首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid technique based on dynamic microwave-assisted extraction (DMAE) coupled on-line with solid-phase extraction (SPE) was developed for the determination of sulfonamides (SAs) including sulfadiazine, sulfameter, sulfamonomethoxine and sulfaquinoxaline in soil. The SAs were first extracted with acetonitrile under the action of microwave energy, and then directly introduced into the SPE column which was packed with neutral alumina for preconcentration of analytes and clean-up of sample matrix. Subsequently, the SAs trapped on the alumina were eluted with 0.3% acetic acid aqueous solution and determined by liquid chromatography-tandem mass spectrometry. The DMAE parameters were optimized by the Box-Behnken design. Maximum extraction efficiency was achieved using 320 W of microwave power; 12 mL of extraction solvent and 0.8 mL min−1 of extraction solvent flow rate. The limits of detection and quantification obtained are in the range of 1.4-4.8 ng g−1 and 4.6-16.0 ng g−1 for the SAs, respectively. The mean values of relative standard deviation of intra- and inter-day ranging from 2.7% to 5.3% and from 5.6% to 6.7% are obtained, respectively. The recoveries of SAs obtained by analyzing four spiked soil samples at three fortified levels (20 ng g−1, 100 ng g−1 and 500 ng g−1) were from 82.6 ± 6.0% to 93.7 ± 5.5%. The effect of standing time of spiked soil sample on the SAs recoveries was examined. The recoveries of SAs decreased from (86.3-101.9)% to (37.6-47.5)% when the standing time changed from one day to four weeks.  相似文献   

2.
A simple method based on magnetic separation for selective extraction of fluoroquinolones (FQs) from environmental water samples has been developed using magnetic molecularly imprinted polymer (MMIP) as sorbent. The MMIP has been prepared using ciprofloxacin as template molecule, methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linking agent and Fe3O4 magnetite as magnetic component. The polymer has been characterized by scanning electron microscopy, Fourier-transform infrared spectrometry and vibrating sample magnetometry. Various parameters affecting the extraction efficiency were evaluated in order to achieve optimal concentration and reduce non-specific interactions. The analytes desorbed from the polymers were determined by liquid chromatography-tandem mass spectrometry. The matrix effect was evaluated by using different washing solvents for removing interfering compounds from the MMIPs after sample loading. Under the optimal conditions, the linearity of the method obtained is in the range of 20-2000 ng L−1. The detection limits of FQs are in the range of 3.2-6.2 ng L−1. The relative standard deviations of intra- and inter-day tests ranging from 2.5 to 7.2% and from 3.6 to 9.1% are obtained. In all three spiked levels (20, 100 and 200 ng L−1), the recoveries of FQs are in the range of 76.3-94.2%. The proposed method was successfully applied to determine FQs including ciprofloxacin, enrofloxacin, lomefloxacin, levofloxacin, fleroxacin and sparfloxacin in different water samples, such as lake water, river water, primary and final sewage effluent. Ciprofloxacin and fleroxacin were found in primary and final sewage effluent samples with the contents in the range of 26-87 ng L−1.  相似文献   

3.
杜鹃  赵洪霞  陈景文 《色谱》2015,33(4):348-353
建立了固相萃取-高效液相色谱-串联质谱(SPE-HPLC-MS/MS)同时检测水中6类23种抗生素的分析方法。水样用固相萃取柱富集净化,通过对比水样在不同上样pH、洗脱液用量等条件下的回收率,优化了前处理方法。采用0.1%(v/v)甲酸-1 g/L甲酸铵水溶液和甲醇-乙腈(1:1, v/v)体系作为流动相,经过梯度洗脱进行分离,在HPLC-MS/MS多反应监测模式下进行定性定量分析。结果显示,23种抗生素的方法检出限(MDL)范围为0.1~2.9 ng/L,加标回收率为47.3%~132.6%。采用该方法对东营海水养殖区5个养殖池水样进行了检测,除青霉素类之外的各类抗生素均有检出,其中磺胺增效剂甲氧苄氨嘧啶的检出率达100%,氯霉素类抗生素氟甲砜霉素检出的最高质量浓度达到261.0 ng/L。结果表明,所建立的方法高效、灵敏、可靠,可用于海水中多种抗生素的分析。  相似文献   

4.
The detection of ethyl-β-d-6-glucuronide (EtG), a stable phase II metabolite of ethanol, is of interest in both clinical and forensic contexts with the aim of monitoring alcohol abuse. We present a liquid chromatography-electrospray ionisation-tandem mass spectrometry method for the detection and quantification of EtG in hair. Thirty milligrams of washed and cut hair were cleaned up using solid-phase extraction graphite cartridges. Separation was then performed using an Uptisphere-3SI column, and the detection was operated in the negative mode. After validation, the method was applied to hair samples taken from four fatalities (F) with documented excessive drinking habits, 12 heavy drinkers (HD) and seven social drinkers (SD). The method exhibits limits of detection and quantification of 4 and 10 pg/mg, respectively. Intra- and inter-assay standard deviation and relative bias were less than 20% over the calibrating range (10 to 3,000 pg/mg). EtG hair concentrations in SD were <10 pg/mg and >50 pg/mg for F and HD (range, 54 to 497 pg/mg). The present assay appears convenient to carry out owing to the very small quantity of hair samples required to determine an effective heavy alcohol consumption (EtG hair concentration >50 pg/mg).  相似文献   

5.
A procedure for the determination of six derivatives of 2-hydroxybenzophenone, used as UV absorbers, in water samples is presented. Compounds were first concentrated using a solid-phase extraction (SPE) cartridge and then selectively determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using electrospray ionization (ESI). The effect of different parameters on the performance of concentration and determination steps is discussed. The highly polar and acidic 2-hydroxy-4-methoxybenzophenone-5-sulfonic acid (BP-4) required the use of ammonium acetate as modifier during desorption of SPE cartridges and also to improve the performance of its separation in the LC column. Under optimized conditions, the proposed method provided limits of quantification from less than 1 to 32 ng L−1, depending on the compound and the type of water sample. Recoveries from the SPE step (83-105%) remained unaffected by the nature of the matrix; however, the efficiency of electrospray ionization was compound and sample dependant. Real sample analysis reflected the presence of three of the six investigated species (BP-4, 2-hydroxy-4-methoxybenzophenone, BP-3, and 2,4-dihydroxybenzophenone, BP-1) in the aquatic environment, particularly in raw wastewater samples. In this latter matrix, BP-4 was the compound presenting the highest concentrations; moreover, it was poorly removed in sewage treatment plants and consequently it also appeared in river water.  相似文献   

6.
王锦  叶开晓  田艳  刘珂  梁柳玲  李青倩  黄宁  王欣婷 《色谱》2023,41(3):241-249
抗生素作为环境介质中一种典型的新污染物,在各类环境水样中检出频率高且浓度低。为快速、灵敏、准确地分析各类水体中的抗生素,建立了固相萃取-高效液相色谱-串联质谱法(SPE-HPLC-MS/MS)同时测定环境水样中4种青霉素类、12种喹诺酮类和6种大环内酯类共22种抗生素的分析方法。针对抗生素特性和样品基质特点优化前处理方法,重点优化固相萃取柱、水样pH值、水样中乙二胺四乙酸二钠(Na2EDTA)加入量。在200 mL水样中加入0.5 g Na2EDTA,并调节水样的pH值至3,经HLB固相萃取柱富集净化,以乙腈-0.15%(v/v)甲酸水溶液为流动相进行梯度洗脱,采用电喷雾电离源,在正离子模式下使用多反应监测模式进行定性定量分析。结果显示,22种抗生素的相关系数(r)≥0.995,呈现良好的线性关系,方法检出限和定量限分别为2.3~10.7 ng/L和9.2~42.8 ng/L,地表水中3个水平下的加标回收率为61.2%~157%,相对标准偏差(RSD)为1.0%~21.9%,废水中3个水平下的加标回收率为50.1%~129%, RSD为1.2%~16.9%。该方法成功用于水库、地表水、污水处理厂出口、畜禽养殖场等不同类型水样中抗生素的同时测定,其中地表水和畜禽养殖废水中大部分抗生素有检出,在地表水中林可霉素检出率为90%,在畜禽养殖废水中氧氟沙星的检出含量最高,为127 ng/L。该方法检出限和回收率满足定量分析要求,且具有富集水样体积少、分析时间短、适用范围广等优势,特别适用于突发环境污染应急监测,同时为摸清新污染物环境赋存底数和新污染物治理与管控提供有力支撑。  相似文献   

7.
利用超高效液相色谱-电喷雾串联质谱(UPLC-MS/MS)方法测定了调味品中罗丹明B。样品经乙腈-乙酸水溶液提取后,经固相萃取(SPE)柱净化,采用BEH C18柱分离,以乙腈和0.2%的甲酸水溶液为流动相进行梯度洗脱,采用正离子、多反应监测(MRM)模式进行定性定量测定。罗丹明B在0.5~500μg/L质量浓度范围内线性关系良好,相关系数r为0.999,检出限、定量限分别为0.03,0.10μg/kg;平均回收率为86.6%~95.7%,标准偏差小于10%。方法适用于调味品中罗丹明B的测定。  相似文献   

8.
张晓光  刘东  刘红冉  李强  李立理  王丽霞  张岩 《色谱》2017,35(10):1055-1061
建立了在线固相萃取净化-液相色谱-串联质谱检测猪肉中10种大环内酯类抗生素残留的方法。样品经过乙腈提取,提取液40℃旋蒸至干后,分析物用2 mL磷酸盐缓冲液溶解,溶解液经在线固相萃取柱(HLB柱)富集净化,甲醇洗脱,然后转移至XBridge BEH C18色谱柱上,以10 mmol/L乙酸铵水溶液和乙腈溶液为流动相进行分离,最后用串联四极杆质谱检测。结果表明,10种大环内酯类抗生素在0.1~200μg/L范围内呈现良好的线性关系,相关系数均大于0.990。方法的检出限范围为0.05~0.30μg/kg,定量限范围为0.10~1.00μg/kg;添加水平为0.10~10.0μg/kg时,方法回收率为69.6%~115.2%,相对标准偏差(RSD)10%。该方法可以作为猪肉中大环内酯类抗生素的检测方法。  相似文献   

9.
We developed a sensitive and useful method for the determination of five fluoroquinolones (FQs), enoxacin, ofloxacin, ciprofloxacin, norfloxacin, and lomefloxacin in environmental waters, using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These compounds were analysed within 7 min by high-performance liquid chromatography (HPLC) using a CAPCELL PAK C8 column and aqueous ammonium formate (pH 3.0, 5 mM)/acetonitrile (85/15, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection. In order to optimize the extraction of FQs, several in-tube SPME parameters were examined. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow-rate of 150 μL/min, using a Carboxen 1010 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r ≥ 0.997) was obtained in the concentration range from 0.1 to 10 ng/mL for all compounds examined. The limits of detection (S/N = 3) of the five FQs ranged from 7 to 29 pg/mL. The in-tube SPME method showed 60-94-fold higher sensitivity than the direct injection method (5 μL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface waters and wastewaters were collected from the area around Asahi River, and ofloxacin was detected in wastewater samples of a sewage treatment plant and other two hospitals at 17.5-186.2 pg/mL. The recoveries of FQs spiked into river water were above 81% for a 0.1 or 0.2 ng/mL spiking concentration, and the relative standard deviations were below 1.9-8.6%.  相似文献   

10.
建立了固相萃取-高效液相色谱-串联质谱(SPE-HPLC-MS/MS)同时检测表层水中5类40种抗生素的分析方法。水样经过滤、固相萃取柱富集净化后,以乙腈-0.2%(v/v)甲酸水溶液为流动相进行梯度洗脱,采用电喷雾电离源,在多反应监测、正离子模式进行定性定量分析。结果显示,40种抗生素在1~200 μg/L水平下线性关系良好,平均加标回收率为41.3%~112.6%。采用该方法对长江南京段表层水体进行检测,共检出13种抗生素,含量为13.4~780.5 ng/L,其中喹诺酮类抗生素恩诺沙星检出率达100%,大环内酯类抗生素克林霉素最高检出水平达739.4 ng/L。该法高效、灵敏、可靠,可用于实际水样中多种抗生素的分析。  相似文献   

11.
Capillary liquid chromatography (cLC) hyphenated with tandem mass spectrometry (MS-MS) was used to separate and quantitate trace concentrations of five estrogens in aqueous samples. New C(18)-based sorption materials bound to the silica support by monomeric and polymeric mechanisms were compared and tested for solid-phase extraction (SPE) of selected analytes with respect to optimization of their preconcentration yield. Application of an endcapped, monomer-bound preconcentration Discovery DSC-18Lt column under the optimized conditions provides yields in the range from 95 to 100% with a high repeatability (n=3, RSD≤7.2%). Using the electrospray ionization in the positive mode (ESI+), the cLC-MS-MS system (the Zorbax SB C18 capillary column and a binary mobile phase of acetonitrile and water containing 0.1% formic acid in both the components) was optimized to attain a sufficient retention of the early eluting estriol, a satisfactory resolution of the analytes and the maximum sensitivity of the determination. Both the isocratic and gradient elution were used and the optimized gradient method permitted analyses of aqueous environmental samples in 14 min within a linearity range from 6.1 to 25.0 (LOQ of analytes) to 500 ng/L and with a very good linearity (r>0.9981) for all the estrogens studied. The detection limits are in the range from 3.0 to 6.8 ng/L (1 μL injection volume). Six environmental water samples were analyzed and the studied estrogens were found in the Vltava river sample collected in Prague (13.2 ng/L for 17β-estradiol) and in the inlet to the wastewater treatment plant in Prague, at an overall concentration of 371.4 ng/L.  相似文献   

12.
Xie W  Han C  Qian Y  Ding H  Chen X  Xi J 《Journal of chromatography. A》2011,1218(28):4426-4433
This work reports a new sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection, confirmation and quantification of six neonicotinoid pesticides (dinotefuran, thiamethoxam, clothiandin, imidacloprid, acetamiprid and thiacloprid) in agricultural samples (chestnut, shallot, ginger and tea). Activated carbon and HLB solid-phase extraction cartridges were used for cleaning up the extracts. Analysis is performed by LC-MS/MS operated in the multiple reaction monitoring (MRM) mode, acquiring two specific precursor-product ion transitions per target compound. Quantification was carried by the internal standard method with D(4)-labeled imidacloprid. The method showed excellent linearity (R(2)≥0.9991) and precision (relative standard deviation, RSD≤8.6%) for all compounds. Limits of quantification (LOQs) were 0.01 mg kg(-1) for chestnut, shallot, ginger sample and 0.02 mg kg(-1) for tea sample. The average recoveries, measured at three concentrations levels (0.01 mg kg(-1), 0.02 mg kg(-1) and 0.1 mg kg(-1) for chestnut, shallot, ginger sample, 0.02 mg kg(-1), 0.04 mg kg(-1) and 0.2 mg kg(-1) for tea sample), were in the range 82.1-108.5%. The method was satisfactorily validated for the analysis of 150 agricultural samples (chestnut, shallot, ginger and tea). Imidacloprid and acetamiprid were detected at concentration levels ranging from 0.05 to 3.6 mg kg(-1).  相似文献   

13.
胡钰  朱青青  胡立刚  廖春阳 《色谱》2021,39(8):878-888
土壤基质复杂,土壤中残留的抗生素种类繁多,浓度多为痕量水平,高灵敏度的仪器方法、有效的净化和富集方法、多种类抗生素的同时检测是土壤中抗生素检测的重点和难点.该研究建立了固相萃取-超高效液相色谱-串联质谱法同时测定土壤中7类(磺胺类、氟喹诺酮类、四环素类、大环内酯类、β-内酰胺类、酰胺醇类和林可酰胺类)30种抗生素的方法...  相似文献   

14.
An improved analytical method for determination of human pharmaceuticals in natural and wastewaters with ng L−1 sensitivity is presented. The method is applicable to pharmaceuticals from a wide range of therapeutic classes including antibiotics, analgesics, anti-inflammatories and anti-cancer compounds. Pharmaceuticals were extracted from waters using solid-phase extraction, and after concentration, analysed by high performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). Identification of each compound was secured using retention time and by the selected reaction monitoring of two transitions, one of which was additionally used for quantification. Limits of detection ranged from 0.03 to 0.96 ng L−1 and were up to two orders of magnitude lower than those of previously published methods. The method was validated using spiked samples prepared from tap, river and sea water as well as wastewater effluents, collected from the North of Scotland. Analysis of wastewater effluents revealed the presence of mefenamic acid, ibuprofen, erythromycin, diclofenac and trimethoprim. None of the selected pharmaceuticals were detected in river, tap or sea water samples.  相似文献   

15.
This paper describes the development and validation of a method for the simultaneous determination of 53 multi-class emerging organic pollutants in water samples using solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), using electrospray ionisation (ESI) in both positive and negative modes. Target compounds include acidic herbicides, UV filters, insect repellents, organophosphorous flame retardants, a bactericide, pharmaceuticals and metabolites. A single SPE consisting on the loading of 200-500 mL of sample adjusted to pH 7 on Oasis HLB 200mg cartridges and elution with methanol, permitted obtaining good recoveries: higher than 60% for tap, surface and wastewater in most cases. The 7 isotopically labelled internal standards effectively compensated losses during sample preparation and matrix effects at LC-MS/MS determination. The precision of the method, calculated as relative standard deviation (RSD) was below 15% for all compounds and all tested matrices. Detection limits (LODs) based on the confirmation, less intense, MRM (multiple reaction monitoring) transition and considering blanks varied between 0.3 and 30 ngL(-1). Finally, the developed method was applied to the determination of target analytes in various samples, including tap, surface and waste water. Among the tested emerging pollutants, 31 were found in wastewater in concentrations reaching up to 10 microgL(-1) in the case of ibuprofen. Also, 13 species were detected in tap water with concentrations up to 0.13 microgL(-1) for tri(chloropropyl) phosphate (TCPP).  相似文献   

16.
朱峰  姚志建  霍宗利  吉文亮  刘华良  周庆  李爱民  焦伟  谷静 《色谱》2020,38(12):1465-1471
近年来,环境水体中出现的药物及个人护理品污染物受到人们越来越多的关注,其中就包括解热镇痛类药物。传统的固相萃取材料对水体中解热镇痛类药物的富集效率较低。为此,开发了一种亲水亲脂型的双亲多孔吸附聚合物材料(Guochuang hydrophilic material, GCHM)。以N-乙烯基吡咯烷酮和二乙烯基苯为原料,利用乳液胶束-分步反应法成功制备出GCHM。基于自主研发的固相萃取柱,采用超高效液相色谱-串联质谱技术,建立了水体中4种解热镇痛类药物的检测方法。水样经GCHM固相萃取柱富集净化后上机检测,以0.1%(v/v)甲酸水溶液和乙腈作为流动相进行梯度洗脱,目标分析物在ACQUITY UPLC■ HSS T3色谱柱(100 mm×2.1 mm, 1.8μm)上实现分离,在电喷雾正离子模式下进行多反应监测(MRM),内标法定量。比较Oasis HLB、Bond Elut Plexa和GCHM 3种固相萃取柱的富集效率,结果表明GCHM固相萃取柱总体效果最优。在不同pH值下比较了GCHM固相萃取柱对目标分析物的富集效果,并对基质效应进行了评估。结果表明,当pH为7时,4种目标分析物在...  相似文献   

17.
国明  于峰  贾科玲  李姣  孙海 《色谱》2016,34(4):407-413
建立了磁性固相萃取-高效液相色谱-串联质谱同时测定环境水样中四环素类抗生素的方法。以6种四环素类抗生素(差向四环素、土霉素、四环素、去甲金霉素、金霉素和脱水四环素)为目标化合物,考察并优化了吸附和解吸条件,确定了最佳萃取条件。萃取后的目标化合物经ZORBAX Eclipse Plus C18柱分离,用高效液相色谱-串联质谱在多反应监测(MRM)模式下进行检测。在优化的条件下,6种四环素在1~100 μg/L范围内线性关系良好,线性相关系数为0.9967~0.9993,检出限为2.44~25.21 ng/L,样品加标回收率为80.6%~90.0%,日内相对标准偏差(RSDs)为0.6%~2.5%,日间RSDs为1.1%~7.1%。该方法灵敏度高、背景干扰低,适用于环境水样中6种痕量四环素类抗生素的同时检测。  相似文献   

18.
建立了液相色谱-串联质谱技术同时检测水产品中15种喹诺酮类药物(氟罗沙星、氧氟沙星、依诺沙星、诺氟沙星、环丙沙星、恩诺沙星、洛关沙星、单诺沙星、奥比沙星、双氟沙星、沙拉沙星、司帕沙星、口恶喹酸、萘啶酸、氟甲喹)残留量的方法.试样中残留的喹诺酮类药物采用乙腈提取,提取液经正已烷液液分配脱脂后,以强阳离子固相萃取小柱净化,液相色谱.串联质谱法测定.对液/质分离条件与样品前处理条件进行了优化,并对喹诺酮类药物在分析过程的稳定性进行了研究.15种喹诺酮类药物在1.0~100 μg/L范围内线性关系良好,相关系数为0.9924~0.9992.在0.002~0.04 mg/kg浓度范围内,平均加标回收率在79.9%~93.8%;相对标准偏差为4.8%~14.6%.方法可满足水产品中喹诺酮类药物多残留检测与确证的需要.  相似文献   

19.
严丽娟  张峰  方恩华  郭彦妮  周昱  林立毅  储晓刚 《色谱》2010,28(11):1038-1042
建立了动物饲料中竹桃霉素、红霉素、吉他霉素、交沙霉素、罗红霉素、泰乐菌素6种大环内酯和林可霉素、克林霉素2种林可胺抗生素的超高效液相色谱-电喷雾串联质谱(UPLC-ESI-MS/MS)检测方法。饲料样品采用甲醇提取,Oasis HLB固相萃取柱富集净化,Waters Acquity UPLC BEH C18色谱柱分离,以0.1%甲酸和乙腈为流动相进行梯度洗脱,流速为0.3 mL/min,正离子模式扫描,多反应监测模式检测,外标法定量。实验结果表明,8种药物在1~100 μg/L范围内具有良好的线性关系。在空白饲料样品中分别添加1、10和100 μg/kg 3个加标水平的8种药物,其平均回收率为68.6%~95.2%,相对标准偏差(RSD)为4.9%~11.8%,定量限均为1 μg/kg。结果表明,该方法简便快速、灵敏度高,适用于动物饲料中大环内酯类和林可胺类抗生素的同时检测。  相似文献   

20.
A sensitive, economical, and miniaturized self-assembly pipette tip graphene solid-phase extraction (PT-G-SPE) coupled with liquid chromatography fluorescence detection (LC-FD) was developed for rapid extraction and determination of three sulfonamide antibiotics (SAs) in environmental water samples. The PT-G-SPE cartridge, assembled by packing 1.0 mg of graphene as sorbent into a 100 μL pipette tip, showed high adsorption capacity for the SAs owing to the large surface area and unique structure of graphene. The factors that affected the extraction efficiency of PT-G-SPE, including sample volume, pH, sorbent amount, washing solvent and eluent solvent were optimized. Good linearity for SAs was obtained in a range of 2–4000 pg mL−1 with correlation coefficients (r2) ≥ 0.9993. The recoveries of the SAs at three spiked levels ranged from 90.4% to 108.2% with relative standard deviations (RSD) ≤ 6.3%. In comparison with other sorbents such as C18, HLB, SCX, PCX, and multiwalled carbon nanotubes, one advantage of using graphene as sorbent of pipette tip solid-phase extraction (PT-SPE) was that PT-G-SPE could adsorb larger sample volume (10 mL) at a small amount of sorbent (1 mg) and low solvent consumption with good extraction efficiency, which not only increased the fraction of analytes to LC and the sensitivity of SAs determination, but also reduced the cost and pollution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号