首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
With fast separation times (seconds to minutes), minimal sample requirements (nanoliters to femtoliters), and excellent mass detection limits (femtomole to zeptomole), capillary electrophoresis (CE) is ideally suited for in vitro and in vivo sampling of neurological samples with a high degree of spatial resolution. Advances in extracellular fluid analysis employing improved microdialysis and push–pull perfusion sampling methodologies has enabled the resolution of neurotransmitters present in limited amounts using CE. Great progress has been made to resolve complex neuropeptides, amino acids, and biogenic amines in tissue and cell cultures. Finally, owing largely to the small volume sampling abilities of CE, investigations of single nerve cells, both invertebrate and mammalian, have been accomplished. These applications of CE to the advancement of neuroscience are presented.  相似文献   

2.
Microdialysis (MD) is a sampling technique that can be employed to monitor biological events both in vivo and in vitro. When it is coupled to an analytical system, microdialysis can provide near real-time information on the time-dependent concentration changes of analytes in the extracellular space or other aqueous environments. Online systems for the analysis of microdialysis samples enable fast, selective and sensitive analysis while preserving the temporal information. Analytical methods employed for online analysis include liquid chromatography (LC), capillary (CE) and microchip electrophoresis and flow-through biosensor devices. This review article provides an overview of microdialysis sampling and online analysis systems with emphasis on in vivo analysis. Factors that affect the frequency of analysis and, hence, the temporal resolution of these systems are also discussed.  相似文献   

3.
《Analytical letters》2012,45(7):1044-1069
Neurotransmitters are important biological molecules that are essential to many neurophysiological processes including memory, cognition, and behavioral states. The development of analytical methodologies to accurately detect neurotransmitters is of great importance in neurological and biological research. Specifically designed microelectrodes or microbiosensors have demonstrated potential for rapid, real-time measurements with high spatial resolution. Such devices can facilitate study of the role and mechanism of action of neurotransmitters and can find potential uses in biomedicine. This paper reviews the current status and recent advances in the development and application of electrochemical sensors for the detection of neurotransmitters. Measurement challenges and opportunities of electroanalytical methods to advance study and understanding of neurotransmitters in various biological models and disease conditions are discussed.  相似文献   

4.
The nanoscale interface between two immiscible electrolyte solutions (nanoITIES) is an emerging versatile analytical platform. Analytical advantages of chemical analysis using the nanoITIES include imaging with nanometer spatial resolution, probing fast dynamics with millisecond temporal resolution and fast response times, selectively detecting analytes, probing fundamental chemical processes (e.g., diffusion profiles), and versatile sensing of metal ions, proteins, neurotransmitters, ionic and neutral species, redox-active and non-redox active analytes, etc. We present here a brief theoretical background of the nanoITIES and experimental advances from the past five years. These advances include imaging of nanopores, probing diffusion profiles, biosensing, a new pH modulation mechanism for sensing neutral species, and studying exocytosis from Aplysia californica neurons.  相似文献   

5.
L-Glutamate is a major amino acid neurotransmitter in the central neuronal system of the mammalian brain and plays a vital role in brain development, synaptic plasticity, neurotoxicity, and neuropathological disorders. Despite technical limitations, progress is being made in sensing L-glutamate in vivo and in vitro. Sophisticated microsensors with the necessary spatial and temporal resolution have recently been emerging, which enable us to discern regional distribution, concentration levels, and temporal changes of L-glutamate in acute brain slices. The L-glutamate sensors for in vitro sensing have different structures and sizes, such as glass capillary-based enzyme sensors, polymer-coated enzyme sensors, and patch sensors based on natural sensing probes. The concentration of L-glutamate released in brain slices by chemical stimulation is markedly dependent on neuronal regions, types of stimulation, and sensing methods. Real- and long-time monitoring of L-glutamate in acute hippocampal slices is beginning to shed light on L-glutamate release related to the molecular mechanisms of long-term potentiation. Progress is also being made toward the visualization of L-glutamate release in acute hippocampal slices. The methodological aspects of in vitro sensing of L-glutamate are discussed.  相似文献   

6.
A PDMS‐based microfluidic system for online coupling of microdialysis sampling to microchip electrophoresis with fluorescence detection for in vivo analysis of amino acid neurotransmitters using naphthalene‐2,3‐dicarboxaldehyde and sodium cyanide as the derivatization reagents is described. Fabricating chips from PDMS rather than glass was found to be simpler and more reproducible, especially for chips with complex designs. The microchip incorporated a 20‐cm serpentine channel in which sample plugs were introduced using a “simple” injection scheme; this made fluid handling and injection on‐chip easier for the online system compared with gated or valve‐based injection. The microchip was evaluated offline for the analysis of amino acid standards and rat brain microdialysis samples. Next, precolumn derivatization was incorporated into the chip and in vivo online microdialysis‐microchip electrophoresis studies were performed. The system was employed for the continuous monitoring of amino acid neurotransmitters in the extracellular fluid of the brain of an anesthetized rat. Fluorescein was dosed intravenously and monitored simultaneously online as a marker of in vivo blood–brain barrier permeability. The microdialysis‐microchip electrophoresis system described here will be employed in the future for simultaneous monitoring of changes in blood–brain barrier permeability and levels of amino acid neurotransmitters in the rat stroke model.  相似文献   

7.
Technology always has been an indispensible part in the development of biosensors. The performance of biosensors is being tremendously improved using new materials as transducer as well as binding material in their construction. The use of new materials allowed innovation on transduction technology in biosensor preparations. Because of the submicron dimensions of these sensors, simple and rapid analyses in vitro as well as in vivo are now possible. Portable instruments capable of analysing multiple components are becoming available, too. Sensors that provide excellent temporal and spatial resolution for in vivo monitoring such as for measurement of neurotransmitters have become prominent. The interest to improve the stability, sensitivity and selectivity of the sensors is paramount. This study tries to give an overview of the present status of the material-based biosensor design and new generation of choline/acetylcholine neurotransmitter biosensors.  相似文献   

8.
Vibrational spectroscopy has proven itself to be a valuable contributor in the study of various fields of science, primarily due to the extraordinary versatility of sampling methods. Raman measurement gives the vibrational spectrum of the analyte, which can be treated as its “fingerprint,” allows easy interpretation and identification. Over the last years, there has been tremendous technical improvement in Raman spectroscopy, as overcome by the problems like fluorescence, poor sensitivity or reproducibility. This article reviews the recent advances in Raman spectroscopy and its new trend of applications ranging from ancient archaeology to advanced nanotechnology. It includes the aspects of Raman spectroscopic measurements to the analysis of various substances categorized into distinct application areas such as biotechnology, mineralogy, environmental monitoring, food and beverages, forensic science, medical and clinical chemistry, diagnostics, pharmaceutical, material science, surface analysis, etc. Advances in the instrumental design of Raman spectrometers coupled with newly developed sampling methodologies have also been described which enable trace level detection and satisfactory analysis.  相似文献   

9.
In vivo monitoring of neurochemicals is important for exploring the mechanism and function of the central nervous system. In vivo electrochemical microsensor benefiting from high temporal and spatial resolution has been demonstrated to be one effective strategy for neurochemical detection. However, due to the complex biological environment, microsensor faces huge challenges in sensitivity, selectivity, stability, and biocompatibility. Materials with good electron-transfer, rough surface, and easy functionalization are widely used to enhance the performance of microsensor. In this review, we summarize the recent progress in improving the performance of in vivo electrochemical microsensor based on materials.  相似文献   

10.
Organic phosphate biomolecules (OPBs) are indispensable components of eukaryotes and prokaryotes, such as acting as the fundamental components of cell membranes and important substrates for nucleic acids. They play pivotal roles in various biological processes, such as energy conservation, metabolism, and signal modulation. Due to the difficulty of detection caused by variety OPBs, investigation of their respective physiological effects in organisms has been restrained by the lack of efficient tools. Many small fluorescent probes have been employed for selective detection and monitoring of OPBs in vitro or in vivo due to the advantages of tailored properties, biodegradability and in situ high temporal and spatial resolution imaging. In this review, we summarize the recent advances in fluorescent probes for OPBs, such as nucleotides, NAD(P)H, FAD/FMN and PS. Importantly, we describe their identification mechanisms in detail and discuss the general strategies for these OPBs probe designs, which provide new insights and ideas for the future probe designs.  相似文献   

11.
Dai N  Kool ET 《Chemical Society reviews》2011,40(12):5756-5770
Fluorescent sensors that make use of DNA structures have become widely useful in monitoring enzymatic activities. Early studies focused primarily on enzymes that naturally use DNA or RNA as the substrate. However, recent advances in molecular design have enabled the development of nucleic acid sensors for a wider range of functions, including enzymes that do not normally bind DNA or RNA. Nucleic acid sensors present some potential advantages over classical small-molecule sensors, including water solubility and ease of synthesis. An overview of the multiple strategies under recent development is presented in this critical review, and expected future developments in microarrays, single molecule analysis, and in vivo sensing are discussed (160 references).  相似文献   

12.
Ion transport has been widely used for various applications such as sensing, desalination and energy conversion; however, nearly all applications are based on steady-state ion transport. Herein, we for the first time demonstrate the capability of transient ion transport for in vivo sensing with both high spatial (∼μm) and temporal (∼ms) resolution by using pH as the model target. Transient ion transport behavior (i.e., time-dependent ion current change) was observed by applying high-frequency pulse potential. Importantly, we proposed the ion distribution transient model for this time-dependent ion transport behavior. With this model, the temporal resolution of the as-developed pH microsensor based on ion current was improved to the ms level, thus satisfying the requirement of neurochemical recording. Moreover, our microsensor features good reproducibility, selectivity, and reversibility, and can thus real-time monitor the pH change in living rat brains. This study demonstrates the first example of in vivo sensing based on ion transport, opening a new way to neurochemical monitoring with ultrahigh spatiotemporal resolution. This study is also helpful to understand the transient process of asymmetric ion transport.

Micrometer-scale transient ion transport has been successfully used for constructing a high spatiotemporal resolution and performance microsensor, which could be used for real-time monitoring the change of pH in rat brains.  相似文献   

13.
Mass spectrometry has emerged as a powerful tool for the bioanalytical sciences because of its ability to characterize small and large biomolecules in vanishingly small amounts. A recurring motif in mass spectrometry aims to decipher the chemical composition of biological samples at the molecular level, requiring drastic improvements in the ability to interrogate well defined and highly spatially resolved areas of a sample surface. With the growth of novel ionization methods, numerous advances have been made in sampling biological tissue surfaces. Here, current advancements in ambient, inlet, and vacuum ionization methods are discussed with respect to the potential improvements in the goal of achieving high spatial resolution and/or fast surface analysis. Of similar importance is the need for improvements in applicable characterization strategies using high performance fragmentation technologies such as electron transfer dissociation and electron capture dissociation directly from surfaces, and gas-phase separation through ion mobility spectrometry and high resolution mass spectrometry.
Figure
?  相似文献   

14.
Solid-phase microextraction (SPME) has been demonstrated to be useful for in vivo sampling in pharmacokinetic studies. In this study, a single time-point kinetic calibration for in vivo dynamic monitoring was developed by simplification of the laborious multiple time-point kinetic calibration, based on the independent desorption kinetics of the preloaded standards from SPME fibers with the changing analyte concentrations. The theoretical foundation and practical application conditions, such as the replicate numbers, the optimal time-point for desorption, and the sampling time, were systematically investigated. Furthermore, the feasibility of using regular standards rather than deuterated ones for the kinetic calibration was justified by comparing to the data obtained using the deuterated standards. All the methods were verified by in vitro and in vivo experiments. The results from in vivo SPME were validated by the blood drawing and chemical assay. These simplified calibration methods improved the quantitative applications of SPME for dynamic monitoring and in vivo sampling, enhance the multiplexing capability and automatic potentials for high throughput analysis, and decrease expenses on reagents and instruments.  相似文献   

15.
细胞是生物体形态结构和生命活动的基本单位.常规检测群体细胞的方法往往会掩盖细胞间的个体差异,因此亟需发展高效的单细胞分析策略,深入研究细胞生命活动过程,揭示疾病发生发展机制,推动个体化诊疗.超微电化学传感器具有尺寸小、灵敏度高、时空分辨率高等特点,在单细胞实时动态监测方面发挥了非常重要的作用.目前,微纳电化学传感器在电...  相似文献   

16.
Controlling chemistry in space and time has offered scientists and engineers powerful tools for research and technology. For example, on-demand photo-triggered activation of neurotransmitters has revolutionized neuroscience. Non-invasive control of the availability of bioactive molecules in living organisms will undoubtedly lead to major advances; however, this requires the development of photosystems that efficiently respond to regions of the electromagnetic spectrum that innocuously penetrate tissue. To this end, we have developed a polymer that photochemically degrades upon absorption of one photon of visible light and demonstrated its potential for medical applications. Particles formulated from this polymer release molecular cargo in vitro and in vivo upon irradiation with blue visible light through a photoexpansile swelling mechanism.  相似文献   

17.
The primary objective of this review is to discuss recent technological developments in the field of solid-phase microextraction that have enhanced the utility of this sample preparation technique in the field of bioanalysis. These developments include introduction of various new biocompatible coating phases suitable for bioanalysis, such as commercial prototype in vivo SPME devices, as well as the development of sampling interfaces that extend the use of this methodology to small animals such as mice. These new devices permit application of in vivo SPME to a variety of analyses, including pharmacokinetics, bioaccumulation and metabolomics studies, with good temporal and spatial resolution. New calibration approaches have also been introduced to facilitate in vivo studies and provide fast and quantitative results without the need to achieve equilibrium. In combination with the drastic improvement in the analytical sensitivity of modern liquid chromatography–tandem mass spectrometry instrumentation, full potential of in vivo SPME as a sample preparation tool in life sciences can finally be explored. From the instrumentation perspective, SPME was successfully automated in 96-well format for the first time. This opens up new opportunities for high-throughput applications (>1000 samples/day) such as for the determination of unbound and total drug concentrations in complex matrices such as whole blood with no need for sample pretreatment, studies of distribution of drugs in various compartments and/or determination of plasma protein binding and other ligand–receptor binding studies, and this review will summarize the progress in this research area to date.  相似文献   

18.
The unique electronic properties and miniaturized dimensions of silicon nanowires (SiNWs) are attractive for label-free, real-time and sensitive detection of biomolecules. Sensors based on SiNWs operate as field effect transistors (FETs) and can be fabricated either by top–down or bottom–up approaches. Advances in fabrication methods have allowed for the control of physicochemical and electronic properties of SiNWs, providing opportunity for interfacing of SiNW-FET probes with intracellular environments. The Debye screening length is an important consideration that determines the performance and detection limits of SiNW-FET sensors, especially at physiologically relevant conditions of ionic strength (>100 mM). In this review, we discuss the construction and application of SiNW-FET sensors for detection of ions, nucleic acids and protein markers. Advantages and disadvantages of the top–down and bottom–up approaches for synthesis of SiNWs are discussed. An overview of various methods for surface functionalization of SiNWs for immobilization of selective chemistry is provided in the context of impact on the analytical performance of SiNW-FET sensors. In addition to in vitro examples, an overview of the progress of use of SiNW-FET sensors for ex vivo studies is also presented. This review concludes with a discussion of the future prospects of SiNW-FET sensors.  相似文献   

19.
A new analytical method has been developed for direct analysis of solid samples of airborne particulate matter by a graphite probe collection technique coupled with graphite furnace atomic absorption spectrometry. A porous graphite probe is used as a filter for air particles. The probe is then subjected to atomization by being inserted into a graphite furnace which has been pre-heated to a constant atomization temperature. Some aspects of the method have been tested by recovery studies using NBS Urban Particulate Matter, SR M No. 1648, and found to give recoveries of 91–107% for Pb, Cd, Ni, Cu and Mn. By combining a highly efficient filtering medium with the extremely high relative sensitivity of solid sampling, this method has the potential of monitoring sources of air particulate emission with sufficient temporal and spatial resolution for unequivocal identification of the pollution source (at least on a local scale).  相似文献   

20.
Optochemical Nanosensors and Subcellular Applications in Living Cells   总被引:1,自引:0,他引:1  
What may be the smallest anthropogenic devices to date, spherical sensors (wireless and fiberless) with radii as small as 10?nm have been produced. This class of optochemical PEBBLE (Probe Encapsulated By Biologically Localized Embedding) sensors covers a wide range of analytes (pH, calcium, oxygen and potassium included here) with excellent spatial, temporal and chemical resolution. Examples of such sensors for the monitoring of intracellular analytes are given. Methods, such as pico-injection, liposomal delivery and gene gun bombardment, are used to inject PEBBLE sensors into single cells. These PEBBLEs have caused minimal perturbation when delivered and operated inside single mammalian cells, such as human neuroblastoma, mouse oocytes or rat alveolar macrophage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号