A coupled capillary column system was developed for the qualitative and quantitative determination of melamine with isotope internal standard in dairy products by gas chromatography/mass spectrometry (GC/MS) without derivatization. A 30 m of DB-5ms ((5%-phenyl)-methylpolysiloxane, 0.25 mm i.d., 0.25 μm df) coupled with a 1.5 m of Innowax (polyethylene glycol, 0.32 mm i.d., 0.25 μm df) by a quartz capillary column connector was introduced as separation column. Three advantages were discussed for the coupled system. The sample was fortified with a ring-labeled 13C315N3-melamine as an isotope internal standard and extracted by 1% of trichloroacetic acid aqueous solution. 2.2% of lead acetate solution was then added to deposit protein in the sample matrix. After purification by cation exchange cartridge, the sample solution was directly injected and detected by GC/MS. A six-point calibration curve ranging from 0.05 to 2 mg kg−1 of melamine in sample was used to establish instrument response. The recovery was 93.9-102% with relative standard deviation from 3.1 to 8.7% when isotope internal standard used. The calculated method detection limit was 0.01 mg kg−1.  相似文献   

2.
A novel simple, fast and efficient ultra-high performance supercritical fluid chromatography (UHPSFC) method was developed and validated for the separation and quantitative determination of eleven illegal dyes in chili-containing spices. The method involved a simple ultrasound-assisted liquid extraction of illegal compounds with tetrahydrofuran. The separation was performed using a supercritical fluid chromatography system and CSH Fluoro-Phenyl stationary phase at 70 °C. The mobile phase was carbon dioxide and the mixture of methanol:acetonitrile (1:1, v/v) with 2.5% formic acid as an additive at the flow rate 2.0 mL min−1. The UV–vis detection was accomplished at 500 nm for seven compounds and at 420 nm for Sudan Orange G, Butter Yellow, Fast Garnet GBC and Methyl Red due to their maximum of absorbance. All eleven compounds were separated in less than 5 min. The method was successfully validated and applied using three commercial samples of chili-containing spices – Chili sauce (Indonesia), Feferony sauce (Slovakia) and Mojo sauce (Spain). The linearity range of proposed method was 0.50–9.09 mg kg−1 (r ≥ 0.995). The detection limits were determined as signal to noise ratio of 3 and were ranged from 0.15 mg kg−1 to 0.60 mg kg−1 (1.80 mg kg−1 for Fast Garnet) for standard solution and from 0.25 mg kg−1 to 1.00 mg kg−1 (2.50 mg kg−1 for Fast Garnet, 1.50 mg kg−1 for Sudan Red 7B) for chili-containing samples. The recovery values were in the range of 73.5–107.2% and relative standard deviation ranging from 0.1% to 8.2% for within-day precision and from 0.5% to 8.8% for between-day precision. The method showed potential for being used to monitor forbidden dyes in food constituents. The developed UHPSFC method was compared to the UHPLC-UV method. The orthogonality of Sudan dyes separation by these two methods was demonstrated. Benefits and drawbacks were discussed showing the reliability of both methods for monitoring of studied illegal dyes in real food constituents.  相似文献   

3.
Enrichment techniques have become an important feature in the trace analysis of oestrogen mimicking chemicals in the environment. Recent developments such as accelerated solvent extraction (ASE) have improved extraction recoveries in a wide variety of solid matrices including sediments, sludges and leachate soils. Such samples taken from the Irish Midlands Shannon Catchment region during the winter of 2004/5 and suspected to contain certain xenooestrogens or hormonally active agents were extracted using this technique, which was then coupled with high performance liquid chromatography (HPLC) for quantification purposes. ASE was thus employed to both isolate and pre-concentrate targeted analytes using the minimum amount of solvent hence making extractions more conservational. Two simple, yet extremely sensitive liquid chromatographic methods were developed based on UV detection; one for phthalates and one for alkylphenols, with recoveries reaching up to 92.0%. Acid digestion was used for the extraction of the tin and organotin compounds with analysis by polarography. In river sediment, levels of up to 24.4 mg kg−1 phthalate, 1.14 mg kg−1 4-nonylphenol and 118 mg kg−1 tin were found. In leachate sediments, values up to 49.8 mg kg−1 phthalate, 1.57 mg kg−1 4-nonylphenol, and 36.0 mg kg−1 tin were determined. In sludge, values up to 174 mg kg−1 phthalate and 22.8 mg kg−1 4-nonylphenol were quantified. The highest value of tin (118 mg kg−1) was found present in an area of high leisure craft activity. Typical sediment levels of tin at other river locations ranged between 1.20 and 37.5 mg kg−1.  相似文献   

4.
In this study, a capillary electrochromatography (CEC) method coupled either with UV or mass spectrometric detection was developed for the detection of trace-amounts of melamine and its related by-products (ammeline, ammelide, and cyanuric acid). A series of poly(divinyl benzene-alkene-vinylbenzyl trimethylammonium chloride) monolithic columns, which were prepared by a simple in situ polymerization with divinyl benzene (DVB), vinylbenzyl trimethylammonium chloride (VBTA) and different types of alkene monomers such as 1-octene, 1-dodecene or 1-octadecene were used as separation columns, with the poly(DVB-1-dodecene-VBTA) monolith as the optimal chromatographic material because it provided a better separation. The detection limits of four melamine derivatives were in the ranged of 0.6–2.18 mg L−1 by the optimal CEC–UV mode, and were reduced from 2.2 to 19.4 μg L−1 by the optimal CEC–MS mode. Finally, the proposed CEC methods successfully determined melamine contaminations (0.1 mg L−1 per analyte) in several dairy products as test samples with analyte recovery range of 69–85% (intra-day) and 68–75% (inter-day), and with peak area reproducibility range of 4.3–8.6% and 8.7–15.6% for intra-day and inter-day, respectively. This is the first report for CEC separation coupled with MS detection applied in trace melamine residue analyses with a faster separation and comparable or even better detection ability than previous GC–MS, CE–MS, as well as LC–MS methods.  相似文献   

5.
A wide-scope screening method was developed for the detection of pesticides in fruit and vegetables. The method was based on gas chromatography coupled to a hybrid quadrupole time-of-flight mass spectrometer with an atmospheric pressure chemical ionization source (GC-(APCI)QTOF MS). A non-target acquisition was performed through two alternating scan events: one at low collision energy and another at a higher collision energy ramp (MSE). In this way, both protonated molecule and/or molecular ion together with fragment ions were obtained in a single run. Validation was performed according to SANCO/12571/2013 by analysing 20 samples (10 different commodities in duplicate), fortified with a test set of 132 pesticides at 0.01, 0.05 and 0.20 mg kg−1. For screening, the detection was based on one diagnostic ion (in most cases the protonated molecule). Overall, at the 0.01 mg kg−1 level, 89% of the 2620 fortifications made were detected. The screening detection limit for individual pesticides was 0.01 mg kg−1 for 77% of the pesticides investigated. The possibilities for identification according to the SANCO criteria, requiring two ions with a mass accuracy ≤±5 ppm and an ion-ratio deviation ≤±30%, were investigated. At the 0.01 mg kg−1 level, identification was possible for 70% of the pesticides detected during screening. This increased to 87% and 93% at the 0.05 and 0.20 mg kg−1 level, respectively. Insufficient sensitivity for the second ion was the main reason for the inability to identify detected pesticides, followed by deviations in mass accuracy and ion ratios.  相似文献   

6.
This paper describes selenium determination based on Se0 preconcentration in the imprinted polymer (synthesized with 2.25 mmol SeO2, 4-vinylpyridine and 1-vinylimidazole) with subsequent detection on-line in HG-FAAS. During the synthesis, SeO2 is reduced to Se (0). Therefore, there are no MIP neither IIP in the present work, thus we denominated: AIP, i.e., atomically imprinted polymers. For the optimization of analytical parameters Doehlert design was used. The method presented limit of detection and limit of quantification of 53 and 177 ng L−1, respectively, and linear range from 0.17 up to 6 μg L−1 (r = 0.9936). The preconcentration factor (PF), consumptive index (CI) and concentration efficiency (CE) were 232; 0.06 mL and 58 min−1 respectively. The proposed method was successfully applied to determine Se in Brazil nuts (0.33 ± 0.03 mg kg−1), apricot (0.46 ± 0.02 mg kg−1), white bean (0.47 ± 0.03 mg kg−1), rice flour (0.47 ± 0.02 mg kg−1) and milk powder (0.22 ± 0.01 mg kg−1) samples. It was possible to do 12 analyzes per hour. Accuracy was checked and confirmed by analyzing certified reference material (DORM-2, dogfish muscle), and samples precision was satisfactory with RSD lower than 10%.  相似文献   

7.
The concentrations of Cu, Zn, Mn, Fe, K, Ca, Mg, Al, Ba and B in 26 herbal drugs of special importance in phytopharmacy were studied. Flame atomic absorption and emission spectrometry (FAAS, FAES), as well as inductively coupled plasma atomic emission spectrometry (ICP-AES), were applied in this work. The whole procedure, from sample preparation, via dissolution, to measurements, was validated by using CRM (NIST 1573a—tomato leaves), and the obtained recovery values are in the range from 91 to 102%. Drug samples originated from medicinal plants cultivated in Serbia contained Cu (4.47-14.08 mg kg−1), Zn (8.4-54.5 mg kg−1), Mn (9-155 mg kg−1), Fe (47-546 mg kg−1), K (0.20-6.24%), Ca (0.18-1.84%), Mg (0.13-1.09%), Al (16-416 mg kg−1), Ba (11.70-84.83 mg kg−1) and B (5.1-118.7 mg kg−1). In order to get a better insight into the elemental patterns, a common chemometric approach to data evaluation was used. Four significant factors identified by principal component analysis (PCA) were attributed partly to the significant influential sources and high mobility of some elements thus referring to potential anthropogenic contamination as well.  相似文献   

8.
A liquid chromatographic (LC) atmospheric pressure chemical ionization mass spectrometric (MS) method is described for determining imidacloprid, carbendazim, methiocarb and hexythiazox in peaches and nectarines. The samples were extracted with ethyl acetate and anhydrous sodium sulfate. Recoveries yield for spiking samples were ranged from 64±9% (R.S.D) for carbendazim to 108±14% (R.S.D.) for hexythiazox at the concentration of 0.1 mg kg−1 (n=5). The correlation coefficients were greater than 0.998 over the range between 0.02 and 2 mg kg−1. The limits of quantitation (LOQ) were 0.02 mg kg−1 for all the pesticides. The applicability of the method to detect and quantify imidacloprid, carbendazim, methiocarb and hexythiazox was demonstrated successfully in 159 peach and nectarine samples obtained from an agricultural co-operative. The calculation of the estimated daily intakes (EDI) from these data showed that contribution of fruits to dietary intakes were much lower than acceptable daily intakes (ADI) proposed by international agencies.  相似文献   

9.
Cadmium and iron are antagonistic elements in the sense that they produce different effects in the human body. Both elements have to be determined routinely in grain products, cadmium because of its toxicity, and iron because all grain products, according to Brazilian law, have to contain a minimum of 42 mg kg−1 Fe to combat anemia. A routine screening method has been developed for the quasi simultaneous determination of cadmium and iron using high-resolution continuum source electrothermal atomic absorption spectrometry and direct solid sampling. The primary absorption line at 228.802 nm has been used for Cd, and an adjacent secondary line at 228.726 nm for the determination of Fe. Various chemical modifiers have been investigated, and a mixture of tungsten and iridium, applied as a permanent modifier, showed the best performance; it stabilized Cd up to a pyrolysis temperature of 700 °C and did not over-stabilize Fe. Two atomization temperatures were used sequentially, 1700 °C for Cd and 2600 °C for Fe, because of their significantly different volatilities. The characteristic masses obtained were 0.9 pg for Cd and 1.2 ng for Fe. The limits of detection (3σ, n = 10) were 0.6 μg kg−1 for Cd and 0.5 mg kg−1 for Fe. The relative standard deviation ranged from 3 to 7% for Cd and from 4 to 13% for Fe, which is satisfactory for the purpose. The accuracy of the method was confirmed by the analysis of three certified reference materials; the results were in agreement with the certified values at a 95% confidence interval. The Cd content in the investigated grain products was between 0.9 and 10.5 μg kg−1, but most of them did not contain the required minimum amount of iron.  相似文献   

10.
Mineral content and botanical origin of Spanish honeys   总被引:2,自引:0,他引:2  
Eleven elements (Zn, P, B, Mn, Mg, Cu, Ca, Ba, Sr, Na and K) were determined by inductively plasma coupled spectrometry in 40 honey samples from different places of Spain and four different botanical origins: Eucalyptus (Eucalyptus sp.), Heather (Erica sp.), Orange-blossom (Citrus sinensis) and Rosemary (Rosmarinus officinalis). K, Ca and P show the higher levels with average concentrations ranged between 434.1-1935 mg kg−1 for K; 42.59-341.0 mg kg−1 for Ca and 51.17-154.3 mg kg−1 for P. Levels of Cu (0.531-2.117 mg kg−1), Ba (0.106-1.264 mg kg−1) and Sr (0.257-1.462 mg kg−1) are the lowest in all honey samples. Zn (1.332-7.825 mg kg−1), Mn (0.133-9.471 mg kg−1), Mg (13.26-74.38 mg kg−1) and Na (11.69-218.5 mg kg−1) concentrations were found strongly dependent on the kind of botanical origin.Results were submitted to pattern recognition procedures, unsupervised methods such as cluster and principal components analysis and supervised learning methods like linear discriminant analysis in order to evaluate the existence of data patterns and the possibility of differentiation of Spanish honeys from different botanical origins according to their mineral content. Cluster analysis shows four clusters corresponding to the four botanical origins of honey and PCA explained 71% of the variance with the first two PC variables. The best-grouped honeys were those from heather; eucalyptus honeys formed a more dispersed group and finally orange-blossom and rosemary honeys formed a less distinguishable group.  相似文献   

11.
An evaluation of the extraction of pesticides from onion by matrix solid-phase dispersion (MSPD) with the determination by liquid chromatography tandem mass spectrometry using electrospray as the ionization source (LC-ESI-MS/MS) was carried out. The performance of different sorbents, including reused C18 bonded silica, was evaluated. Different parameters affecting the extraction efficiency were evaluated, such as the type and amount of sorbent, the time of interaction after the fortification step, the time of sample dispersion and the elution solvent. The matrix effect regarding the recovery of the pesticides by MSPD was also investigated. The best results were obtained using 0.5 g of sample, 1.0 g reused C18, interaction time of 1 h, dispersion time of 5 min, and acetonitrile as the elution solvent. The method was validated by the fortification of the onion sample, free of pesticides, at different concentration levels (0.01, 0.1 and 1.0 mg kg−1). Average recoveries ranged from 78.3 to 120.4% and relative standard deviation below 20% was obtained. Detection and quantification limits ranged from 0.003 to 0.03 mg kg−1 and from 0.01 to 0.1 mg kg−1, respectively.  相似文献   

12.
A method was developed for determination of methylmercury and estimation of total mercury in seafood. Mercury (Hg) compounds were extracted from 0.5 g edible seafood or 0.2 g lyophilized reference material by adding 50 ml aqueous 1% w/v l-cysteine·HCl·H2O and heating 120 min at 60 °C in glass vials. Hg compounds in 50 μl of filtered extract were separated by reversed-phase high performance liquid chromatography using a C-18 column and aqueous 0.1% w/v l-cysteine·HCl·H2O + 0.1% w/v l-cysteine mobile phase at room temperature and were detected by inductively coupled plasma-mass spectrometry at mass-to-charge ratio 202. Total Hg was calculated as the mathematical sum of methyl and inorganic Hg determined in extracts. For seafoods containing 0.055-2.78 mg kg−1 methylmercury and 0.014-0.137 mg kg−1 inorganic Hg, precision of analyses was ≤5% relative standard deviation (R.S.D.) for methylmercury and ≤9% R.S.D. for inorganic Hg. Recovery of added analyte was 94% for methylmercury and 98% for inorganic Hg. Methyl and total Hg results for reference materials agreed with certified values. Limits of quantitation were 0.007 mg kg−1 methylmercury and 0.005 mg kg−1 inorganic Hg in edible seafood and 0.017 mg kg−1 methylmercury and 0.012 mg kg−1 inorganic Hg in lyophilized reference materials. Evaluation of analyte stability demonstrated that l-cysteine both stabilized and de-alkylated methylmercury, depending on holding time and cysteine concentration. Polypropylene adversely affected methylmercury stability. Total Hg results determined by this method were equivalent to results determined independently by cold vapour-atomic absorption spectrometry. Methylmercury was the predominant form of Hg in finfish. Ratios of methylmercury/total Hg determined by this method were 93-98% for finfish and 38-48% for mollusks.  相似文献   

13.
A reversed-phase high performance liquid chromatographic method for the successful separation and determination of 13 synthetic food colorants (Tartrazine E 102, Quinoline Yellow E 104, Sunset Yellow E 110, Carmoisine E 122, Amaranth E 123, Ponceau 4R E 124, Erythrosine E 127, Red 2G E 128, Allura Red AC E 129, Patent Blue V E 131, Indigo Carmine E 132, Brilliant Blue FCF E 133 and Green S E 142) was developed. A C18 stationary phase was used and the mobile phase contained an acetonitrile-methanol (20:80 v/v) mixture and a 1% (m/v) ammonium acetate buffer solution at pH 7.5. Successful separation was obtained for all the compounds using an optimized gradient elution within 29 min. The diode-array detector was used to monitor the colorants between 350 and 800 nm. The method was thoroughly validated. Detection limits for all substances varied between 1.59 (E 142) and 22.1 (E 124) μg L−1. The intra-day precision (as R.S.D.r) ranged from 0.37% (E 122 in fruit flavored drink at a concentration of 100 mg L−1) to 4.8% (E 142 in icing sugar at a level of 0.9 mg kg−1). The inter-day precision (as R.S.D.R) was between 0.86% for E 122 in fruit flavored drink at 100 mg L−1 and 10% for E142 in jam at a concentration of 9 mg kg−1. Satisfactory recoveries, ranging from 94% (E 142 in jam) to 102% (E 131 in sweets), were obtained. The method was applied to the determination of colorants in various water-soluble foods, such as fruit flavoured drinks, alcoholic drinks, jams, sugar confectionery and sweets, with simple pre-treatment (dilution or water extraction).  相似文献   

14.
In this work, a new rapid method for the determination of 135 pesticide residues in green and black dry tea leaves and stalks employing gas chromatography coupled to tandem mass spectrometry (GC–MS/MS) with a triple quadrupole was developed and validated. A substantial simplification of sample processing prior to the quantification step was achieved: after addition of water to a homogenised sample, transfer of analytes into an acetonitrile layer was aided by the addition of inorganic salts. Bulk co-extracts, contained in the crude organic extract obtained by partition, were subsequently removed by liquid–liquid extraction using hexane with the assistance of added 20% (w/w) aqueous NaCl solution. The importance of matrix hydration prior to the extraction for achieving good recoveries was demonstrated on tea samples with incurred pesticide residues. For most of the analytes, recoveries in the acceptable range of 70–120% and repeatabilities (relative standard deviations, RSDs) ≤20% were achieved for both matrices at spiking levels of 0.01, 0.1 and 1 mg kg−1. Under optimised GC–MS/MS conditions, most of the analytes gave lowest calibration level ≤0.01 mg kg−1, permitting the control at the maximum residue levels (MRLs) laid down in Regulation (EC) No 396/2005. The developed method was successfully applied to the determination of pesticide residues in real tea samples.  相似文献   

15.
A sensitive and efficient solid-phase microextraction (SPME) method for the determination of seven pyrethroid insecticides including fenpropathrin, λ-cyhalothrin, deltamethrin, fenvalerate, permethrin, τ-fluvalinate and bifenthrin in cucumber and watermelon samples using high performance liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection (SPME-HPLC-PIF-FD) was developed and validated. The optimum SPME conditions were used for the extraction of samples of both matrices (extraction time 30 min, stirring rate 1100 rpm, extraction temperature 65 °C, sample pH 3, soaking time 7 min, desorption time 5 min, ACN content 25%, desorption and soaking solvent was the mobile phase and in static mode). The method was validated in terms of limits of detection (LODs) and the limits of quantification (LOQs) in both IUPAC and EURACHEM criteria. LODs and LOQs were achieved in values lower than the maximum residue levels (MRLs) established in the Spanish regulations for all pesticides in this study (MRLs range between 0.01 and 0.1 mg kg−1 for all pyrethroid insecticides in both matrices). LOQs according to the second criterion were between 1.5 and 5 μg kg−1 for cucumber; and between 1.3 and 5 μg kg−1 for watermelon samples. Precision and recovery studies were evaluated at two concentration levels for each matrix. Good precision was obtained and relative standard deviation values were less than 10% in all cases. Recovery values were calculated at 0.05 and 0.5 mg kg−1 levels (n = 6) and they ranged between 93% and 108% for cucumber and between 91% and 110% for watermelon samples. Applicability of the method to pyrethroids in cucumber and watermelon of commercial samples was demonstrated.  相似文献   

16.
The migration of melamine monomers from food contact materials has aroused particular attention since the 2008 melamine-tainted milk scandal in China. However, the determination of melamine monomer’s migratory quantity (MMMQ) has remained an open question because of the complex sample pretreatment and the low sensitivity. Based on the hydrogen bonding interaction between DNA thymine and melamine, this paper described a simple and rapid method focusing on the measurement of MMMQ from melamine tableware by gold nanoparticles (GNPs) and dynamic light scattering (DLS). With the presence of probe DNA (p-DNA), the GNPs were stable in NaCl solution (0.06 M), whereas they became aggregated when the p-DNA hybridized with melamine. The change in the hydrodynamic diameter of GNPs could be detected by DLS technology. Under the optimal conditions, the average diameter increased linearly with the concentration of melamine over the range from 5.0 to 320.0 μg L−1, and showed a detection limit of 2.0 μg  L−1 (3σ/slope). The MMMQ was investigated within a range from 6.00 × 10−4 to 2.58 × 10−1 mg dm−2 (n ≥ 3) in four different food simulants at different temperatures and time points. The results suggest that the DLS method has great potential in the analysis of the migration of melamine monomers.  相似文献   

17.
A rapid and sensitive method has been developed for the simultaneous detection of cyromazine and melamine in chicken eggs using the quick, easy, cheap, effective, rugged and safe (QuEChERS) method coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS). The optimal extraction solvent for the liquid–liquid extraction was 5 mL of acetonitrile with a 0.1 M hydrochloric acid aqueous solution (99.5:0.5, v/v). The extract was cleaned with 0.5 g of anhydrous magnesium sulfate and 10 mg of graphitized carbon black. The analysis of cyromazine and melamine was accomplished by combining the use of an anion exchange LC column with tandem mass spectrometry in the positive electrospray ionization mode with selected reaction monitoring mode (SRM). The detection limits were 1.6 ng g−1 for cyromazine and 8 ng g−1 for melamine, and the quantitation limits were 5.5 ng g−1 for cyromazine and 25 ng g−1 for melamine. The recoveries of cyromazine and melamine in the spiked egg samples were 83.2% and 104.6%, respectively, with an relative standard deviation (RSD) of less than 18.1%. The intra-day and inter-day precisions, represented by the RSD, ranged from 1.5% to 8.8% and 6.8% to 14.3%, respectively. The proposed method was tested by analyzing chicken eggs from the markets and from the veterinary medicine laboratory. The concentrations of cyromazine and melamine detected in these samples were in the range of 20–94 ng g−1. The results demonstrated that the QuEChERS method combined with LC–MS/MS is a simple, rapid and inexpensive method for the analysis of cyromazine and melamine in eggs.  相似文献   

18.
A simple chiral high-performance liquid chromatography (HPLC) method with ultraviolet (UV) and circular dichroism (CD) detection was developed and validated for measuring benalaxyl enantiomers using (R,R) Whelk-O 1 column. The effects of mobile phase composition and column temperature on the entioseparation were investigated. A CD detector was used to determine the elution order of the enantiomers. Excellent resolution was easily obtained using n-hexane-polar organic alcohols mobile phase. The chiral recognition mechanism was also discussed. Based on the developed chiral HPLC method, enantioselective analysis methods for this fungicide in environment matrix (soil and water) were developed and validated. Good linearities were obtained over the concentration range of 0.25-25 mg L−1 for both enantiomers. Liquid-liquid extraction and solid phase extraction (SPE) were used for the enrichment and cleanup of soil and water samples. Recoveries for the two enantiomers were 79-91% at 0.02, 0.04 and 0.2 mg kg−1 levels from soil, and 89-101% at 0.0025, 0.01 and 0.05 mg L−1 levels from water. Run-to-run and day-to-day assay precisions were below 10% for both enantiomers at concentrations of 0.5, 1 and 5 mg L−1. Individual detection limits of the two enantiomers were both 2 ng. Limits of detection (LOD) were 0.004 mg kg−1 in soil and 0.001 mg L−1 in water.  相似文献   

19.
The study proposes an analytical method to quantify 10 alkylphenols and 12 pesticides at ultra-trace levels by liquid chromatography in reverse mode coupled to positive electrospray ionisation–tandem mass spectrometry. The extraction procedure from environmental solids was optimised by pressurised liquid extraction using acetonitrile:isopropanol (1:1, v/v). The influence of several extraction experimental factors, temperature, pressure, duration and number of cycles, related to the PLE was investigated by an original and efficient chemometric approach. The optimised extraction method (80 °C, 40 bar, 10 min, 1 cycle) exhibited recoveries between 67 and 127% with RSD mostly under 13%. The whole method was applied to real samples: sludge, suspended materials, atmospheric fallouts and roof deposit. Pollutant levels were between 1 μg kg−1 and 5.9 mg kg−1.  相似文献   

20.
J. López Flores 《Talanta》2007,72(3):991-997
A novel flow-through solid phase spectroscopic assembly implemented with photochemically induced fluorescence (PIF) has been developed for the rapid, sensitive and selective determination of imidacloprid. The pesticide is derivatized on-line by irradiation with ultraviolet light providing an intensively fluorescent compound. The determination is carried out by measuring the fluorescence intensity of the photoproduct once retained on C18 silica gel filling the flow-cell. The method proposed has been applied to the determination of imidacloprid in natural waters and peppers. The quantification limit (QL) (0.015 mg kg−1) in peppers was lower than the maximum residue limit (MRL) established by Spanish Legislation (0.5 mg kg−1). The method also seems to be suitable for environmental water analysis providing satisfactory recoveries (94.0-108.6%). The results obtained in the analysis of real samples are in good agreement with those provided by a reference liquid chromatography (HPLC) method.  相似文献   