共查询到8条相似文献,搜索用时 0 毫秒
1.
建立了高效液相色谱-基质辅助激光解吸电离串联飞行时间质谱(MALDI-TOF/TOF MS)分离鉴定牛乳铁蛋白素(bovine lactoferricin, LfcinB)的方法。采用胃蛋白酶酶解牛乳铁蛋白,酶解液离心后取上清液,经过离子交换色谱、反相液相色谱、透析等技术分离,对分离得到的目标产物进行抗菌活性分析、蛋白含量测定和MALDI-TOF/TOF MS鉴定。分离得到高活性的LfcinB,其相对分子质量为3124.89,蛋白含量为18.20 μg/mL。本方法具有精度高、分析速度快和分辨能力强等优点,是其他传统的分析鉴定LfcinB方法所无法比拟的,为进一步研究LfcinB奠定了基础。 相似文献
2.
Qingfang Meng Yangjun Zhang Yun Cai Xiaohong Qian 《Frontiers of Chemistry in China》2007,2(4):447-453
A relative quantitative method for differential proteomics by cleavable isotope-coded affinity tag (cICAT) and matrix-assisted
laser desorption/ionization tandem timeof-flight mass spectrometry (MALDI-TOF-MS) was established. The accuracy and reproducibility
of the method were evaluated by bovine serum albumin (BSA) digest as having a relative standard deviation of less than 30%
and good reproducibility. The dynamic range was also evaluated by analyzing two mixtures of several standard proteins with
different concentration. The experimental results showed that in the dynamic range of 1:30, the quantitation error of the
method was less than 30%. Although the quantitation error becomes very large when used beyond this range, it does not affect
the derivation of information on the differential proteins. All the work provides an alternative method for differential proteomics
analysis in biological samples from different origins.
__________
Translated from Chinese Journal of Analytical Chemistry, 2006, 34(7): 899–904 [译自: 分析化学] 相似文献
3.
糖链结构的质谱解析是今后糖蛋白分析中的重要研究内容,其中完整糖肽的分析,由于可以同时获得糖基化位点和对应糖链的结构信息,更具有重要意义和研究前景。本工作对质谱软电离技术在完整糖肽分析中的应用进行了研究,其中包括了基质辅助激光解吸电离(matrix-assisted laser desorption ionization, MALDI)和电喷雾电离(electrospray ionization, ESI)技术。通过平行使用两种串联质谱(tandem mass spectrometry, MS/MS)分析策略: MALDI-MS/MS和ESI-MS/MS对目标糖蛋白——辣根过氧化物酶进行分析,并讨论了其互补性。结果表明,MALDI和ESI技术各有优劣,结合串联质谱分析,可获得糖肽的糖链结构信息;两条路线互补使用,在揭示蛋白质糖基化修饰(位点和结构)的研究中十分必要。 相似文献
4.
Chao-Jung Chen Chien-Chen Lai Mei-Chun Tseng Yu-Ching Liu Shih-Yi Lin Fuu-Jen Tsai 《Analytica chimica acta》2013
To enhance sample signals and improve homogeneity in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF) analysis, a simple, rapid, and efficient sample preparation method was developed in this study. Polydimethylsiloxane (PDMS) was coated on a stainless steel MALDI plate, forming a transparent, hydrophobic surface that enhanced sample signals without producing observable background signals. Compared to the use of an unmodified commercial metal MALDI plate, peptide signals were enhanced by ~7.1–11.0-fold due to the reduced sample spot area of the PDMS-coated plate, and showed improved peptide mass fingerprinting (PMF) and MS/MS peptide sequencing results. In the analysis of phosphopeptides and carbohydrates with a 2,5-dihydroxybenzoic acid (DHB) matrix, the PDMS-coated plate showed improved sample homogeneity and signal enhancements of ~5.2–8.2-fold and ~2.8–3.2-fold, respectively. Improved sensitivity in the observation of more unique fragment ions by MS/MS analysis, to successfully distinguish isomeric carbohydrates, was also illustrated. In protein analysis with a sinapinic acid (SA) matrix, a ~3.4-fold signal enhancement was observed. The PDMS film coating was easily removed and refabricated to avoid sample carryover, and was applicable to diverse commercial MALDI plates. The PDMS-coated approach is a simple, practical, and attractive method for enhancing analyte signals and homogeneity. 相似文献
5.
Phospholipids possess important physiological, structural and nutritional functions in biological systems. This study described a solid-phase extraction (SPE) method, employing graphene and titanium dioxide (G/TiO2) nanocomposite as sorbent, for the selective isolation and enrichment of phospholipids from avocado (Persea americana Mill.). Based on the principal that the phosphoryl group in the phospholipid can interact with TiO2 via a bridging bidentate mode, an optimum condition was established for SPE, and was successfully applied to prepare avocado samples. The extracts were monitored by matrix-assisted laser desorption ionization time-of-flight/tandem mass spectrometry (MALDI-TOF/MS) in both positive-ion and negative-ion modes. Results showed that phospholipids could be efficiently extracted in a clean manner by G/TiO2 based SPE. In addition, the signals of phospholipids were enhanced while the noise was reduced. Some minor peaks became more obvious. In conclusion, the nanocomposite material of G/TiO2 was proved to be a promising sorbent for selective separation of phospholipids from crude lipid extract. 相似文献
6.
The blood free fatty acids (FFAs), which provide energy to the cell and act as substrates in the synthesis of fats, lipoproteins, liposaccharides, and eicosanoids, involve in a number of important physiological processes. In the present study, matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR MS) with ammonia-treated N-(1-naphthyl) ethylenediamine dihydrochloride (ATNEDC) as a novel MALDI matrix in a negative ion mode was employed to directly quantify serum FFAs. Multiple point internal standard calibration curves between the concentration ratios of individual fatty acids to internal standard (IS, C17:0) versus their corresponding intensity ratios were constructed for C14:0, C16:1, C16:0, C18:0, C18:1, C18:2, C18:3, C20:4, and C22:6, respectively, in their mixture, with correlation coefficients between 0.991 and 0.999 and limits of detection (LODs) between 0.2 and 5.4 μM, along with the linear dynamic range of more than two orders of magnitude. The results indicate that the multiple point internal standard calibration could reduce the impact of ion suppression and improve quantification accuracy in the MALDI mode. The quantitative results of nine FFAs from 339 serum samples, including 161 healthy controls, 118 patients with hyperglycemia and 60 patients without hyperglycemia show that FFAs levels in hyperglycemic patient sera are significantly higher than those in healthy controls and patients without hyperglycemia, and elevated FFA levels are also associated with increased levels of fasting blood glucose (FBG) in hyperglycemic patient sera. Serum FFAs were identified on the basis of the observed accurate molecular masses and reliable isotope distributions obtained by MALDI-FTICR MS. 相似文献
7.
A novel matrix of isoliquiritigenin (ISL), a flavonoid with a chalcone structure (4,2′,4′-trihydroxychalcone), was demonstrated to be advantageous in the analysis of neutral oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). With ISL as a matrix, adequate signal for an analyte can be obtained in much lower matrix concentrations and laser intensity compared to commonly used MALDI matrices. Four different sample preparation methods were tested, and the dried droplet method exhibited the best performance on MALDI-TOF-MS analysis of oligosaccharides with ISL as a matrix. For the analysis of carbohydrates, compared with popular matrices such as 2,5-dihydroxybenzoic acid (DHB) and 2,4,6-trihydroxyacetophenone (THAP), ISL exhibited outstanding matrix properties as follows: (1) higher homogeneity of crystallization thus allowing automatic data acquisition, (2) better spectral quality in terms of resolution and signal to noise ratio (S N−1), (3) better salt tolerance, (4) higher sensitivity, and (5) enough fragmentation yield to use LIFT-TOF/TOF MS to get richer structural information. In addition, reliable quantitative analysis of oligosaccharides with a good linearity over two concentration orders (1–100 pmol μL−1) and good reproducibility of the signal intensity (RSD less than 15%) were achieved using this matrix. These results give a new outlook on high-speed analysis of neutral carbohydrates by MALDI-TOF MS. 相似文献
8.
Marijana Petkovi? Julia Müller Jürgen Schiller Jürgen Arnhold 《Microchemical Journal》2005,80(1):31-37
Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) was successfully applied for the analysis of various lipid classes. It can also be used for monitoring the digestion of phosphatidylcholine (PC) with phospholipase A2 (PLA2) and it was shown that MALDI-TOF MS possesses a number of advantages over well established methods for this purpose. In this work, we use MALDI-TOF MS for determination of the substrate specificity of neutrophil PLA2. For the comparison of the selectivity of the enzyme to various phospholipid (PL) classes, the intensities of the signals arising from the product of the reaction (Sp) and the signal intensity of the residual substrate (Ss) were compared and the resulting Sp/Ss ratio was used as the measure. This approach was first tested with a model system pancreatic PLA2 and afterwards two sources of the neutrophil PLA2—the enzyme extracted from the neutrophils and the enzyme released from these cells—were tested for their substrate specificity. We will show that the neutrophil-secreted PLA2 possesses high preferences for digestion of phosphatidic acid (PA) over other phospholipids. The method applied here is simple and much information can be obtained from a single mass spectrum. Moreover, this approach works well also with a crude biological systems, i.e. no prior purification of the enzyme is required for means of characterisation. 相似文献