首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(14):2563-2571
Abstract

A DPCSV procedure for the determination of selenium (IV) with a prior preconcentrative coprecipitation on iron (III) hydroxide has been developed. The experimental conditions for coprecipitation of selenium (IV) onto iron (III) hydroxide, viz. pH, iron (III) concentration, volume of aqueous phase and selenium concentration, were optimized. The coprecipitated selenium (IV) is dissolved in 10 ml of 0.1 M HCl and analysed using DPCSV in the presence of copper (II). Selenium concentrations as low as 10–100 ng present in 500 ml of the aqueous phase could be determined. The method is precise and has been applied to the analysis of sea water and reference material samples.  相似文献   

2.
A sequential injection lab-on-valve (LOV) unit, integrating a miniaturized electrochemical flow cell (EFC), has been constructed for the determination of trace amounts of Se (IV) by employing cathodic stripping voltammetry (CSV) technique. The procedure is carried out on a mercury film coated glassy carbon electrode. The analyte solution and electrolyte solution were continuously aspirated and merged in the holding coil (HC) by using a single syringe pump, which were afterwards pushed into the EFC, where the peak current was generated during the subsequent deposition/stripping procedure and measured as the basis of quantification. Assay parameters were optimized in order to achieve the best analytical performance, including mercury film preparation, supporting electrolyte composition, deposition potential and deposition time, and flow variables in the LOV. By loading a sample volume of 500 μL, a linear calibration graph was derived within 1-600 μg L−1, and a detection limit (3б) of 0.11 μg L−1 was achieved along with a sampling frequency of 20 h−1. By integrating the EFC into the LOV unit, the assembling system not only minimized the sample/reagent consumption and waste generation, but also enhanced the sampling frequency. The work itself extended the applications of electrochemical detection techniques and provided a good platform for Se (IV) electrochemical analysis.  相似文献   

3.
Determination of the speciation of arsenic in groundwaters, using cathodic stripping voltammetry (CSV), is severely hampered by high levels of iron and manganese. Experiments showed that the interference is eliminated by addition of EDTA, making it possible to determine the arsenic speciation on-site by CSV. This work presents the CSV method to determine As(III) in high-iron or -manganese groundwaters in the field with only minor sample treatment. The method was field-tested in West-Bengal (India) on a series of groundwater samples. Total arsenic was subsequently determined after acidification to pH 1 by anodic stripping voltammetry (ASV). Comparative measurements by ICP-MS as reference method for total As, and by HPLC for its speciation, were used to corroborate the field data in stored samples. Most of the arsenic (78 ± 0.02%) was found to occur as inorganic As(III) in the freshly collected waters, in accordance with previous studies. The data shows that the modified on-site CSV method for As(III) is a good measure of water contamination with As. The EDTA was also found to be effective in stabilising the arsenic speciation for longterm sample storage at room temperature. Without sample preservation, in water exposed to air and sunlight, the As(III) was found to become oxidised to As(V), and Fe(II) oxidised to Fe(III), removing the As(V) by adsorption on precipitating Fe(III)-hydroxides within a few hours.  相似文献   

4.
The paper presents a procedure for the multi-element inorganic speciation of As(III, V), Se(IV, VI) and Sb(III, V) in natural water with GF-AAS using solid phase extraction technology. Total As(III, V), Se(IV, VI) and Sb(III, V) were determined according to the following procedure: titanium dioxide (TiO2) was used to adsorb inorganic species of As, Se and Sb in sample solution; after filtration, the solid phase was prepared to be slurry for determination. For As(III), Se(IV) and Sb(III), their inorganic species were coprecipitated with Pb-PDC, dissolved in dilute nitric acid, and then determined. The concentrations of As(V), Se(VI) and Sb(V) can be calculated by the difference of the concentrations obtained by the above determinations. For the determination of As(III), Se(IV) and Sb(III), palladium was chosen as a modifier and pyrolysis temperature was 800 °C. Optimum conditions for the coprecipitation were listed for 100 ml of sample solution: pH 3.0, 15 min of stirring time, 40.0 μg l−1 Pb(NO3)2 and 150.0 μg l−1 APDC. The proposed method was applied to the determination of trace amounts of As(III, V), Se(IV, VI) and Sb(III, V) in river water and seawater.  相似文献   

5.
In this study a flow injection (FI) system used in conjunction with hydride generation (HG), atomic absorption spectrometry (AAS) and microwave (MW) aided pre-reduction of selenite (Se(IV)) to selenate (Se(IV)) with HCl:HBr has been developed in order to differentiate both inorganic selenium species. As full control of the MW reduction step is possible, the experimental approach allows the use of milder acidic conditions (10% v/v of HCl and HBr) than those conventionally accomplished with hydrochloric acid alone (≥50% v/v). Experimental parameters were optimized by the univariate optimization method. In either case, the linear range was from 1.0 to 30 μg l−1. The detection limits based on 3σ of the blank signal were 0.25 μg l−1 for Se(IV) and 0.30 μg l−1 for Se(VI). The reproducibility, about 3% RSD and recoveries of different amounts of Se(VI) and Se(IV) added to water and orange juice samples (97–103%) were good. The main advantage of the proposed method is that the sequential determination of Se(IV) and Se(VI) is performed at a high sampling frequency (ca. 50 samples per h) in a closed system without Se losses, and with a minimum sample waste, operator attention, and sample manipulation.  相似文献   

6.
Zhengjun G  Xinshen Z  Guohe C  Xinfeng X 《Talanta》2005,66(4):1012-1017
A simple, accurate, sensitive and selective flow injection catalytic kinetic spectrophotometric method for rapid determination of trace amounts of selenium is proposed in this paper. The proposed method is based on the accelerating effect of Se(IV) on the reaction of ethexlenediamine tetrecetic acid disodium salt (EDTA) and sodium nitrate with ammonium iron(II) sulfate hexahydrate in acidic media. The absorbance intensity was registered in this reaction solution at 440 nm. The calibration graph is linear in the range of 5 × 10−9-2 × 10−7 and 2 × 10−7-2 × 10−6 g ml−1. The detection limit is 2 × 10−9 g ml−1. The relative standard deviation was 3.4% for 5 × 10−8 g ml−1 Se(IV) (n = 11), 2.7% for 5 × 10−7 g ml−1 Se(IV) (n = 11). This method is very simple, rapid and suitable for automatic and continuous analysis. The presented system has been applied successfully to determination of Se(IV) of seawater samples.  相似文献   

7.
The analytical performances of Competitive Ligand Equilibration with Cathodic Stripping Voltammetric detection of the labile fraction (CLE-CSV) were assessed. This speciation method enables the concentration of natural ligand(s) and their conditional stability constants for the complexation of the investigated metal to be determined through thermodynamic considerations.Literature data were discussed and general trends in the precision of the determined parameters identified: ligand concentrations were affected, on average, by a 10% relative percentage standard deviation (RSD%), whereas conditional stability constants showed much lower precision, with an average RSD% of 50%.New experimental data were collected to obtain a complete assessment of accuracy and precision attainable for the determination of strong ligands at the ultra trace level, enabling the whole protocol to be evaluated. Firstly, the side reaction coefficient alpha for the formation of the complex between the added ligand and the investigated metal (αCuL) was determined. The method was subsequently applied to the analysis of solution containing ligand at trace levels (5-50 nM) with known complexing characteristics. Copper was used as the model metal ion and ethylenediaminetetraacetic acid (EDTA) and diethylenetriaminepentaacetic acid (DTPA) as the model ligands. Results evidenced that the CLE-CSV protocol is not affected by systematic errors in the determination of both ligand concentration and the conditional stability constants. Good precision is obtained for ligand concentrations, with an average relative standard deviation (RSD%) of 5%; an average RSD% of 23% was calculated for the conditional stability constants. Including the contribution of the uncertainty in the value of αCuL in the evaluation of the uncertainty in the latter parameter increased the RSD% up to 40%. The CLE-CSV protocol was subsequently applied to the detection of strong ligands in water samples collected in Antarctica: precision was shown to be comparable with literature data.  相似文献   

8.
A voltammetric procedure in the flow system for determination of traces of Cr(VI) in the presence of Cr(III) and humic acid is presented. The calibration graph is linear from 5×10−10 to 1×10−7 mol l−1 for an accumulation time of 120 s. The R.S.D. for 1×10−8 mol l−1 Cr(VI) is 5.3% (n=5). The detection limit estimated from 3σ for a low concentration of Cr(VI) and accumulation time of 120 s is 2×10−10 mol l−1. The method can be used for Cr(VI) determination in the presence of up to 50 mg l−1 of humic acid. The validation of the method was carried out by studying the recovery of Cr(VI) from spiked river water and by the comparison of the results of determination of Cr(VI) in a soil sample. The method cannot be used for analysis of samples containing high concentrations of chloride ions such as seawater and estuarine water.  相似文献   

9.
Uranium (VI) (U(VI)) forms a complex with dipicolinic acid (2, 6-pyridinedicarboxylic acid).This complex can be used for a highly sensitive and selective determination of uranium by adsorptive cathodic stripping voltammetry (ACSV) using a hanging mercury drop electrode (HMDE) as working electrode. Influence of effective parameters such as pH, concentration of ligand, accumulation potential and accumulation time on the sensitivity and selectivity were studied. The detection limit (3σ of the blank value) obtained under the optimal experimental conditions is 0.27 × 10−9 M after 150 s of the accumulation time. The peak current is proportional to the concentration of U(VI) in the range of 1 × 10−9 to 1.2 × 10−7 M. The relative standard deviation of 2.5% at the 3.5 × 10−8 M level was obtained. The interference of some metal ions and anions were studied. The application of this method was tested in the determination of uranium in synthetic and natural water samples.  相似文献   

10.
A study on the simultaneous determination of Ni(II) and Co(II) dimethylglyoximates (Ni‐DMG and Co‐DMG) through adsorptive cathodic stripping voltammetry at an in situ bismuth‐modified gold electrode (Bi‐AuE) is reported. The key operational parameters, such as Bi(III) concentration, accumulation potential and accumulation time were optimized and the morphology of the Bi‐microcrystals deposited on the Au‐electrode was studied. The Bi‐AuE allowed convenient analysis of trace concentrations of solely Ni(II) or of Ni(II) and Co(II) together, with cathodic stripping voltammograms characterized by well‐separated stripping peaks. The calculated limit of detection (LOD) was 40 ng L?1 for Ni(II) alone, whereas the LOD was 98 ng L?1 for Ni(II) and 58 ng L?1 for Co(II), when both metal ions were measured together. The optimized method was finally applied to the analysis of certified spring water (NIST1640a) and of natural water sampled in the Lagoon of Venice. The results obtained with the Bi‐AuE were in satisfactory agreement with the certified values and with those provided by complementary techniques, i.e., ICP‐OES and ICP‐MS.  相似文献   

11.
An analytical method for the determination of taxol (paclitaxel) via cathodic stripping square wave voltammetry has been developed. The method allows to achieve a detection limit of 5.2 ng ml−1 and a determination limit of 11.0 ng ml−1 working with a mercury drop electrode in 0.05 M boric acid/borate buffer pH 9.0, previously accumulated at −0.1 V (v.s. Ag/AgCl/KCl 3 M) for 360 s. Moreover, information about the mechanisms governing the reduction of taxol has been obtained from the studies of the instrumental parameters of square wave voltammetry technique. After addition of an internal standard, taxol was extracted from spiked human urine and the proposed method was successfully applied to the quantification of the analyte.  相似文献   

12.
The voltammetric behaviour of selenium(IV) was studied at platinum and gold electrodes in sulphuric acid, perchloric acid and potassium chloride media as a basis for its voltammetric detection. The best voltammetric behaviour was recorded at gold electrodes with perchloric acid as the supporting electrolyte. The concomitant presence of metals, such as copper or lead, and of model biomolecules, such as bovine serum albumin, in the solution resulted in a deterioration of the electrochemical response for selenium(IV). Quantitative detection of selenium(IV) by square wave anodic stripping voltammetry at both a millimetre-sized gold disc electrode and a microband electrode array revealed linear responses to selenium concentration in the ranges 5–15 μM and 0.1–10 μM, respectively, with 60 s preconcentration. The sensitivities were 6.4 μA μM−1 cm−2 and 100 μA μM−1 cm−2 at the disc and the microband array, respectively. The detection limit at the microband electrode array was 25 nM, illustrating the potentiality of such microelectrodes for the development of mercury-free analytical methods for the trace detection of selenium(IV).  相似文献   

13.
N‐Phenylanthranilic acid was used as a complexing agent for determination of uranium(VI) by adsorptive cathodic stripping voltammetry. Under the optimal experimental conditions of the experimental parameters, the peak current was proportional to the concentration of U(VI) in the range 0.75–30 ng mL?1 and the detection limit was 0.036 ng mL?1. The influence of possible interferences was investigated. The method was applied for determination of uranium in waste water from uranium conversion facility and natural water samples. Application of the method for simultaneous determination of U(VI) and Cu(II) showed that these ions could be simultaneously determined in a single scan at relatively wide concentration range.  相似文献   

14.
《Analytical letters》2012,45(13):1997-2010
Abstract

A very sensitive and reliable method is proposed for the determination of tellurium(IV) [Te(IV)] by Osteryoung square-wave cathodic stripping voltammetry. This method is based on the reduction of Te(IV) with bismuth(III) onto an edge-plane pyrolytic graphite electrode, followed by a cathodic potential scan. The reduced Te gave a well-defined catalytic hydrogen wave at ?1200 mV vs. Ag/AgCl. The peak height of the catalytic wave was directly proportional to the initial Te(IV) concentration in the concentration ranges of 0.01–0.10 and 0.1–1.0 µg L?1 with 30 s deposition time. A 3σ detection limit of 1.0 ng L?1 Te(IV) was obtained with the same deposition time. The relative standard deviation was 3% on replicate runs (n = 5) for the determination of 0.1 µg L?1 Te(IV). Analytical results of natural water samples demonstrate that the proposed method is applicable to the determination of traces of Te(IV).  相似文献   

15.
A method for flotation and determination of selenium(IV) in foodstuffs using p-chlorophenylthiosemicarbazide (HCPT) was investigated. At pH  2, selenium(IV) forms a 1:1 reddish-brown precipitate with HCPT easily floated using oleic acid (HOL) surfactant. The separated complex was dissolved in 4 M HCl and diluted in 10-ml double-distilled water (DDW). Selenium(IV) content in the eluate was determined by hydride generation atomic absorption spectrometry (HG-AAS) at 196.4 nm using sodium borohydride. The HCPT–Se(IV) complexes formed in absence and presence of oleic acid were characterized by elemental analysis, mass and infrared spectral studies. The mode of chelation between Se(IV) and HCPT is proposed to be through S and N coordination. Interferences, on the flotation process, from various foreign ions were avoided by adding excess HCPT. The proposed flotation methodology was successfully applied to the analysis of selenium in real foodstuffs and natural water spiked with known amounts of Se(IV) with a preconcentration factor of 100 and a detection limit of 20 pg. Application was also extended to separate Se(IV) successfully from Se(VI) in their synthetic mixtures. The separation mechanism is proposed to be due to hydrogen bond formation between the COOH group of HOL and –NH of the HCPT–Se(IV) complex.  相似文献   

16.
An analytical procedure regarding the determination of selenium(IV) by anodic stripping voltammetry exploiting the in situ plated bismuth film electrode is described. Since organics are commonly present in untreated natural water samples, the use of Amberlite XAD-7 resin turns out to be quite important to avoid problems such as the adsorption of these compounds on the working electrode. The optimum circumstances for the detection of selenium in water using differential pulse voltammetry techniques were found to be as follows: 0.1 mol L−1 acetic acid, 1.9 × 10−5 mol L−1 Bi(III), 0.1 g Amberlite XAD-7 resin, and successive potentials of −1.6 V for 5 s and −0.4 V for 60 s, during which the in situ formation of the bismuth film on glassy carbon and the accumulation of selenium took place. The current of the anodic peak varies linearly with the selenium concentration ranging from 3 × 10−9 mol L−1 to 3 × 10−6 mol L−1 (r = 0.9995), with a detection limit of 8 × 10−10 mol L−1. The proposed procedure was used for Se(IV) determination in certified reference materials and natural water samples, and acceptable results and recoveries were obtained.  相似文献   

17.
An on-line flow injection system has been developed for the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters by hydride generation atomic absorption spectrometry with microwave-aided heating prereduction of Se(VI) to Se(IV). The samples and the prereductant solutions (4 mol l−1 HCl for Se(IV) and 12 mol l−1 HCl for Se(VI)) which circulated in a closed-flow circuit were injected by means of a time-based injector. This mixture was displaced by a carrier solution of 1% v/v of hydrochloric acid through a PTFE coil located inside the focused microwave oven and mixed downstream with a borohydride solution to generate the hydride. The linear ranges were 0–120 and 0–100 μg l−1 of Se(IV) and Se(VI), respectively. The detection limits were 1.0 μg l−1 for Se(IV) and 1.5 μg l−1 for Se(VI). The precision (about 2.0–2.5% RSD) and recoveries (96–98% for Se(IV) and 94–98% for Se(VI)) were good. Total selenium values were also obtained by electrothermal atomic absorption spectrometry which agreed with the content of both selenium species. The sample throughput was about 50 measurements per hour. The main advantage of the method is that the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters is performed in a closed system with a minimum sample manipulation, exposure to the environment, minimum sample waste and operator attention.  相似文献   

18.
A new methodology was proposed for the speciation of chromium by differential pulse adsorptive stripping voltammetry (DPAdSV) using pyrocatechol violet (PCV) and N-(2-hydroxyethyl)ethylenediamine-N,N′,N′-triacetic acid (HEDTA) as complexing agents. In this procedure, a partial least squares (PLS) regression was used for the resolution of the strongly overlapping voltammetric signals from mixtures of Cr(III) and Cr(VI) in the presence of PCV and HEDTA. The relative error in absolute value was <6% when concentrations of several mixtures were calculated. The analysis of the possible effect of the presence of foreign ions in the solution was performed. The procedure was successfully applied to the speciation of chromium in different samples of natural water.  相似文献   

19.
Cha KW  Park CI  Park SH 《Talanta》2000,52(6):689-989
Uranium(VI) complexed with aluminon (3-[bis(3-carboxy-4-hydroxy-phenyl)methylene]-6-oxo-1,4-cyclohexadiene-1-carboxylic acid triammonium salt) was determined by adsorptive cathodic stripping voltammetry (ACSV) using a hanging mercury drop electrode. Trace uranium(VI) and zinc(II) can be simultaneously determined in a single scan in the presence of aluminon and urea. Optimal conditions were found to be: accumulation time; 180–200 s, accumulation potential; 50 mV versus Ag/AgCl, scan rate; 40 mV s−1, supporting electrolyte; 0.1 M sodium acetate buffer at pH 6.5–7.0, and concentration of aluminon; 1×10−6 M. The linear range of uranium(VI) and zinc(II) were observed over the concentration range 2–33 and 30–120 ng ml−1, respectively. The detection limit (S/N=3) are 0.2 ng ml−1 (uranium) and 30 ng ml−1 (zinc). A good reproducibility shows RSDs of 2.5–4.0% (n=10). The procedure offers high selectivity, with the presence of urea masking some metal ions.  相似文献   

20.
《Electroanalysis》2006,18(3):223-230
This work reports the use of adsorptive stripping voltammetry (AdSV) for the determination of uranium on a preplated rotating‐disk bismuth‐film electrode (BiFE). The principle of the method relied on the complexation of U(VI) ions with cupferron and the subsequent adsorptive accumulation of the complex on the surface of the BiFE. The uranium in the accumulated complex was then reduced by means of a cathodic voltammetric scan while the analytically useful U(VI)→U(V) reduction signal was monitored. The experimental variables as well as potential interferences were investigated and the figures of merit of the method were established. Using the selected conditions, the 3σ limit of detection for uranium was 0.1 μg L?1 at a preconcentration time of 480 s and the relative standard deviation was 4.7% at the 5 μg L?1 level for a preconcentration time of 120 s (n=8). The accuracy of the method was established by analyzing a reference sea water sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号