首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Accurate determination of concentration of immunoglobulin (IgG) to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, immune competence in individual patients and to measure the prevalence of immunity in populations. Surface modified polyacrylonitrile (PAN) fibers were evaluated as a matrix to develop highly sensitive method for the detection of anti-tetanus antibody in a sandwich ELISA format. In the proposed method tetanus toxoid immobilized on modified PAN fibers was used to detect anti-tetanus antibody (raised in horse hence represented as horse anti-tetanus toxoid or HAT-Ab) with horse raddish peroxidase enzyme conjugated with Rabbit anti-Horse IgG (RAH-HRP) as the label within 2.5 h. A sigmoidal pattern for the detection of different concentration of antibody ranging from 1.0 to 0.0001 IU mL−1 was validated. The immunoassay recorded a very high sensitivity as concentration as low as 0.0005 IU mL−1 of HAT-Ab was detected. The intra- and inter-assay precision for 3 parallel measurements of 0.01 and for 0.001 IU mL−1 of antibody varied from 5.4% to 11% and 5.7% to 20% respectively. PAN fibers were also used to qualitatively access the presence of different level of anti-tetanus antibody spiked in human blood. Seroepidemiological studies to measure the immunity against tetanus were conducted with twenty-five human beings belonging to various age groups using modified PAN-ELISA. The sensitivity, specificity and the reproducibility of the developed immunoassay indicate the potential application of modified PAN fibers in the field of immunodiagnostics.  相似文献   

2.
Generic simple and sensitive universal enzyme immunoassay approach for the determination of small analytes has been developed to avert the problems associated with small molecule immobilization onto solid phases. The developed assay employed a heterogeneous non-competitive binding format. The assay used anti-analyte antibody coupled to polyacrylamide beads as a solid-phase and β-d-galactosidase enzyme-labeled analyte as a label. In this assay, the analyte in a sample was firstly incubated to react with an excess of the antibody-coupled beads, and then the unoccupied antibody binding sites were allowed to react with the enzyme-labeled analyte. Analyte bound to the antibody-coupled beads was separated by centrifugation, and the enzyme activity of the supernatant was measured spectrophotometrically at 420 nm, after reaction with 4-nitrophenyl-β-d-galactopyranoside as a substrate for the enzyme. The signal was directly proportional to the concentration of analyte in the sample. The optimum conditions for the developed assay were established and applied to the determination of tobramycin, as a representative example of the small analytes, in serum samples. The assay limit of detection was 10 ng mL−1 and the effective working range at relative standard deviation of ≤10% was 40-800 ng mL−1. The assay precisions were acceptable; the relative standard deviations were 4.36-5.17 and 5.62-7.40% for intra- and inter-assay precision, respectively. Analytical recovery of tobramycin spiked in serum ranged from 95.89 ± 4.25 to 103.45 ± 4.60%. The assay results correlated well with those obtained by high-performance liquid chromatography (r = 0.992). The assay described herein has great practical value in determination of small analytes because it is sensitive, rapid, and easy to perform in any laboratory. Although the assay was validated for tobramycin, however, it is also anticipated that the same methodology could be used for essentially any analyte for which a selective antibody exists, and an appropriate enzyme conjugate can be made.  相似文献   

3.
Development of a chemiluminescent immunosensor for chloramphenicol   总被引:3,自引:0,他引:3  
A direct competitive chemiluminescent immunosensor system that exploits the competition between chloramphenicol (CAP) as an analyte and CAP-horseradish peroxidase conjugate as a tracer for binding to an anti-CAP antibody on a solid support was devised by installing a flow-through cell which was connected to an injector and a peristaltic pump inside a dark box, followed by positioning a photomultiplier tube as light detector in front of it. The anti-CAP antibody was immobilized onto positively charged Biodyne B membrane pieces by a dipping procedure. The operating conditions for the immunosensor were selected with respect to substrate composition (0.25, 13.3 and 0.66 mM for luminol, H2O2 and p-iodophenol, respectively), injection volume of the substrate solution (200 μL) and the concentrations of antibody for immobilization (0.10 mg mL−1) and tracer (0.030 mg mL−1). At these conditions, sensor response according to analyte concentration was well fitted to a linear equation when plotted in semi-logarithmic scale, with the limit of detection for CAP of 10−8 M. By using the immunosensor, CAP measurement in the model samples prepared from five food materials was conducted.  相似文献   

4.
This study reports a novel, simple and sensitive immunoassay using fluorescence quenching caused by gold nanoparticles coated with antibody. The method is based on a non-competitive heterogeneous immunoassay of human IgG conducted by the typical procedure of sandwich immunocomplex formation. Goat anti-human IgG was first adsorbed on polystyrene microwells, and human IgG analyte was captured by the primary antibody and then sandwiched by antibody labeled with gold nanoparticles. The sandwich-type immunocomplex was subsequently dissociated by the mixed solution of sodium hydroxide and trisodium citrate, the solution obtained, which contains gold nanoparticles coated with antibody, was used to quench fluorescence. The fluorescence intensity of fluorescein at 517 nm was inversely proportional to the logarithm of the concentration of human IgG in the dynamic range of 10-5000 ng mL−1 with a detection limit of 4.7 ng mL−1. The electrochemical experiments and the UV-vis measurements were applied to demonstrate whether the immunoglod was dissociated completely and whether the gold nanoparticles aggregated after being dissociated, respectively. The proposed system can be extended to detect target molecules such as other kinds of antigen and DNA strands, and has broad potential applications in disease diagnosis.  相似文献   

5.
A novel progesterone immunosensor using a colloidal gold-graphite-Teflon-tyrosinase composite biosensor as amperometric transducer is reported. A sequential competitive configuration between the analyte and progesterone labelled with alkaline phosphatase (AP) was used. Phenyl phosphate was employed as the AP-substrate and the enzyme reaction product, phenol, was oxidized by tyrosinase to o-quinone, which is subsequently reduced at −0.1 V at the biocomposite electrode. Variables such as the concentration of phenyl phosphate, the amount of antibody attached to the electrode surface, immersion time in a 2% BSA solution, working pH and incubation times in progesterone and AP conjugate were optimized. A linear calibration graph for progesterone was obtained between 0 and 40 ng mL−1 with a slope value of −82.3 nA ng−1 mL, and a detection limit of 0.43 ng mL−1. The time needed to reach the steady-state current from the addition of phenyl phosphate was 30-40 s. These analytical characteristics improve substantially those reported for other progesterone immunosensors. A lifetime of 14 days with no need to apply any regeneration procedure was also achieved. The usefulness of the immunosensor was evaluated by determining progesterone in milk samples spiked with the analyte at 5.0 and 1.5 ng mL−1 concentration levels. Following a very simple procedure, involving only sample dilution, mean recoveries (n = 7) of 98 ± 3% and 99 ± 3%, respectively, were obtained.  相似文献   

6.
A polyclonal antibody (Ab) for the progestin levonorgestrel (LNG) was generated, and immunochemical assays for its detection, clean-up and concentration were developed. A highly specific microplate diagnostic assay for the detection of LNG was developed that used the enzyme linked immunosorbent assay (ELISA) method. The LNG ELISA developed was sensitive and reproducible; it exhibited I50 and I20 values of 3.3 ± 1.8 ng mL−1 and 0.6 ± 0.4 ng mL−1, respectively, and the Abs did not cross react with any of the tested steroid hormones. The above Abs were used to develop a sol-gel-based immunoaffinity purification (IAP) method for concentration and clean-up of LNG that is compatible with subsequent immunochemical or instrumental chemical analytical procedures, such as liquid chromatography followed by mass spectrometry (LC-MS/MS). Development of the columns included successful entrapment of Abs within a tetramethoxysilane (TMOS)-based SiO2 polymer network. The Abs could bind the free analyte from solution, and the bound analyte could be easily eluted from the sol-gel matrix at high recoveries. The Ab selectivity towards the antigen was high, in both ELISA and the sol-gel columns, but the entrapped Abs cross-reacted with two other steroid hormones - ethynylestradiol (EE2) and nortestosterone (NT) - which share similar epitopes with LNG, despite the lack of cross reactivity in the ELISA. The validity of the method was investigated by LC-MS/MS and a good analytical correlation was obtained.  相似文献   

7.
It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B1 as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL−1 and threshold concentrations for TL-I–III were 0.125, 0.5, and 2.0 ng mL−1, respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0–0.06 ng mL−1 (negative samples), and 0.06–0.125 ng mL−1, 0.125–0.5 ng mL−1, 0.5–2.0 ng mL−1 and >2.0 ng mL−1 (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.  相似文献   

8.
The increasing global adoption of genetically modified (GM) plant derivatives in animal feed has provoked a strong demand for an appropriate detection method to evaluate the existence of transgenic protein in animal tissues and animal by-products derived from GM plant fed animals. A highly specific and sensitive sandwich enzyme immunoassay for the surveillance of transgenic Cry1Ab protein from Bt-maize in the blood plasma of cows fed on Bt-maize was developed and validated according to the criteria of EU-Decision 2002/657/EC. The sandwich assay is based on immuno-affinity purified polyclonal antibody raised against Cry1Ab protein in rabbits. Native and biotinylated forms of this antibody served as capture antibody and detection antibody for the ELISA, respectively. Streptavidin-horseradish peroxidase conjugate and TMB substrate provided the means for enzymatic colour development.The immunoassay allowed Cry1Ab protein determination in bovine blood plasma in an analytical range of 0.4-100 ng mL−1 with a decision limit (CCα) of 1.5 ng mL−1 and detection capability (CCβ) of 2.3 ng mL−1. Recoveries ranged from 89 to 106% (mean value of 98%) in spiked plasma.In total, 20 plasma samples from cows (n = 7) fed non-transgenic maize and 24 samples from cows (n = 8) fed transgenic maize (collected before and, after 1 and 2 months of feeding) were investigated for the presence of the Cry1Ab protein. There was no difference amongst both groups (all the samples were below 1.5 ng mL−1; CCα). No plasma sample was positive for the presence of the Cry1Ab protein at CCα and CCβ of the assay.  相似文献   

9.
N. Shokoufi 《Talanta》2007,73(4):662-667
A new combination method, employing thermal lens spectrometry (TLS) after cloud point extraction (CPE), has been developed for the preconcentration and determination of rhodium. TLS and CPE methods have good matching conditions for the combination because TLS is a suitable method for the analysis of low volume samples obtained after CPE.Rhodium was complexed with 1-(2-pyridylazo)-2-naphthol (PAN) as a complexing agent in an aqueous medium and concentrated by octylphenoxypolyethoxyethanol (Triton X-114) as a surfactant. After the phase separation at 50 °C based on the cloud point extraction of the mixture, the surfactant-rich phase was dried and the remaining phase was dissolved using 20 μL of carbon tetrachloride. The obtained solution was introduced into a quartz micro cell and the analyte was determined by laser induced-thermal lens spectrometry (LI-TLS). The single laser TLS was used as a sensitive method for the determination of Rhodium-PAN complex in 20 μL of the sample. Under optimum conditions, the analytical curve was linear for the concentration range of 0.5-50 ng mL−1 and the detection limit was 0.06 ng mL−1. The enhancement factor of 450 was achieved for 10 mL samples containing the analyte and relative standard deviations were lower than 5%. The developed method was successfully applied to the extraction and determination of rhodium in water samples.  相似文献   

10.
A promising pathway to improve on the sensitivity of protein microarrays is to immobilize the capture antibodies in a three dimensional hydrogel matrix. We describe a simple method based on printing of an aqueous protein solution containing a photosensitive polymer and the capture antibody onto a plastic chip surface. During short UV-exposure photocrosslinking occurs, which leads to formation of a hydrogel, which is simultaneously bound to the substrate surface. In the same reaction the antibody becomes covalently attached to the forming hydrogel. As the capture antibodies are immobilized in the three-dimensional hydrogel microstructures, high fluorescence intensities can be obtained. The chip system is designed such, that non-specific protein adsorption is strongly prevented. Thus, the background fluorescence is strongly reduced and very high signal-to-background ratios are obtained (SBR > 6 for cBSA = 1 pM; SBR > 100 for cBSA > 100 pM). The kinetics of antigen binding to the arrayed antibodies can be used to determine the concentration of a specific protein (for example the tumor marker β2-microglobulin) in solution for a broad range of analyte concentrations. By varying size and composition of the protein-filled hydrogel microstructures as well as adjusting the extent of labeling it is possible to easily adapt the surface concentration of the probe molecules such that the fluorescence signal intensity is tuned to the prevalence of the protein in the analyte. As a consequence, the signal tuning allows to analyze solutions, which contain both proteins with high (here: upper mg mL−1 range) and with very low concentrations (here: lower μg mL−1 range). This way quantitative analysis with an exceptionally large dynamic range can be performed.  相似文献   

11.
New highly sensitive enzyme immunoassay (EIA) has been developed and validated for the determination of pravastatin (PRV) in human plasma samples. PRV was coupled to keyhole limpt hemocyanin (KLH) and bovine serum albumin (BSA) via its terminal carboxylic acid group by carbodiimide reagent. PRV-KLH conjugate was used as an immunogen for raising anti-PRV polyclonal antibody in rabbits. The generated anti-PRV antibody recognized PRV with high affinity and selectivity. PRV-BSA conjugate was immobilized onto microwell plates and used as a solid phase. The assay involved a competitive binding reaction between PRV, in plasma sample, and the immobilized PRV-BSA for the binding sites on a limited amount of the anti-PRV antibody. The anti-PRV antibody bound to the plate wells was quantified with horseradish peroxidase-labeled anti-immunoglobulin second anti-rabbit IgG antibody and 3,3′,5,5′-tetramethylbenzidine as a substrate for the peroxidase enzyme. The concentration of PRV in the sample was quantified by its ability to inhibit the binding of the anti-PRV antibody to the immobilized PRV-BSA and subsequently the color development in the assay wells. The conditions of the proposed EIA were investigated and the optimum conditions were employed in the determination of PRV in plasma samples. The assay limit of detection was 0.2 ng mL−1 and the effective working range at relative standard deviation (RSD) of ≤5% was 0.5-20 ng mL−1. The mean analytical recovery of PRV from spiked plasma was 100.9 ± 2.98%. The precision of the assay was satisfactory; RSD was 2.61-3.70 and 3.96-4.17% for intra- and inter-assay precision, respectively. The analytical procedure is convenient, and one can analyze ∼200 samples per working day, facilitating the processing of large-number batch of samples. The proposed EIA has a great value in the routine analysis of PRV in plasma samples for its therapeutic monitoring and pharmacokinetic studies.  相似文献   

12.
A new approach, employing cloud point extraction (CPE) in combination with thermal lens spectrometry (TLS), has been developed for the determination of cobalt. The CPE and TLS methods have good matching conditions for combination because TLS is suitable for low volume samples obtained after CPE and for organic solvents, which are used for dissolving the remaining analyte phase.1-(2-Pyridylazo)-2-naphthol (PAN) was used as a complexing agent and octylphenoxypolyethoxyethanol (Triton X-114) was added as a surfactant; then the pH of solution was adjusted. After phase separation at 50 °C based on the cloud point extraction of the mixture, the surfactant-rich phase was dried and the remaining phase was dissolved using 20 μL of carbon tetrachloride. The obtained solution was introduced into the quartz micro cell and the analyte was determined by thermal lens spectrometry. The He-Ne laser (632.8 nm) was used as both the probe and the excite source.Under optimum conditions, the analytical curve was linear for the concentration range of 0.2-40 ng mL−1 and the detection limit was 0.03 ng mL−1. The enhancement factor of 470 was achieved for a 10 mL sample. Relative standard deviations were lower than 5%.The method was successfully applied to the extraction and determination of cobalt in tap, river and sea water.  相似文献   

13.
This study aimed at developing competitive enzyme-linked immunosorbent assays (ELISAs) for the organophosphorus (OP) insecticide fenitrothion using a monoclonal antibody. The hapten used to obtain the antibody had an ideal structural feature that allowed minimal functional group sacrifice. By using the antibody and a coating antigen, a competitive indirect ELISA was developed, which showed an IC50 of 14 ng mL−1 with a detection limit of 3.0 ng mL−1. A competitive direct ELISA using an enzyme tracer was also developed, which showed an IC50 of 17 ng mL−1 with a detection limit of 1.6 ng mL−1. The antibodies in both assays showed negligible cross-reactivity with the metabolites of fenitrothion and other OP pesticides except with the insecticides parathion-methyl and parathion-ethyl. Recoveries of fenitrothion from fortified rice and lettuce samples were determined and the bias in the recovery values was rationalized by using the standard curves obtained in the matrix extract.  相似文献   

14.
In the presented work, a disposable immunosensor for the detection of testosterone, an endogenous steroid hormone, in bovine urine has been developed using screen-printed electrodes (SPEs). Due to concerns over the use of steroid hormones as growth promoters, the EU prohibits their use in food producing animals. Consequently, rigorous screening procedures have been implemented in all member states to detect the illegal administration of such compounds. Competitive immunoassays were developed, initially by enzyme linked immunosorbent assay (ELISA), and subsequently transferred to an electrochemical immunosensor format using disposable screen-printed carbon electrodes. Horseradish peroxidase (HRP) was the enzyme label of choice and chronoamperometric detection was carried out using a tetramethylbenzidine/hydrogen peroxide (TMB/H2O2) substrate system, at +100 mV. The EC50 values obtained for the assay in buffer and urine gave relatively comparable results, 710 pg mL−1 and 960 pg mL−1, respectively. The linear range obtained for the assay in buffer extended from 0.03 ng mL−1 to 40 ng mL−1; while that in urine ranged from 0.03 ng mL−1 to 1.6 ng mL−1. The corresponding limits of detection (LOD) in buffer and urine were 26 pg mL−1 and 1.8 pg mL−1. Cross reactivity profiles of the antibody have been examined, with notable cross reactivities with 19-nortestosterone (11.6%) and boldenone (9.86%). Precision studies for the sensor demonstrated adequate reproducibility (CV < 13%, n = 3) and repeatability (CV < 9%, n = 3). Recovery data obtained showed good agreement between spiking studies and known concentrations of analyte. Sensors showed stability for 4 days at +4 °C. A sensitive, highly specific, inexpensive, disposable immunosensor, showing excellent overall performance for the detection of testosterone in bovine urine, has been developed.  相似文献   

15.
A homogeneous aggregation immunoassay involving the use of gold nanoparticles (AuNPs) and light scattering detection is described for soy protein determination in food samples. AuNPs act as enhancers of the precipitate that appears when the antigen-antibody complex is formed. The AuNPs-antibody conjugate has been synthesized by physical adsorption of polyclonal anti-soy protein antibodies onto the surface of commercial AuNPs with a nominal diameter of 20 nm. The direct assay is based on the reaction of the conjugate with soy protein, which reaches the equilibrium in about 10 min, and the measurement of the light scattering intensity at 530 nm, which is proportional to the analyte concentration. The dynamic range of the calibration graph is 0.2-20 μg mL−1 and the detection limit value is 65 ng mL−1. The precision, expressed as relative standard deviation, has been assayed at two different concentrations, 0.2 and 1 μg mL−1, giving values ranging from 4.7 to 5.9%. The interference of other proteins has been assayed. The usefulness of this method has been shown by its application to the analysis of fruit juice and “nonmilk yoghourt” samples. The results obtained with the proposed method are similar to those obtained by using a commercial ELISA kit, but the assay time is significantly shorter and the detection limit was about 10 times lower. A recovery study has been also performed, giving values in the range of 84.0-119.3%.  相似文献   

16.
A novel immunoassay format employing direct coating of small molecular hapten on microtiter plates is reported for the detection of atrazine and 2,4-dichlorophenoxyacetic (2,4-D). In this assay, the polystyrene surface of microtiter plates was first treated with an acid to generate -NO2 groups on the surface. Acid treated plates were further treated with 3-aminoprpyltriethoxysilane (APTES) to functionalize the plate surface with amino groups for covalent linkage to small molecular hapten with carboxyl groups. The modified plates showed significantly high antibody binding in comparison to plates coated with hapten-carrier protein conjugates and presented excellent stability as a function of the buffer pH and reaction time. The developed assay employing direct hapten coated plates and using affinity purified atrazine and 2,4-D antibodies demonstrated very high sensitivity, IC50 values for atrazine and 2,4-D equal to 0.8 ng mL−1 and 7 ng mL−1, respectively. The assay could detect atrazine and 2,4-D levels in standard water samples even at a very low concentration upto 0.02 and 0.7 ng mL−1 respectively in the optimum working range between 0.01 and 1000 ng mL−1 with good signal reproducibility (p values: 0.091 and 0.224 for atrazine and 2,4-D, respectively). The developed immunoassay format could be used as convenient quantitative tool for the sensitive screening of pesticides in samples.  相似文献   

17.
Two polychlorinated biphenyls (PCB) enzyme linked immunosorbent assays (ELISAs) were developed using goat PCB purified immunoglobulin (IgG) antibodies (Abs). The IgGs exhibited the highest affinity toward PCB-77 (24 ng mL−1) with sensitivities in the range of 6-11 ng mL−1. The Abs cross-reacted with PCB-126 and the heptachlorodibenzofuran 1,2,3,4,6,7,8-HpCDF but not with PCB-169, PCB-118, Aroclor 1232, 1248, 1260 or the hexachlorodibenzofuran 2,3,4,6,7,8-HxCDF. The IgGs were also used to develop a sol-gel-based immunoaffinity purification (IAP) method for cleanup of PCB-126. Recovery efficiencies depended on the sol-gel formats; a 1:12 format resulted in the highest binding capacity. Net binding capacity ranged from 112 to 257 ng, and 90% of the analyte could be eluted with only 2 mL of ethanol. The method was also very efficient in purifying PCB-126 from spiked soil and sediment samples from contaminated sites; and eliminating matrix interferences to a degree that enabled analysis of the purified samples by ELISA. The approaches developed in the course of the study form a basis for the development of additional IAP methods for other PCBs, and their implementation in high-throughput screening programs for PCB in food, soil, and other environmental and biological samples.  相似文献   

18.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

19.
Zhang Q  Wang L  Ahn KC  Sun Q  Hu B  Wang J  Liu F 《Analytica chimica acta》2007,596(2):303-311
Five haptens with different spacer-arm attachment sites on the structure of the organophosphorus insecticide fenthion were designed and synthesized. All of the haptens were conjugated with ovalbumin (OVA) for the coating antigen, and three haptens containing all or most of the structure of fenthion were conjugated with bovine serum albumin (BSA) for the immunogen. Six polyclonal antisera were raised against the three BSA conjugates, and 30 antibody/coating conjugate combinations were selected for studies of assay sensitivity and specificity for fenthion. The study revealed the best combination with high sensitivity (I50 of 0.08 ng mL−1) and high assay specificity, which indicated that when structural difference between the analyte and an immunizing hapten is less than that between a coating hapten and the immunizing hapten, a high sensitive enzyme-linked immunosorbent assay (ELISA) in the heterologous system may stand a good chance to be developed. The immunity results showed that heterology in the hapten spacer-arm attachment site of the immunogen could achieve a remarkable improvement in the quantity, sensitivity, and/or specificity of antibody, and that the moiety of an analyte, which is the same as the moiety near/on the immunizing spacer-arm hapten attachment site, contributes greatly to the interaction of antibody and hapten.  相似文献   

20.
A plastic ELISA-on-a-chip (EOC) employing the concept of cross-flow immuno-chromatographic analysis was applied to the measurement of botulinum neurotoxin A (BoNT/A) as agent for bio-terrorism. Two monoclonal antibodies specific to the heavy chain of the toxin were raised and identified to form sandwich binding complexes as the pair with the analyte. For the construction of an immuno-strip, one was utilized as the capture antibody immobilized onto nitrocellulose membrane and the other as the detection coupled to an enzyme, horseradish peroxidase. The two plates of EOC used in this study were fabricated by injection molding of polycarbonate to improve the reproducibility of manufacture and, after inclusion of the immuno-strip, bonded using a UV-sensitive adhesive. Under optimal conditions of analysis, the chip produced a color signal in proportion to the analyte dose and the signal was quantified using a detector equipped with a digital camera. From the dose-response curve, the detection limit of BoNT/A was 2.0 ng mL−1, approximately five times more sensitive than a commercial-version detection kit employing colloidal gold tracer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号