首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Nine volatile halogenated organic compounds (VHOCs), including four trihalomethanes (THMs), were determined in soils by capillary gas chromatography with microwave induced-plasma atomic emission spectrometry (GC-AED), using a purge-and-trap system (PT) for sample preconcentration. Analytes were previously extracted from the soil sample in methanol and the extract was preconcentrated before being chromatographed. Element-specific detection and quantification were carried out monitoring two wavelength emission lines, corresponding to chlorine (479 nm) and bromine (478 nm). Each chromatographic run took 21 min, including the purge step. The method showed a precision of 1.1-7.2% (R.S.D.) depending on the compound. Detection limits ranged from 0.05 to 0.55 ng ml−1, for chloroform and dichloromethane, respectively, corresponding to 3.3 and 36.0 ng g−1 in the soil samples. The chromatographic profiles obtained showed no interference from co-extracted compounds. Low levels of dichloromethane and chloroform ranging from 0.04 to 1.13 μg g−1 were found in samples obtained from small gardens irrigated with tap water. The method is reliable and can be used for routine monitoring in soil samples.  相似文献   

2.
Epichlorohydrin (ECH) can enter drinking-water supplies due to leaching from epoxy resins in contact with water and/or through the use of flocculating water treatment agents. Potential human exposure from drinking waters poses a particular concern on account of toxicological studies showing severe acute and long-term toxic effects of ECH. Recently a parametric value of 0.1 μg/L for ECH in drinking water has been established by European Union.A few methods for ECH determination in water are available. However, they usually adopt cumbersome procedures for sample preparation and provide sensitivity not matching the EU criteria for water monitoring purposes.In this study we investigated the analytical performance of gas extraction techniques, such as static headspace (HS) and purge and trap (P&T), coupled to gas chromatography (GC) with an electron capture detector (GC-ECD) for the determination of ECH in drinking water. The influence of different parameters affecting the analytical response was studied in details in order to enhance the method sensitivity, thus fulfilling the regulatory requirements.The P&T GC-ECD method was proved capable of determining ECH in water for human consumption at a detection limit of 0.01 μg/L fully complying the regulatory levels. On the contrary, the HS GC-ECD method is far less sensitive (LOD≅40 μg/L) than the previous cited method. The P&T GC-ECD method is simple, rapid, automated, safe for operators and does not require large sample volumes. Therefore, it is useful for routine laboratory activities both for control and research actions.  相似文献   

3.
吹扫捕集-气相色谱联用测定城市河流中的挥发性硫化物   总被引:7,自引:0,他引:7  
建立了一种吹扫捕集 气相色谱联用测定城市河流中挥发性硫化物的方法。二甲基硫、甲基乙基硫、二甲基二硫最低检测质量浓度分别为80,80和100ng/L,水样加标回收率在91%~101%之间。方法操作简单,灵敏度高,成功应用于城市河流中水样中挥发性硫化物的测定。  相似文献   

4.
This work presents the development of a novel procedure for the determination of trihalomethanes (THMs) in human urine samples based on: (1) pervaporation (PV) of analytes from urine samples as a convenient analyte isolation/enrichment technique; (2) direct aqueous injection of the extracts onto the column of a gas chromatograph equipped with an electron capture detector (DAI-GC-ECD). Basic parameters of the new PV-DAI-GC-ECD procedure were evaluated. The calibration curves were linear in the concentration range examined. Intermediate precision of the procedure was good, at the same level of about 20% for all analytes. The method detection limits were below 0.10?µg?L?1 for all analytes. The enrichment factors did not differ significantly for water and urine samples, indicating little or no matrix effects.  相似文献   

5.
Zhao RS  Lao WJ  Xu XB 《Talanta》2004,62(4):751-756
In the present work, a novel method for the determination of trihalomethanes (THMs) such as chloroform, dichlorobromomethane, chlorodibromomethane and bromoform in drinking water has been described. It is based on coupling headspace liquid-phase microextraction (HS-LPME) with gas chromatography-electron capture detector (GC-ECD). A microdrop of organic solvent at the tip of a commercial microsyringe was used to extract analytes from aqueous samples. Three organic solvents—xylene, ethylene glycol and 1-octanol—were compared and 1-octanol was the most sensitive solvent for the analytes. Extraction conditions such as headspace volume, extraction time, stirring rate, content of NaCl and extraction temperature were found to have significant influence on extraction efficiency. The optimized conditions were 15 ml headspace volume in a 40 ml vial, 10 min extraction time and 800 rpm stirring rate at 20 °C with 0.3 g ml−1 NaCl. The linear range was 1-100 μg l−1 for THMs. The limits of detection (LODs) ranged from 0.15 μg l−1 (for dichlorobromomethane and chlorodibromomethane) to 0.4 μg l−1 (for chloroform); and relative standard deviations (RSD) for most of THMs at the 10 μg l−1 level were below 10%. Real samples collected from tap water and well water were successfully analyzed using the proposed method. The recovery of spiked water samples was from 101 to 112%.  相似文献   

6.
A method using an automated on-line purge and trap gas chromatograph with a dry electrolytic conductivity detector (DELCD) has been developed for monitoring four regulated trihalomethanes in drinking water distribution systems. This analyzer samples trihalomethanes from drinking water by pervaporation through a silicone capillary membrane contained within a gas extraction cell (GEC) followed by preconcentration using an adsorbent trap. Trihalomethanes are subsequently desorbed from the trap onto a capillary column, separated and detected. The analyzer operates in real-time, samples directly from the drinking water distribution system and is fully automated. The optimization, operation, and evaluation of the analyzer and method are discussed. Method detection limits (MDL) are less than 1.0 μg L−1 with acceptable estimates for accuracy, and precision. The results from two on-line monitoring studies in chlorinated and chloraminated distribution systems are presented. The performance of the method is compared directly to United Stated Environmental Protection Agency Method 502.2 and shows a very slight, but acceptable bias.  相似文献   

7.
In power stations, the cooling effluents are chlorinated to avoid excessive biofouling. Yet, this disinfecting treatment leads to the formation of halogenated by-products, mainly trihalomethanes. So, there is a need for precise and accurate methods that allow trace levels determination of these compounds. A system that combines purge-and-trap and gas chromatography (with an electron capture detector) was used in this study. After careful choice of the experimental conditions, the performance of the system were evaluated. Precise and accurate determinations were obtained, allowing the determination of trihalomethanes in sea water samples chlorinated on site in three French coastal power stations. Bromoform was the predominant component formed, while traces of dibromochloromethane, chloroform and bromodichloromethane were also detected.  相似文献   

8.
A novel purge-and-trap method coupled with gas chromatography-mass spectrometry (GC-MS) is developed for the analysis of trace and ultratrace phenols based on their derivatization with acetic anhydride. Parameters affecting the extraction efficiency, such as purge temperature, concentration of sodium chloride, purge time, and volume of derivatization reagent, were investigated. The optimized conditions were addition of 150 μL acetic anhydride, purge time of 25 min at the purge temperature of 60 °C with 30% NaCl. The linear range was 0.2–100 μg L−1 for phenols. The limits of detection (LODs) ranged from 0.08 to 0.15 μg L−1 and the relative standard deviations (RSDs) for most of the phenols at the 10 μg L−1level were below 10%. Natural water samples collected from a pool were successfully analyzed using the proposed method. The recovery of spiked water samples was 72.9–84.2%.  相似文献   

9.
A procedure for the simultaneous determination of six organotin compounds, including methyl-, butyl- and phenyltins, in waters and marine sediments is developed. The analytes were leached from the solid samples into an acetic acid:methanol mixture by using an ultrasonic probe. The organotins were derivatized with sodium tetraethylborate (NaBEt4) in the aqueous phase, stripped by a flow of helium, pre-concentrated in a trap and thermally desorbed. This was followed by capillary gas chromatography with microwave-induced plasma atomic emission spectrometry as the detection system (GC-AED). Each chromatographic run took 22 min, including the purge time. Calibration curves were obtained by plotting peak area versus concentration and the correlation coefficients for linear calibration were at least 0.9991. Detection limits ranged from 11 to 50 ng Sn l−1 for tributyltin and tetramethyltin, respectively. The seawater samples analyzed contained variable concentrations of mono-, di- and tributyl- and monophenyltin, ranging from 0.05 to 0.48 μg Sn l−1, depending on the compound. Some of the sediments analyzed contained concentrations of dibutyl- and tributyltin of between 6.0 and 13.0 ng Sn g−1. Analysis of the certified reference material PACS-2, as well as of spiked water and sediment samples showed the accuracy of the method. The proposed method is selective and reproducible, and is considered suitable for monitoring organotin compounds in water and sediment samples.  相似文献   

10.
Summary A new gas chromatographic method using an automatic purge-and-trap system coupled to a GC with mass selective detection to analyze styrene at the parts-per-trillions (ng kg−1) level is described. The method shows a good sensitivity and the detection limit is 10 ng kg−1 with a relative standard deviation (RSD) of 4.7 % for 164 ng kg−1 styrene in olive oil. This analytical method has been successfully applied to the analysis of styrene in extra-virgin olive oil from the European market.  相似文献   

11.
Summary A new gas chromatographic method using an automatic purge-and-trap system coupled to a GC with mass selective detection to analyze styrene at the parts-per-trillions (ng kg–1) level is described. The method shows a good sensitivity and the detection limit is 10 ng kg–1 with a relative standard deviation (RSD) of 4.7% for 164 ng kg–1 styrene in olive oil. This analytical method has been successfully applied to the analysis of styrene in extra-virgin olive oil from the European market.  相似文献   

12.
A liquid-phase microextraction method for the determination of trihalomethanes (THMs) including chloroform (CHCl3), bromodichloromethane (CHBrCl2), dibromochloromethane (CHBr2Cl) and bromoform (CHBr3) in water samples was developed, with analysis by gas chromatography-electron capture detection (GC-ECD). After the determination of the most suitable solvent and stirring rate for the extraction, several other parameters (solvent drop volume, extraction time and ionic strength of the sample) were optimized using a factorial design to obtain the most relevant variables. The optimized extraction conditions for 5 mL of sample volume in a 10 mL vial were as follows: n-hexane an organic solvent; a solvent drop volume of 2 μL; an extraction time of 5.0 min; a stirring rate of 600 rpm at 25 °C; sample ionic strength of 3 M sodium chloride. The linear range was 1-75 μg L−1 for the studied THMs. The limits of detection (LODs) ranged from 0.23 μg L−1 (for CHBr2Cl) to 0.45 μg L−1 (for CHCl3). Recoveries of THMs from fortified distilled water were over 70% for a fortification level of 15 μg L−1, and relative standard deviations of the recoveries were below 5%. Real samples collected from tap water and well water were successfully analyzed using the proposed method. The recovery of spiked water samples was from 73% to 78% with relative standard deviations below 7%.  相似文献   

13.
14.
Li2O-ZrO2-BaO-SiO2 glass fibers were produced and their surfaces were coated with zinc oxide. The fibers’ surface morphology was examined by scanning electron microscopy and the zinc oxide layer was characterized by mapping the Kα and Lα lines of zinc by energy dispersive X-ray spectroscopy. The results indicated that a homogeneous and porous layer of ZnO was formed on the fibers’ surface. This layer was subjected to a simultaneous determination of trihalomethanes using headspace-solid phase microextraction-gas chromatography. The study was conducted after evaluating the ideal time of incubation (15 min), extraction (15 min) and desorption (10 min), as well as the effect of the addition of salt (15%, m/v) on the analytical response. A good linear dynamic range was observed individually for trihalomethanes aqueous solutions containing 20 μg L−1 and 500 μg L−1 of trichloromethane, 15 μg L−1 and 250 μg L−1 of dichlorobromomethane and dibromochloromethane and 10 μg L−1 and 100 μg L−1 of tribromomethane, with all the compounds showing correlation coefficients higher than 0.9900.  相似文献   

15.
An analytical method based on membrane introduction and fast gas chromatography-mass spectrometry (GC-MS) has been developed for the on-line monitoring of trihatomethanes (THMs) in chlorinated drinking water. The coupling of membrane introduction with fast GC-MS offers the advantage of membrane introduction as an on-line sampling device and fast GC-MS as a separation and identification method. While maintaining the on-line monitoring characteristic of traditional membrane introduction mass spectrometry (MIMS), the difficulty of distinguishing CHCl3 and CHBrCl2 in MIMS was overcome by rapid GC separation and MS analysis. Water permeated across the membrane affected the analysis of CHBr2Cl and CHBr3. A method based on controlling the injection temperature and injection time has been developed to overcome the moisture problem. This method is simple and less time consuming than the conventional moisture removing method. Under typical operating conditions, the sampling rate was about 20 samples h(-1) capable of on-line monitoring THMs in chlorinated drinking water. The detection limits of this system were found to be about 2 ppt, 4 ppt, 4 ppt, and 8 ppt for CHCl3 CHBrCl2, CHBr2Cl, and CHBr3, respectively.  相似文献   

16.
A method based on simplified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) extraction followed by large-injection volume-fast gas chromatography and mass spectrometry detection has been developed for the determination of trihalomethanes (chloroform, bromodichloromethane, dibromochloromethane and bromoform) and BTEX (benzene, toluene, ethylbenzene and xylenes) in soil samples.The simplified version of QuEChERS used meets the requirements of the “green chemistry” and provides reliable results with high sample throughput, low solvent consumption, little labour and the use of materials commonly employed in laboratories. The GC device used is equipped with a programmable temperature vaporizer (PTV), with a liner packed with Tenax-TA®. Using the solvent-vent mode, the PTV allows the injection of large volumes of sample, affording an improvement in the sensitivity of the method. The chromatographic conditions used here allowed the separation of the compounds in less than 5.50 min. Good linearity was obtained for all the target compounds, with highly satisfactory repeatability and reproducibility values. The limits of detection were in the 0.2 to 15 μg kg−1 range. The method was validated by the analysis of two certified reference materials.  相似文献   

17.
The analysis of volatile organic compounds in samples of biological fluids characterized by complex matrices is highly challenging. This paper presents a comparison of the results obtained in this field using three solvent-free techniques: thin-layer headspace with autogenous generation of liquid sorbent (TLHS) and membrane separation of the trace substances (pervaporation, PV), both of which are coupled to direct aqueous injection gas chromatography–electron capture detection (TLHS–DAI–GC–ECD and PV–DAI–GC–ECD), as well as conventional static headspace analysis followed by GC analysis with ECD detection (HS–GC–ECD). Basic validation parameters of the HS–GC–ECD, TLHS–DAI–GC–ECD and PV–DAI–GC–ECD procedures were calculated for water and urine samples. The calibration curves for all procedures were linear within the concentration range examined. The intermediate precisions of the procedures were good and reached about 10% (for all analytes) for HS–GC–ECD and TLHS–DAI–GC–ECD. The poorest results were obtained for PV–DAI–GC–ECD: about 20% for all analytes. The lowest method detection limits were obtained for the TLHS–DAI–GC–ECD procedure: below 0.0022 μg/L for all analytes. The enrichment factors did not differ significantly between water and urine samples, indicating little or no matrix effect in all procedures.  相似文献   

18.
A method based on QuEChERS extraction is proposed for the determination of trihalomethanes (chloroform, bromodichloromethane, dibromocloromethane and bromoform) in soil samples. The new version of QuEChERS adapted to soil samples consists of liquid extraction with ethyl acetate, the addition of water to moisten the samples, salting-out partitioning of the water with anhydrous MgSO4, and direct injection of the organic extract, obtained after the centrifugation step, into the gas chromatograph. This simplified extraction procedure maintains the advantages of the original method and avoids some steps, making the final procedure simpler, faster, and cheaper, with the consequent reduction in errors associated with sample manipulation. The experimental conditions of the analytical method, based on fast gas chromatography (FGC) and micro-electron capture detection (μECD), were optimized. The column and oven program used allowed fast separation of the compounds in less than 4 min and the total analysis cycle time was as short as 10 min. The existence of a matrix effect was checked and the analytical conditions of the method were studied in a fortified garden soil sample. The highly sensitive and selective detector used afforded to detection limits in the order of ng/kg for the target compounds. To validate the proposed method two certified reference materials (CRMs) were analyzed.  相似文献   

19.
20.
An analytical system composed of a purge-and-trap injection system coupled to gas chromatography with mass spectrometric detection (PTI-GC-MS) specific for the analysis of volatile chlorinated hydrocarbons (VCHCs) (chloroform; 1,1,1-trichloroethane; tetrachloromethane; 1,1,2-trichloroethylene; tetrachloroethylene) and trihalomethanes (THMs) (chloroform; bromodichloromethane; dibromochloromethane; bromoform) in water was optimised. Samples were purged and trapped in a cold trap (-100 degrees C) fed with liquid nitrogen (cryo-concentration). In order to make this method suitable also for only slightly contaminated waters, some modifications were made to PTI sample introduction, in order to avoid any air intake into the system. PTI, GC and MS conditions were optimised for halogenated compound analysis and limits of detection (LOD) were evaluated. The proposed method allows analysis of samples whose concentrations range from microg/L to ng/L. It is, therefore, applicable to drinking waters, in analyses required by law, and to slightly contaminated aqueous matrices, such as those found in remote areas, in environmental monitoring. Moreover, by changing cold trap temperature, even sparkling mineral waters can be analysed, thus avoiding CO2 interference during the cryo-concentration phase. Our method has been successfully used on real samples: tap water, mineral water and Antarctic snow.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号