首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, a stable electrogenerated chemiluminescence (ECL) detector was developed. The detector was prepared by packing cation-exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)32+ can be compensated by adding a small amount of Ru(bpy)32+ into solution phase. Coupled with high-performance liquid chromatography separation, the detector has been used for determination of itopride hydrochloride in human serum. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of itopride hydrochloride in the range of 1.0 × 10−8 g mL−1 to 1.0 × 10−6 g mL−1 and the detection limit was 3 × 10−9 g mL−1 (S/N = 3). The as-prepared ECL detector displayed good sensitivity and stability.  相似文献   

2.
A new high-performance liquid chromatography method using a coulometric array detector to simultaneously analyse 4-ethylphenol, 4-ethylguaiacol, 4-vinylphenol, and 4-vinylguaiacol in wine was established. This procedure offers important advantages as it does not require sample preparation, with the exception of filtration, and performs chromatographic separation in short time, making control of wine production processes easier. The method is linear up to concentrations of 2000 μg L−1 and precise (R.S.D. < 3%). Limits of detection are low (1-3 μg L−1) and suitable for analytical requirements in the oenological field. When compared to gas-chromatography-flame ionisation detection, the proposed method gives similar results with a shorter execution time.  相似文献   

3.
Zhao J  Chen Z  Li X  Pan J 《Talanta》2011,85(5):2614-2619
A microfluidic chip manufactured from glass substrate and indium tin oxide (ITO) coated glass use for contactless conductivity detection was developed. The detecting electrodes were fabricated by screen-printing and chemical etching methods using an ITO-coated glass wafer. Then, the glass substrate containing separation channels was bonded with the bare side of the processed ITO-coated glass, thus producing an electrophoresis chip integrated with contactless conductivity detector. The prepared microchip displayed considerable stability and reproducibility. Sensitive response was obtained at optimal conditions (including the gap between electrodes, excitation frequency, and excitation voltage). The feasibility of this microfluidic device was examined by detection of inorganic ions, and further demonstrated by the quantification of aminopyrine and caffeine in a compound pharmaceutical. The two ingredients can be completely separated within 1 min. The detection limits were 8 μg mL−1 and 3 μg mL−1, respectively; with the correlation coefficient of 0.996-0.998 in the linear range from 10 μg mL−1 to 800 μg mL−1. The results have showed that the present method is sensitive, reliable and fast.  相似文献   

4.
A new continuous method for the determination of formaldehyde in air is described. A cylindrical wet effluent diffusion denuder is used for the collection of formaldehyde from air into a thin film of absorption liquid (distilled-deionized water). Formaldehyde in the denuder concentrate is on-line detected employing a chemiluminescence flow method based on a reaction of formaldehyde and gallic acid with hydrogen peroxide in an alkaline solution. The collection efficiency of formaldehyde is quantitative at the air flow rate of 0.5 L min−1 (absorption liquid flow rate of 336 μL min−1). The limit of detection (S/N = 3) is 0.60 μg m−3 HCHO (0.49 ppb). The calibration graph is linear up to 300 μg m−3 HCHO (244 ppb). The relative standard deviations of chemiluminescence method for 1 × 10−6 and 5 × 10−6 M HCHO are 2.87% and 1.49%, respectively. Acetaldehyde interferes negligible, other compounds do not interfere. The method was employed for formaldehyde measurement in ambient air. The comparison measurement illustrates the good agreement of results obtained by proposed method with those obtained by reference fluorimetric method.  相似文献   

5.
A compact and robust long-wavelength fluorescence detection system (LWFDS) has been constructed using a pulsed diode laser as the light source and a photodiode detector. The detection limits for naphthofluorescein (NF) and the cyanine dyes Cy5 and Cy5.5 at pH 8.8, determined using the LWFDS, were 1.0×10−10, 2.3×10−12 and 6.2×10−11 M, respectively. These values compared favourably with data from a commercial research grade fluorescence spectrometer. The LWFDS instrument was used as the detector for a competitive heterogeneous flow injection immunoassay for α-interferon with Cy5 as the label. A calibration graph usable over the range 0.5-10 μg ml−1 α-interferon was obtained. The instrument demonstrated its potential for rapid (<200 s per sample) multi-analyte assays and for field monitoring.  相似文献   

6.
The use of a low pressure ion chromatograph based upon short (25 mm × 4.6 mm) surfactant coated monolithic columns and a low cost paired emitter-detector diode (PEDD) based detector, for the determination of alkaline earth metals in aqueous matrices is presented. The system was applied to the separation of magnesium, calcium, strontium and barium in less than 7 min using a 0.15 M KCl mobile phase at pH 3, with post-column reaction detection at 570 nm using o-cresolphthalein complexone. A comparison of the performance of the PEDD detector with a standard laboratory absorbance detector is shown, with limits of detection for magnesium and calcium using the low cost PEDD detector equal to 0.16 and 0.23 mg L−1, respectively. Finally, the developed system was used for the determination of calcium and magnesium in a commercial spring water sample.  相似文献   

7.
Liu C  Mo YY  Chen ZG  Li X  Li OL  Zhou X 《Analytica chimica acta》2008,621(2):171-177
A new dual detection system for microchip is reported. Both fluorescence detector (FD) and contactless conductivity detector (CCD) were combined together and integrated on a microfluidic chip. They shared a common detection position and responded simultaneously. A blue light-emitting diode was used as excitation source and a small planar photodiode was used to collect the emitted fluorescence in fluorescence detection, which made the device more compact and portable. The coupling of the fluorescence and contactless conductivity modes at the same position of a single separation channel enhanced the detection characterization of sample and offered simultaneous detection information of both fluorescent and charged specimen. The detection conditions of the system were optimized. K+, Na+, fluorescein sodium, fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used to evaluate the performance of the dual detection system. The limits of detection (LOD) of FD for fluorescein Na+, FITC, FITC-labeled arginine (Arg), glycine (Gly) and phenylalanine (Phe) were 0.02 μmol L−1, 0.05 μmol L−1, 0.16 μmol L−1, 0.15 μmol L−1, 0.12 μmol L−1 respectively, and the limits of detection (LOD) of CCD achieved 0.58 μmol L−1 and 0.39 μmol L−1 for K+ and Na+ respectively.  相似文献   

8.
A new simultaneous derivatization and extraction method for the preconcentration of ammonia using new one-step headspace dynamic in-syringe liquid-phase microextraction with in situ derivatization was developed for the trace determination of ammonium in aqueous samples by liquid chromatography with fluorescence detection (LC–FLD). The acceptor phase (as derivatization reagent) containing o-phthaldehyde and sodium sulfite was held within a syringe barrel and immersed in the headspace of sample container. The gaseous ammonia from the alkalized aqueous sample formed a stable isoindole derivative with the acceptor phase inside the syringe barrel through the reciprocated movements of plunger. After derivatization-cum-extraction, the acceptor phase was directly injected into LC–FLD for analysis. Parameters affecting the ammonia evolution and the extraction/derivatization efficiency such as sample matrix, pH, temperature, sampling time, and the composition of derivatization reagent, reaction temperature, and frequency of reciprocated plunger, were studied thoroughly. Results indicated that the maximum extraction efficiency was obtained by using 100 μL derivatization reagent in a 1-mL gastight syringe under 8 reciprocated movements of plunger per min to extract ammonia evolved from a 20 mL alkalized aqueous solution at 70 °C (preheated 4 min) with 380 rpm stirring for 8 min. The detection was linear in the concentration range of 0.625–10 μM with the correlation coefficient of 0.9967 and detection limit of 0.33 μM (5.6 ng mL−1) based on S N−1 = 3. The method was applied successfully to determine ammonium in real water samples without any prior cleanup of the samples, and has been proved to be a simple, sensitive, efficient and cost-effective procedure for trace ammonium determination in aqueous samples.  相似文献   

9.
Cai Z  Chen H  Chen B  Huang C 《Talanta》2006,68(3):895-901
A micro flow injection wetting film liquid-liquid extraction system has been developed for trace analyte concentration and on-chip detection. A hydrophobic channel fabricated on a polycarbonate chip was used to support the wetting film, and hydrostatic pressure generated by the difference in liquid levels was employed to drive the fluids. Sequential injection of segments of aqueous sample solution and organic solvent was conducted by switching the sample- or solvent-containing vials to an on-chip sampling probe, and detection was performed by a co-focused, laser induced fluorescence detector. Using butyl rhodamine B as a model analyte and butanol as the solvent for both film-coating and elution, various experimental conditions such as hydrostatic pressure, coating time, channel length, sampling volume, and sample acidity were investigated. Under optimized conditions, a 24-fold enrichment factor was obtained with the consumption of about 3 μL sample solution, and a detection limit (3σ) of 6.0 × 10−9 M butyl rhodamine B was achieved at the sampling rate of 19 h−1. Eleven consecutive runs of a 1.0 × 10−5 M butyl rhodamine B solution produced a relative standard deviation of 1.5% for the detected fluorescence signals.  相似文献   

10.
There is a need for simple and inexpensive methods to quantify potentially harmful persistent pesticides often found in our water-ways and water distribution systems. This paper presents a simple, relatively inexpensive method for the detection of a group of commonly used pesticides (atrazine, simazine and hexazinone) in natural waters using large-volume direct injection high performance liquid chromatography (HPLC) utilizing a monolithic column and a single wavelength ultraviolet-visible light (UV-vis) detector. The best results for this system were obtained with a mobile phase made up of acetonitrile and water in a 30:70 ratio, a flow rate of 2.0 mL min−1, and a detector wavelength of 230 nm. Using this method, we achieved retention times of less than three minutes, and detection limits of 5.7 μg L−1 for atrazine, 4.7 μg L−1 for simazine and 4.0 μg L−1 for hexazinone. The performance of this method was validated with an inter-laboratory trial against a National Association of Testing Authorities (NATA) accredited liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) method commonly used in commercial laboratories.  相似文献   

11.
J. Ballesta Claver 《Talanta》2009,79(2):499-506
This paper presents an application of chromatographic separation based on an ultra-short monolithic column and chemiluminescent detection in an FIA type instrument manifold for the determination of four paraben mixtures: methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP). The separation is achieved in 150 s using two consecutive carriers: first 12% ACN:water that changes 75 s after injection to 27% ACN:water. The detection is based on the oxidation of the hydrolysis product of parabens, p-hydroxybenzoic acid, with Ce(IV) in the presence of Rhodamine 6G which evokes chemiluminescence of sufficient intensity to enable a sensitive determination of these species. After optimization of the variables involved, the analytical method is characterized, displaying the following values for concentration ranges, detection limits and precision, as relative standard deviation at low concentration (0.15 mg l−1)—MP: from 9.9 × 10−7 to 3.3 × 10−4 M; 1.9 × 10−8; 5.6%; EP: from 9.0 × 10−7 to 3.3 × 10−4 M; 2.8 × 10−8; 3.5%; PP: from 8.3 × 10−7 to 9.9 × 10−5 M; 2.3 × 10−8; 4.2%; and BP: from 7.7 × 10−7 to 9.9 × 10−5 M; 4.2 × 10−8 M; 6.2%. The method was applied and validated satisfactorily for the determination of these parabens in cosmetic samples, comparing the results against a liquid chromatography reference method.  相似文献   

12.
Although capillary electrophoresis (CE) with photometric detection is a well-established technique for the determination of various inorganic ions, its limited sensitivity has hindered greater development in this area. In this work, we used a mixture of metals consisting of Co(II), Ni(II), Zn(II) and Mn(II) to demonstrate that the sensitivity of CE with ultraviolet–visible (UV–vis) detection can be improved by using chromogenic reagents such as porphyrins. To this end, the metals were reacted with 5,10,15,20-tetrakis(4-sulphophenyl)-porphine dodecahydrate (TPPS4) to obtain their respective porphyrinato complexes, which were then separated by CE with a citrate buffer and detected at 410 nm. The ensuing electrophoretic method has a limit of detection (LOD) of 3 × 10−6 M (180 μg L−1) for Co(II), 2 × 10−10 M (0.012 μg L−1) for Ni(II), 4 × 10−6 M (260 μg L−1) for Zn(II) and 4 × 10−9 M (0.219 μg L−1) for Mn(II). The method is a highly promising choice for the ultratrace determination of Ni(II) and Mn(II).  相似文献   

13.
A range of organic solvents (ethanol, isopropanol and acetone) has been investigated as alternatives to acetonitrile and methanol when used in conjunction with Corona Charged Aerosol Detection (Corona CAD). These solvents have been evaluated with regard to their effect on the response of the Corona CAD. Three dimensional response surfaces were constructed using raw data showing the relationship between detector response, analyte concentration and percentage of organic solvent in the mobile phase, using sucralose or quinine as the test analyte. The detector response was non-linear in terms of analyte concentration for all solvents tested. However, detector response varied in an approximately linear manner with percentage of organic solvent over the range 0–40% for ethanol or isopropanol and 0–80% for acetone and methanol. The chromatographic performance of the various solvents when used as aqueous–organic mobile phases was evaluated for isocratic and gradient separations of sugars and sugar alcohols by hydrophilic interaction liquid chromatography (HILIC) using an Asahipak NH2P-504E column coupled with Corona CAD detection. It was found that whilst acetonitrile provided the highest column efficiencies and lowest detection limits of the solvents studied, acetone also performed well and could be used to resolve the same number of analytes as was possible with acetonitrile. Typical efficiencies and detection limits of 5330 plates m−1 and 1.25 μg mL−1, respectively, were achieved when acetone was used as the organic modifier. Acetone was utilised successfully as an organic modifier in the HILIC separation of carbohydrates in a beer sample and also for a partially digested dextran sample.  相似文献   

14.
CE methods have been developed for the analysis of organic and peroxide-based explosives. These methods have been developed for deployment on portable, in-field instrumentation for rapid screening. Both classes of compounds are neutral and were separated using micellar electrokinetic chromatography (MEKC). The effects of sample composition, separation temperature, and background electrolyte composition were investigated. The optimised separation conditions (25 mM sodium tetraborate, 75 mM sodium dodecyl sulfate at 25 °C, detection at 200 nm) were applied to the separation of 25 organic explosives in 17 min, with very high efficiency (typically greater than 300,000 plates m−1) and high sensitivity (LOD typically less than 0.5 mg L−1; around 1–1.5 μM). A MEKC method was also developed for peroxide-based explosives (10 mM sodium tetraborate, 100 mM sodium dodecyl sulfate at 25 °C, detection at 200 nm). UV detection provided LODs between 5.5 and 45.0 mg L−1 (or 31.2–304 μM), which is comparable to results achieved using liquid chromatography. Importantly, no sample pre-treatment or post-column reaction was necessary and the peroxide-based explosives were not decomposed to hydrogen peroxide. Both MEKC methods have been applied to pre-blast analysis and for the detection of post-blast residues recovered from controlled, small scale detonations of organic and peroxide-based explosive devices.  相似文献   

15.
Nitric oxide (NO) plays a very important role in human blood system. In this work, a novel approach has been developed for the quantitation of ultra-trace NO derivatized with 1,3,5,7-tetramethyl-8-(3′,4′-diaminophenyl)-difluoroboradiaza-s- indacene (DAMBO) using a polymer monolith microextraction (PMME) with a poly(methacrylic acid-ethylene glycol dimethacrylate) (MAA-EGDMA) monolith in conjunction with high-performance liquid chromatography (HPLC). Both derivatization and PMME conditions have been optimized in detail. The detection limit of derivatized NO was 2 × 10−12 mol L−1 (signal to noise = 3) and linear range was 9 × 10−11-4.5 × 10−8 mol L−1. The proposed DAMBO-based derivatization-PMME-HPLC-fluorescence detection method has been successfully applied for the determination of NO in 10 μL blood samples of healthy persons and patients suffering from ischemic cardio-cerebrovascular diseases with recoveries varying from 87.40 to 91.60%.  相似文献   

16.
Jun Kato  Michihito Chiba 《Talanta》2009,79(4):1154-1160
Trace amounts of l-cysteine can function as a trigger, i.e., reaction initiator, in the autocatalytic sodium sulfite/hydrogen peroxide reaction system. Rapidly changing of pH after induction time is visually confirmed by color changing of bromothymol blue in this autocatalytic reaction. Based on this finding, μg L−1 levels of l-cysteine were measured over time using the autocatalytic reaction system. The determination range using the above method was 5.0 × 10−8-2.5 × 10−6 M, the detection limit (3σ) was 1.8 × 10−8 M (1.94 μg L−1), and the relative standard deviation was 2.41% at an l-cysteine concentration of 5 × 10−7 M (n = 5). This method was also applied to length detection-flow injection analysis. The determination range for the flow injection analysis was 2.0 × 10−7-1.0 × 10−5 M. The detection limit (3σ) was 1.4 × 10−7 M (17.0 μg L−1), and the relative standard deviation was 0.91% at an initial l-cysteine concentration of 10−6 M (n = 5).  相似文献   

17.
Imipenem shows a fast chemical conversion to a more stable imin form (identical to that of biochemical dehydropeptidase degradation) in aqueous solutions and stabilizing agents used avoid its electrochemical study and determination.The aim of this work is the proposal of urea as stabilizing agent which allows the electrochemical study of imipenem and the proposal of electrochemical methods for the determination of imipenem and its primary metabolite (M1) in human urine samples. Electrochemical studies were realized in phosphate buffer solutions over pH range 1.5-8.0 using differential-pulse polarography, DC-tast polarography, cyclic voltammetry and adsorptive stripping voltammetry. In acidic media, a non-reversible diffusion-controlled reduction involving a two steps mechanism which involves one electron and one proton in the first step and two electrons and two protons in the second step occurs and the mechanism for the reduction was suggested.A differential-pulse polarographic method for the determination of imipenem in the concentration range 3.2 × 10−6 to 2 × 10−5 M (0.95-3.4 mg/L) and its primary metabolite in the concentration range 1.4 × 10−6 to 10−4 M (0.43-26.1 mg/L) with detection limits of 9.6 × 10−7 M (0.28 μg/L imipenem) and 4.3 × 10−7 M (0.14 μg/L M1) was proposed. Also, a method based on controlled adsorptive pre-concentration of imipenem on the hanging mercury drop electrode followed by voltammetric measure, allows imipenem determination in the concentration range 1.8 × 10−8 to 1.2 × 10−6 M (5.42-347 μg/L) with a detection limit of 5.4 × 10−9 M (1.63 μg/L). The proposed methods have been used for the direct determination of the analytes in a pharmaceutical formulation and human urine.  相似文献   

18.
A rapid and sensitive electrospray ionization tandem mass spectrometric (ESI-MS-MS) procedure was developed for the determination of cyanide (CN). CN in biological fluids was reacted with NaAuCl4 to produce dicyanogold, Au(CN)2, which was extracted with methyl isobutyl ketone (MIBK). One microliter of the extract was injected directly into an ESI-MS-MS instrument. Quantification of CN was performed by selected reaction monitoring of the product ion CN at m/z 26 that derived from precursor ion Au(CN)2 at m/z 249. CN could be measured in the quantification range of 10−7 to 5 × 10−5 M with the limit of detection at 4 × 10−8 M using 10 μL of urine within 10 min. A victim's urine and gastric content were diluted with water to 4-fold and 500-fold and measured, respectively.  相似文献   

19.
Liquid chromatography coupled to a silver electrode based flow-through amperometric detector (LC-EC-Ag) was developed for the determination of aminothiols in white wines. The C18 reversed phase LC system operated in the isocratic mode at 0.7 mL min−1 and used an acidic mobile phase composed of formic acid, EDTA, sodium nitrate, sodium hydroxide, and methanol 1% (v/v) at pH 4.5. The working electrode operated at 0.08 V vs Ag/AgCl, 3 M KCl and its manual cleaning was realized once a month by smoothing on a polishing cloth. The analyzed aminothiols were resolved and eluted within 4 min, and all standard curves were linear in the range 2 × 10−7–2 × 10−5 M. The analyzed wine samples needed no preparation other than dilution with the mobile phase. The concentration of cysteine (CYS), homocysteine (HCYS), glutathione (GSH) and N-acetylcysteine (NAC) in bottled white wines, determined by the method of standard addition, was found to be in the low μM range (0.2–2 mg L−1) depending on the wine type and its age.  相似文献   

20.
In-channel indirect amperometric detection mode for microchip capillary electrophoresis with positive separation electric field is successfully applied to some heavy metal ions. The influences of separation voltage, detection potential, the concentration and pH value of running buffer on the response of the detector have been investigated. An optimized condition of 1200 V separation voltage, −0.1 V detection potential, 20 mM (pH 4.46) running buffer of 2-(N-morpholino)ethanesulfonic acid (MES) + l-histidine (l-His) was selected. The results clearly showed that Pb2+, Cd2+, and Cu2+ were efficiently separated within 80 s in a 3.7 cm long native separation PDMS/PDMS channel and successfully detected at a single carbon fibre electrode. The theoretical plate numbers of Pb2+, Cd2+, and Cu2+ were 1.2 × 105, 2.5 × 105, and 1.9 × 105 m−1, respectively. The detection limits for Pb2+, Cd2+, and Cu2+ were 1.3, 3.3 and 7.4 μM (S/N = 3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号