Costin JW  Barnett NW  Lewis SW 《Talanta》2004,64(4):894-898
Flow injection methodology is described for the determination of proline in red and white wines using tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection. Selective conditions were achieved for proline at pH 10, while other amino acids and wine components did not interfere. The precision of the method was less than 1.00% (R.S.D.) for five replicates of a standard (4 × 10−6 M) and the detection limit was 1 × 10−8 M. The level of proline in white and sparkling wines using the developed methodology was equivalent to those achieved using HPLC-FMOC amino acid analysis. SPE removal of phenolic material was required for red wines to minimize Ru(bipy)33+ consumption and its associated effect on accuracy.  相似文献   

2.
《Analytica chimica acta》2003,476(1):141-148
A flow injection (FI) system combined with two photochemical processes is developed for the sensitive and rapid determination of carbaryl. It is based on the on-line photo-conversion of carbaryl into methylamine which subsequently reacts with Ru(bpy)33+ generated through the on-line photo-oxidation of Ru(bpy)32+ with peroxydisulphate. The linear concentration range of application was 0.04-4.0 μg ml−1 of carbaryl, with an R.S.D. of 1.2% (for a level of 0.50 μg ml−1) and a detection limit of 0.012 μg ml−1. The sample throughput was 200 injections per hour. The applicability of the method was demonstrated by determining carbaryl in commercial formulations, water, soil, grain and blood serum.  相似文献   

3.
Lei Qian  Xiurong Yang 《Talanta》2007,73(1):189-193
In this paper, we demonstrate an electrochemiluminescence (ECL) enhancement of tris(2,2-bipyridyl)ruthenium(II) (Ru(bpy)32+) by the addition of silver(I) ions. The maximum enhancement factor of about 5 was obtained on a glassy carbon electrode in the absence of co-reactant. The enhancement of ECL intensity was possibly attributed to the unique catalytic activity of Ag+ for reactions between Ru(bpy)33+ with OH. The higher enhancement was observed in phosphate buffer solutions compared with that from borate buffer solutions. This resulted from the fact that formation of nanoparticles with large surface area in the phosphate buffer solution exhibited high catalytic activity. The amount of Ag+, solution pH and working electrode materials played important roles for the ECL enhancement. We also studied the effects of Ag+ on Ru(bpy)32+/tripropylamine and Ru(bpy)32+/C2O42− ECL systems.  相似文献   

4.
Li M  Lee SH 《Talanta》2007,74(2):265-270
A simple, rapid flow injection chemiluminescence (FI-CL) method has been developed for selective determination of acenaphthylene (ACY), based on the CL produced in the reaction of tris(2,2′-bipyridine)ruthenium(III) (Ru(bipy)33+) and ACY in an acidic buffer solution. Under the optimum experimental conditions, the calibration curve was linear over the range 5.0 × 10−3 to 4.0 × 10−7 mol L−1 for ACY. The detection limit (S/N = 3) was 2.0 × 10−7 mol L−1 and the relative standard deviation of 10 replicate measurements was 2.3% for 5.0 × 10−5 mol L−1 of ACY. Selectivity of CL reaction of ACY from other 15 polycyclic aromatic hydrocarbons (PAHs) was investigated by flow injection method. The method was applied to determine the ACY content in soil.  相似文献   

5.
Ruthenium complexes containing 4,7-diphenyl-1,10-phenanthroline disulfonate (bathophenanthroline disulfonate; BPS) ligands, Ru(BPS)34−, Ru(BPS)2(bipy)2− and Ru(BPS)(bipy)2, were compared to tris(2,2′-bipyridine)ruthenium(II) (Ru(bipy)32+), including examination of the wavelengths of maximum absorption and corrected emission intensity, photoluminescence quantum yield, stability of their oxidised ruthenium(III) form, and relative chemiluminescence intensities and signal-to-blank ratios with cerium(IV) sulfate and six analytes (codeine, morphine cocaine, potassium oxalate, furosemide and hydrochlorothiazide) in acidic aqueous solution. The presence of BPS ligands in the complex increased the photoluminescence quantum yield, but decreased the stability of the oxidised form of the reagent. In contrast to previous evidence showing much greater electrochemiluminescence intensities using Ru(BPS)2(bipy)2− and Ru(BPS)(bipy)2, these complexes did not provide superior chemiluminescence signals than their homoleptic analogues.  相似文献   

6.
Electrogenerated chemiluminescence (ECL) with tris(4,7-diphenyl-1,10-phenanthrolinedisulfonic acid)rathenium(II) (RuBPS) in solution and immobilized on an electrode surface is investigated. Flow injection analysis with a thin layer electrochemical cell modified for ECL detection is used to determine the analytical utility of solution phase RuBPS and RuBPS immobilized in a cationic polypyrrole derivative. The solution phase reaction of RuBPS with oxalate is investigated with regard to the dependence of ECL emission on RuBPS concentration, carrier stream flow rate, and pH. In the parameter range studied, ECL intensity is not linear with the concentration of RuBPS in the sample. A maximum ECL intensity is observed with a RuBPS concentration of approximately 250 M. Slower linear velocities give greater ECL intensities which is the opposite of what is observed for Ru(bpy) 3 3+ and oxalate. Greater ECL intensity is observed at lower pHs for oxalate and at higher pHs for proline. RuBPS ECL with oxalate yields a working curve with a linear range from 0.1–100 M oxalate. Solution phase ECL is observed for RuBPS and other amines such as NADH, proline, tripropylamine, and antibiotics including streptomycin and gentamicin. RuBPS is also immobilized by electrochemical polymerization of 1-methyl-3-(pyrrol-1-ylmethyl)pyridinium chloride (MPP) in the presence of RuBPS. This polymer-modified electrode yields ECL for oxalate and for amines.Deceased  相似文献   

7.
An electrochemiluminescence (ECL) sensor based on Ru(bpy)32+-graphene-Nafion composite film was developed. The graphene sheet was produced by chemical conversion of graphite, and was characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), and Raman spectroscopy. The introduction of conductive graphene into Nafion not only greatly facilitates the electron transfer of Ru(bpy)32+, but also dramatically improves the long-term stability of the sensor by inhibiting the migration of Ru(bpy)32+ into the electrochemically inactive hydrophobic region of Nafion. The ECL sensor gives a good linear range over 1 × 10−7 to 1 × 10−4 M with a detection limit of 50 nM towards the determination of tripropylamine (TPA), comparable to that obtained by Nafion-CNT. The ECL sensor keeps over 80% and 85% activity towards 0.1 mM TPA after being stored in air and in 0.1 M pH 7.5 phosphate buffer solution (PBS) for a month, respectively. The long-term stability of the modified electrode is better than electrodes modified with Nafion, Nafion-silica, Nafion-titania, or sol-gel films containing Ru(bpy)32+. Furthermore, the ECL sensor was successfully applied to the selective and sensitive determination of oxalate in urine samples.  相似文献   

8.
A new method for uric acid (UA) determination based on the quenching of the cathodic ECL of the tris(2,2-bipyridine)ruthenium(II)–uricase system is described. The biosensor is based on a double-layer design containing first tris(2,2-bipyridine)ruthenium(II) (Ru(bpy)32+) electrochemically immobilized on graphite screen-printed cells and uricase in chitosan as a second layer. The uric acid biosensing is based on the ECL quenching produced by uric acid over the cathodic ECL caused by immobilized Ru(bpy)32+ in the presence of uricase. The use of a −1.1 V pulse for 1 s with a dwelling time of 10 s makes it possible to estimate the initial enzymatic rate, which is used as the analytical signal. The Stern–Volmer type calibration function shows a dynamic range from 1.0 × 10−5 to 1.0 × 10−3 M with a limit of detection of 3.1 × 10−6 M and an accuracy of 13.6% (1.0 × 10−4 M, n = 5) as relative standard deviation. Satisfactory results were obtained for urine samples, creating an affordable alternative for uric acid determination.  相似文献   

9.
A selective novel reverse flow injection system with chemiluminescence detection (rFI-CL) for the determination of Cr(VI) in presence of Cr(III) with Dichlorotris (1,10-phenanthroline)ruthenium(II), (Ru(phen)3Cl2), is described in this work. This new method is based on the oxidation capacity of Cr(VI) in H2SO4 media. First, the Ruthenium(II) complex is oxidized to Ruthenium(III) complex by Cr(VI) and afterwards it is reduced to the excited state of the Ruthenium(II) complex by a sodium oxalate solution, emitting light inside the detector. The intensity of chemiluminescence (CL) is proportional to the concentration of Cr(VI) and, under optimum conditions, it can be determined over the range of 3-300 μg L−1 with a detection limit of 0.9 μg L−1. The RSD was 8.4% and 1.5% at 5 and 50 μg L−1, respectively. For the rFI-CL method various analytical parameters were optimized: flow rate (1 mL min−1), H2SO4 carrier concentration (20% w/V), Ru(phen)3Cl2 concentration (5 mM) and sodium oxalate concentration (0.1 M). The effect of Cr(III), Fe(III), Al(III), Cd(II), Zn(II), Hg(II), Pb(II), Ca(II) and Mg(II), was studied. The method is highly sensitive and selective, allowing a fast, on-line determination of Cr(VI) in the presence of Cr(III). Finally, the method was tested in four different water samples (tap, reservoir, well and mineral), with good recovery percentage.  相似文献   

10.
A highly sensitive and stable tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)32+ immobilized in the ECL sensor by adsorption of Ru(bpy)32+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both titania-Nafion composite films without CNT and pure Nafion films. The present Ru(bpy)32+ ECL sensor based on the MWCNT-titania--Nafion composite gave a linear response (R2 = 0.999) for TPA concentration from 50 nM to 1.0 mM with a remarkable detection limit (S/N = 3) of 10 nM while the ECL sensors based on titania-Nafion composite without MWCNT, pure Nafion films, and MWCNT-Nafion composite gave a detection limit of 0.1 μM, 1 μM, and 50 nM, respectively. The present ECL sensor showed outstanding long-term stability (no signal loss for 4 months).  相似文献   

11.
Chemiluminescence emission intensity is modulated by modulating the potential of a working electrode which is used to generate a key species in the electrogenerated Chemiluminescence (ECL) reaction. The emission is monitored synchronously using a lock-in amplifier. The reactions used in the characterization are luminol with hydrogen peroxide and tris(2,2-bipyridyl)ruthenium (II) (or Ru(bpy) 3 2+ ) with oxalate. Modulation widths of ± 50 mV yield maximum signals for luminol when centered at 0.45 V (vs Ag/AgCl) and for Ru(bpy) 3 2+ when centered at 1.05 V. The resulting signal decreases with increasing modulation frequency and shows that luminol/H2O2 is a faster ECL system than Ru(bpy) 3 2+ /oxalate. Working curves for luminol and for oxalate have essentially the same linear range and slope with the modulated potential approach as with a DC electrode potential. This approach provides capability for differentiating the analytical signal from constant background emission or stray light.  相似文献   

12.
A novel luminescent lifetime optrode is presented for the detection of gaseous and dissolved oxygen. The optrode utilises ruthenium (4,7-diphenyl-1,10-phenanthroline)3Cl2 as the sensing fluorophore immobilised in a hydrophobic ormosil matrix. The ormosil matrix is synthesised at room temperature from octyltriethoxysilane and methyltriethoxysilane precursors. Investigations of different ormosils were conducted and the most effective one was selected for optrode production. Optrodes were tested for responses to gaseous and dissolved oxygen. Their responses were modelled using traditional two-site or two-exponential methods and feed-forward artificial neural networks. Comparison of the two modelling methodologies is presented and further improvements in modelling and ormosil design are suggested.  相似文献   

13.
Ji X  He Z  Pang D 《Electrophoresis》2007,28(18):3260-3267
A novel tris(2,2'-bipyridyl)ruthenium(III) [Ru(bipy)(3) (3+)]-based chemiluminescence (CL) detection in CE using an on-line chemical generation scheme has been demonstrated. Two continuous streams respectively containing solutions of Ru(bipy)(3) (2+) and acidic cerium(IV) used as a homogeneous chemical oxidant are employed to generate Ru(bipy)(3) (3+), which is delivered into the reaction capillary of a coaxial flow interface and then reacted with analytes at the end of the separation capillary to yield light. The important operational parameters for separation and detection are identified and optimized. Four alpha-ketocarboxylic acids used as models, outside of the amine-containing compounds, are successfully separated and detected to evaluate the feasibility of the approach. The excellent resolution and detection sensitivity was achieved by using 50 mmol/L phosphate running buffer (pH 9.5) with 0.7 mmol/L CTAB, and CL reagent solution streams containing 0.15 mmol/L Ru(bipy)(3) (2+) and 0.8 mmol/L cerium(IV) (0.25 mol/L H(2)SO(4)), respectively. The concentration detection limits for alpha-ketocarboxylic acids were below 3.7x10(-8) mol/L (S/N = 3). The proposed method was applied to the determination of alpha-ketocarboxylic acids in five different honey samples with satisfactory results.  相似文献   

14.
A simple, rapid and sensitive method for the determination of psilocin and psilocybin is described. This is the first report on the determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence. The limits of detection (signal-to-noise ratio = 3) are 9 × 10−10 M and 3 × 10−10 M for psilocin and psilocybin, respectively.A concise synthetic route for psilocin in three steps from readily available starting materials is also described. The structures were elucidated on the basis of spectroscopic data.  相似文献   

15.
The optimum performance of an optical oxygen sensor based on polysulfone (PSF)/[Ru(II)-Tris(4,7-diphenyl-1,10-phenanthroline)] octylsulfonate (Ru(dpp)OS) was checked by carefully tuning the parameters affecting the membrane preparation. In particular, membranes having thickness ranging between 0.2 and 8.0 μm with various luminophore concentrations were prepared by dip-coating and tested. The membrane thickness was controlled by tuning the solution viscosity, and was measured both by secondary ion mass spectrometry (SIMS) and by visible spectroscopy (Vis). Luminescence-quenching-based calibration was a single value of the Stern-Volmer constant (KSV) for membranes containing up to 20 mmol Ru(dpp) g−1 PSF (1.35 μm average thickness). The KSV value decreased for larger concentration. The highest sensitivity was obtained with membrane thickness around 1.6 μm, having a response time close to 1 s. Thicker membranes exhibited an emission saturation effect and were characterized by longer response time. The KSV behavior was interpreted on the basis of a mathematical approach accounting for the contribution of luminescence lifetime (τ0), oxygen diffusion coefficient (DO2) and oxygen solubility inside the membrane (sO2) establishing the role of all of them and allowing their experimental determination. Moreover, a simple experimental way to estimate KSV without needing calibration was proposed. It was based either on the light emission asymmetry or on the percent variation of light emission on passing from pure nitrogen to pure oxygen.  相似文献   

16.
Aldehydes and ketones were hydrogenated to the corresponding alcohols, which were then transformed in situ into their respective iodides and nitriles in good yields. A structurally well-defined O-containing transition metal complex, Ru (TMHD)3, was found to be the active catalyst for hydrogenation, iodination and cyanation reactions. It has high affinity for the transformation of benzylic alcohols to iodides and nitriles.  相似文献   

17.
Ohura H  Ishibashi Y  Imato T  Yamasaki S 《Talanta》2003,60(1):177-184
A highly sensitive potentiometric flow injection analysis method for the determination of manganese(II), utilizing a redox reaction with hexacyanoferrate(III) in near neutral media containing ammonium citrate is described. The analytical method is based on the detection of the change in potential of a flow-through type redox electrode detector, resulting from the composition change of an [Fe(CN)6]3−-[Fe(CN)6]4− potential buffer solution. A linear relationship between the potential change (peak height) and the concentration of manganese(II) was found. Manganese(II) in a wide concentration range from 10−4 to 10−7 M could be determined by appropriately altering the concentration of the potential buffer from 10−3 to 10−5 M. The lower detection limit of manganese(II) was determined to be 1×10−7 M. The sampling rate and relative standard deviation were 20 h−1 and 1.9% (n=8) for 6×10−6 M manganese(II), respectively. The proposed method was successfully applied to the determination of manganese(II) in actual soil samples obtained from tea fields. Analytical results obtained by the proposed method were in good agreement with those obtained by an atomic absorption spectrophotometric method.  相似文献   

18.
Amir Waseem 《Talanta》2007,71(1):56-61
A flow injection (FI) method is reported for the determination of thyroxine based on its enhancement of chemiluminescence (CL) from the Ru(bpy)33+-NADH system. The calibration graph was linear over the range 2.0-10 × 10−8 mol L−1 (r2 = 0.9989) with relative standard deviations (R.S.D.) in the range 2.0-4.5% (n = 4). The limit of detection (3σ blank) was 1.0 × 10−9 mol L−1 with sample throughput of 120 h−1. The effect of some organic compounds, anions and cations were studied for l-thyroxine determination. The method was applied to pharmaceutical preparations and the results obtained were in reasonable agreement with the amount labeled. The method was statistically compared with the results obtained by RIA; no significant disagreement at 95% confidence limit was observed. A calibration graph of NADH over the range 1.3 × 10−8-1.3 × 10−6 mol L−1 was also established (r2 = 0.9992) with R.S.D. in the range1.0-3.5% (n = 4). The limit of detection (3σ) was 1.0 × 10−10 mol L−1 NADH.  相似文献   

19.
1 INTRODUCTION terested in the unique effects associated with substituents at 4- and 7-positions of the phenan- The coordination chemistry of 1,l0-phenanthroline throline ring. Thus, when phenyl groups are present, and its derivatives has captured the attention of che- the absorptivities of the CT transitions are increased mists for years. The reports on biological importance[1~4], markedly due to the extension of the dipole moment supramolecular chemistry[5], electronic spectra[6], conne…  相似文献   

20.
The synthesis and characterisation of ruthenium(II) complexes with 2-amidobenzimidazoles are reported. The complexes RuCl2(DMSO)4 and RuCl2(PPh3) react with 2-(acetamido)benzimidazole (AB) and 2-(benzamido)benzimidazole (BB) it acetone to give products of the type [Ru(L)2(N−O)2]Cl2 [L=DMSO, PPh3, N−O=AB, BB). The displacement reactions are faster in the case of methyl (AB) than phenyl (BB) substituted ligands. The ligands are bifunctional chelating agents coordinating through the tertiary nitrogen of benzimidazole ring and amide oxygen. The complexes are characterised based on their elemental analysis, conductivity data, infrared,1H and31P nmr spectra. Acis-geometry is proposed for all the complexes reported.  相似文献   