首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Liying Wang 《Talanta》2009,78(1):265-3377
Based on well-known silver mirror reaction the Ag film was formed on Au film modified by self-assembled monolayer (SAM) of 1,6-hexanedithiol (HDT). The sensitivity of the biosensor based on this Ag/Au film is enhanced compared to that based on Au film. When the surface plasmon resonance (SPR) biosensor based on this Ag/Au film was used to determine human IgG, the range of concentrations of human IgG that could be determined is 0.30-40.00 μg mL−1. The lowest concentration (0.30 μg mL−1) that could be detected was about 8 times lower than that obtained by the biosensor without modification by Ag film (2.50 μg mL−1), which demonstrated that the biosensor based on Ag/Au film could make the resonant wavelength move to longer wavelength following with the sensitivity enhancement of the SPR biosensor.  相似文献   

2.
This paper reports the utilization of triangular silver nanoplates (TSNPs) to enhance the sensitivity of surface plasmon resonance (SPR) biosensor. TSNPs modified with 3-mercaptopropinic acid (MPA) were simply mixed with chitosan and glutaraldehyde to form TSNPs/chitosan composite. The composite was deposited on Au film as immobilization substrate for SPR biosensor. The novel structures of TSNPs are preserved against etching by MPA and chitosan polymer. Moreover, chitosan cross-linked by glutaraldehyde enables antibody to be immobilized on fabricated substrate directly via Schiff alkali reaction. In the optimized conditions, the resulting biosensor based on TSNPs/chitosan composite shows a satisfactory response to bovine IgG in the concentration range of 0.075–40.00 μg mL−1. While the biosensor based on chitosan without TSNPs shows a response in the concentration range of 0.6–40 μg mL−1 and the biosensor based on Au film shows a response in the concentration range of 2.5–40 μg mL−1. The experiment results show that the sensitivity of SPR biosensor based on TSNPs/chitosan composite was significantly enhanced and the immobilization procedure of antibody was simplified.  相似文献   

3.
Sun Y  Song D  Bai Y  Wang L  Tian Y  Zhang H 《Analytica chimica acta》2008,624(2):294-300
The conjugates of magnetic beads coupled with an antibody can be trapped on the Au film firmly due to the magnetic force for the immunoassay of a surface plasmon resonance (SPR) biosensor. However, this approach exhibits significant limitations in robustness and sensitivity due to incomplete dissociation of magnetic beads from the Au film. The incorporation of a polyelectrolyte film on the Au surface can prevent the magnetic beads from the direct contact with the Au film. The layer-by-layer assembly of polyelectrolyte was used as spacer between the gold surface and the magnetic bead. Different layers of polyelectrolyte can be assembled onto the Au film based on an electrostatic force between polycations and polyanions. After the polyelectrolyte film was fabricated on the Au film, the deposition of the magnetic beads was maintained effectively on the film, which favors the sensitivity of the biosensor and the regeneration of the sensing membrane. When the polyelectrolyte layers of (PAH/PSS)3 were constructed on the Au film, the SPR biosensor with magnetic beads exhibited a satisfactory response to human IgG in the concentration range from 0.25 to 30.00 μg mL−1, and the determination limit obtained is eight times lower than that obtained with (PAH/PSS)1 layer.  相似文献   

4.
Four simple, rapid, accurate, precise, reliable and economical spectrophotometric methods have been proposed for simultaneous determination of salbutamol sulphate (SS), bromhexine hydrochloride (BH) and etofylline (ET) in pure and commercial formulations without any prior separation or purification. They were first derivative zero crossing spectrophotometry (method 1), simultaneous equation method (method 2), derivative ratio spectra zero crossing method (method 3) and double divisor ratio spectra derivative method (method 4). The ranges for SS, BH and ET were found to be 1-35 μg mL−1, 4-40 μg mL−1 and 5-80 μg mL−1. For methods 1 and 2, the values of limit of detection (LOD) were 0.2314 μg mL−1, 0.4865 μg mL−1 and 0.2766 μg mL−1 and the values of limit of quantitation (LOQ) were 0.7712 μg mL−1, 1.6217 μg mL−1 and 0.9221 μg mL−1 for SS, BH and ET, respectively. For method 3, LOD values were 0.3297 μg mL−1, 0.2784 μg mL−1 and 0.7906 μg mL−1 and LOQ values were 0.9325 μg mL−1, 0.9282 μg mL−1 and 2.6352 μg mL−1 for SS, BH and ET, respectively. For method 4, LOD values were 0.3161 μg mL−1, 0.2495 μg mL−1 and 0.2064 μg mL−1 and LOQ values were 0.9869 μg mL−1, 0.8317 μg mL−1 and 0.6879 μg mL−1 for SS, BH and ET. The precision values were less then 2% R.S.D. for all four methods. The common excipients and additives did not interfere in their determinations. The results obtained by the proposed methods have been statistically compared by means of Student t-test and by the variance ratio F-test.  相似文献   

5.
Based on CdTe/CdS quantum dots (CdTe/CdS QDs) fluorescence (FL) reversible control, a new and sensitive FL sensor for determination of anthraquinone (AQ) anticancer drugs (adriamycin and daunorubicin) and herring sperm DNA (hsDNA) was developed. Under the experimental conditions, FL of CdTe/CdS QDs can be effectively quenched by AQ anticancer drugs due to the binding of AQ anticancer drugs on the surface of CdTe/CdS QDs and photoinduced electron transfer (PET) process from CdTe/CdS QDs to AQ anticancer drugs. Addition of hsDNA afterwards brought the restoration of CdTe/CdS QDs FL intensity, as AQ anticancer drugs peeled off from the surface of CdTe/CdS QDs and embedded into hsDNA double helix structure. The liner ranges and the detection limits of FL quenching methods for two AQ anticancer drugs were 0.33-9 μg mL−1 and 0.09 μg mL−1 for ADM and 0.15-9 μg mL−1 and 0.04 μg mL−1 for DNR, respectively. The restored FL intensity was proportional to concentration of hsDNA in the range of 1.38-28 μg mL−1and the detection limit for hsDNA was 0.41 μg mL−1. It was applied to the determination of AQ anticancer drugs in human serum and urine samples with satisfactory results. The reaction mechanism of CdTe/CdS QDs FL reversible control was studied.  相似文献   

6.
A DNA-based surface plasmon resonance biosensor for enrofloxacin was developed. Heating denatured DNA immobilized on the gold-coated glass surface was exploited. The immobilization was performed by a layer-by-layer co-deposition with a cationic polymer. The sensor performance was tested with real biological probes. Direct and simple determination of enrofloxacin in milk samples was demonstrated. The sensor response obeys Langmuir binding isotherm being almost linear until about 20 μg mL−1. The detection limit in milk samples was estimated to be 3 μg mL−1.  相似文献   

7.
Multimode reader has been generally applied in immunoassay, and in the proposed paper, the 96 well micro-plate was modified with molecularly imprinted melamine sol-gel film, based on which the highly selective and high throughput detection of melamine was achieved. Melamine was imprinted into silica sol-gel films directly using phenyltrimethoxysilane and methyltrimethoxysilane as functionalized organosilicon precursors. The binding characteristic of the imprinted film to melamine was evaluated by equilibrium binding experiments and the morphology was studied by scanning electronic microscope (SEM). Scatchard analysis was carried out to estimate the binding parameters of the imprinted film. The proposed method exhibited excellent selectivity because of specific recognition of MM by molecularly imprinted film. Under the optimum conditions, the chemiluminescence (CL) intensity had a linear relationship against the concentration of melamine over the range of 0.1-50 μg mL−1 with a lower detection limit of 0.02 μg mL−1.  相似文献   

8.
Y?ld?z Uluda? 《Talanta》2010,82(1):277-383
A simple and sensitive sensor method for cancer biomarkers [prostate specific antigen (PSA) and PSA-alpha 1-antichymotrypsin (ACT) complex] analysis was developed, to be applied directly with human serum (75%) by using antibody modified quartz crystal microbalance sensor and nanoparticles amplification system. A QCM sensor chip consisting of two sensing array enabling the measurement of an active and control binding events simultaneously on the sensor surface was used in this work. The performance of the assay and the sensor was first optimised and characterised in pure buffer conditions before applying to serum samples. Extensive interference to the QCM signal was observed upon the analysis of serum. Different buffer systems were then formulated and tested for the reduction of the non-specific binding of sera proteins on the sensor surface. A PBS buffer containing 200 μg mL−1 BSA, 0.5 M NaCl, 500 μg mL−1 dextran and 0.5% Tween 20, was then selected which eliminated the interfering signal by 98% and enabled the biomarker detection assay to be performed in 75% human serum. By using Au nanoparticles to enhance the QCM sensor signal, a limit of detection of 0.29 ng mL−1 PSA and PSA-ACT complex (in 75% serum) with a linear dynamic detection range up to 150 ng mL−1 was obtained. With the achieved detection limit in serum samples, the developed QCM assay shows a promising technology for cancer biomarker analysis in patient samples.  相似文献   

9.
In this study we propose a chromogenic platform for rapid analysis of organophosphate (OP) and carbamate (CM) insecticide residues, based on recombinant Drosophila melanogaster acetylcholinesterase (R-DmAChE) as enzyme and indoxyl acetate as substrate. The visible chromogenic strip had the advantages identical to those of commonly used lateral flow assays (LFAs) with utmost simplicity in sample loading and result observation. After optimization, depending on the color intensity (CI) values, the well-established assay has the capabilities of both qualitative measurement via naked eyes and quantitative analysis by colorimetric reader with the desirable IC50 values against the tested six insecticides (0.06 μg mL−1 of carbofuran, 0.28 μg mL−1 of methomyl, 0.03 μg mL−1 of dichlorvos, 31.6 μg mL−1 of methamidophos, 2.0 μg mL−1 of monocrotophos, 6.3 μg mL−1 of omethoate). Acceptable matrix effects and satisfactory detection performance were confirmed by in-parallel LC–MS/MS analysis in different vegetable varieties at various spiked levels of 10−3 to 101 μg g−1. Overall, the testified suitability and applicability of this novel platform meet the requirements for practical use in food safety management and environmental monitoring, especially in the developing world.  相似文献   

10.
Zhi Q  Xie C  Huang X  Ren J 《Analytica chimica acta》2007,583(2):217-222
In this paper, we describe a new method for determination of hemoglobin of single red blood cells by coupling chemiluminescence with capillary electrophoresis (CL-CE). The chemiluminescent detection is based on the catalytic effects of hemoglobin on the luminol-hydrogen peroxide reaction. The conditions of chemiluminescent reaction and capillary electrophoresis were investigated. Hemoglobin in human blood samples was detected with the present method, the linear range from 1.7 μg mL−1 to 6.8 μg mL−1 was tested, and the correlation coefficient of 0.997 and low detection limit of 0.17 μg mL−1 (approximately 2.2 pg, S/N = 3) were obtained. Cell injection procedure was improved, and the method was successfully used to determine hemoglobin of single red blood cells and the statistical result of the average content of hemoglobin in 26 human red blood cells was 23.6 pg. Compared to other current methods, CE with CL system is simple, sensitive and will become an attractive alternative method for single cell analysis.  相似文献   

11.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

12.
Liu W  Zhang Z  Liu Z 《Analytica chimica acta》2007,592(2):187-192
In this paper, a chemiluminescence (CL) micro-flow system combined with on-line solid phase extraction (SPE) is presented for determination of β-lactam antibiotics (penicillin, cefradine, cefadroxil, cefalexin) in milk. It is based on the enhancement effect of β-lactam antibiotics on the luminol-K3Fe(CN)6 CL system. The micro-flow system was fabricated from two polymethyl methacrylate (PMMA) plates (50 mm × 40 mm × 5 mm) with the microchannels of 200 μm wide and 150 μm deep. C18-modified silica gel was packed into the microchannel (length: 10 mm; width: 1 mm; depth: 500 μm) to serve as SPE device. Extraction and preconcentration of the analytes were carried out using on-line SPE micro-flow system and the selectivity of CL detection was improved. The detection limits were 0.5 μg mL−1 of penicillin, 0.04 μg mL−1 of cefradine, 0.08 μg mL−1 of cefadroxil and 0.1 μg mL−1 of cefalexin. The proposed method was also applied to analyze the β-lactam antibiotics in milk. Experimental results were in good agreement with those obtained by high performance liquid chromatography (HPLC) method with UV detection.  相似文献   

13.
Pourreza N  Ghomi M 《Talanta》2011,84(1):240-243
A novel simultaneous cloud point extraction method for the determination of carmoisine and brilliant blue FCF by spectrophotometry has been developed. The method is based on the cloud point extraction of carmoisine and brilliant blue FCF from aqueous solution using Triton X-100, diluting the extracted surfactant rich phase with water and measuring the absorbance at 522 and 640 nm for carmoisine and brilliant blue FCF, respectively. The effects of different parameters such as pH, concentration of surfactant and temperature on the cloud point extraction of both dyes were investigated and optimum conditions were established. Linear calibration curves were obtained in the range of 0.02-3.50 μg mL−1 for carmoisine and 0.05-3.50 μg mL−1 for brilliant blue FCF under optimum conditions. Detection limit based on three times the standard deviation of the blank (3Sb) was 0.017 and 0.016 μg mL−1 (n = 10) for carmoisine and brilliant blue FCF, respectively. The relative standard deviation (RSD) for 0.1 μg mL−1 was 4.14 and 3.30% (n = 10), for carmoisine and brilliant blue FCF, respectively. The method was applied to the simultaneous determination of the dyes in different food samples.  相似文献   

14.
A new straightforward method based on cloud-point extraction (CPE) was developed to determine osthole in rat plasma by reversed phase high-performance liquid chromatography with ultraviolet detection using a photodiode array detector. The non-ionic surfactant Triton X-114 was chosen as the extract solvent. Variable parameters affecting the CPE efficiency were evaluated and optimized. A Zorbax SB-C18 column was used for elution separation at 25 °C with detection wavelength at 322 nm. Under the optimum conditions, the method was shown to be reproducible and reliable with intra-day precision below 7.62%, inter-day precision below 6.37%, and accuracy within ±5.02% and mean extraction recovery more than 90.4%, which were all calculated using a range of spiked samples at three concentrations of 0.5, 5.0 and 15.0 μg mL−1 for osthole in plasma. The calibration curve for the analyte was linear in the range from 0.1 to 20 μg mL−1 with the correlation coefficients greater than 0.9981. Limit of detection (S/N = 3) was less than 0.03 μg mL−1and limit of quantification (S/N = 10) was less than 0.1 μg mL−1. After strict validation, the method was successfully applied to the pharmacokinetic study of osthole in rats after oral and intravenous administration, respectively.  相似文献   

15.
Hoogerheide JG  Scott RA 《Talanta》2005,65(2):453-460
A rapid and sensitive method for the determination of alkylating agents in complex reaction mixtures was developed and characterized. Analyses are based on the alkylation of 2-mercaptopyridine by the analyte; the derivative is separated by RP-HPLC and measured by fluorescence detection. When applied to the determination of dimethyl sulfate, the method is linear over four orders of magnitude: 0.01-10 μg mL−1. By using recrystallized 2-mercaptopyridine, quantitation limits of 10 ng mL−1 can be achieved. Precision of the assay is 2% R.S.D. in the 1-10 μg mL−1 range and about 15% R.S.D. at 10 ng mL−1. Studies on the pH dependence of the derivatization reaction were key to minimizing interference from the dimethyl sulfate degradation product, monomethyl sulfate, in quenched reaction samples.  相似文献   

16.
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes (MWCNTs)/Nafion was developed and applied for the extraction of polar aromatic compounds (PACs) in natural water samples. The characteristics and the application of this fiber were investigated. Electron microscope photographs indicated that the MWCNTs/Nafion coating with average thickness of 12.5 μm was homogeneous and porous. The MWCNTs/Nafion coated fiber exhibited higher extraction efficiency towards polar aromatic compounds compared to an 85 μm commercial PA fiber. SPME experimental conditions, such as fiber coating, extraction time, stirring rate, desorption temperature and desorption time, were optimized in order to improve the extraction efficiency. The calibration curves were linear from 0.01 to 10 μg mL−1 for five PACs studied except p-nitroaniline (from 0.005 to 10 μg mL−1) and m-cresol (from 0.001 to 10 μg mL−1), and detection limits were within the range of 0.03–0.57 ng mL−1. Single fiber and fiber-to-fiber reproducibility were less than 7.5 (n = 7) and 10.0% (n = 5), respectively. The recovery of the PACs spiked in natural water samples at 1 μg mL−1 ranged from 83.3 to 106.0%.  相似文献   

17.
Gao L  Wu L  Li Q 《Analytica chimica acta》2008,626(2):174-179
A novel and simple spectrophotometric method for the determination of Captopril with sodium 1,2-naphthoquinone-4-sulfonate is established in this paper. The detailed reaction mechanism is proposed and discussed. It is based on the fact that captopril can catalyze the reaction between sodium 1,2-naphthoquinone-4-sulfonate and hydroxyl ion to form 2-hydroxy-1,4-naphthoquinone in buffer solution of pH 13.00. Beer's law is obeyed in a range of 0.64-80 μg mL−1 at the maximal absorption wavelength of 442 nm. The equation of linear regression is A = 0.05815 + 0.00589C (μg mL−1), with a linear regression correlation coefficient of 0.9981. The detection limit is 0.3 μg mL−1, R.S.D. is 0.77% and the recovery rate is in range of 96.0-103.8%. Furthermore, the method has been validated and successfully applied to the determination of captopril in pharmaceutical samples.  相似文献   

18.
A new reversed-phase high performance liquid chromatography with resonance Rayleigh scattering detection (HPLC-RRS) was developed for simultaneous separation and determination of four tetracycline antibiotics (TCs). A good chromatographic separation among the compounds was achieved using a Synergi Fusion-RP column (150 mm × 4.6 mm; 4 μm) and a mobile phase consisting of methanol-acetonitrile-oxalic acid (5 mM) at the flow rate of 0.8 mL min−1. Column temperature was 30 °C. The RRS signal was detected at λex = λem = 370 nm. The recoveries of sample added standard ranged from 95.3% to 103.5%, and the relative standard deviation was below 2.79%. A detection limit of 2.12-5.12 μg mL−1 was reached and a linear range was found between peak height and concentration in the range of 10.36-518.0 μg mL−1 for oxytetracycline (OTC), 12.11-605.5 μg mL−1 for tetracycline (TC), 11.79-589.5 μg mL−1 for chlortetracycline (CTC) and 10.32-516.0 μg mL−1 for doxycycline (DC). The linear regression coefficients were all above 0.999. The method has been applied successfully to the determination of OTC, TC, CTC, DC in pharmaceutical formulations and in honey. The method was simple, rapid and showed a better linear relation and high repeatability.  相似文献   

19.
A simple and rapid reversed-phase HPLC-UV method was developed for the determination of triterpenic acids in the crude extract of Prunellae Spica. Five triterpenic acids were extracted and isolated from P. Spica as marker compounds for use in the quality control of herbal medicines. Various solvent extraction techniques were evaluated, and the greatest efficiency was observed with sonication in 100% ethanol. Elemental compositions of the five marker compounds were determined by high-resolution mass spectroscopy. The dynamic range of the HPLC-UV method depended on the specific analyte, and acceptable quantitation was obtained between 10 and 250 μg mL−1 for oleanolic acid, between 10 and 300 μg mL−1 for ursolic acid, between 3 and 75 μg mL−1 for 2α,3α,24-trihydroxyolean-12en-28oic acid, between 5 and 100 μg mL−1 for euscaphic acid, and between 5 and 100 μg mL−1 for 2α,3α-dihydroxyurs-12en-28oic acid. The method was deemed satisfactory by inter- and intra-day validation and exhibited both high accuracy and precision (relative standard deviation <9.4%). Overall limits of quantitation and detection were approximately 0.5-2.5 μg mL−1 at a signal-to-noise ratio (S/N) of 3 and were about 3.0-10.0 μg mL−1 at a S/N of 10. In addition, principal component analysis (PCA) was performed on the analytical data of 15 different P. Spica samples in order to classify samples collected from different regions.  相似文献   

20.
An extracting medium based on chitosan–polypyrrole (CS–PPy) magnetic nanocomposite was synthesized by chemical polymerization of pyrrole at the presence of chitosan magnetic nanoparticles (CS-MNPs) for micro-solid phase extraction. In this work, magnetic nanoparticles, the modified CS-MNPs and different types of CS–PPy magnetic nanocomposites were synthesized. Extraction efficiency of the CS–PPy magnetic nanocomposite was compared with the CS-MNPs and Fe3O4 nanoparticles for the determination of naproxen in aqueous samples, via quantification by spectrofluorimetry. The scanning electron microscopy images obtained from all the prepared nanocomposites revealed that the CS–PPy magnetic nanocomposite possess more porous structure. Among different synthesized magnetic nanocomposites, CS–PPy magnetic nanocomposite showed a prominent efficiency. Influencing parameters on the morphology of CS–PPy magnetic nanocomposite such as weight ratio of components was also assayed. In addition, effects of different parameters influencing the extraction efficiency of naproxen including desorption solvent, desorption time, amount of sorbent, ionic strength, sample pH and extraction time were investigated and optimized. Under the optimum condition, a linear calibration curve in the range of 0.04–10 μg mL−1 (R2 = 0.9996) was obtained. The limits of detection (3Sb) and limits of quantification (10Sb) of the method were 0.015 and 0.04 μg mL−1 (n = 3), respectively. The relative standard deviation for water sample spiked with 0.1 μg mL−1 of naproxen was 3% (n = 5) and the absolute recovery was 92%. The applicability of method was extended to the determination of naproxen in tap water, human urine and plasma samples. The relative recovery percentages for these samples were in the range of 56–99%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏