mobile phase (methanol–water–dimethylamine, 60:40:0.04 (v:v:v)). Relative recoveries of five analytes were quantitative. The precision and accuracy of intra- and interday assays were all below 8.2% for R.S.D. and 5.6% for RE, respectively. Based on 1 ml of plasma, the limits of detection were 2.0 ng/ml for CZP, 0.2 ng/ml for CZP N-oxide, 1.0 ng/ml for NCZ, 1.0 ng/ml for RSP, and 0.5 ng/ml for 9-OHRSP (S/N=3). The calibration curves were linear (r≥0.988). This method was applied to therapeutic drug monitoring of schizophrenia patients receiving CZP or RSP therapy.  相似文献   

19.
A simple and sensitive ultra‐performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of olanzapine (OLZ), risperidone (RIS) and 9‐hydroxyrisperidone (9‐OHRIS) in human plasma in vitro. The sample preparation was performed by simple liquid–liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP18 column maintained at 40°C. Quantification was performed on a photodiode array detector set at 277 nm and clozapine was used as internal standard (IS). OLZ, RIS, 9‐OHRIS and IS retention times were found to be 0.9, 1.4, .1.8 and 3.1 min, respectively, and the total run time was 4 min. The method was validated for selectivity, specificity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 1–100 ng/mL for OLZ, RIS and 9‐OHRIS. Intra‐ and inter‐day precisions for OLZ, RIS and 9‐OHRIS were found to be good with the coefficient of variation <6.96%, and the accuracy ranging from 97.55 to 105.41%, in human plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of RIS and 9‐OHRIS in human plasma. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
This paper reviews procedures for quantification of drugs in the biosamples blood, plasma, serum, or oral fluid (saliva, etc.) using liquid chromatography coupled with single-stage or tandem mass spectrometry (LC–MS, LC–MS–MS). Such procedures are important prerequisites for competent toxicological judgment and consultation in clinical and forensic toxicology. They cover blood (plasma, serum) analysis of amphetamines and related designer drugs, anesthetics, anticonvulsants, benzodiazepines, opioids, serotonergic drugs, tricyclic antidepressants, neuroleptics, antihistamines, beta-blockers, muscle relaxants, and sulfonylurea-type antidiabetics, and oral fluid analysis of amphetamines and related designer drugs, cocaine, benzoylecgonine, codeine, morphine, enantiomers of methadone and its main metabolite 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), the nicotine metabolites cotinine and hydroxycotinine, and finally risperidone and its metabolite 9-hydroxyrisperidone. Basic information on the procedures is given in two tables and an example of quantification is illustrated in two figures. The pros and cons of such LC–MS procedures including sample work-up and ion suppression effects are critically discussed.  相似文献   