首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Zhang WB  Gan WE  Lin XQ 《Talanta》2006,68(4):1316-1321
A novel electrochemical hydride generator has been developed for the determination of As and Sb. This newly devised hydride generator is constructed from a flowing electrolytic cell, in which the tungsten wire is selected as cathode. Compared with some cathode material usually used in electrochemical hydride generator, the tungsten cathode is of better interference tolerance, corrosion-resistant and longer working time. The characteristics of the cathode material, hydride generating efficiency and interferences of concomitant have been studied in detail. The detection limits (3σ) of As and Sb in sample solution were 0.10 μg L−1 and 0.15 μg L−1, the precisions for 11 replicate measurements of 20 μg L−1 As and Sb were 1.3% and 1.7%. The electrochemical hydride generator coupled with atomic fluorescence spectrometry has been applied to the determination of total As and Sb in tobacco samples.  相似文献   

2.
The development of a direct competitive enzyme-linked immunosorbent assay (ELISA) based on polyclonal antibodies specific for semicarbazide (SEM) is described. Molecular modelling of the hapten mimics and other key components of the assay system was conducted to explain antibody properties in relation to hapten design. The small aliphatic molecule SEM was coupled to 3-carboxybenzaldehyde to produce carboxyphenyl-SEM (CPSEM), for the generation of specific antibodies. Five rabbits produced antibodies against NPSEM (used in direct and indirect ELISA formats) exhibiting a 50% binding inhibition level (IC50 values) of 0.06-2.28 μg L−1 in assay buffer for SEM. The most sensitive indirect assay based on the antibody MVK39 showed a high dynamic range providing a linear readout in the range of 0.01-0.2 μg L−1. Antibody MVK31 (IgG) allowed specific SEM detection at an IC50 = 0.14 μg L−1 in direct ELISA and was evaluated using solvent extracted SEM-spiked porcine and baby food samples. Recovery levels determined from fortified samples (0.5, 1.0, 1.5, 5, 10 and 20 μg kg−1) of porcine and baby food ranged from 82.9 to 105.3%, respectively, with a coefficient of variation less than 15.5%. Respective detection capability and threshold of the assay for porcine muscle, set on the basis of acceptance of no false negative results, was 0.3 and 0.11 μg kg−1.  相似文献   

3.
Competitive electrochemical enzyme-linked immunosorbent assays based on disposable screen-printed electrodes have been developed for quantitative determination of ochratoxin A (OTA). The assays were carried out using monoclonal antibodies in the direct and indirect format. OTA working range, I50 and detection limits were 0.05-2.5 and 0.1-7.5 μg L−1, 0.35 (±0.04) μg L−1 and 0.9 (±0.1) μg L−1, 60 and 100 μg L−1 in the direct and indirect assay format, respectively. The immunosensor in the direct format was selected for the determination of OTA in wheat. Samples were extracted with aqueous acetonitrile and the extract analyzed directly by the assay without clean-up. The I50 in real samples was 0.2 μg L−1 corresponding to 1.6 μg/kg in the wheat sample with a detection limit of 0.4 μg/kg (calculated as blank signal −3σ). Within- and between-assay variability were less than 5 and 10%, respectively. A good correlation (r = 0.9992) was found by comparative analysis of naturally contaminated wheat samples using this assay and an HPLC/immunoaffinity clean-up method based on the AOAC Official Method 2000.03 for the determination of OTA in barley.  相似文献   

4.
A method has been developed to determine acrylamide in aqueous matrices by using direct immersion solid-phase microextraction (SPME) coupled to gas chromatography-positive chemical ionization tandem mass spectrometry (GC-PCI-MS-MS) in the selected reaction monitoring (SRM) mode. The optimized SPME experimental procedures to extract acrylamide in water solutions were: use of a carbowax/divinylbenzene (CW/DVB)-coated fiber at pH 7, extraction time of 20 min and analyte desorption at 210 °C for 3 min. A detection limit of 0.1 μg L−1 was obtained. The linear range was 1-1000 μg L−1. The relative standard deviation was 10.64% (n = 7). The proposed analytical method was successfully used for the quantification of trace acrylamide in foodstuffs such as French fries (1.2 μg g−1) and potato crisps (2.2 μg g−1).  相似文献   

5.
Sensitive and unequivocal determination of analytes/contaminants in complex matrices is a challenge in the field of food safety control. In this study, various acquisition modes (Full MS/AIF, Full MS + tMS/MS, Full MS/dd MS/MS and tSIM/ddMS/MS) and parameters of a quadrupole–orbitrap hybrid mass spectrometer (Q Exactive) were studied in detail. One of the main conclusions has been that, reducing the scan range for Full MS (using the quadrupole) and targeted modes give higher signal-to-noise (S/N) ratios and thereby better detection limits for analytes in matrix. The use of Q Exactive in a complex case, for the confirmatory analysis of hormones in animal urine is presented. A targeted SIM data dependent MS/MS (tSIM/ddMS/MS) acquisition method for determination of eight synthetic hormones (trenbolone, 17α ethinylestradiol, zeranol, stanozolol, dienestrol, diethylstilbestrol, hexestrol, taleranol) and a naturally occurring hormone (zearalenone) in animal urine were optimized to have sensitive precursors from targeted SIM mode and trigger MS/MS scans over the entire chromatograph peak. The method was validated according to EC/657/2002. CCα (decision limit) for the analytes ranged between 0.11 μg L−1 and 0.69 μg L−1 and CCβ (detection capability) ranged between 0.29 μg L−1 and 0.90 μg L−1.  相似文献   

6.
A homogeneous competitive immunoassay for gliadin determination is described for the first time. Gliadins are labeled with a terbium(III) chelate to form the tracer which competes with unlabeled gliadins for the active sites of anti-gliadin antibodies. The terbium(III) is released from the tracer by means of an “acidic enhancement solution” and the initial rate of the dissociation reaction is monitored using the stopped-flow mixing technique. Initial rate values obtained are different depending upon whether tracer is free or bound to antibody which can be correlated with the analyte concentration. The use of the fixed-time method has been also assayed, but it is not suitable as the results depend on the sample matrix. The detection limit of the assay using standards is 4 ng ml−1, which is equivalent to 4 μg g−1 in food samples, and the dynamic range of the method is 0.008-0.36 μg ml−1. The precision, expressed as the percentage of relative standard deviation, was 5-6.2%. The method has been applied to the analysis of gluten-containing and gluten-free food samples, with recoveries ranging from 83.8 to 115.1%.  相似文献   

7.
A novel and highly selective method has been developed for the determination of aromatic primary amines by their conversion to dithiocarbamates by reaction with carbon disulphide, and then to isothiocyanates, which are volatile, by heating in the presence of a heavy metal ion. Zinc(II) was selected owing to its low toxicity and optimum yield of isothiocyanates. The latter were sampled by headspace-solid phase microextraction (HS-SPME) on divinylbenzene-carboxen-polydimethylsiloxane fibre, 50/30 μm. The HS-SPME procedure was optimized to provide adequate limits of detection in the analysis of aromatic amines in their real samples by gas chromatography with mass spectrometry (GC–MS) or flame ionization detection (GC–FID). The method gave rectilinear calibration graph, correlation coefficient and limit of detection, respectively, over the range 0.08–100 μg L−1, 0.9950–0.9990 and 25–240 ng L−1 in gas chromatography–mass spectrometry, and 0.01–10 mg L−1, 0.9910–0.9991 and 0.8–3.0 μg L−1 in gas chromatography–flame ionization detection. At two different levels, 10 and 40 μg L−1, the range of intra-day RSD was 3.7–8.5% (GC–MS) and 3.3–9.2% (GC–FID), respectively. The proposed method is simple and rapid, and has been applied to determine aromatic primary amines in the environmental waters, food samples of ice cream powder and soft drinks concentrate, and food colours. The intra-day RSD in the analysis of real samples by GC–MS was in the range 3.6–6.2%. The food/colour samples were found to contain elevated levels of aniline and 2-toluidine.  相似文献   

8.
Graphene nanosheets, dispersed in Nafion (Nafion-G) solution, were used in combination with in situ plated bismuth film electrode for fabricating the enhanced electrochemical sensing platform to determine the lead (Pb2+) and cadmium (Cd2+) by differential pulse anodic stripping voltammetry (DPASV). The electrochemical properties of the composite film modified glassy carbon electrode were investigated. It is found that the prepared Nafion-G composite film not only exhibited improved sensitivity for the metal ion detections, but also alleviated the interferences due to the synergistic effect of graphene nanosheets and Nafion. The linear calibration curves ranged from 0.5 μg L−1 to 50 μg L−1 for Pb2+ and 1.5 μg L−1 to 30 μg L−1 for Cd2+, respectively. The detection limits (S/N = 3) were estimated to be around 0.02 μg L−1 for Pb2+ and Cd2+. The practical application of the proposed method was verified in the water sample determination.  相似文献   

9.
In situ mercury film electrode produced in the presence of thiocyanate has been shown extremely useful for highly sensitive adsorptive stripping voltammetric measurements of atrazine down to sub-μg L−1 level. Operational parameters have been optimized and the stripping voltammetric performance has been investigated using square wave scans. The adsorptive stripping response is linear over the range of 0.5-60 μg L−1 atrazine, with a detection limit of 0.024 μg L−1. The method has been applied to the determination of atrazine in soil and water samples.  相似文献   

10.
Phthalates (PAEs) are ubiquitous toxic chemical compounds. During the last few years, some phthalate metabolites (MPAEs) have been proposed as appropriate biomarkers in human urine samples to determine PAE human intake and exposure. So, it is necessary to have fast, easy, robust and validated analytical methods to determine selected MPAEs in urine human samples. Two different instrumental methods based on gas (GC) and ultra-high performance liquid (UHPLC) chromatography coupled to mass spectrometry (MS) have been optimized, characterized and validated for the simultaneous determination of nine primary and secondary phthalate metabolites in urine samples. Both instrumental methods have similar sensitivity (detection limits ranged from 0.03 to 8.89 pg μL−1 and from 0.06 to 0.49 pg μL−1 in GC–MS and UHPLC–MS2, respectively), precision (repeatability, expressed as relative standard deviation, which was lower than 8.4% in both systems, except for 5OH-MEHP in the case of GC–MS) and accuracy. But some advantages of the UHPLC–MS2 method, such as more selectivity and lower time in the chromatographic runs (6.8 min vs. 28.5 min), have caused the UHPLC–MS2 method to be chosen to analyze the twenty one human urine samples from the general Spanish population. Regarding these samples, MEP showed the highest median concentration (68.6 μg L−1), followed by MiBP (23.3 μg L−1), 5cx-MEPP (22.5 μg L−1) and MBP (19.3 μg L−1). MMP (6.99 μg L−1), 5oxo-MEHP (6.15 μg L−1), 5OH-MEHP (5.30 μg L−1) and MEHP (4.40 μg L−1) showed intermediate levels. Finally, the lowest levels were found for MBzP (2.55 μg L−1). These data are within the same order of magnitude as those found in other similar populations.  相似文献   

11.
A highly sensitive flow analysis system has been developed for the trace determination of reactive phosphate in natural waters, which uses a polymer inclusion membrane (PIM) with Aliquat 336 as the carrier for on-line analyte separation and preconcentration. The system operates under flow injection (FI) and continuous flow (CF) conditions. Under optimal FI conditions the system is characterised by a linear concentration range between 0.5 and 1000 μg L−1 P, a sampling rate of 10 h−1, a limit of detection of 0.5 μg L−1 P and RSDs of 3.2% (n = 10, 100 μg L−1) and 7.7% (n = 10, 10 μg L−1). Under CF conditions with 10 min stop-flow time and sample solution flow rate of 1.32 mL min−1 the flow system offers a limit of detection of 0.04 μg L−1 P, a sampling rate of 5 h−1 and an RSD of 3.4% (n = 5, 2.0 μg L−1). Interference studies revealed that anions commonly found in natural waters did not interfere when in excess of at least one order of magnitude. The flow system, operating under CF conditions, was successfully applied to the analysis of natural water samples containing concentrations of phosphate in the low μg L−1 P range, using the multipoint standard addition method.  相似文献   

12.
An electrochemical biosensor for the detection of microcystin has been developed based on the inhibition of the protein phosphatase 2A (PP2A) by this cyanobacterial toxin. The enzyme has been immobilised by entrapment using a poly(vinyl alcohol) azide-unit pendant water-soluble photopolymer (PVA-AWP). Electrode supports and immobilisation conditions have been optimised by colorimetric assays, the highest immobilisation yields being obtained with screen-printed graphite electrodes and the 1:2 PP2A:PVA ratio. Catechyl monophosphate (CMP), α-naphthyl phosphate (α-NP) and 4-methylumbelliferyl phosphate (4-MUP) have been used as phosphorylated substrates to monitor the protein phosphatase activity by electrochemical methods, the former providing the highest chronoamperometric currents at appropriate working potentials (+450 mV versus Ag/AgCl). Incubation with standard microcystin solutions has demonstrated the inhibition of the immobilised enzyme, proportional to the toxin concentration. The standard inhibition curve has provided a 50% inhibition coefficient (IC50) of 83 μg L−1, a limit of detection (LOD; 35% inhibition) of 37 μg L−1, and 100% inhibition at about 1000 μg L−1. Real samples of cyanobacterial blooms from the Tarn River (Midi-Pyrénées, France) have been analysed using the developed amperometric biosensor and the toxin contents have been compared to those obtained by a conventional colorimetric protein phosphatase inhibition (PPI) assay and high-performance liquid chromatography (HPLC). The results clearly justify the use of the developed amperometric biosensor as screening method for microcystin detection.  相似文献   

13.
Furazolidone has been banned from use in food animals because of its carcinogenicity and mutagenicity, but its continued misuse is widespread in aquacultures. Therefore, there is an urgent need for a simple, reliable, and rapid method for the detection of its marker residue, 3-amino-2-oxazolidinone (AOZ), in aquatic products. In this regard, we modified a simplified indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) to address this need. A good linearity was achieved over a concentration range of 0.05-12.15 μg L−1, and the IC50 value was 0.96 μg L−1. The sample preparation was simple and effective included water bath treatments, acid hydrolysis combined with overnight derivatization of AOZ by benzaldehyde. The limit of detection and the limit of quantification were 0.15 and 0.3 μg kg−1. The recoveries of AOZ in all tissues were between 78.0-95.3% at the levels of 0.3, 1.0, and 2.0 μg kg−1. The inter-assay variability was less than 19.1%. The modified ic-ELISA was applied in quantification of AOZ elimination in carp. The results showed that AOZ was quite difficult to eliminate. Good correlations of the results obtained by ELISA and LC-MS/MS were observed in incurred carp muscle (r = 0.9923) and carp plasma (r = 0.9915) at the levels of 2.5-571.8 μg kg−1 (μg L−1). Better results were obtained by modified ic-ELISA when compared with commercial ELISA kit. Therefore, the present assay is considered a rapid, accurate, reliable, and inexpensive method for the detection of furazolidone-residues in the edible tissues of aquatic animals.  相似文献   

14.
A homogeneous aggregation immunoassay involving the use of gold nanoparticles (AuNPs) and light scattering detection is described for soy protein determination in food samples. AuNPs act as enhancers of the precipitate that appears when the antigen-antibody complex is formed. The AuNPs-antibody conjugate has been synthesized by physical adsorption of polyclonal anti-soy protein antibodies onto the surface of commercial AuNPs with a nominal diameter of 20 nm. The direct assay is based on the reaction of the conjugate with soy protein, which reaches the equilibrium in about 10 min, and the measurement of the light scattering intensity at 530 nm, which is proportional to the analyte concentration. The dynamic range of the calibration graph is 0.2-20 μg mL−1 and the detection limit value is 65 ng mL−1. The precision, expressed as relative standard deviation, has been assayed at two different concentrations, 0.2 and 1 μg mL−1, giving values ranging from 4.7 to 5.9%. The interference of other proteins has been assayed. The usefulness of this method has been shown by its application to the analysis of fruit juice and “nonmilk yoghourt” samples. The results obtained with the proposed method are similar to those obtained by using a commercial ELISA kit, but the assay time is significantly shorter and the detection limit was about 10 times lower. A recovery study has been also performed, giving values in the range of 84.0-119.3%.  相似文献   

15.
Sassolas A  Catanante G  Fournier D  Marty JL 《Talanta》2011,85(5):2498-2503
A colorimetric protein phosphatase (PP) inhibition test for the detection of microcystin-LR (MC-LR) has been developed. Three PP2As, one recombinant and two natural versions, as well as one PP1 produced by molecular engineering, were tested. First, assays were performed using the enzymes in solution to compare their sensitivity to MC-LR. The PP2A purchased from ZEU Immunotec and PP1 appeared more sensitive to the toxin than the other enzymes. With PP2A from ZEU Immunotec, the colorimetric test showed a detection limit of 0.0039 μg L−1 and an IC50 value of 0.21 μg L−1. With PP1, the assay gave a detection limit of 0.05 μg L−1 and an IC50 value of 0.56 μg L−1. Therefore, this assay allowed the detection of lower microcystin-LR (MC-LR) concentrations than the maximum level (1 μg L−1) recommended by the World Health Organisation (WHO).The main drawback of this PP-based approach in solution is poor enzyme stabilisation. To overcome this problem, enzymes were entrapped within either a photopolymer or an agarose gel. PP2A from ZEU Immunotec and PP1 were immobilised at the bottom of microwells. The agarose-based tests performed better than the photopolymer-based assay for all of the enzymes. Therefore, the agarose gel is a good candidate to replace the photopolymer, which is generally used in PP-immobilising membranes. The assays based on enzyme-entrapping agarose gels showed detection limits equal to 0.17 μg L−1 and 0.29 μg L−1 with immobilised PP2A from ZEU and PP1, respectively. In view of these performances, these tests can potentially be used for monitoring water quality.  相似文献   

16.
A novel disk electrochemical hydride generator has been developed for the determination of As and Sb. Compared with the traditional thin-layer cell, the disk cell combined the advantages of quick assembly and easy operation. This electrochemical system for hydride generation in neutral buffer solutions has been studied for analytical usefulness in coupling with atomic fluorescence spectrometry. It was found that the use of neutral phosphate buffer solution could markedly increase the fluorescence intensity of As(III) and Sb(III) and reduce the impact of cathode erosion on the stability of signal intensity. At the same time, the fluorescence intensity of As(V) and Sb(V) were almost suppressed totally. The detection limits (3σ) of 0.031 μg L−1 As(III) and 0.026 μg L−1 Sb(III) in aqueous solutions were obtained, respectively. The precisions (n = 11) for 20 μg L−1 As(III) and Sb(III) were 2.0% and 2.7%, respectively. The method was successfully applied for determination of different oxidation states of As and Sb in environmental samples.  相似文献   

17.
Liang Y  Liu XJ  Liu Y  Yu XY  Fan MT 《Analytica chimica acta》2008,615(2):174-183
A general and broad class-specific enzyme-linked immunosorbent assay was developed for the O,O-dimethyl organophosphorus pesticides, including malathion, dimethoate, phenthoate, phosmet, methidathion, fenitrothion, methyl parathion and fenthion. Three haptens with different spacer-arms were synthesized. The haptens were conjugated to bovine serum albumin (BSA) for immunogens and to ovalbumin (OVA) for coating antigens. Rabbits were immunized with the immunogens and six polyclonal antisera were produced and screened against each of the coating antigens using competitive indirect enzyme-linked immunosorbent assay for selecting the proper antiserum. The effect of hapten heterology on immunoassay sensitivity was also studied. The antibody-antigen combination with the most selectivity for malathion was further optimized and tested for tolerance to co-solvent, pH and ionic strength changes. The IC50 values, under optimum conditions, were estimated to be 30.1 μg L−1for malathion, 28.9 μg L−1 for dimethoate, 88.3 μg L−1 for phenthoate, 159.7 μg L−1 for phosmet, 191.7 μg L−1 for methidathion, 324.0 μg L−1 for fenitrothion, 483.9 μg L−1 for methyl parathion, and 788.9 μg L−1 for fenthion. Recoveries of malathion, dimethoate, phenthoate, phosmet and methidathion from fortified Chinese cabbage samples ranged between 77.1% and 104.7%. This assay can be used in monitoring studies for the multi-residue determination of O,O-dimethyl organophosphorus pesticides.  相似文献   

18.
Semicarbazide (SEM), the marker residue for the banned nitrofuran veterinary antibiotic nitrofurazone (NFZ), has been detected regularly in foods (47% of recent nitrofuran EU Rapid Alerts involve SEM). However, the validity of SEM as a definitive marker for NFZ has been undermined by SEM arising from other sources including azodicarbonamide, a plastics blowing agent and flour treatment additive. An inexpensive screening test for SEM in food matrices is needed—all SEM testing currently uses expensive LC-MS/MS instrumentation. We now report the first production of antibodies against derivatised SEM. A novel carboxyphenyl SEM derivative was used to raise a polyclonal antibody that has been incorporated into a semi-quantitative microtitre plate ELISA, validated according to the criteria set out in Commission Decision 2002/657/EC, for use with chicken muscle. The antibody is highly specific for derivatised SEM, cross-reactivity being 1.7% with NFZ and negligible with a wide range of other nitrofurans and poultry drugs. Samples are derivatised with o-nitrobenzaldehyde and simultaneously protease digested before extraction by cation exchange SPE. The ELISA has a SEM detection capability (CCβ) of 0.25 μg kg−1 when a threshold of 0.21 μg kg−1 is applied to the selection of samples for confirmation (lowest observed 0.25 μg kg−1 fortified sample, n = 20), thus satisfying the EU nitrofurans’ minimum required performance limit of 1 μg kg−1. NFZ-incurred muscles (12) containing SEM at 0.5-5.0 μg kg−1 by LC-MS/MS, all screened positive by this ELISA protocol which is also applicable to egg and chicken liver.  相似文献   

19.
A cost-effective sequential injection monosegmented flow analysis (SI-MSFA) with anodic stripping voltammetric (ASV) detection has been developed for determination of Cd(II) and Pb(II). The bismuth film working electrode (BiFE) was employed for accumulative preconcentration of the metals by applying a fixed potential of −1.10 V versus Ag/AgCl electrode for 90 s. The SI-MSFA provides a convenient means for preparation of a homogeneous solution zone containing sample in an acetate buffer electrolyte solution and Bi(III) solution for in situ plating of BiFE, ready for ASV measurement at a flow through thin layer electrochemical cell. Under the optimum conditions, linear calibration graphs in range of 10-100 μg L−1 of both Cd(II) and Pb(II) were obtained with detection limits of 1.4 and 6.9 μg L−1 of Cd(II) and Pb(II), respectively. Relative standard deviations were 2.7 and 3.1%, for 11 replicate analyses of 25 μg L−1 Cd(II) and 25 μg L−1 Pb(II), respectively. A sample throughput of 12 h−1 was achieved with low consumption of reagent and sample solutions. The system was successfully applied for analysis of water samples collected from a draining pond of zinc mining, validating by inductively coupled plasma-optical emission spectroscopy (ICP-OES) method.  相似文献   

20.
The influence of the boron-doping levels in boron-doped diamond film electrodes on the electrochemical response of nitrofurantoin (NFT) and the development of an electroanalytical procedure for NFT determination were investigated. The investigations were carried out using the techniques of cyclic voltammetry and square wave voltammetry on diamond film electrodes with different boron-doping levels (i.e., 5000, 10,000 and 20,000 mg L−1). The level of boron-doping in the diamond film electrodes influenced the electrochemical reduction of NFT. The appropriate cyclic voltammetric response of NFT was obtained with Britton-Robinson buffer at pH 4 and for diamond films doped with 10,000 and 20,000 mg L−1 of boron. These two films were selected for the development of the electroanalytical procedure. The use of square wave voltammetry with the optimized parameters demonstrated a good linear relationship between the peak current and the NFT concentration for a wide range of concentration. The lower limit of detection for the electrodes doped with 10,000 and 20,000 mg L−1 of boron were 2.69 × 10−8 mol L−1 (6.40 μg L−1) and 8.15 × 10−9 mol L−1 (1.94 μg L−1), respectively, while the lower limits of quantification were 8.96 × 10−8 mol L−1 (21.33 μg L−1) and 2.72 × 10−8 mol L−1 (6.47 μg L−1), respectively. The applicability of the proposed procedure was tested using a commercial pharmaceutical formulation of NFT, and the results were compared with the procedure recommended by the British Pharmacopeia. The proposed procedure was sensitive, accurate and precise for analysis of NFT and did not require complex preparations or renovations of the electrode surface. This presents the advantage of eliminating mercury waste and minimizing the adsorptive problems related to the use of other electrodic solid surfaces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号