相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe high-speed Fourier domain optical coherence tomography (OCT) using optical demultiplexers (ODs) for spectral dispersion. The OD enables separation of a narrow spectral band of 14 GHz (0.11 nm) from a broadband incident light at 256 different frequencies in 25.0 GHz intervals centered at 192.2 THz (1559.8 nm). OCT imaging of 60,000,000 axial scans per second was achieved through parallel signal acquisition using 256 balanced photoreceivers to simultaneously detect all the output signals from the ODs in a Fourier domain OCT system. OCT imaging at a 16 kHz frame rate, 1100 A-lines per frame, 3 mm depth range, and 23 microm resolution was demonstrated using a resonant scanner for lateral scanning.  相似文献   

2.
Hu Z  Rollins AM 《Optics letters》2007,32(24):3525-3527
We describe Fourier domain optical coherence tomography equipped with a novel linear-in-wavenumber spectrometer. The presented device linearizes the spectral dispersion of the spectrometer in wavenumber using a specifically designed prism. The spectral linearity in wavenumber makes numerical interpolation into wavenumber unnecessary, reduces computing time, and furthermore results in improvement of the falloff of signal with image range inherent to frequency-domain optical coherence tomography imaging. Experiments demonstrate the improvement of the falloff and agree with the expected results from simulation.  相似文献   

3.
Chao Ding  Peng Bu  Xiangzhao Wang  Osami Sasaki 《Optik》2010,121(11):965-24343
Spectral calibration is important for a Fourier domain optical coherence tomography (FD-OCT) system. A new spectral calibration method for FD-OCT is presented. Through the iterated mapping of spectral interferograms detected by an optical spectrum analyzer and the CCD grating spectrometer, multiple groups of calibration coefficients are obtained. By comparing the effects of these coefficients on improving the amplitude of the axial point spread function (PSF), optimum coefficients are obtained. In this method, no additional calibration laser source is needed, reducing the complexity of the system. The cross-sectional images of a glass plate in milk are acquired, and the experimental results indicate that the axial resolution and signal-to-noise ratio (SNR) are effectively improved with the proposed spectral calibration method.  相似文献   

4.
Zhang J  Jing J  Wang P  Chen Z 《Optics letters》2011,36(24):4788-4790
A polarization-maintaining buffered Fourier domain mode-locked (FDML) swept source with a center wavelength of 1300 nm is demonstrated. The scanning rate of the buffered FDML swept source is doubled without sacrificing the output power of the swept source by combining two orthogonally polarized outputs with a polarization beam combiner. The stability of the swept source is improved because the polarization state of the laser beam inside the laser cavity is maintained without the use of any polarization controllers. The swept source is capable of an edge-to-edge tuning range of more than 150 nm and a FWHM range of 95 nm at a 102 kHz sweeping rate and with an average power of 12 mW. A swept source optical coherence tomography (SSOCT) system is developed utilizing this buffered FDML swept source. The axial resolution of the SSOCT system is measured to be 9.4 μm in air. The sensitivity of the SSOCT system is 107.5 dB at a depth of 0.25 mm with a 6 dB roll-off at a depth of 2.25 mm.  相似文献   

5.
We introduce a simple and cheap method for phase-shifting Fourier domain optical coherence tomography (FDOCT) that does not need additional devices and can easily be implemented. A small beam offset at the fast beam-scanning mirror introduces a causal phase shift, which can be used for B-scan-based complex image reconstruction. We derive the conditions for optimal conjugate suppression and demonstrate the method on human skin in vivo for spectrometer-based FDOCT operating at 1300 nm employing a handheld scanner.  相似文献   

6.
A nonreciprocal fiber-optic interferometer is demonstrated in an optical coherence tomography (OCT) system. The increased power efficiency of this system provides a 4.1-dB advantage over standard Michelson implementations. In addition, a new linear-scanning fiber-optic catheter is demonstrated that avoids the rotary optical junction that is required in circumferential scanning systems. These advancements have permitted the clinical implementation of OCT imaging in the human gastrointestinal tract.  相似文献   

7.
We present a novel algorithm for full-range imaging by suppression of the complex conjugate artifact in phase-shifting Fourier domain optical coherence tomography. This technique utilizes the projection of multiple phase-shifted interferograms onto an orthogonal basis set to reconstruct the complex interferogram. Full-range imaging with >30 dB suppression of the symmetric artifact is demonstrated using a 3 x 3 fiber coupler swept source OCT system, providing a depth range of 6.6mm with -8 dB roll-off in sensitivity at the depth boundaries relative to DC. Real-time display of full-range images of the anterior segment of the human eye acquired in vivo at a line rate of 6.67 kHz are presented.  相似文献   

8.
We report on a new detection scheme for Fourier domain optical coherence microscopy that exhibits high transverse resolution along an axially extended focal range. Nearly constant transverse resolution of approximately 1.5 microm along a focal range of 200 microm is experimentally verified with a maximum sensitivity of 105 dB. A broad-bandwidth Ti:sapphire laser allowed for an axial resolution of 3 microm in air.  相似文献   

9.
Tsai  M. -T.  Chang  F. -Y. 《Laser Physics》2012,22(4):791-796
In this study, a swept-source optical coherence tomography (SS-OCT) system with a Fourier domain mode locking (FDML) laser is proposed for a dermatology study. The homemade FDML laser is one kind of frequency-sweeping light source, which can provide output power of >20 mW and an output spectrum of 65 nm in bandwidth centered at 1300 nm, enabling imaging with an axial resolution of 12 μm in the OCT system. To eliminate the forward scans from the laser output and insert the delayed backward scans, a Mach-Zehnder configuration is implemented. Compared with conventional frequency-sweeping light sources, the FDML laser can achieve much higher scan rates, as high as ∼240 kHz, which can provide a three-dimensional imaging rate of 4 volumes/s. Furthermore, the proposed high-speed SS-OCT system can provide three-dimensional (3D) images with reduced motion artifacts. Finally, a high-speed SS-OCT system is used to visualize hair follicles, demonstrating the potential of this technology as a tool for noninvasive diagnosis of alopecia.  相似文献   

10.
Buffered Fourier domain mode-locked (FDML) lasers are demonstrated for dynamic phase-sensitive optical coherence tomography (OCT) and 3D OCT phase microscopy. Systems are operated at sweep speeds of 42, 117, and 370 kHz, and displacement sensitivities of 39, 52, and 102 pm are achieved, respectively. Sensitivities are comparable to spectrometer-based OCT phase microscopy systems, but much faster acquisition speeds are possible. An additional factor of sqrt 2 improvement in noise performance is observed for differential phase measurements, which is important for Doppler OCT. Dynamic measurements of piezoelectric transducer motion and static 3D OCT phase microscopy are demonstrated. Buffered FDML lasers provide excellent displacement sensitivities at extremely high sweep speeds.  相似文献   

11.
A novel spectral calibration method is developed for spectral domain optical coherence tomography system. The method is based on two measurements of interference spectra from two reference mirror positions. It removes the influence of dispersion mismatch, and hence accurately determines the spectral distribution on the line-scan charge-coupled device (CCD) for sequent precise interpolation. High quality imaging can be realized with this method. Elimination of the degradation effect caused by dispersion mismatch is verified experimentally, and improved two-dimensional (2D) imaging of fresh orange pulp based on the proposed spectral calibration method is demonstrated.  相似文献   

12.
We have demonstrated an efficient scheme of automatically removing fixed pattern noise in Fourier domain optical coherence tomography by using a periodic reference spectrum subtraction method. By periodically acquiring the reference spectra using a separate light absorber placed to the right of the scan lens, we were able to adaptively compensate the background fixed pattern due to the spectral intensity variation of the source. The adaptive removal of fixed pattern noise was effectively performed by controlling the reference spectrum acquisition rate (R). A seawater pearl was used for a test sample under an intentional abrupt source power change to validate the proposed method. Based on this method, it is possible to perform immediate cold start scanning because it is not necessary for a stabilization period of the light source, as well as a manual process of reference spectrum acquisition for obtaining clear image under unstable environment.  相似文献   

13.
An ultra-high resolution spectral domain optical coherence tomography (SD-OCT) was developed using a cost-effective supercontinuum laser. A spectral filter consists of a dispersive prism, a cylindrical lens and a right-angle prism was built to transmit the wavelengths in range 680–940 nm to the OCT system. The SD-OCT has achieved 1.9 μm axial resolution and the sensitivity was estimated to be 91.5 dB. A zero-crossing fringes matching method which maps the wavelengths to the pixel indices of the spectrometer was proposed for the OCT spectral calibration. A double sided foam tape as a static sample and the tip of a middle finger as a biological sample were measured by the OCT. The adhesive and the internal structure of the foam of the tape were successfully visualized in three dimensions. Sweat ducts was clearly observed in the OCT images at very high resolution. To the best of our knowledge, this is the first demonstration of ultra-high resolution visualization of sweat duct by OCT.  相似文献   

14.
王毅  郭哲  朱立达  周红仙  马振鹤 《物理学报》2017,66(15):154202-154202
提出了一种基于谱域相位分辨光学相干层析的纳米级表面形貌成像方法,由干涉光谱计算样品相邻两点的相位差,得到样品表面相位差分图,经过积分,重建样品表面形貌的定量分布.当相邻两点相位差的绝对值小于π,不产生相位包裹,避免了目前的干涉法相位解包裹存在的问题,将干涉法相邻两点相位差绝对值的限制条件由目前的π扩大到2π,提高了干涉法表面形貌成像的适用范围.参考面和样品置于同一平台之上,消除环境干扰及系统振动的影响,噪声幅度小于0.3 nm.通过对光学分辨率片及表面粗糙度标准样板的表面形貌成像,对本方法进行了验证,系统的轴向分辨率优于1 nm.  相似文献   

15.
Tao YK  Ehlers JP  Toth CA  Izatt JA 《Optics letters》2010,35(20):3315-3317
We demonstrate in vivo human retinal imaging using an intraoperative microscope-mounted optical coherence tomography system (MMOCT). Our optomechanical design adapts an Oculus Binocular Indirect Ophthalmo Microscope (BIOM3), suspended from a Leica ophthalmic surgical microscope, with spectral domain optical coherence tomography (SD-OCT) scanning and relay optics. The MMOCT enables wide-field noncontact real-time cross-sectional imaging of retinal structure, allowing for SD-OCT augmented intrasurgical microscopy for intraocular visualization. We experimentally quantify the axial and lateral resolution of the MMOCT and demonstrate fundus imaging at a 20Hz frame rate.  相似文献   

16.
We propose an approach for absolute velocity measurement where the use of a beam displacer provides two orthogonal linearly polarized beams to probe the sample simultaneously at two different incidence angles. The approach helps remove the cross talk image and facilitates single detector-based Fourier domain Doppler velocity measurement. The system has been characterized by quantifying absolute flow velocity in a flow phantom.  相似文献   

17.
Payne A  Podoleanu AG 《Optics letters》2012,37(12):2424-2426
An electronic method of k-space linearization for an analog camera for use in optical coherence tomography is demonstrated. The method applies a chirp to the data transfer clock signal of the camera in order to temporally compensate for diffraction that is nonlinear in wavenumber. The optimum parameters are obtained experimentally and theoretically and are shown to be in good accordance. Close to maximum measurable axial range, by applying this method, the FWHM of the point spread function is reduced by a factor of 5.6 and sensitivity is increased by 9.8 dB.  相似文献   

18.
19.
胡喆皓  上官紫微  邱建榕  杨珊珊  鲍文  沈毅  李鹏  丁志华 《物理学报》2018,67(17):174201-174201
鉴于不同生理病理状态下组织复折射率实部的变化不大,传统光学相干层析(OCT)成像技术在分子特异性识别上存在先天不足.为此,本文提出了基于受激辐射信号的OCT成像方法,可在实现传统散射成像的同时,实现基于受激辐射信号的分子成像.在超高分辨率谱域OCT系统的基础上,通过增设光谱分光与调制抽运光支路,建立了基于单宽谱光源的抽运探测谱域OCT系统,详细推导了调制抽运下受激辐射信号的获取与成像公式.利用搭建的抽运探测谱域OCT系统,实现了瞬态受激辐射信号的相干探测.基于同时获取的受激辐射OCT信号和传统OCT信号,成功重构了氮化物粉末构建样品的基于受激辐射信号的分子对比OCT图像.  相似文献   

20.
鲍文  丁志华  王川  梅胜涛 《物理学报》2013,62(11):114202-114202
本文提出一种基于相位敏感谱域光学相干层析术 (spectral domain optical coherence tomography, SD-OCT) 的遗留指纹获取方法, 该方法具有非接触、无损、快速和高灵敏度优势. 实验结果显示, 即使在低对比度条件下, 本方法也能较好地再现遗留指纹, 证明相位敏感谱域光学相干层析术可以准确、可靠地识别潜指纹. 关键词: 潜指纹 谱域光学相干层析术 相位敏感  相似文献   