首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
2.
Management of domestic wastes often relies on incineration, a process that eliminates large amount of wastes but also produces toxic residues that concentrate heavy metals. Those hazardous secondary wastes require specific treatment. Vitrification is seen as a powerful way to stabilise them. However, concern exists about the long term behaviour of these glass wastes and the potential release of toxic species into the environment. The answers will come with further investigation into the physico-chemical evolution of the vitrified wastes and the mobility of hazardous elements within the matrix with appropriate analytical methods. Laser ablation coupled with inductively coupled mass spectrometry (LA-ICP-MS) is a challenging technique for the chemical analysis of trace elements in solid materials. This paper presents an evaluation of the potential of LA- ICP-MS for macro and microanalysis of trace metals in domestic vitrified wastes with regards to other physical analytical techniques of solids such as scanning electronprobe X-ray energy dispersive spectroscopy (SEM-EDXS). Two typical samples, vitreous and crystallised, are used to compare the analytical performances of the two techniques. SEM-EDXS was used for mineralogical characterisation and chemical analysis of the mineralogical phases. Relative micro-analysis and bulk quantitative analysis of 30 major, minor and trace elements was performed by LA-ICP-MS: precision was between 10 and 20% for most elements and quantitative analysis proved possible with an accuracy of 20% and relative detection limits of 0.1 mg kg(-1).  相似文献   

3.
X-ray diffraction (XRD) mapping consists in the acquisition of XRD patterns at each pixel (or voxel) of an area (or volume). The spatial resolution ranges from the micrometer (μXRD) to the millimeter (MA-XRD) scale, making the technique relevant for tiny samples up to large objects. Although XRD is primarily used for the identification of different materials in (complex) mixtures, additional information regarding the crystallite size, their orientation, and their in-depth distribution can also be obtained. Through mapping, these different types of information can be located on the studied sample/object. Cultural heritage objects are usually highly heterogeneous, and contain both original and later (degradation, conservation) materials. Their structural characterization is required both to determine ancient manufacturing processes and to evaluate their conservation state. Together with other mapping techniques, XRD mapping is increasingly used for these purposes. Here, the authors review applications as well as the various configurations for XRD mapping (synchrotron/laboratory X-ray source, poly-/monochromatic beam, micro/macro beam, 2D/3D, transmission/reflection mode). On-going hardware and software developments will further establish the technique as a key tool in heritage science.  相似文献   

4.
激光剥蚀串联电感耦合等离子体质谱法(LA-ICP-MS)是一种功能强大的化学元素检测方法,它具有样品前处理简单、多元素同时测定、高通量、高灵敏度、宽线性范围以及原位分析等优点。同时,激光剥蚀可以与多接收器电感耦合等离子体质谱仪(MC-ICP-MS)串联用于稳定同位素组成测定,不仅避免了繁琐的样品前处理,同时还可应用于固体样品的微区原位同位素分析,揭示微观尺度上稳定同位素组成的变化。LA-ICP-MS已广泛应用于地质、考古等领域,其在环境科学领域应用相对起步较晚,但近年来发展迅速。该文总结了近年来LA-ICP-MS的环境分析方法开发及其在环境科学中的应用进展,并对其未来发展趋势进行了展望。  相似文献   

5.
The possibility of quantitative elemental analysis of solids by laser ablation - inductively coupled plasma - mass spectrometry (LA-ICP-MS) has been investigated. The solids were mixed with a flux and fused to a glass bead so that a similar matrix composition would be obtained for the different samples (matrix matching), and an internal standard could be added. Strontium, present in the flux materials, was found to be suitable as the internal standard. Two major problems were experienced in the analysis: memory effects and interference from polyatomic ions. The memory effects were probably due to deposits of particles in the transfer tubes between the laser ablation cell and the ICP torch. At masses below 80 m/z, strong interferences from polyatomic ions caused serious problems in the quantification and, for elements studied in that mass region, detection limits were poor. The technique was further applied more specifically to the determination of rare earth elements in geological materials, for which detection limits varied from 0.02 to 3 mg/kg. Quantitative analysis, independent of the kind of sample material, proved possible.  相似文献   

6.
Waste polymer materials were analyzed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The concentrations of 35 elements were determined by using different types of external standards, namely glass and polyethylene (PE) based. Prior to the LA-ICP-MS analysis of determined elements, Na and/or Zn were used as internal standards. The investigations concentrated mainly on the detection of Cr, As, Cd, Sn, Sb, Hg, and Pb. Using PE-based calibration standards, the measured concentrations in the waste polymers were within 49% of the wet chemical data. The determined deviation was up to 102% when using the glass standards. Trace concentration of As and Hg (and also of S) could be determined with a concentration below 1 mg/kg. However, Hg provided very low intensity with a high relative standard deviation (RSD) and was therefore not further evaluated. Cryomilling of polymers was applied to reduce the particle size of the material and improved the precision and accuracy of LA-ICP-MS analysis. On average, the LA-ICP-MS results showed a deviation from the wet chemical reference analysis of 38% and an RSD of 56% for pressed polymer powder samples prepared by cryomilling. In general, waste pellets without sample preparation (i.e., use of pellets as delivered) are too heterogeneous, not suitable for micro-beam techniques, and showed a strong matrix dependence. With homogeneous pellets that appear similar to each other agreement in the determined concentrations was found for some elements.  相似文献   

7.
There is a growing interest in using biomonitoring of tooth and bone specimens to assess human exposure to manganese (Mn). Information on historical exposure to Mn can be obtained through micro-spatial analysis of such specimens by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The principal aim of this study was to compare several calibration strategies for determining Mn content in tooth and bone by LA-ICP-MS including: (a) a six-point calibration curve based on synthesized hydroxyapatite (HA) materials, and single-point calibrations based on (b) NIST SRM 1400 Bone Ash, (c) NIST SRM 1486 Bone Meal, and (d) NIST SRM 612 Trace Elements in Glass. Performance was similar between different ICP-MS platforms (quadrupole ICP-MS, dynamic reaction cell ICP-MS, and sector field ICP-MS). Data based on calibration using the 55Mn count rate were compared to that based on using the 55Mn/43Ca count rate ratio to obtain results as the Mn mass fraction. Reasonable performance was obtained by calibration using either SRM 612 or SRM 1400, in combination with the 55Mn/43Ca count rate ratio and using either the synthesized HA standards or SRM 1400 as calibrators, combined with 55Mn count rate. By contrast, calibration based on SRM 1486 resulted in a systematic low bias. While there are several options for quantifying the Mn content of tooth and bone using LA-ICP-MS, users should be aware of the potential for strong matrix effects that may affect results. Overall, determining the 55Mn/43Ca count rate ratio, rather than the mass fraction, may represent a better approach for reporting the content of Mn in tooth and bone by LA-ICP-MS.  相似文献   

8.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science.  相似文献   

9.
The combination of element-specific investigation by low temperature gas chromatography coupled on-line with inductively coupled plasma optical emission spectroscopy (LT-GC/ICP-OES) and gas chromatography using mass spectrometry detection (GC-MS), as an additional analytical technique for molecular identification, was employed for the determination of volatile organosilicon species. Gaseous and liquid samples from waste deposit sites, waste composting tanks and sewage-disposal plants were investigated. It was frequently possible to identify the labile silanol compound trimethylsilanol as a dominant silicon species in waste disposal and waste composting gases. The results presented give rise to the assumption that trimethylsilanol is a volatile product of the degradation of organosilicon materials under special environmental conditions. Received: 24 July 1997 / Revised: 8 October 1997 / Accepted: 21 October 1997  相似文献   

10.
Smith K  Horton K  Watling RJ  Scoullar N 《Talanta》2005,67(2):402-413
The nature of art lends itself to forgery as a skilled and determined forger can mimic the techniques and styles of an artist to a level where even an expert can be duped. The authentication of paintings is a subjective process, but modern techniques may provide the means to provenance artist pigments based on elemental composition. This study applies laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) to the analysis of artist paints from different manufacturers to identify variation between the elemental association patterns of these materials. The technique facilitates comparison of the paints used by an artist with produced works of art to assist provenancing initiatives of questioned materials. The effects of the trace element profiles of the backing substrate and binder on analytical data were also identified. By applying the technique to paint scraped from real paintings, a limited database was created to allow comparison to be made with some of Australian artist, Kathleen O’Connor's artworks and assist in determining production chronology. Data from this study were able to facilitate comparison of blue paints from two different paintings and confirm their co-provenance consequently determining the relative production date of a separate painting of previously unknown age.Preliminary trials of a prototype collection device designed to reduce damage and allow for in situ sampling of artworks were also undertaken. The device, which allows direct laser-based sampling of a complete painting, was tested using a Francis Ryan painting. The prototype allows for the collection of debris directly generated by LA-ICP-MS of a predefined area of a painting prior to subsequent analysis using direct LA-ICP-MS. This collection method significantly minimizes the amount of damage produced by conventional sampling methods. Analyses of the debris collected, using the prototype, were found to be comparable to the scrapings of equivalent paint analysed using direct LA-ICP-MS analysis.  相似文献   

11.
A comparison study of the measurement of metals in ambient particulate matter collected on air filters, using energy-dispersive X-ray fluorescence (ED-XRF), laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) and wet chemical digestion followed by ICP-MS analysis according to the European ‘reference method’ EN14902, is presented. Whilst it is shown that the methods have a low systematic bias with respect to each other, overall they do show a high random variability, and when considered individually using regression methods, some analytes have shown bias with respect to the EN14902 method. The low systematic bias observed is not unexpected since both the ED-XRF and LA-ICP-MS methods have been calibrated using results from the EN14902 technique. The uncertainty of each analysis has been estimated and compared with the data quality objectives for uncertainty specified in the relevant European air quality legislation. This has tentatively shown that approximately 75% of the analyses using ED-XRF and LA-ICP-MS meet the requirements of the legislation. However, improvements in repeatability and calibration methods for both ED-XRF and LA-ICP-MS would be needed before these methods were truly applicable for routine use in air quality measurements of this type.  相似文献   

12.
The capability of LA-ICP-MS for determination of trace impurities in transparent quartz glasses was investigated. Due to low or completely lacking absorption of laser radiation, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) proves difficult on transparent solids, and in particular the quantification of measurement results is problematic in these circumstances. Quartz glass reference materials of various compositions were studied by using a Nd:YAG laser system with focused laser radiation of wavelengths of 1064 nm, 532 nm and 266 nm, and an ICP-QMS (Elan 6000, Perkin Elmer). The influence of ICP and laser ablation conditions in the analysis of quartz glasses of different compositions was investigated, with the laser power density in the region of interaction between laser radiation and solid surface determining the ablation process. The trace element concentration was determined via calibration curves recorded with the aid of quartz glass reference materials. Under optimized measuring conditions the correlation coefficients of the calibration curves are in the range of 0.9–1. The relative sensitivity factors of the trace elements determined in the quartz glass matrix are 0.1–10 for most of the trace elements studied by LA-ICP-MS. The detection limits of the trace elements in quartz glass are in the low ng/g to pg/g range.  相似文献   

13.
The capability of LA-ICP-MS for determination of trace impurities in transparent quartz glasses was investigated. Due to low or completely lacking absorption of laser radiation, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) proves difficult on transparent solids, and in particular the quantification of measurement results is problematic in these circumstances. Quartz glass reference materials of various compositions were studied by using a Nd:YAG laser system with focused laser radiation of wavelengths of 1064 nm, 532 nm and 266 nm, and an ICP-QMS (Elan 6000, Perkin Elmer). The influence of ICP and laser ablation conditions in the analysis of quartz glasses of different compositions was investigated, with the laser power density in the region of interaction between laser radiation and solid surface determining the ablation process. The trace element concentration was determined via calibration curves recorded with the aid of quartz glass reference materials. Under optimized measuring conditions the correlation coefficients of the calibration curves are in the range of 0.9-1. The relative sensitivity factors of the trace elements determined in the quartz glass matrix are 0.1-10 for most of the trace elements studied by LA-ICP-MS. The detection limits of the trace elements in quartz glass are in the low ng/g to pg/g range.  相似文献   

14.
简单介绍了激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)的基本原理及装置。分别对LA-ICP-MS在飞秒激光器、紫外激光器、固液气溶胶混合进样、集合式小样品标样、原位统计分布技术上的技术新进展进行了详细的评述。最后对LA-ICP-MS在元素含量分析与空间分布分析中所占的地位及其应用前景进行了展望。  相似文献   

15.
 Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used as a powerful multielement analytical method for trace analysis of geological glasses which are useful as reference materials for geochemical in-situ microanalytical work. The quantification of the analytical results was carried out using the BCR-2G and NIST 612 glass standard reference material (SRM). The experimentally determined relative sensitivity coefficients (RSC) for both SRMs vary between 0.2 and 3 for most of the elements, with increasing mass an increasing of relative sensitivity coefficients was observed. The relative standard deviation (RSD) for determination of trace element concentration of most elements (N=3) are between 2 and 10%. The determination of trace elements in various geological glasses by LA-ICP-MS yielded a good agreement with the reference values and those results of other trace analytical methods. Received October 15, 1999. Revision April 14, 2000.  相似文献   

16.
Calibration materials for microanalysis of Ti minerals have been prepared by direct fusion of synthetic and natural materials by resistance heating in high-purity graphite electrodes. Synthetic materials were FeTiO3 and TiO2 reagents doped with minor and trace elements; CRMs for ilmenite, rutile, and a Ti-rich magnetite were used as natural materials. Problems occurred during fusion of Fe2O3-rich materials, because at atmospheric pressure Fe2O3 decomposes into Fe3O4 and O2 at 1462 degrees C. An alternative fusion technique under pressure was tested, but the resulting materials were characterized by extensive segregation and development of separate phases. Fe2O3-rich materials were therefore fused below this temperature, resulting in a form of sintering, without conversion of the materials into amorphous glasses. The fused materials were studied by optical microscopy and EPMA, and tested as calibration materials by inductively coupled plasma mass spectrometry, equipped with laser ablation for sample introduction (LA-ICP-MS). It was demonstrated that calibration curves based on materials of rutile composition, within normal analytical uncertainty, generally coincide with calibration curves based on materials of ilmenite composition. It is, therefore, concluded that LA-ICP-MS analysis of Ti minerals can with advantage be based exclusively on calibration materials prepared for rutile, thereby avoiding the special fusion problems related to oxide mixtures of ilmenite composition. It is documented that sintered materials were in good overall agreement with homogeneous glass materials, an observation that indicates that in other situations also sintered mineral concentrates might be a useful alternative for instrument calibration, e.g. as alternative to pressed powders.  相似文献   

17.
Because multielement trace analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is often limited by the lack of suitable reference materials with a similar matrix composition, a novel quantification strategy using solution calibration was developed. For mass spectrometric multielement determination in geological samples a quadrupole-based LA-ICP-MS is coupled with an ultrasonic nebulizer (USN). In order to arrange matrix matching the standard solutions are nebulized with a USN during solution calibration and simultaneously a blank target (e.g. lithium borate) is ablated with a focused laser beam. The homogeneous geological samples were measured using the same experimental arrangement where a 2% nitric acid is simultaneously nebulized with the USN. Homogeneous targets were prepared from inhomogeneous geological samples by powdering, homogenizing and fusing with a lithium borate mixture in a muffle furnace at 1050 degrees C. Furthermore, a homogeneous geological glass was also investigated. The quantification of analytical results was performed by external calibration using calibration curves measured on standard solutions. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS, measured concentrations in homogeneous geological targets were also corrected with relative sensitivity coefficients (RSCs) determined using one standard solution only. The analytical results of LA-ICP-MS on various geological samples are in good agreement with the reference values and the results of other trace analytical methods. The relative standard deviation (RSD) for trace element determination (N = 6) is between 2 and 10%.  相似文献   

18.
The laser ablation (LA) method is an effective technique for quantitative analysis. In the present work, a new LA system was developed for the high-sensitivity analysis of metal materials using inductively coupled plasma mass spectrometry (ICP-MS). This system consists of a high-frequency Q-switched laser and 2 scanning mirrors for scanning the ablation spot in an adequately large area of the specimen without vacant spaces. The influence of elemental fractionation (non-stoichiometric generation of vapor species) can be eliminated by repetitive irradiation of this pattern on the same area. Particles generated with an average laser power of 0.6 W with the developed LA system gave intensity and stability substantially similar to that of a 500 microg/ml solution steel sample in solution ICP-MS. The analytical performance of the developed LA-ICP-MS was compared with that of a solution ICP-MS using NIST steel SRMs. The performance of the newly-developed system is comparable to that of conventional solution ICP-MS in both accuracy and precision. The correlation coefficients between the contents and the intensity ratios to Fe were over 0.99 for most elements. The relative standard deviation (RSD) obtained by LA-ICP-MS revealed that this system can analyze iron samples with good precision. The results of ultra trace level analysis of high-purity iron showed that developed LA-ICP-MS is capable of analyzing ppm concentration levels with a 20 - 30 ppb level standard deviation. The detection limit was on the order of 10 ppb for most elements.  相似文献   

19.
The source of signal variations that governs the analytical performance of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was investigated in this study. In order to specify the source of signal variations of LA-ICP-MS, laser-induced plasma (LIP) Fe emission, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals were used as internal standards for the determination of trace elements in low-alloy steel certified reference materials (BS 50D and JSS 1005-1008). Fe 1373.5 nm emission signals from LIP were measured, while trace element LA-ICP-MS signals were collected. After that, the LIP emission signals, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals were used as internal standards, and the analytical performance was evaluated by the RSDs and the correlation coefficients (r) of the calibration curves. The improvement factors were dependent on the internal standardization methods. Analytical precisions (RSDs) of trace element LA-ICP-MS signals were improved by factors of 1.5-3.3 using LIP Fe emission signals as an internal standard. The improvement factors of 2.5 - 5.9 and 4.1 - 17 were obtained by using LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals as internal standards, respectively. Better correlation coefficients (r) were also obtained using the LA-ICP-MS signal compensation (0.9985 by LA-ICP-MS Fe+ and 0.9996 by LA-ICP-MS Ni+) rather than the LIP Fe emission compensation (0.9932). In this paper we compare and discuss the analytical performance achieved by LA-ICP-MS using LIP Fe emission, LA-ICP-MS Fe+ and LA-ICP-MS Ni+ signals as internal standards.  相似文献   

20.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been established as a powerful and sensitive surface analytical technique for the determination of concentration and distribution of trace metals within biological systems at micrometer spatial resolution. LA-ICP-MS allows easy quantification procedures if suitable standard references materials (SRM) are available. In this work a new SRM-free approach of solution-based calibration method in LA-ICP-MS for element quantification in hair is described. A dual argon flow of the carrier gas and nebulizer gas is used. A dry aerosol produced by laser ablation (LA) of biological sample and a desolvated aerosol generated by pneumatic nebulization (PN) of standard solutions are carried by two different flows of argon as carrier or nebulizer gas, respectively and introduced separately in the injector tube of a special ICP torch, through two separated apertures. Both argon flows are mixed directly in the ICP torch. External calibration via defined standard solutions before analysis of single hair was employed as calibration strategy. A correction factor, calculated using hair with known analyte concentration (measured by ICP-MS), is applied to correct the different elemental sensitivities of ICP-MS and LA-ICP-MS. Calibration curves are obtained by plotting the ratio of analyte ion M+/34S+ ion intensities measured using LA-ICP-MS in dependence of analyte concentration in calibration solutions. Matrix-matched on-line calibration in LA-ICP-MS is carried out by ablating of human hair strands (mounted on a sticky tape in the LA chamber) using a focused laser beam in parallel with conventional nebulization of calibration solutions. Calibrations curves of Li, Na, Mg, Al, K, V, Cr, Mn, Fe, Ni, Co, Cu, Zn, Sr, Mo, Ag, Cd, I, Hg, Pb, Tl, Bi and U are presented. The linear correlation coefficients (R) of calibration curves for analytes were typically between 0.97 and 0.999. The limits of detection (LODs) of Li, V, Mn, Ni, Co, Cu, Sr, Mo, Ag, Ba, Cd, I, Hg, Pb, Bi and U in a single hair strand were in the range of 0.001-0.90 μg g−1, whereas those of Cr and Zn were 3.4 and 5.1 μg g−1, respectively. The proposed quantification strategy using on-line solution-based calibration in LA-ICP-MS was applied for biomonitoring (the spatial resolved distribution analysis) of essential and toxic metals and iodine in human hair and mouse hair.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号