首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Hua MY  Chen HC  Tsai RY  Lai CS 《Talanta》2011,85(1):631-637
The imine of polybenzimidazole (PBI) is chemically oxidized by hydrogen peroxide (H2O2) in the presence of acetic acid (AcOH). Fourier transform infrared (FT-IR) and X-ray photoelectron spectroscopies (XPS) showed that when the AcOH concentration remained constant, the degree of oxidation increased with increasing H2O2 levels. Moreover, the imine also exhibited electrochemical redox behavior. Based on these properties, a PBI-modified Au (PBI/Au) electrode was developed as an enzyme-free H2O2 sensor. At an applied potential of −0.5 V vs. Ag/AgCl, the current response of the PBI/Au electrode was linear with H2O2 concentration over a range from 0.075 to 1.5 mM, with a sensitivity of 55.0 μA mM−1 cm−2. The probe had excellent stability, with <5% variation from its initial response current after storage at 50 °C for 10 days. Potentially interfering species such as ascorbic or uric acid had no effect on sensitivity. Sensitivity improved dramatically when multiwalled carbon nanotubes (MWCNT) were incorporated in the probe. Under optimal conditions, the detection of H2O2 using a MWCNT-PBI/Au electrode was linear from 1.56 μM to 2.5 mM, with a sensitivity of 928.6 μA mM−1 cm−2. Analysis of H2O2 concentrations in urine samples using a MWCNT-PBI/Au electrode produced accurate real-time results comparable to those of traditional HPLC methods.  相似文献   

2.
Direct electron transfer between redox enzymes and electrodes is the basis for the third generation biosensors. We established direct electron transfer between quinohemoprotein alcohol dehydrogenase (PQQ-ADH) and modified carbon black (CBs) electrodes. Furthermore, for the first time, this phenomenon was observed for pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase (PQQ-GDH). Reagentless enzyme biosensors suitable for the determination of ethanol, glucose and sensors for hydrogen peroxide were designed using CB electrodes and screen-printing technique. Aiming to create an optimal transducing material for biosensors, a set of CB batches was synthesized using the matrix of Plackett-Burman experimental design. Depending on the obtained surface functional groups as well as the nano-scale carbon structures in CBs batches, the maximal direct electron transfer current of glucose and ethanol biosensors can vary from 20 to 300 nA and from 30 to 6300 nA for glucose and ethanol, respectively. Using modified CB electrodes, an electrocatalytic oxidation of H2O2 takes place at more negative potentials (0.1-0.4 V versus Ag/AgCl). Moreover, H2O2 oxidation efficiency depends on the amount and morphology of fine fraction in the modified CBs.  相似文献   

3.
F.J. Rawson  J. Xu  P.R. Fielden  J.P. Hart 《Talanta》2009,77(3):1149-723
The present study demonstrated for the first time that screen-printed carbon microband electrodes fabricated from water-based ink can readily detect H2O2 and that the same ink, with the addition of lactate oxidase, can be used to construct microband biosensors to measure lactate. These microband devices were fabricated by a simple cutting procedure using conventional sized screen-printed carbon electrodes (SPCEs) containing the electrocatalyst cobalt phthalocyanine (CoPC). These devices were characterised with H2O2 using several electrochemical techniques. Cyclic voltammograms were found to be sigmoidal; a current density value of 4.2 mA cm−2 was obtained. A scan rate study revealed that the mass transport mechanism was a mixture of radial and planar diffusion. However, a further amperometric study under quiescent and hydrodynamic conditions indicated that radial diffusion predominated. A chronoamperometric study indicated that steady-state currents were obtained with these devices for a variety of H2O2 concentrations and that the currents were proportional to the analyte concentration. Lactate microband biosensors were then fabricated by incorporating lactate oxidase into the water-based formulation prior to printing and then cutting as described. Voltammograms demonstrated that lactate oxidase did not compromise the integrity of the electrode for H2O2 detection. A potential of +400 mV was selected for a calibration study, which showed that lactate could be measured over a dynamic range of 1-10 mM which was linear up to 6 mM; a calculated lower limit of detection of 289 μM was ascertained. This study provides a platform for monitoring cell metabolism in-vitro by measuring lactate electrochemically via a microband biosensor.  相似文献   

4.
Nanoporous (NP) PdFe alloy is easily fabricated through one step mild dealloying of PdFeAl ternary source alloy in NaOH solution. Electron microscopy characterization demonstrates that selectively dissolving Al from PdFeAl alloy generates three-dimensional bicontinuous nanospongy architecture with the typical ligament size around 5 nm. Electrochemical measurements show that the NP-PdFe alloy exhibits the superior electrocatalytic activity and durability towards hydrogen peroxide (H2O2) detection compared with NP-Pd and commercial Pd/C catalysts. In addition, NP-PdFe performs high sensing performance towards H2O2 in a wide linear range from 0.5 to 6 mM with a low detection limit of 2.1 μM. This nanoporous structure also can sensitively detect glucose over a wide concentration range (1–32 mM) with a low detection limit of 1.6 μM and high resistance against chloride ions. Along with these attractive features, the as-made NP-PdFe alloy also has a good anti-interference towards ascorbic acid, uric acid, and dopamine.  相似文献   

5.
Qian L  Yang X 《Talanta》2006,68(3):721-727
A new amperometric biosensor for hydrogen peroxide was developed based on cross-linking horseradish peroxidase (HRP) by glutaraldehyde with multiwall carbon nanotubes/chitosan (MWNTs/chitosan) composite film coated on a glassy carbon electrode. MWNTs were firstly dissolved in a chitosan solution. Then the morphology of MWNTs/chitosan composite film was characterized by field-emission scanning electron microscopy. The results showed that MWNTs were well soluble in chitosan and robust films could be formed on the surface. HRP was cross-linked by glutaraldehyde with MWNTs/chitosan film to prepare a hydrogen peroxide biosensor. The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for H2O2 in the absence of a mediator. The linear range of detection towards H2O2 (applied potential: −0.2 V) was from 1.67 × 10−5 to 7.40 × 10−4 M with correction coefficient of 0.998. The biosensor had good repeatability and stability for the determination of H2O2. There were no interferences from ascorbic acid, glucose, citrate acid and lactic acid.  相似文献   

6.
Qu F  Shi A  Yang M  Jiang J  Shen G  Yu R 《Analytica chimica acta》2007,605(1):28-33
Prussian blue nanowire array (PBNWA) was prepared via electrochemical deposition with polycarbonate membrane template for effective modification of glassy carbon electrode. The PBNWA electrode thus obtained was demonstrated to have high-catalytic activity for the electrochemical reduction of hydrogen peroxide in neutral media. This enabled the PBNWA electrode to show rapid response to H2O2 at a low potential of −0.1 V over a wide range of concentrations from 1 × 10−7 M to 5 × 10−2 M with a high sensitivity of 183 μA mM−1 cm−2. Such a low-working potential also substantially improved the selectivity of the PBNWA electrode against most electroactive species such as ascorbic acid and uric acid in physiological media. A detection limit of 5 × 10−8 M was obtained using the PBNWA electrode for H2O2, which compared favorably with most electroanalysis procedures for H2O2. A biosensor toward glucose was then constructed with the PBNWA electrode as the basic electrode by crosslinking glucose oxidase (GOx). The glucose biosensor allowed rapid, selective and sensitive determination of glucose at −0.1 V. The amperometric response exhibited a linear correlation to glucose concentration through an expanded range from 2 × 10−6 M to 1 × 10−2 M, and the response time and detection limit were determined to be 3 s and 1 μM, respectively.  相似文献   

7.
《中国化学会会志》2018,65(9):1082-1089
In this work, a screen‐printed carbon electrode (SPCE) was modified with a cobalt/porous silicon (Co@PSi) nanocomposite powder to develop a nonenzymatic sensor for the detection of hydrogen peroxide. The Co@PSi nanocomposite was synthesized through the chemical reaction between silicon powder in a HF/HNO3 solution and cobalt cations. In this process, cobalt nanoparticles were anchored on the porous silicon. The structure and morphology of the synthesized nanocomposite were investigated by X‐ray diffraction, Fourier transform infrared spectroscopy, X‐ray photoemission spectroscopy, energy dispersive X‐ray spectroscopy, and field‐emission scanning electron microscopy. The constructed nonenzymatic, screen‐printed sensors based on the Co@PSi nanocomposite showed perfect electrocatalytic oxidation response to hydrogen peroxide over the range 1–170 and 170–3,770 μmol/L with the limit of detection of 0.8 μmol/L. In addition, the Co@PSi‐SPCE sensor exhibited good selectivity for the determination of H2O2 in the presence of common interfering species including glucose, ascorbic acid, uric acid, dopamine, nitrate, and nitrite ions. The constructed electrochemical sensor was successfully used for the determination of H2O2 in real samples.  相似文献   

8.
Li S  Zheng Y  Qin GW  Ren Y  Pei W  Zuo L 《Talanta》2011,85(3):1260-1264
In this paper, an enzyme-free amperometric electrochemical sensor was fabricated by casting Nafion-impregnated Cu2O particles onto a glassy carbon electrode. A dual dependence of peak current on sweeping rate, which can be attributed for the accumulation of reaction products, was observed on the sensor. Electrochemical analysis of the particulate Cu2O for detecting H2O2 and glucose is described, showing remarkable sensitivity in both cases. The estimated detection limits and sensitivities for H2O2 (0.0039 μM, 52.3 mA mM−1 cm−2) and glucose (47.2 μM, 0.19 mA mM−1 cm−2) suggest that the response for H2O2 detection was much higher than for glucose detection. Electron microscopy observation suggested that the hierarchical structures of Cu2O resulting from self-assembly of nanocrystals are responsible for the specific electrochemical properties.  相似文献   

9.
In this paper, we synthesized flowerlike silver microspheres with nanostructures by simply reducing silver nitrate by ascorbic acid in the presence of PVP. The structure was investigated by SEM. The chemical composition was determined by EDX, XRD and XPS. Recent studies on hydrogen peroxide sensor based on silver nanoparticles inspired us to examine the electrocatalytic activity of prepared microspheres. This electrochemical sensor exhibited good electrocatalytic activity towards the reduction of H2O2 in 0.2 M phosphate buffer solution (pH 7.0), and the detection limit of H2O2 was found to be 1.2 μM, which was lower than certain enzyme-based biosensors.  相似文献   

10.
Fengna Xi 《Talanta》2009,78(3):1077-360
A simple and controllable electrodeposition approach was established for one-step construction of novel reagentless biosensors by in situ formation of chitosan-carbon nanotubes-nile blue-horseradish peroxidase (CS-CNTs-NB-HRP) biocomposite film on electrode surface. The mediator effect of NB, conducting performance of CNTs and the biocompatible microenvironment of CS were combined by such one-step non-manual process. NB could interact with CNTs and resulted in good dispersion of CNTs-NB nanocomposites in aqueous solution. Cyclic voltammetry measurements demonstrated that electrons were efficiently shuttled between HRP and the electrode mediated by NB. The developed reagentless biosensor exhibited a fast amperometric response for the determination of H2O2 and 95% of the steady-state current was obtained within 2 s. The linear response of the reagentless biosensor for the determination of H2O2 ranged from 1.0 × 10−6 to 2.4 × 10−4 mol l−1 with a detection limit of 1.2 × 10−7 mol l−1. The biosensor exhibited high reproducibility and long-time storage stability. The as-prepared biosensor also showed effective anti-interference capability. The ease of the one-step non-manual technique and the promising feature of the biocomposite could serve as a versatile platform for fabricating electrochemical biosensors.  相似文献   

11.
A colloidal suspension of nanostructured poly(N-butyl benzimidazole)-graphene sheets (PBBIns-Gs) was used to modify a gold electrode to form a three-dimensional PBBIns-Gs/Au electrode that was sensitive to hydrogen peroxide (H2O2) in the presence of acetic acid (AcOH). The positively charged nanostructured poly(N-butyl benzimidazole) (PBBIns) separated the graphene sheets (Gs) and kept them suspended in an aqueous solution. Additionally, graphene sheets (Gs) formed “diaphragms” that intercalated Gs, which separated PBBIns to prevent tight packing and enhanced the surface area. The PBBIns-Gs/Au electrode exhibited superior sensitivity toward H2O2 relative to the PBBIns-modified Au (PBBIns/Au) electrode. Furthermore, a high yield of glucose oxidase (GOD) on the PBBIns-Gs of 52.3 mg GOD per 1 mg PBBIns-Gs was obtained from the electrostatic attraction between the positively charged PBBIns-Gs and negatively charged GOD. The non-destructive immobilization of GOD on the surface of the PBBIns-Gs (GOD-PBBIns-Gs) retained 91.5% and 39.2% of bioactivity, respectively, relative to free GOD for the colloidal suspension of the GOD-PBBIns-Gs and its modified Au (GOD-PBBIns-Gs/Au) electrode. Based on advantages including a negative working potential, high sensitivity toward H2O2, and non-destructive immobilization, the proposed glucose biosensor based on an GOD-PBBIns-Gs/Au electrode exhibited a fast response time (5.6 s), broad detection range (10 μM to 10 mM), high sensitivity (143.5 μA mM−1 cm−2) and selectivity, and excellent stability. Finally, a choline biosensor was developed by dipping a PBBIns-Gs/Au electrode into a choline oxidase (ChOx) solution for enzyme loading. The choline biosensor had a linear range of 0.1 μM to 0.83 mM, sensitivity of 494.9 μA mM−1 cm−2, and detection limit of 0.02 μM. The results of glucose and choline measurement indicate that the PBBIns-Gs/Au electrode provides a useful platform for the development of oxidase-based biosensors.  相似文献   

12.
A Pt electrode modified by a polypyrrole/poly(orthophenylenediamine) bilayer membrane able to entrap large molecules such as glucose oxidase was used to investigate (at 27°C and pH 7) the kinetics of ascorbic acid (AA) oxidation by hydrogen peroxide (H2O2 + AA → 2H2O + DAA) by following the H2O2 concentration as a function of time. The largely unmatched rejection characteristics of this device towards AA permitted it to operate even in the presence of high AA/H2O2 ratios, e.g. 1000: 1. Under these conditions, pseudo-first-order kinetic constant values ranging from 3.26 × 10−3 to 4.10 × 10−3 s−1 were obtained at [AA] = 2 mM and initial [H2O2] = 2 μM. The potential influence of the above reaction on sensitivity and reliability of H2O2-detecting biosensors in the presence of AA is discussed critically, taking into account also the recent, and sometimes conflicting, literature views on the problem.  相似文献   

13.
《Analytical letters》2012,45(9):1733-1753
ABSTRACT

High sensitive glucose biosensors were realised by oxidative polymerisation of amphiphilic pyrrole monomer-glucose oxidase mixtures, previously adsorbed on platinum electrodes. These sensors, based on H2O2 electrooxidation at 0.5V vs SCE, exhibited marked interferences due to electrooxidisable endogenous (ascorbate and urate) and exogenous (paracetamol) compounds. Bilayer structures, combining the preceding polymer film as an outer layer and electrogenerated poly(phenylene diamine), overoxidised polypyrrolic films or Nafion as an inner layer, were fabricated in order to minimise interferences. Finally, the use of Nafion as a semipermeable barrier appeared to be more efficient than the electrogenerated films. The Nafion-based biosensor exhibited glucose sensitivity of 0.4 mA.M?1; .cm?2, while interference of ascorbate, urate and paracetamol was negligible.  相似文献   

14.
In this paper, the highly intrinsic peroxidase-like catalytic activity of nitrogen-doped graphene quantum dots (N-GQDs) is revealed. This activity was greatly dependent on pH, temperature and H2O2 concentration. The experimental results showed that the stable N-GQDs could be used for the detection of H2O2 and glucose over a wide range of pH and temperature, offering a simple, highly selective and sensitive approach for their colorimetric sensing. The linearity between the analyte concentration and absorption ranged from 20 to 1170 μM for H2O2 and 25 to 375 μM for glucose with a detection limit of 5.3 μM for H2O2 and 16 μM for glucose. This assay was also successfully applied to the detection of glucose concentrations in diluted serum and fruit juice samples.  相似文献   

15.
Nanoporous platinum–cobalt (NP–PtCo) alloy with hierarchical nanostructure is straightforwardly fabricated by dealloying PtCoAl alloy in a mild alkaline solution. Selectively etching Al resulted in a hierarchical three-dimensional network nanostructure with a narrow size distribution at 3 nm. The as-prepared NP–PtCo alloy shows superior performance toward ethanol and hydrogen peroxide (H2O2) with highly sensitive response due to its unique electrocatalytic activity. In addition, NP–PtCo also exhibits excellent amperometric durability and long-term stability for H2O2 as well as a good anti-interference toward ascorbic acid, uric acid, and dopamine. The hierarchical nanoporous architecture in PtCo alloy is also highly active for glucose sensing electrooxidation and sensing in a wide linear range. The NP–PtCo alloy holds great application potential for electrochemical sensing with simple preparation, unique catalytic activity, and high structure stability.  相似文献   

16.
An amperometric glucose biosensor was developed using an anionic clay matrix (layered double hydroxide (LDH), Ni/Al-NO3) for the immobilization of glucose oxidase (GOx). The biofilm was prepared by electrodeposition of the clay and GOx and subsequent cross-linking with glutaraldeyde. The Pt surface modified with the Ni/Al-NO3 shows a much reduced noise, giving rise to a better signal to noise ratio for the currents relative to H2O2 oxidation, and a linear range for H2O2 determination wider than the one observed for bare Pt electrodes. Under the optimised operative conditions, the performances of the biosensor have been evaluated by measuring the steady-state currents (at +0.45 V versus SCE) to increasing concentrations of glucose in “air saturated” 0.1 M phosphate buffer (pH 7.0). Both batch and flow injection modes were explored. The response to glucose was linear up to 8.0 and 12.0 mM, and the sensitivities were 7.7 ± 0.1 and 19.1 ± 0.2 mA M−1 cm−2, respectively. The current response of the biosensors does not significantly change for 15 consecutive days in batch and for 10 days in flow, at least, if stored at 4 °C in phosphate buffer, when not in use. The effects of interferants and applicability to fruit juices and soft drinks analysis of the biosensor were also investigated.  相似文献   

17.
In this paper, LaNi0.6Co0.4O3 (LNC) nanoparticles were synthesized by the sol–gel method, and the structure and morphology of LNC nanoparticles were characterized by X-ray diffraction spectrum, scanning electron microscopy and transmitting electron microscopy. And then, LNC was used to modify carbon paste electrode (CPE) without any adhesive to fabricate hydrogen peroxide and glucose sensor, and the results demonstrated that LNC exhibited strong electrocatalytical activity by cyclic voltammetry and amperometry. In H2O2 determination, linear response was obtained in the concentration range of 10 nM–100 μM with a detection limit of 1.0 nM. In glucose determination, there was the linear region of 0.05–200 μM with a detection limit of 8.0 nM. Compared with other reports, the proposed sensor also displayed high sensitivity toward H2O2 (1812.84 μA mM−1 cm−2) and glucose (643.0 μA mM−1 cm−2). Moreover, this prepared sensor was applied to detect glucose in blood serum and hydrogen peroxide in toothpaste samples with satisfied results, indicating its possibility in practical application.  相似文献   

18.
A unique approach of developing a bar code version of lateral-flow enzymatic-based assay for the semi-quantification of hydrogen peroxide is described. The proposed assay system is mainly composed of a goat anti-mouse IgG-horseradish peroxidase conjugate (Gt anti-M IgG-HRP)-coated nitrocellulose (NC) membrane and a peroxidase substrate pad. Unlike the bar code immunochromatographic assay which depends on the stepwise capture of analyte, the principle of enzyme-based bar code lateral-flow assay is based on the different reaction time on successive lines due to the delay in 3,3′,5,5′-tetramethylbenzidine (TMB) release. Hydrogen peroxide (H2O2) acts as a limiting factor which controls the rate of the enzymatic conversion of TMB to blue color complex. The system expresses the concentration of H2O2 in micromole range as three distinct ladder bars in 9 min therefore without the need of any reading device. The major advantages of this assay are its easily readable result, and also its simplicity and low-cost in production offers a cheaper alternative for testing those expensive biosensors might not be available to the third world countries. By incorporating with H2O2-generating oxidoreductases, the assay can be further extended to detect a variety of analytes with clinical and environmental importance. Glucose was chosen to be the model analyte where the proposed system gave signal response at between 5 μM and 100 μM.  相似文献   

19.
Creation and application of noble metal nanoclusters have received continuous attention. By integrating enzyme activity and fluorescence for potential applications, enzyme-capped metal clusters are more desirable. This work demonstrated a glucose oxidase (an enzyme for glucose)-functionalized gold cluster as probe for glucose. Under physiological conditions, such bioconjugate was successfully prepared by an etching reaction, where tetrakis (hydroxylmethyl) phosphonium-protected gold nanoparticle and thioctic acid-modified glucose oxidase were used as precursor and etchant, respectively. These bioconjugates showed unique fluorescence spectra (λem max = 650 nm, λex max = 507 nm) with an acceptable quantum yield (ca. 7%). Moreover, the conjugated glucose oxidase remained active and catalyzed reaction of glucose and dissolved O2 to produce H2O2, which quenched quantitatively the fluorescence of gold clusters and laid a foundation of glucose detection. A linear range of 2.0 × 10−6–140 × 10−6 M and a detection limit of 0.7 × 10−6 M (S/N = 3) were obtained. Also, another horseradish peroxidase/gold cluster bioconjugate was produced by such general synthesis method. Such enzyme/metal cluster bioconjugates represented a promising class of biosensors for biologically important targets in organelles or cells.  相似文献   

20.
H2O2 is a widely occurring molecule which is also a byproduct of a number of enzymatic reactions. It can therefore be used to quantify the corresponding enzymatic substrates. In this study, the time-resolved fluorescence emission of a previously described complex consisting of phthalic acid and terbium (III) ions (PATb) is used for H2O2 detection. In detail, glucose oxidase and choline oxidase convert glucose and choline, respectively, to generate H2O2 which acts as a quencher for the PATb complex. The response time of the PATb complex toward H2O2 is immediate and the assay time only depends on the conversion rate of the enzymes involved. The PATb assay quantifies glucose in a linear range of 0.02–10 mmol L−1, and choline from 1.56 to 100 μmol L−1 with a detection limit of 20 μmol L−1 for glucose and 1.56 μmol L−1 for choline. Both biomolecules glucose and choline could be detected without pretreatment with good precision and reproducibility in human serum samples and infant formula, respectively. Furthermore, it is shown that the detected glucose concentrations by the PATb system agree with the results of a commercially available assay. In principle, the PATb system is a universal and versatile tool for the quantification of any substrate and enzyme reaction where H2O2 is involved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号