首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The chamber production and installation of the BESⅢ MUON identifier system have been finished. The cosmic ray test result after installation shows that the average efficiency is bigger than 95% and can meet the requirement of the design report. A database including all the chamber parameters and performance data has been constructed and is accessible online. The quality control procedures during the production and the database are described.  相似文献   

2.
The BESⅢ drift chamber and its subsystems need a cosmic-ray test after the chamber construction to check the chamber construction quality,testing the joint operation of the whole system and the performance of the chamber.The noise performance,drift time and charge measurements,and the scanning of channels were examined specifically.The preliminary results of the test indicate that the whole system works well.  相似文献   

3.
北京谱仪(BESⅢ)采用阻性板室(Resistive Plate Chambers)作为其muon探测器, 总使用面积达1200m2. 为保证探测器的质量, 每一块阻性板室都要求通过宇宙线测试. 宇宙线测试系统使用3个流光管室作为其触发和寻迹系统, 其空间分辨可达2—3mm, 覆盖面积约4m2, 测试系统可同时测量8块RPCs. 最后, 还报道了RPC的初次测试结果.  相似文献   

4.
The reconstruction algorithm for BESⅢ Muon Counter, MucRecAlg, is developed with the object-oriented language C++ in BESⅢ offline software environment. MucRecAlg consists of the following functions: to find track seeds either from extrapolation of tracks in the main drift chamber or from the fired strips in muon counter, to select fired strips associated to the candidate tracks, to fit the candidate tracks with a linear or quadratic function and to calculate other parameters of the tracks for muon identification. Monte Carlo samples are generated to check the performance of the reconstruction package, such as reconstruction efficiency, muon remaining rate and pion rejection rate, etc. The preliminary results show that the pion rejection rate is around 3%-4% while the muon remaining rate is better than 90% in 0.4-1.6 GeV/c momentum region, which meets the requirement as shown in the design report.  相似文献   

5.
A method to determine precisely three-dimensional wire positions in the BESⅢ drift chamber using physics events is introduced. In part the proposed technique takes advantage of the possibility that the magnetic field can be turned off, thereby providing a huge sample of straight tracks for which effects due to multiple scattering, energy loss and non-uniformity of the magnetic field are minimized during the calibration process. A toy Monte Carlo study is performed to demonstrate the viability of the method. As a result of the calibration process, the rms of the distribution of wire position deviation is reduced from 35μm to 10μm.  相似文献   

6.
After examination of the designed high voltage power supply system of the BESⅢ drift chamber in the beam test of the full length prototype of drift chamber, a full system covering all the channels of high voltage was installed. The system's training and the high voltage value adjustment were carried out in the cosmic ray test of the BESⅢ drift chamber. The cosmic ray test for the full system and its final installation on the BESⅢ drift chamber were reported. The full system of high voltage power supply works stably and reliably.  相似文献   

7.
Offline calibration plays an important role in BES offline data processing. In order to achieve good spatial and momentum resolution, it is necessary to implement high precision offline calibration for the BES drift chamber. This paper studies the time-to-distance relations, which are important calibration constants for track reconstruction. The parameterization of the time-to-distance relation, studies of left-right asymmetry and studies of variation with entrance angle are performed. The impact of dead channels on the time-to-distance relation is given special attention in order to reduce the shift in measured momentum for tracks passing near dead cells. Finally we present the resolutions for barrel Bhabha events(|cos θ|< 0.8) from a J/ψ data set taken in 2012. The average spatial resolution is 123 μm and the momentum resolution for 1.548 Ge V/c Bhabha tracks is 11.9 Me V/c.  相似文献   

8.
Based on real data,a new parameterized model of the main drift chamber response is proposed.In this model,we tune the ratio of good hits and the residual distribution separately.By data quality checking,the diference between simulation and data in track reconstruction efciency reduces from 1%to 0.5%averagely for the pion in J/ψ→π+ππ0,and the momentum resolution agreement improves significantly for the proton in J/ψ→ppˉ.  相似文献   

9.
The BESⅢ detector has a high-resolution electromagnetic calorimeter which can be used for low momentum μ-π identification.Based on Monte Carlo simulations, μ-π separation was studied.A multilayer perceptron neural network making use of the defined variables was used to do the identification and a good μ-π separation result was obtained.  相似文献   

10.
A method to estimate the efficiency of event start time determination at BESIII is developed.This method estimates the efficiency at the event level by combining the efficiencies of various tracks(e,μ,π,K,p,γ)in a Bayesian way.Efficiencies results and the difference between data and MC at the track level are presented in this paper.For a given physics channel,event start time efficiency and systematic error can be estimated following this method.  相似文献   

11.
The CsI(Tl) crystal modules of the Beijing Spectrometer Ⅲ (BESⅢ) electro-magnetic calorimeter (EMC) were designed and assembled through Monte Carlo simulation and experiments. After the assembly was finished, the performance of each crystal module was tested by cosmic rays. All crystal modules were found to work well before the installation of EMC.  相似文献   

12.
In this paper,the kinematic fitting with the Lagrange multiplier method has been studied for BESⅢ experiment.First we introduce the Lagrange multiplier method and implement kinematic constraints.Then we present the performance of the kinematic fitting algorithm.With the kinematic fitting,we can improve the resolution of track parameters and reduce the background.  相似文献   

13.
使用800MeV的电子束对BESⅢ端盖飞行时间探测器(TOF)模块的性能进行测试. 研究了塑料闪烁体的包装材料、光电倍增管(PMT)的工作电压、电子束入射位置对单个TOF模块的本征时间分辨的影响,并给出了测量时间与信号幅度和粒子击中位置的修正方法. 实验结果显示:使用Tyvek纸包装,闪烁体在安装PMT的一端有45°斜面, 电子击中在TOF模块不同位置其本征时间分辨在70—90ps范围内.  相似文献   

14.
Software alignment is quite important for a tracking detector to reach its ultimate position accuracy and momentum resolution. We developed a new alignment algorithm for the BESⅢ Main Drift Chamber using the Kalman Filter method. Two different types of data which are helix tracks and straight tracks are used to test this algorithm, and the results show that the design and implementation is successful.  相似文献   

15.
Data quality monitoring (DQM) plays an important role in data taking at the BESⅢ experiments. DQM is used to monitor detector status and data quality. A DQM framework (DQMF) has been developed to make it possible to reuse the BESⅢ offline reconstruction system in the online environment. In this framework, the DQMF can also simulate a virtual data taking environment, transfer events to the event display, publish histograms to a histogram presenter in a fixed interval, and dump histograms into a ROOT file. The DQMF has been stably running throughout BESⅢ data taking.  相似文献   

16.
A prototype multi-gap resistive plate chamber (MRPC) with a 2×6 gap structure is developed for the upgrading of the endcap time-of-flight (ETOF) detector in the Beijing Spectrometer (BESⅢ). The prototype MRPC is tested in the E3 beam line of the Beijing Electron Positron Collider (BEPC) with secondary charged particles (π and p, etc) of 600 MeV/c. The test results show that the time resolution of the MRPC can reach 50 ps and that the detection efficiency is greater than 98%.  相似文献   

17.
The BESⅢ detector has a high-resolution electromagnetic calorimeter which can be used for low momentum μ-π identification. Based on Monte Carlo simulations, μ-π separation was studied. A multilayer perceptron neural network making use of the defined variables was used to do the identification and a good μ-π separation result was obtained.  相似文献   

18.
李海波  朱世海 《中国物理 C》2012,36(10):932-940
Recently, the LHCb experiment announced 3.5σ evidence for direct CP violation in D0 decay by looking at the difference between ACP(D0→K+K-) and ACP(D0→π+π-). This is the rst evidence of CP violation in a charm system, which may indicate new physics beyond the Standard Model. Motivated by this measurement, we review rare processes in charmonium decay, especially, the weak decay, C or P violated decay, and lepton avor violated decays. In case the new physics appears in charm sector, these rare decays of charmonium states will provide an opportunity to search for signi cant contributions from physics beyond the Standard Model. With huge J/ψ and ψ(2S) samples in BES0 experiment, the rare decays may be feasible.  相似文献   

19.
A GEANT4-based Monte-Carlo (MC) model is developed to study the performance of endcap time-of-flight (ETOF) at BESⅢ. It's found that the multiple scattering effects, mainly from the materials at the MDC endcap, can cause multi-hit on the ETOF's readout cell and significantly influence the timing property of ETOF. A multi-gap resistive plate chamber (MRPC) with a smaller readout cell structure is more suitable for the ETOF detector due to significantly reduced multi-hit rate (per channel), from 71.5% for currently-used scintillator-based ETOF to 21.8% or 16.7% for MRPC-based ETOF, depending on the readout pad size used. The timing performance of an MRPC ETOF is also improved. These simulation results suggest and guide an ETOF upgrade effort at BESⅢ.  相似文献   

20.
The prototype of a time digitizing system for the BESⅢ endcap TOF (ETOF) upgrade is introduced in this paper. The ETOF readout electronics has a distributed architecture. Hit signals from the multi-gap resistive plate chamber (MRPC) are signaled as LVDS by front-end electronics (FEE) and are then sent to the back-end time digitizing system via long shield differential twisted pair cables. The ETOF digitizing system consists of two VME crates, each of which contains modules for time digitization, clock, trigger, fast control, etc. The time digitizing module (TDIG) of this prototype can support up to 72 electrical channels for hit information measurement. The fast control (FCTL) module can operate in barrel or endcap mode. The barrel FCTL fans out fast control signals from the trigger system to the endcap FCTLs, merges data from the endcaps and then transfers to the trigger system. Without modifying the barrel TOF (BTOF) structure, this time digitizing architecture benefits from improved ETOF performance without degrading the BTOF performance. Lab experiments show that the time resolution of this digitizing system can be lower than 20 ps, and the data throughput to the DAQ can be about 92 Mbps. Beam experiments show that the total time resolution can be lower than 45 ps.  相似文献   