首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper describes a method for the detection and quantification of 38 residues of the most widely used anthelmintics (including 26 veterinary drugs belonging to the benzimidazole, macrocyclic lactone and flukicide classes) in bovine liver using two different protocols for MRL and non-MRL levels. A dual validation approach was adopted to reliably quantify anthelmintic residues over an extended concentration range (1-3000 μg kg−1). Sample extraction and purification was carried out using a modified QuEChERS method. A concentration step was included when analysing in the low μg kg−1 range. Rapid analysis was carried out by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), which was capable of detecting residues to <2 μg kg−1. The method has been single-laboratory validated according to the 2002/657/EC guidelines and met acceptability criteria in all but a few cases. The inclusion of 19 internal standards, including 14 isotopically labelled internal standards, improved accuracy, precision, decision limit (CCα) and detection capability (CCβ).  相似文献   

2.
Fipronil, a phenylpyrazole insecticide introduced for pest control on a broad range of crops, can also affect non-target insects such as honeybees. More widely, non-target environment such as milk produced by dairy cows fed with maize silage from treated seeds (=silage T) can be affected. To assess the potential transfer of fipronil residues (sulfone, sulfide, fipronil, desulfinyl and amide), a methodology including gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) analysis was developed and validated according to the 2002/657/EC decision, in order to reach a level of quantification below 0.1 μg L−1 in milk and 0.1 μg kg−1 in plants. Twelve dairy cows were fed with silage T during 4 months. Concentration of fipronil in treated seeds was estimated at 1 g kg−1, whereas silage from these seeds contained 0.30 ± 0.05 μg kg−1 of dry material of fipronil, 0.13 ± 0.03 μg kg−1 of dry material of sulfone. Sulfide residues were below the limit of quantification. Silage from untreated seeds (=silage U) presented traces of fipronil and sulfone, respectively at 0.04 ± 0.06 and 0.02 ± 0.03 μg kg−1 of dry material. Contribution of fipronil residues from supplies was insignificant. During administration of silage T, only sulfone residues were quantified in milk. The average concentration was 0.14 ± 0.05 μg L−1. Before and after administration, sulfone residues were detected but not quantifiable (<0.025 μg L−1). Our results suggest a transfer of fipronil from feed to milk under its sulfone form. Moreover, traces of fipronil residues in maize U, soya, wheat and straw show a diffuse contamination of this pesticide in the environment.  相似文献   

3.
A high-performance liquid chromatography-fluorescence detection method was optimized and validated to determine tetracyclines residues in bovine milk. Post-column derivatization using metal complexation in non-aqueous reagent increased the fluorescence of chelates by a factor up to 2.54 compared to water (signal-to-noise ratio enhancement). Overall recoveries ranged from 61 to 115%, with RSDr from 5 to 15% (n = 54). Detection limits ranged from 5 to 35 μg kg−1. Limits of quantification were established at 50 μg kg−1. Decision limits (CCα) were 109, 108 and 124 μg kg−1 and detection capabilities (CCβ) 119, 117 and 161 μg kg−1 for oxytetracycline, tetracycline and chlortetracycline, respectively. The method was applied successfully in a national monitoring program.  相似文献   

4.
A new UHPLC–MS/MS (ultra high performance liquid chromatography coupled to tandem mass spectrometry) method was developed and validated to detect 38 anthelmintic drug residues, consisting of benzimidazoles, avermectins and flukicides. A modified QuEChERS-type extraction method was developed with an added concentration step to detect most of the analytes at <1 μg kg−1 levels in milk. Anthelmintic residues were extracted into acetonitrile using magnesium sulphate and sodium chloride to induce liquid–liquid partitioning followed by dispersive solid phase extraction for cleanup. The extract was concentrated into dimethyl sulphoxide, which was used as a keeper to ensure analytes remain in solution. Using rapid polarity switching in electrospray ionisation, a single injection was capable of detecting both positively and negatively charged ions in a 13 min run time. The method was validated at two levels: the unapproved use level and at the maximum residue level (MRL) according to Commission Decision (CD) 2002/657/EC criteria. The decision limit (CCα) of the method was in the range of 0.14–1.9 and 11–123 μg kg−1 for drugs validated at unapproved and MRL levels, respectively. The performance of the method was successfully verified for benzimidazoles and levamisole by participating in a proficiency study.  相似文献   

5.
In this work, a new stir cake sorptive extraction (SCSE) using polymeric ionic liquid monolith as sorbent was prepared. The sorbent was obtained by in situ copolymerization of an ionic liquid, 1-allyl-3-methylimidazolium bis[(trifluoro methyl)sulfonyl]imide (AMII) and divinylbenzene (DB) in the presence of N,N-dimethylformamide. The influence of the content of ionic liquid and the porogen in the polymerization mixture on extraction performance was studied thoroughly. The physicochemical properties of the polymeric ionic liquid were characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. The usefulness of SCSE–AMIIDB was demonstrated by the enrichment of trace benzimidazole anthelmintics. Several parameters affecting the extraction efficiency were investigated, and under the optimized conditions, a simple and effective method for the determination of trace benzimidazoles residues in water, milk and honey samples was established by coupling SCSE–AMIIDB with high performance liquid chromatography/diode array detection (SCSE–AMIIDB–HPLC/DAD). Results indicated that the limits of detection (S/N = 3) for target compounds were 0.020–0.072 μg L−1, 0.035–0.10 μg L−1 and 0.026–0.076 μg L−1 in water, milk and honey samples, respectively. In addition, an acceptable reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations (RSD) of less than 9% and 11%, respectively. Finally, the established AMII–SCSE–HPLC/DAD method was successfully applied for the determination of benzimidazoles residues in milk, honey and environmental water samples. Recoveries obtained for the determination of benzimidazole anthelmintics in spiking samples ranged from 70.2% to 117.6%, with RSD below 12% in all cases.  相似文献   

6.
The β-lactam antibiotics, including penicillins, are the most important antimicrobial substances used for mastitis treatment. Consequently, this is also the most frequently occurring type of antibiotic residues in milk. Today, in addition to the traditional microbial inhibitor tests, rapid and sensitive receptor and immunoassays are used in residue control. Due to the limitations in throughput capacity of these tests, recent applications of automated biosensor technology in food analysis are of great interest.A surface plasmon resonance (SPR)-based biosensor (Biacore) was used to design an inhibition assay to detect β-lactam antibiotics in milk. A microbial receptor protein with carboxypeptidase activity was used as detection molecule. One advantage of using this receptor protein over antibodies that are more commonly used is that only the active, intact β-lactam structure is recognized, whereas most antibodies detect both active and inactive forms. In the presence of β-lactam antibiotics the formation of a stable complex between receptor protein and antibiotic inhibits the enzymatic activity of the protein. The decrease in enzymatic activity was measured using an antibody against the degraded substrate and penicillin G in milk samples was quantitatively determined. The limit of detection of the assay for penicillin G was determined to 2.6 μg kg−1 for antibiotic-free producer milk, which is below the European maximum residue limit (MRL) of 4 μg kg−1. The coefficient of variation at 4 μg kg−1 penicillin G, ranged between 7.3 and 16% on three different days.  相似文献   

7.
A supramolecular solvent consisting of vesicles, made up of equimolecular amounts of decanoic acid (DeA) and tetrabutylammonium decanoate (Bu4NDe), dispersed in a continuous aqueous phase, is proposed for the extraction of benzimidazolic fungicides (BFs) from fruits and vegetables. Carbendazim (CB), thiabendazole (TB) and fuberidazole (FB) were extracted in a single step and no clean-up or concentration of extracts was needed. The high extraction efficiency obtained for BFs was a result of the different types of interactions provided by the supramolecular solvent (e.g. hydrophobic and hydrogen bonds) and the high number of solubilisation sites it contains. Besides simple and efficient, the proposed extraction approach was rapid, low-cost, environment friendly and it was implemented using conventional lab equipments. The target analytes were determined in the supramolecular extract by LC/fluorescence detection. They were separated in a Kromasil C18 (5 μm, 150 mm × 4.6 mm) column using isocratic elution [mobile phase: 60:40 (v/v) 50 mM phosphate buffer (pH 4)/methanol] and quantified at 286/320 nm (CB) and 300/350 nm (TB and FB) excitation/emission wavelengths, respectively. Quantitation limits provided by the supramolecular solvent-based microextraction (SUSME)/LC/fluorescence detection proposed method for the determination of CB, TB and FB in fruits and vegetables were 14.0, 1.3 and 0.03 μg kg−1, respectively, values far below the current maximum residue levels (MRLs) established by the European Union, i.e. 100-2000 μg kg−1 for CB, 50-5000 μg kg−1 for TB and 50 μg kg−1 for FB. The precision of the method, expressed as relative standard deviation, for inter-day measurements (n = 13) was 3.3% for CB (50 μg kg−1), 3.5% for TB (10 μg kg−1) and 2.8% for FB (0.5 μg kg−1) and recoveries for fruits (oranges, tangerines, lemons, limes, grapefruits, apples, pears and bananas) and vegetables (potatoes and lettuces) fortified at the μg kg−1 level were in the interval 93-102%.  相似文献   

8.
An enzyme-linked immunosorbent assay (ELISA) was used for the determination of fenoxycarb in apple leaf samples. Single step extraction procedures with phosphate-citrate buffered solution containing different amounts of methanol were tested showing that a solvent percentage of 20% (v/v) was the best condition, with recoveries between 85 and 100% in the working range of 25-500 μg kg−1 and a negligible matrix effect. The low detection limit reached, 1 μg kg−1 against 50 μg kg−1 for the recommended liquid chromatographic method, makes the ELISA more suitable for determinations of the fenoxycarb residues in apple leaf samples. The reliability of the ELISA was evaluated by assaying the insecticide in spiked and contaminated samples by three different approaches: direct determination, standard addition method with a calibration graph, and the dilution test. The corresponding coefficients of variation were, respectively, 11, 22 and 27%. The direct determination on the (1+1) diluted apple leaf extract was used to measure the insecticide residues in samples collected in the north-eastern Italian regions of Veneto and Trentino-Alto Adige.  相似文献   

9.
Due to the different physico-chemical properties of phenols, the development of a methodology for the simultaneous extraction and determination of phenolic compounds belonging to several families, such as chlorophenols (CPs), alkylphenols (APs), nitrophenols (NTPs) and cresols is difficult. This study shows the development and validation of a method for the analysis of 13 phenolic compounds (including CPs, APs, NTPs and cresols) in agricultural soils. For this purpose, a quick, easy, cheap, effective, rugged and safe (QuEChERS)-based procedure was developed, validated and applied to the analysis of real samples. A derivatization step prior to the final determination by gas chromatography (GC) coupled to a triple quadrupole analyzer operating in tandem mass spectrometry (QqQ-MS/MS) was performed by using acetic acid anhydride (AAA) and pyridine (Py). The optimized procedure was validated, obtaining average extraction recoveries in the range 69–103% (10 μg kg−1), 65–98% (50 μg kg−1), 76–112% (100 μg kg−1) and 76–112% (300 μg kg−1), with precision values (expressed as relative standard deviation, RSD) ≤ 22% (except for 4-chlorophenol) involving intra-day and inter-day studies. Furthermore, 15 real soil samples were analyzed by the proposed method in order to assess its applicability. Some phenolic compounds (e.g. 2,4,6-trichlorophenol or 4-tert-octylphenol) were found in the samples at trace levels (<10 μg kg−1).  相似文献   

10.
A multi-residue method for the determination of organochlorine pesticides in fish feed samples was developed and optimized. The method is based on a cleanup step of the extracted fat, carried out by liquid–liquid extraction on diatomaceous earth cartridge with n-hexane/acetonitrile (80/20, v/v) followed by solid phase extraction (SPE) with silica gel–SCX cartridge, before the identification and quantification of the residues by gas chromatography–triple quadrupole tandem spectrometry (GC–MS/MS). Performance characteristics, such as accuracy, precision, linear range, limits of detection (LOD) and quantification (LOQ), for each pesticide were determined. Instrumental LODs ranged from 0.01 to 0.11 μg L−1, LOQs were in the range of 0.02–0.35 μg L−1, and calibration curves were linear (r2 > 0.999) in the whole range of explored concentrations (5–100 μg L−1). Repeatability values were in the range of 3–15%, evaluated from the relative standard deviation of six samples spiked at 100 μg kg−1 of fat, and in compliance with that derived by the Horwitz's equation. No matrix effects or interfering substances were observed in fish feed analyses. The proposed method allowed high recoveries (92–116%) of spiked extracted fat samples at 100 μg kg−1, and very low LODs (between 0.02 and 0.63 μg kg−1) and LOQs (between 0.05 and 2.09 μg kg−1) determined in fish feed samples.  相似文献   

11.
Streptomycin (STR) and dihydrostreptomycin (DHSTR) are two of the most common aminoglycoside antibiotics used in veterinary medicine. The physicochemical properties of both substances, make their determination challenging. In the present study the development of methods based on ion-pair chromatography (IPC) and on hydrophilic interaction chromatography (HILIC), for the determination of the above mentioned aminoglycosides in the range of 100–1000 μg L−1 is described. The two methods were validated according to EU requirements for residues in food. The recoveries for the IPC method were 69.3% and 56.5% of STR and DHSTR, respectively, and for HILIC method 85.5% and 72.3%, respectively. The intra- and inter-day precision, studied at 100, 200 and 300 μg kg−1 levels in milk samples, gave %RSD ≤ 13 for both methods. LOQs for the HILIC method were 14 μg kg−1 for both analytes and for the IPC method were 109 and 31 μg kg−1, for STR and DHSTR, respectively. The sensitivity of the HILIC method is 80 and 210 times greater than that of the ICP method, for STR and DHSTR, respectively.  相似文献   

12.
13.
This study compared four extraction methods for the simultaneous determination of tetracyclines, macrolides, quinolones, sulphonamides and anthelmintics (including benzimidazoles and avermectins) in eggs by ultra-high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Solvent extraction, solid-phase extraction (SPE), matrix solid-phase dispersion (MSPD) and modified QuEChERS procedure were compared in terms of recovery and number of veterinary drugs extracted. The solvent extraction procedure with a clean-up step provided better results than the other tested procedures. The QuEChERS procedure was simpler and faster, but extracted fewer compounds than solvent extraction. MSPD did not extract tetracyclines and quinolones, whereas macrolides and tetracyclines were not extracted when SPE was applied. The solvent extraction procedure was validated, obtaining recoveries ranging from 60% (sulfaquinoxaline) to 119% (levamisole) with repeatability values (expressed as relative standard deviations, RSDs) lower than 20% at two concentration levels (10 and 100 μg kg−1), except for erythromycin, emamectin and ivermectin that showed RSD values close to 25% at 10 μg kg−1. Limits of quantification (LOQs) were always equal or lower than 5 μg kg−1. Finally the method was applied to egg samples, and erythromycin, enrofloxacin, difloxacin, thiabendazole, emamectin and fenbendazole were detected in four samples.  相似文献   

14.
A relatively fast, simple and very selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the detection of flunixin, its 5-hydroxymetabolite and ketoprofen in raw milk has been developed and validated. After a simple extraction with acetonitrile and partial evaporation of the organic phase, the extract was filtered and directly injected into the LC-MS-MS system on a Symmetry C18 column. The parent ions were selected for further fragmentation with argon. The method developed was partially validated according to Commission Decision 2002/657/EC [Commission Decision 2002/657/EC implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results]. The validation parameters were linearity, specificity, repeatability, recovery and decision limit (CCα). CCα varied from 0.5 μg kg−1 for flunixin and 5-hydroxyflunixin to 1 μg kg−1 for ketoprofen.Holstein-Friesian cows were given either Ketofen® or Finadyne® via an intravenous injection at the maximum dose as written in the instructions. Cows were milked twice a day and all samples were analysed by the method described. The highest concentrations found for ketoprofen, flunixin and 5-hydroxyflunixin were 2.5, 6.7 and 590 μg l−1, respectively. The concentration of 5-hydroxyflunixin declined rapidly to concentrations below the MRL value of 40 μg l−1. It can be concluded that the withdrawal time proposed by the pharmaceutical companies, 12 h after the last dosing, is acceptable for both compounds.  相似文献   

15.
A sensitive and reliable method using capillary HPLC with UV-diode array detection (DAD) has been developed and validated for the trace determination of residues of 10 β-lactam antibiotics of human and veterinary use, in milk, chicken meat and environmental water samples. The analytes included ampicillin, amoxicillin, penicillin V, penicillin G, cloxacillin, oxacillin, dicloxacillin, nafcillin, piperacillin and clavulanic acid. Legal levels are regulated by the EU Council regulation 2377/90 in animal edible tissues for these compounds. For food analysis, a solid-phase extraction (SPE) procedure consisting in a tandem of Oasis HLB and Alumina N cartridges was applied for off-line preconcentration and cleanup. For water analysis, the first step was only necessary. The limits of detection for the studied compounds were between 0.04–0.06 μg l−1 for water samples and 0.80–1.40 μg l−1 (or μg kg−1) in the case of foods derived from animals. Average recoveries for fortified samples at different concentration levels ranged between 82.9% and 98.2%, with relative standard deviations (RSDs) lower than 9%. The method showed the advantages of capillary HPLC for the detection of these widely applied antibiotics in different samples at very low concentration levels.  相似文献   

16.
A simple and sensitive multi-residue method for the determination of 115 veterinary drugs and pharmaceuticals, belonging in more than 20 different classes, in butter, milk powder, egg and fish tissue has been developed. The method involves a simple generic solid–liquid extraction step (solvent extraction, SE) with 0.1% formic acid in aqueous solution of EDTA 0.1% (w/v)–acetonitrile (ACN)–methanol (MeOH) (1:1:1, v/v) with additional ultrasonic-assisted extraction. Precipitation of lipids and proteins was promoted by subjecting the extracts at very low temperature (−23 °C) for 12 h. Further cleanup with hexane ensures fat removal from the matrix. Analysis was performed by liquid chromatography coupled with electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS). Two separate runs were performed for positive and negative ionization in multiple reaction monitoring mode (MRM). Particular attention was devoted to extraction optimization: different sample-to-extracting volume ratios, different concentrations of formic acid in the extraction solvent and different ultrasonic extraction temperatures were tested in butter, egg and milk powder samples. The method was also applied in fish tissue samples. It was validated, on the basis of international guidelines, for all four matrices. Quantitative analysis was performed by means of standard addition calibration. For over 80% of the analytes, the recoveries were between 50% and 120% in all matrices studied, with RSD values in the range of 1–18%. Limits of detection (LODs) and quantification (LOQs) ranged from 0.008 μg kg−1 (oxfendazole in butter) to 3.15 μg kg−1 (hydrochlorthiazide in egg). The evaluated method provides reliable screening, quantification, and identification of 115 veterinary drug and pharmaceutical residues in foods of animal origin and has been successfully applied in real samples.  相似文献   

17.
This paper reports the assessment of the total mercury (T-Hg) and methylmercury (MeHg) contamination of mussel samples collected by two sampling campaigns from along the coastline of Sardinia (Italy). T-Hg has been determined by a direct mercury analyser (DMA) whereas MeHg has been determined by gas chromatography-mass spectrometry (GC-MS) after acid extraction, and employs a novel NaBPh4 derivatization method. The evaluation of the quality of measurements was carried out by analysing candidate certified reference material (CRM) BCR 710, for MeHg and T-Hg, and CRM IAEA-350 for T-Hg. In the analysed samples, the T-Hg concentrations range from 35 to 115 μg kg−1 and from 40 to 830 μg kg−1, for the two sampling campaigns, respectively, whereas the MeHg concentrations range from l5 to 51 μg kg−1 and from 17 to 116 μg kg−1. Consequently, the MeHg/T-Hg ratios range from 0.33 to 0.91 and from 0.14 to 0.98, respectively. Despite the increasing trend of Hg concentration from the first to the second sampling campaign, the T-Hg concentration of all the samples was much below the 0.5 μg g−1 WHO limit, and the MeHg values ranged between 2.2 and 17.2 μg kg−1, not exceeding the 43.5 μg kg−1 tolerable daily residue level calculated for Italy.  相似文献   

18.
A simple and expeditious method based on continuous solid-phase extraction and gas chromatography-mass spectrometry (GC-MS) was reported for the direct determination of 29 organic acids in food and beverages. A sorbent column packed with 80 mg of LiChrolut EN-Supelclean ENVI-18 (1:1) was employed for extraction and clean-up purposes. After elution with 200 μL of methanol, the methanolic extract was directly injected into the GC-MS without prior derivatization. The method provided good linearity (0.5-1000 μg kg−1) and fairly good precision for all compounds (RSD lower than 6.2%). The recoveries of the organic acids from diluted samples that were spiked at three different concentrations (10, 40 and 100 μg kg−1) ranged from 93 to 98%. The applicability of the method was demonstrated by analyzing the target compounds in a wide variety of foodstuffs including beer, wine, fruit juice, soy sauce, soya milk and honey samples.  相似文献   

19.
Semicarbazide (SEM), the marker residue for the banned nitrofuran veterinary antibiotic nitrofurazone (NFZ), has been detected regularly in foods (47% of recent nitrofuran EU Rapid Alerts involve SEM). However, the validity of SEM as a definitive marker for NFZ has been undermined by SEM arising from other sources including azodicarbonamide, a plastics blowing agent and flour treatment additive. An inexpensive screening test for SEM in food matrices is needed—all SEM testing currently uses expensive LC-MS/MS instrumentation. We now report the first production of antibodies against derivatised SEM. A novel carboxyphenyl SEM derivative was used to raise a polyclonal antibody that has been incorporated into a semi-quantitative microtitre plate ELISA, validated according to the criteria set out in Commission Decision 2002/657/EC, for use with chicken muscle. The antibody is highly specific for derivatised SEM, cross-reactivity being 1.7% with NFZ and negligible with a wide range of other nitrofurans and poultry drugs. Samples are derivatised with o-nitrobenzaldehyde and simultaneously protease digested before extraction by cation exchange SPE. The ELISA has a SEM detection capability (CCβ) of 0.25 μg kg−1 when a threshold of 0.21 μg kg−1 is applied to the selection of samples for confirmation (lowest observed 0.25 μg kg−1 fortified sample, n = 20), thus satisfying the EU nitrofurans’ minimum required performance limit of 1 μg kg−1. NFZ-incurred muscles (12) containing SEM at 0.5-5.0 μg kg−1 by LC-MS/MS, all screened positive by this ELISA protocol which is also applicable to egg and chicken liver.  相似文献   

20.
An improved LC-MS/MS method for the determination of semicarbazide in whole egg is described. Waters OASIS-MCX cation exchange purification cartridges increased the sensitivity for analysis by LC-MS/MS. The validation study was carried out according to criteria and requirements of Commission Decision 2002/657/EC for confirmatory analysis and provided the data as follows: The correlation coefficient for the matrix calibration curve, in the range of 0–5 μg kg−1, was r = 0.9968. The detection capability and decision limit, measured according to ISO11843-2, were CCα = 0.20 μg kg−1 and CCβ = 0.25 μg kg−1. Repeatability (CVSr) and within-laboratory reproducibility (CVSwr) determined for the concentration levels of 0.2, 0.5 and 1.0 μg kg−1 SEM ranged from 11.9 to 5.7% and 11.8 to 6.3%, respectively. The validated method was applied to investigate SEM stability in incurred materials (egg homogenates) during long-term storage at −20 °C and 4 °C. The study proved by a two-sampling test that SEM at levels of 17. 7, 1.2, 10.6 and 0.47 μg kg−1 was stable for up to 12 months.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号