首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Trace metals play an important role in the regulation of primary productivity and phytoplankton community composition. Metal species directly affects the biogeochemical cycling processes, transport, fate, bioavailability and toxicity of trace metals. Therefore, developing powerful methods for metal speciation analysis is very useful for research in a range of fields, including chemical and environmental analysis. Voltammetric methods, such as anodic stripping voltammetry (ASV) and competing ligand exchange-adsorptive cathodic stripping voltammetry (CLE-AdCSV), have been widely adopted for speciation analysis of metals in different natural aquatic systems. This paper provides an overview of the theory of voltammetric methods and their application for metal speciation analysis in natural waters, with a particular focus on current voltammetric methods for the discrimination of labile/inert fractions, redox species and covalently bound species. Speciation analysis of typical trace metals in natural waters including Fe, Cu, Zn, Cd, and Pb are presented and discussed in detail, with future perspectives for metal speciation analysis using voltammetric methods also discussed. This review can elaborate the particular knowledge of theory, merits, application and future challenge of voltammetric methods for speciation analysis of trace metals in natural waters.  相似文献   

2.
This article discusses the degradation of methyl parathion (MP) in natural and sterilized waters. Experiments were prepared using natural waters gathered in two aquatic systems (Rio de Janeiro State, Brazil), ultra-pure water and humic water solution under different conditions (i.e. in the presence/absence of light, sterilized/no sterilize solutions). The exposition to sunlight was carried out using experimental bottles without headspace immersed in a swimming pool for temperature control. Natural waters results showed that the degradation kinetic of MP is of first order and the half-lives for lake water experiments, under direct sunlight and shade, were 4.41 and 6.89 days, respectively. The kinetic curve for MP degradation in river waters showed that there are no differences when samples were sterilized and placed (or not) under shade conditions, and the half-lives ranged from 5.37 to 2.75 days for sterilized river water/absence of sunlight and natural/presence of sunlight, respectively. Therefore, our results showed that photolysis plays, in addition to bio- and chemical degradation, an important role in the decomposition of MP in aquatic environments.  相似文献   

3.
Size exclusion chromatography was used in order to characterize organically bound aluminium in natural water samples. A Superose column was used, with 0.1 M acetate buffer (pH 4.6) as mobile phase. Three detection systems were used; graphite furnace atomic absorption spectrometry, post-column reaction with pyrocatechol violet and UV spectrometry at 254 nm. A single peak was obtained for organic aluminium in natural waters. The results indicated that aluminium binds with a broad size range of humic substances, and that the inorganic aluminium was present in polymeric form.  相似文献   

4.
The aim of this paper is to introduce a virtual special issue that reviews the development of analytical approaches to the determination of phosphorus species in natural waters. The focus is on sampling and sample treatment, analytical methods and quality assurance of the data. The export of phosphorus from anthropogenic activities (from diffuse and point sources) can result in increased primary production and eutrophication, and potentially the seasonal development of toxic algal blooms, which can significantly impact on water quality. Therefore the quantification of phosphorus species in natural waters provides important baseline data for studying aquatic phosphorus biogeochemistry, assessing ecosystem health and monitoring compliance with legislation.  相似文献   

5.
A simple and sensitive multicommutated flow procedure, implemented by employing a homemade light emitting diode (LED) based photometer, has been developed for the determination of chromium (VI) and total chromium in water. The flow system comprised a set of four solenoid micro-pumps, which were assembled to work as fluid propelling and as commutating devices. The core of the detection unit comprised a green LED source, a photodiode and a homemade flow cell of 100 mm length and 2 mm inner diameter. The photometric procedure for the speciation of chromium in natural waters was based on the reaction of Cr (VI) with 1,5-diphenylcarbazide. Cr (III) was previously oxidized to Cr (VI) and determined as the difference between total Cr and Cr (VI). After carrying out the assays to select the best operational conditions the features of the method included: a linear response ranging from 10 to 200 μg l−1 Cr (III) and Cr (VI) (r = 0.999, n = 7); limits of detection of 2.05 and 1.0 μg l−1 for Cr (III) and Cr (VI), respectively; a relative standard deviation lower than 2.0% (n = 20) for a typical solution containing 50 μg l−1 Cr; a sampling throughput of 67 and 105 determinations per hour for total Cr and Cr (VI), respectively, and recovery values within the range of 93-108% for spiked concentrations of the order of 50 μg l−1.  相似文献   

6.
Studies on nitrogen in natural waters have generally focussed on dissolved inorganic nitrogen (DIN), primarily because of relative ease of analysis and the important influence of DIN on water quality. Advances in analytical techniques now permit the systematic study of dissolved organic nitrogen (DON), and this work has shown that DON is quantitatively significant in many waters. This article describes the sampling and analytical protocols required for rapid, precise and reliable determinations of DON, involving high-temperature catalytic oxidation (HTCO), coupled to chemiluminescence detection. This approach simultaneously determines dissolved organic carbon (DOC) and total dissolved nitrogen (TDN), and DON is derived by subtraction of DIN measured by colorimetry. The DON determination is simple to perform, exhibits excellent precision (<1% for C and 1.5% for N) and is applicable to a wide range of natural waters.  相似文献   

7.
There is a need for simple and inexpensive methods to quantify potentially harmful persistent pesticides often found in our water-ways and water distribution systems. This paper presents a simple, relatively inexpensive method for the detection of a group of commonly used pesticides (atrazine, simazine and hexazinone) in natural waters using large-volume direct injection high performance liquid chromatography (HPLC) utilizing a monolithic column and a single wavelength ultraviolet-visible light (UV-vis) detector. The best results for this system were obtained with a mobile phase made up of acetonitrile and water in a 30:70 ratio, a flow rate of 2.0 mL min−1, and a detector wavelength of 230 nm. Using this method, we achieved retention times of less than three minutes, and detection limits of 5.7 μg L−1 for atrazine, 4.7 μg L−1 for simazine and 4.0 μg L−1 for hexazinone. The performance of this method was validated with an inter-laboratory trial against a National Association of Testing Authorities (NATA) accredited liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) method commonly used in commercial laboratories.  相似文献   

8.
The determination of calcium and total hardness in natural waters is carried out with a potentiometric sensor array which consists of a series of ion-selective electrodes (ISEs) for Ca2+, Mg2+, NH4+, K+, Na+, Li+, and H+. The selectivity of the calcium and magnesium ISEs is not fully achieved as other cation species may interfere with the analysis. The proposed sensor array device can overcome this drawback since it can take advantage of the cross-selectivities of cation species towards each ISE. In this approach, the multivariate data generated by the sensor array results in a richer source of analytical information which allows the quantification of calcium and total hardness in the water samples by means of chemometric methods. Results obtained are in reasonable concordance with those given by the standard method based on complexometry.  相似文献   

9.
In this work multifunctional sorbents, based on surfactant-coated mineral oxides, are assessed for the simultaneous extraction/preconcentration of pesticide multiresidues from aqueous environmental samples. Seventeen pesticides, representative of all the common groups (triazines, phenylureas, carbamates, azols, anilides, chloroacetanilides, organophosphorous, phenoxyacids, aryloxy acids and phenols), are selected for this study. The sorbents assessed are pure sodium dodecyl sulphate (SDS) and mixed tetrabutylammonium (TBA)-SDS hemimicelles and/or admicelles adsorbed onto alumina. Because of their multifunctional character, these sorbents provide different retention mechanisms (i.e. hydrophobic, ionic and/or π-cation interactions), which highly contribute to the efficient retention of pesticides with different polarities and acidities (bases, neutrals and acids). In addition, the low volume of eluent required for complete elution of analytes (typically 1-2 mL) avoided the need of using time-consuming and tedious evaporation steps that generally are needed when cross-linked polymeric resins or carbon materials are used as sorbents. The performance of two sorbents, i.e. SDS and TBA-SDS mixed hemimicelles/admicelles, for the admicellar solid-phase extraction (ASPE) of pesticide multiresidue was comparatively investigated. The latter was selected on the basis of the higher breakthrough volumes permitted, the lower volume of eluent required and the higher sample and eluent flow rates allowed. The proposed ASPE/LC/UV approach provided detection limits lower than 100 ng L−1 for the determination of the 17 pesticides tested. Recoveries from spiked (at the ng L−1 level) river and underground water samples was quantitative for most of the pesticides tested.  相似文献   

10.
The utility of multivariate optimization methods in the determination of aqueous photolysis rates of organic compounds is examined in this study. A basic pursue was to designate the appropriate experimental design plan that extend the analytical utility of multivariate methods from qualitative data interpretation approaches, as applied thus far, to quantitative estimation methods. A three-level second-order central composite design with parameter concentrations (factor levels) beyond the environmental realistic concentrations was employed for that purpose enabling statistically significant effects to be determined. Method application is demonstrated in the first photodegradation study of two UV absorbing chemicals in natural waters. The results suggest that the proposed approach of enables a good approximation of the real behavior in terms of both qualitative and quantitative data interpretation with minimal loss of information.  相似文献   

11.
12.
Phosphorus is an important macronutrient and the accurate determination of phosphorus species in environmental matrices such as natural waters and soils is essential for understanding the biogeochemical cycling of the element, studying its role in ecosystem health and monitoring compliance with legislation. This paper provides a critical review of sample collection, storage and treatment procedures for the determination of phosphorus species in environmental matrices. Issues such as phosphorus speciation, the molybdenum blue method, digestion procedures for organic phosphorus species, choice of model compounds for analytical studies, quality assurance and the availability of environmental CRMs for phosphate are also discussed in detail.  相似文献   

13.
Inorganic mercury and methylmercury are determined in natural waters by injecting the filtered samples onto a low cost commercial flow injection system in which an anion exchange microcolumn is inserted after the injection loop (FIA-IE). If hydrochloric acid is used as the carrier solution, the HgCl4(2-) species (inorganic mercury) will be retained by the anion exchanger while the CH3HgCI species (methylmercury) will flow through the resin with negligible retention. Four anion exchangers and seven elution agents were checked, in a batch mode, to search for the best conditions for optimal separation and elution of both species. Dowex M-41 and L-cysteine were finally selected. Mercury detection was performed by cold vapour-electrothermal atomic adsorption spectrometry (HG-ETAAS). Both systems were coupled to perform the continuous on-line separation/detection of both inorganic mercury and methylmercury species. Separation and detection conditions were optimized by two chemometric approaches: full factorial design and central composite design. A limit of detection of 0.4 microg L(-1) was obtained for both mercury species (RSD < 3.0% for 20 microg L(-1) inorganic and methylmercury solutions). The method was applied to mercury speciation in natural waters of the Nerbioi-lbaizabal estuary (Bilbao, North of Spain) and recoveries of more than 95% were obtained.  相似文献   

14.
Whilst there is increasing evidence for the presence of stabilized FeII associated with organic matter in aquatic environments, the absence of a reliable method for determining FeII speciation in solution has inhibited the study of this aspect of Fe biogeochemistry. A technique is described here for the determination of FeII organic complexation in natural waters that is based on competitive ligand reverse titration and a model fit to experimental results, from which ligand concentration and a conditional stability constant can be obtained. Spectrophotometry was used to detect the Ferrozine (FZ) complex with reactive FeII, which in combination with a liquid waveguide capillary cell (LWCC) enabled high sensitivity and precision measurements of FeII to be made. A series of samples was collected in the Itchen River in Southampton, UK to test the method at a wide range of salinities including river water. Levels of FeII and total dissolved Fe were within previously reported values for this system. FeII was found to occur organically complexed with values for log KFeIILlogKFeIIL (conditional stability constant for FeII-natural ligand complexes) of ≈8 at salinities between 0 and 21, whilst no measurable complexation was detected at a salinity of 31. This work demonstrates that spectrophotometry can be used in combination with ligand competition to investigate metal speciation in natural waters.  相似文献   

15.
Kinetic speciation of uranium in model solutions containing uranium and humic acid (HA) and in natural waters has been investigated by Competitive Ligand Exchange Method (CLEM). In alkaline freshwaters, most of uranium species were uranium-carbonate species, which were labile in the CLEM experiment. The uranium speciation of every sample was characterized either as “labile” or “non-labile” uranium complexes depending on the dissociation rate coefficients of the complexes. The results showed that as the U(VI)/HA ratio was decreased, the dissociation rate coefficients decreased and the labile fraction decreased as well. When the U(VI)/HA ratio was 0.1, the labile fraction of the U(VI)-HA increased with increasing pH; however, there was no pH effect on the dissociation of U(VI)-HA complexes at lower U(VI)/HA ratios. Chelex-100 had some limitations in its use for the study of dissociation of U(VI)-HA complex at very low U(VI)/HA ratios. By developing an analytical method and procedure for quantitative determination of kinetic parameters for the dissociation of uranium-HA complexes in model solutions and natural waters, this work has made a substantial contribution to analytical chemistry.  相似文献   

16.
A basic research has been carried out using four probes to develop an electronic tongue able to discriminate three different kinds of natural waters, i.e. rain, river and groundwater. Several natural water samples were analysed to this purpose using a pH glass electrode, a digital (thermistor) thermometer, an amperometric gaseous diffusion oxygen sensor for measuring the dissolved oxygen and a direct methanol fuel cell enzymatic probe for measuring the concentration of alcoholic traces. Data were processed by means of principal component analysis, obtaining three well differentiated clusters, that demonstrate how the use of only four different sensors can discriminate in an inexpensive and effective way three different classes of natural waters.  相似文献   

17.
Nontargeted analysis of water samples using liquid chromatography combined with high-resolution mass spectrometers is an emerging approach for surface water monitoring and evaluation of water treatment processes. In this study, sample preconcentration via direct, large volume injection with 500 μL and 1000 μL injection volumes was compared to SPE regarding analytical performance parameters in targeted and nontargeted workflows. In targeted analysis, the methods were evaluated in terms of LOD and intrabatch precision of the selected compounds, whereas in nontargeted analysis, the number of detected unknown compounds, the method's intra-batch precision, and the retention time versus molecular mass pattern of the detected unknowns were evaluated. In addition, a novel intensity drift correction method was developed that is not based on quality control samples and makes use of the signals obtained for continuously infused reference compounds, which are conventionally utilized for online mass drift correction. It could be demonstrated that the new correction method significantly reduced the bias introduced by instrumental drift and is important for the reliable intercomparison of different nontargeted methods. Intercomparison of results showed that the 1000 μL large volume injection method revealed the best performance in terms of precision under repeatability conditions of measurement as well as lower LODs for targeted compound analysis. In nontargeted analysis, the SPE method detected a higher number of unknown compounds but exhibited also a higher uncertainty of measurement caused by matrix effects.  相似文献   

18.
ABSTRACT

Application of an electric potential to hollow fibre liquid phase microextraction (HF-LPME) systems previously optimised for metals preconcentration from natural waters could improve their analytical performance increasing enrichment factors and reducing operation times. Nevertheless, the effectiveness of the direct application of an electric potential to these systems may be limited due to the effects produced by other operational parameters.

In this work, the effect of a variable electric potential on the enrichment factors of four HF-LPME systems used for the analysis of trace metals in natural waters (Cd, Ni, Ag and Cu) has been studied. In addition, the effect of organic phase composition, distance between electrodes and electrodes diameter has been also studied. From the results obtained, composition of organic phase can be considered as the key factor in electromembrane (EME) systems, since its polarity determine the operational range of the applied electric potential and consequently the enrichment factor that could be achieved.

EMEs have demonstrated to be a real alternative to preconcentrate Cd, Ag and Cu from natural water samples in very short times (30 min). In fact, enrichment factors increased up to one order of magnitude if compared with HF-LPME methodology without application of an electrical potential.  相似文献   

19.
Three adsorbents (Chelex-100, manganese dioxide [MnO2] and Metsorb), used as binding layers with the diffusive gradient in thin film (DGT) technique, were evaluated for the measurement of inorganic uranium species in synthetic and natural waters. Uranium (U) was found to be quantitatively accumulated in solution (10–100 μg L−1) by all three adsorbents (uptake efficiencies of 80–99%) with elution efficiencies of 80% (Chelex-100), 84% (MnO2) and 83% (Metsorb). Consistent uptake occurred over pH (5–9), with only MnO2 affected by pH < 5, and ionic strength (0.001–1 mol L−1 NaNO3) ranges typical of natural waters, including seawater. DGT validation experiments (5 days) gave linear mass uptake over time (R2 ≥ 0.97) for all three adsorbents in low ionic strength solution (0.01 M NaNO3). Validation experiments in artificial sea water gave linear mass uptake for Metsorb (R2 ≥ 0.9954) up to 12 h and MnO2 (R2 ≥ 0.9259) up to 24 h. Chelex-100 demonstrated no linear mass uptake in artificial sea water after 8 h. Possible interferences were investigated with SO42− (0.02–200 mg L−1) having little affect on any of the three DGT binding layers. PO43− additions (5 μg L−1–5 mg L−1) interfered by forming anionic uranyl phosphate complexes that Chelex-100 was unable to accumulate, or by directly competing with the uranyl species for binding sites, as with MnO2 and the Metsorb. HCO3 (0.1–500 mg L−1) additions formed anionic species which interfered with the performance of the Chelex-100 and the MnO2, and the Ca2+ (0.1–500 mg L−1) had the affect of forming labile calcium uranyl species which aided uptake of U by all three resins. DGT field deployments in sea water (Southampton Water, UK) gave a linear mass uptake of U over time with Metsorb and MnO2 (4 days). Field deployments in fresh water (River Lambourn, UK) gave linear uptake for up to 7 and 4 days for Metsorb and MnO2 respectively. Field deployment of the Metsorb-DGT samplers with various diffusive layer thicknesses (0.015–0.175 cm) allowed accurate measurements of the diffusive boundary layer (DBL) and allowed DBL corrected concentrations to be determined. This DBL-corrected U concentration was half that determined when the effect of the DBL was not considered. The ability of the DGT devices to measure U isotopic ratios with no isotopic fractionation was shown by all three resins, thereby proving the usefulness of the technique for environmental monitoring purposes.  相似文献   

20.
The development and evaluation of a portable flow analysis system for the in situ determination of total phosphorus is described. The system has been designed with rapid underway monitoring in mind. The system employs an ultra-violet photo-reactor and thermal heating for peroxodisulfate digestion of total phosphorus to orthophosphate, followed by spectrophotometric detection with a multi-reflective flow cell and low-power light emitting diode using the molybdenum blue method. Reagents are stored under gas pressure and delivered using software controlled miniature solenoid valves. The fully automated system has a throughput of 115 measurements per hour, a detection limit of 1 μg P L−1, and gives a linear response over the calibration range of 0-200 μg P L−1 (r2 = 0.9998), with a precision of 4.6% RSD at 100 μg P L−1 (n = 10). Field validation of the instrument and method was performed in Port Philip and Western Port Bays in Victoria, SE Australia, where 2499 analyses were performed over a 25 h period, over a cruise path of 285 km. Good agreement was observed between determinations of samples taken manually and analysed in the laboratory and those measured in situ with the flow analysis system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号