首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
Summary A method for determining aromatic sulfonates in sea water is presented. Ion-pair solid phase extraction is coupled on-line to ion-pair liquid chromatography with UV detection. In the enrichment step, the recoveries from 100 mL of sea water were higher than 65% for most analytes. Linearity was good and detection limits were between 0.02 and 1 μgL−1. The repeatability of the method, expressed as % of relative standard deviation (n=3) was between 1 and 15%. The method was checked in coastal water near the commercial port of Tarragona, where effluents from the petrochemical industry are discharged. All the samples taken were found to contain 2-naphthalenesulfonate.  相似文献   

2.
刘志超  胡霞林  刘景富 《色谱》2010,28(5):513-516
以涂有聚二甲基硅氧烷(PDMS)的石英光导纤维作为固相微萃取纤维,建立了一次性固相微萃取与高效液相色谱联用测定环境水样中的菲、荧蒽和屈3种多环芳烃(PAHs)的方法。实验考察了解吸时间、萃取时间、搅拌速度、盐效应以及样品溶液pH值对萃取效率的影响,优化得到的萃取和解吸条件为: 于60 mL样品溶液中放入两段萃取纤维(1.5 cm)和1.2 g氯化钠,在1200 r/min搅拌速度下萃取60 min,取出萃取纤维并转入120 μL甲醇中密封静置解吸24 h后,取20 μL解吸液进行液相色谱测定。该方法对于菲、荧蒽和屈的检出限分别为0.17、0.17和0.08 μg/L;精密度(以测定0.5 μg/L PAHs标准溶液6次的相对标准偏差计)小于8%;实际样品中3种PAHs的加标回收率为80.0%~107%。该方法快速简便,纤维一次性使用,克服了污染物在纤维上残留的问题。  相似文献   

3.
A new, rapid and sensitive method for the determination of aromatic amines such as o-nitroaniline (NIT), alpha-naphtylamine (NAP), o-chloroaniline (CHL) in environmental water samples was developed with dispersive liquid phase micro-extraction coupled with high performance liquid chromatography. Preliminary experiments indicated that excellent achievements were obtained when chlorobenzene and acetonitrile were employed as the extraction solvent and dispersive solvent, respectively. Some other parameters that would have important effect on the pre-concentration of aromatic amines were investigated in detail. Under the optimal conditions, the method had excellent linear relationship between the peak area and the concentration for NIT, NAP and CHL in the concentration range of 1?~?50?µg?L?1. The limits of detection and precisions of the proposed method were in the range of 0.1?~?0.7?µg?L?1 and 6.3?~?9.7%, respectively. The proposed method has been validated with two real water samples, and the results showed that excellent spiked recoveries in the range of 92.8%?~?111.5% were achieved. All these demonstrated that the proposed method would be very useful and applicable for the determination of such pollutants in the future.  相似文献   

4.
Lubov Oliferova  Yury Zolotov 《Talanta》2007,72(4):1386-1391
Naphthalene, biphenyl, acenaphtene, anthracene and pyrene were extracted from water samples using inner walls of polytetrafluoroethylene capillary. Optimum conditions for sorption, desorption and heart-cutting of the analyte zone were found. Combined on-line solid-phase extraction and HPLC method for determination of these compounds was proposed. Limits of detection were: (μg L−1): 0.4 (naphthalene), 0.3 (biphenyl), 0.6 (acenaphtene), 0.2 (anthracene) and 0.1 (pyrene).  相似文献   

5.
A new and fast hollow fiber based liquid phase microextraction (HF-LPME) method using volatile organic solvents coupled with high-performance liquid chromatography (HPLC) was developed for determination of aromatic amines in the environmental water samples. Analytes including 3-nitroaniline, 3-chloroaniline and 4-bromoaniline were extracted from 6 mL basic aqueous sample solution (donor phase, NaOH 1 mol L−1) into the thin film of organic solvent that surrounded and impregnated the pores of the polypropylene hollow fiber wall (toluene, 20 μL), then back-extracted into the 6 μL acidified aqueous solution (acceptor phase, HCl 0.5 mol L−1) in the lumen of the two-end sealed hollow fiber. After the extraction, 5 μL of the acceptor phase was withdrawn into the syringe and injected directly into the HPLC system for the analysis. The parameters influencing the extraction efficiency including the kind of organic solvent and its volume, composition of donor and acceptor phases and the volume ratio between them, extraction time, stirring rate, salt addition and the effect of the analyte complexation with 18-crown-6 ether were investigated and optimized. Under the optimal conditions (donor phase: 6 mL of 1 mol L−1 NaOH with 10% NaCl; organic phase: 20 μL of toluene; acceptor phase: 6 μL of 0.5 mol L−1 HCl and 600 m mol L−1 18-crown-6 ether; pre-extraction and back-extraction times: 75 s and 10 min, respectively; stirring rate: 800 rpm), the obtained EFs were between 259 and 674, dynamic linear ranges were 0.1-1000 μg L−1 (R > 0.9991), and also the limits of detection were in the range of 0.01-0.1 μg L−1. The proposed procedure worked very well for real environmental water samples with microgram per liter level of the analytes, and good relative recoveries (91-102%) were obtained for the spiked sample solutions.  相似文献   

6.
In this work, a new microextraction method termed ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) was demonstrated for the extraction of 2-methylaniline, 4-chloroaniline, 1-naphthylamine and 4-aminobiphenyl in aqueous matrices. After extraction the ionic liquid (IL) phase was injected directly into the high performance liquid chromatography (HPLC) system for determination. Some parameters that might affect the extraction efficiency were optimized. Under the optimum conditions, good linear relationship, sensitivity and reproducibility were obtained. The limits of detection (LOD, S/N = 3) for the four analytes were in the range of 0.45-2.6 μg L^-1. The relative standard deviations (R.S.D., n = 6) were in the range of 6.2-9.8%. This method was applied for the analysis of the real water samples. The recoveries ranged from 93.4 to 106.4%. The main advantages of the method are high speed, high recovery, good repeatability and volatile organic solvent-free.  相似文献   

7.
This paper describes a simultaneously performed two-/three-phase hollow-fiber-based liquid-phase microextraction (HF-LPME) method for the determination of aromatic amines with a wide range of pKa (−4.25 to 4.6) and log KOW (0.9–2.8) values in environmental water samples. Analytes including aniline, 4-nitroaniline, 2,4-dinitroaniline and dicloran were extracted from basic aqueous samples (donor phase, DP) into the microliter volume of organic membrane phase impregnated into the pores of the polypropylene hollow fiber wall, then back extracted into the acidified aqueous solution (acceptor phase, AP) filling in the lumen of the hollow fiber. The mass transfer of the analytes from the donor phase through the organic membrane phase into acceptor phase was driven by both the counter-coupled transport of hydrogen ions and the pH gradient. Afterwards, the hollow fiber was eluted with 50 μL methanol to capture the analytes from both the organic membrane and the acceptor phase. Factors relevant to the enrichment factors (EFs) were investigated. Under the optimized condition (DP: 100 mL of 0.1 M NaOH with 2 M Na2SO4; organic phase: di-n-hexyl with 8% trioctylphosphine oxide (TOPO); AP: 10 μL of 8 M HCl; extraction time of 80 min), the obtained EFs were 405–2000, dynamic linear ranges were 5–200 μg/L (R > 0.9976), and limits of detection were 0.5–1.5 μg/L. The presence of humic acid (0–25 mg/L dissolved organic carbon) had no significant effect on the extraction efficiency. The proposed procedure worked very well for real environmental water samples with microgram per liter level of analytes, and good spike recoveries (80–103%) were obtained.  相似文献   

8.
A simple, precise, and accurate hydrophilic interaction liquid chromatographic (HILIC) method has been developed for the determination of five aromatic amines in environmental water samples. Chromatography was carried out on a bare silica column, using a mixture of acetonitrile and a buffer of NaH2PO4–H3PO4 (pH 1.5, containing 10 mM NaH2PO4) (85:15, v/v) as a mobile phase at a flow rate of 1 mL min−1. Aromatic amines were detected by UV absorbance at 254 nm. The linear range of amines was good (r2 > 0.998) and limit of detection (LOD) within 0.02–0.2 mg L−1 (S/N = 3). The retention mechanism for the analytes under the optimum conditions was determined to be a combination of adsorption, partition and ionic interactions. The proposed method was applied to the environmental water samples. Aromatic amines were isolated from aqueous samples using solid-phase extraction (SPE) with Oasis HLB cartridges. Recoveries of greater than 75% with precision (RSD) less than 12% were obtained at amine concentrations of 5–50 μg L−1 from 100 mL river water and influents from a wastewater treatment plant (WWTP). The present HILIC technique proved to be a viable method for the analysis of aromatic amines in the environmental water samples.  相似文献   

9.
A novel method of microemulsion electrokinetic chromatography (MEEKC) coupled with hollow fiber-liquid phase microextraction (HF-LPME) was developed for determination of six aromatic amines including 4-methylaniline, 3-nitroaniline, 2,4-dimethylaniline, 4-chloroaniline, 3,4-dichloraniline and 4-aminobiphenyl. Baseline separation of six aromatic amines was achieved within 8 min by using the microemulsion buffer containing a 10 mM borate buffer at pH 9.0, 0.8% (v/v) ethyl acetate as oil droplets, 60 mM sodium cholate as surfactant, 5.0% (v/v) 1-butanol as co-surfactant. The influence factors relevant to the HF-LPME process were systemically investigated. The obtained enrichment factors were ranged between 70 and 157 in a 30 min extraction time, and the limits of detection ranged between 0.0021 and 0.0048 μg/mL. This purposed method was successfully applied for the analysis of aromatic amines in water sample and the recoveries were ranged from 87.2% to 99.8%.  相似文献   

10.
A high resolution liquid chromatographic method is described for determination of low molecular weight (LMW) aliphatic amines in environmental waters. The analytes after isolation are derivatized by fluram and separated with isocratic elution on octyl (C8) column, followed by fluorimetric detection in 395/495 nm. Different isolation procedures such as octadecylsilane (ODS) and strong cation exchanger (SCX) solid phase extraction (SPE) cartridges and Amberlite CG-120 resin were evaluated. The quantitative characteristics such as recovery, linear dynamic range, correlation coefficient, limit of detection (LOD), and relative standard deviation (RSD) are presented. Using this method, aliphatic amines were analyzed in rain and tap water as well as in waste water.  相似文献   

11.
Summary On-line solid-phase extraction (SPE) coupled with reversed-phase liquid chromatography and UV detection at 254 nm has been used for the determination of trace-level polycyclic aromatic hydrocarbons (PAH) in soil extracts. Five commercially available adsorbents (C8, C18, PLRP-S, PRP-1, and Bond-Elut Env) were evaluated. Results showed that recovery of the PAH decreased with increasing molecular weight, because of their poorer solubility. Recovery of high-molecular-weight PAH was significantly improved by addition of 10% (v/v) acetonitrile to the sample before loading of the SPE adsorbent. PAH recovery ranged from 64.0 to 108% when a 50 mL sample spiked with 1 μg L−1 was applied to these adsorbents. Determination of PAH was possible with detection limits below 0.05 μg L−1, which corresponds to 0.2 μg kg−1 soil. The method was successfully used to determine PAH in soil extracts.  相似文献   

12.
建立了固相萃取、毛细柱气相色谱-质谱、内标标准曲线法使用选择离子(SIM)监测采集数据定量分析水中硝基苯类有机化合物的分析方法.通过对固相萃取柱的选择、固相萃取条件(样品溶液的pH、上样速率、上样体积、洗脱液选择及配比)的优化,得出了最佳实验条件.始漏体积达1.5 L.回收率大于80%.检出限为0.015~0.045 μg/L.RSD在1.1%~5.9%之间.  相似文献   

13.
丘秀珍  郭会时  陈步青 《色谱》2013,31(8):809-812
建立了固相萃取-微乳液相色谱法同时测定环境水体中的苯酚、双酚A (BPA)、2,4-二氯苯酚3种酚类化合物的检测方法。水样加酸酸化后,经C18固相萃取小柱富集净化,用微乳液相色谱法测定3种目标物的含量。在Inertsil C18色谱柱(150 mm×4.6 mm, 5 μm)上以微乳(3.0%十二烷基硫酸钠(SDS)-6.0%正丁醇-0.8%正庚烷-90.2%(水+0.5%HAc))和乙腈作为流动相进行梯度洗脱,流速1.0 mL/min,检测波长280 nm。结果表明,苯酚、双酚A、2,4-二氯苯酚的检出限(S/N=3)依次为0.74、8.0、8.0 μg/L,线性范围在0.1~10 mg/L范围内,相关系数(r)均大于0.999。将3种酚类化合物定量加到空白水样中,苯酚、双酚A、2,4-二氯苯酚的加标回收率分别为82.7%、87.8%、82.6%,其RSD均小于5%(n=6)。对环境水样的酚类化合物分析也取得了良好的加标回收率,其值均在85.7%~113.2%之间。结果表明,该方法准确可靠、灵敏度高,适用于环境水体中酚类化合物的检测。  相似文献   

14.
Summary The eleven Environmental Protection Agency (EPA) priority phenolic compounds have been determined by solid-phase extraction (SPE) coupled on-line to supercritical-fluid chromatography (SFC) with diodearray detection. The variables affecting chromatographic separation were optimized and the analytes were separated at 40 °C in two diol columns connected in series; a gradient of methanol, as modifier, and CO2 was used as mobile phase. Under these conditions, all the compounds studied were separated to baseline in less than 13 min. PLRP-S and LiChrolut EN were tested as sorbents in a 10×3 mm i.d. laboratory-packed precolumn for solid-phase extraction. An ion-pair reagent, tetrabutylammonium bromide (TBA), was used in the extraction process to increase break-through volumes. The performance of the method was checked with tap and river waters and the pre-concentration of 20 mL of sample in a PLRP-S pre-column enabled phenolic compounds to be determined at low μg L−1 levels with limits of detection ranging between 0.4 and 2 μg L−1. The repeatability and reproducibility between days (n=3) for real samples spiked at 10 μg L−1 were lower than 10%.  相似文献   

15.
Guo P  Guan Z  Wang W  Chen B  Huang Y 《Talanta》2011,84(2):587-592
In this paper, the potential use of multiwalled carbon nanotubes (MWCNTs) as solid phase extraction (SPE) adsorbent was evaluated for preconcentration of linear alkylbenzene sulfonates (LAS) using ion-pair (IP)-SPE with tetrabutylammonium hydroxide (TBAH). The LAS homologues present in the aqueous sample were ion-paired with TBAH and the solution was passed through the MWCNT cartridges. The analytes retained in the cartridge were eluted with methanol and the concentrated methanol extract was analysed by HPLC-UV. In order to obtain the satisfactory recovery of LAS homologues, various parameters including the type and amount of the ion-pair reagents, the desorption and enrichment conditions such as the effect of eluent and its volume, pH, the flow rate, the ultrasonic time of sample, and the volume of sample solution were systematically optimized. Under the optimal conditions, LAS homologues could be easily extracted by the proposed SPE cartridge. The favorable limits of detection (LOD) for LAS homologues were in the range from 0.02 to 0.03 μg L−1, and the relative standard deviations (RSDs) were 1.55-2.54% for 10 μg L−1 LAS (n = 6). The proposed method has been successfully applied for the analysis of LAS homologues in aqueous environmental samples. A comparison study with ion-pair solid extraction on MWCNTs, C8 and C18 as adsorbents for LAS demonstrated that ion pair-based solid extraction on MWCNTs adsorbent was advantageous over C8 and C18, the widely used traditional adsorbents.  相似文献   

16.
In this study, a practicable and effective analytical method based on solid-phase-extraction and reversed-phase liquid chromatography with fluorescence detection (SPE-LC-FLD) was developed and partially validated for routine analysis of eight FQs in wastewater at the trace level. Different SPE materials, pH conditions and eluents were modified to find an economic and effective SPE conditions. In our work, it is the first time that well-known commercially available SPE sorbent are compared to ‘generic’ cheap SPE sorbent. Aqueous samples (pH 2–3) were extracted using Anpel? MEP cartridges where they were subsequently eluted by 6?mL of 2% formic acid in MeOH. The aqueous extracts were analysed by gradient elution LC-FLD, whose initial mobile phase was composed of ACN and 10?mmol?L?1 tetrabutyl ammonium bromide (4/96, v/v, pH 3). The LODs and LOQs of the wastewater were as low as 0.32–2.12?ng?L?1 and 1.07–7.07?ng?L?1, respectively. The precisions of the overall method (RSD, n?=?3) using wastewater were below 10%. The method was used to quantify FQs in influents and effluents of several typical sewage treatment plants (STPs) in Shanghai. The extraction recoveries of 100?mL influent, 500?mL effluent and 500?mL of river water samples were between 88.6 and 102.6%, 79.2 and 109.2%, 80.0 and 105.5% and 87.4 and 99.4%, respectively. FQs of interest except sarafloxacin were identified in the influents, effluents and river waters with concentrations varying from 0.012–1.163?µg?L?1, 0.003–0.291?µg?L?1, and 0.002–0.040?µg?L?1, respectively. The method can serve as a tool to obtain detailed information on occurrence, behaviour and fate of FQs in the aquatic environment. Occurrence of FQs detected in summer is higher than in spring at STPs, and those detected in the suburban area are less than those in the urban area. Complete removal of FQs is not achieved from the STPs, indicating domestic wastewater and STP discharge is the source of FQs in the surface water.  相似文献   

17.
Summary A suitable method for the determination of 16 biogenic amines in wine has been developed. The method involves clean-up of wine samples using ion-exchange cartridges and a preconcentration step, under controlled vacuum, before derivatization of the amines by treatment with phthalaldehyde (PA) and reversedphase HPLC with gradient elution and fluorimetric detection. Linearity of response was obtained for all the biogenic amines from 100 g L–1 to mg L–1. Limits of detection for the amines were similar for all PA-derivatives (25–50 g L–1) and the quantitation limits were about 0.1 mg L–1. After clean-up and preconcentration, the concentration levels increased 10-fold for all amines except putrescine and cadaverine, which gave poor recovery by this method unlike the rest which gave recoveries of almost 90%. The overall process was successfully applied to identify and quantify biogenic amines in several red wines from the Tarragona region.  相似文献   

18.
液相微萃取-离子色谱法测定污水中痕量芳香胺   总被引:1,自引:0,他引:1  
Zhu Y  Zhu Y  Wang L 《色谱》2012,30(4):345-349
基于中空纤维液相微萃取技术,建立了河流污水中两种芳香胺类物质(邻甲苯胺和对氯苯胺)的离子色谱分析方法。采用中空纤维液相微萃取和离子色谱联用技术,对中空纤维萃取条件进行优化。优化的萃取条件:萃取溶剂为正辛醇,供体相中NaOH的浓度为0.01mol/L, NaCl的浓度为500g/L,接受相中HCl的浓度为0.1 mol/L,搅拌速度为430r/min,萃取时间为30min,在优化条件下,邻甲苯胺的富集倍数为88倍,对氯苯胺的富集倍数为124倍。供体相中邻甲苯胺和对氯苯胺的浓度在0.005–0.1mg/L范围内成良好线性,相关系数为0.9998-0.9999 ,检出限为0.2-0.5μg /L,相对标准偏差为0.85-3.38 %。结论:这种方法操作简单,环境友好,提高了离子色谱检测芳香胺类物质的灵敏度。  相似文献   

19.
Shao B  Peng Z  Yang H  Wu G  Yao Y  Wan K 《色谱》2011,29(8):755-761
建立了固相萃取-高效液相色谱同时测定传统禽肉制品中9种杂环胺类化合物(HAAs)(包括2-氨基-3-甲基咪唑并[4,5-f]喹啉、2-氨基-3,4-二甲基咪唑并[4,5-f]喹啉、2-氨基-3,8-二甲基咪唑并[4,5-f]喹喔啉、2-氨基-3,4,8-三甲基咪唑并[4,5-f]喹喔啉、2-氨基-1-甲基-6-苯基-咪唑并[4,5-b]吡啶、3-氨基-1-甲基-5H-吡啶并[4,3-b]吲哚、3-氨基-1,4-二甲基-5H-吡啶并[4,3-b]吲哚、9H-吡啶并[4,3-b]吲哚、1-甲基-9H-吡啶并[4,3-b]吲哚)含量的分析方法。经过条件优化,肉样选用乙酸乙酯进行提取,提取液经丙基磺酸(PRS)和C18固相萃取小柱净化,采用TSK-gel ODS-80TM色谱柱,以乙腈和0.05 mol/L醋酸-醋酸铵缓冲液(pH 3.4)为流动相进行梯度洗脱分离,紫外-荧光检测器串联方式对目标化合物进行检测。通过波长扫描,确定紫外检测波长为263 nm,荧光激发波长/发射波长随时间切换程序为: 0~21 min, 300 nm/440 nm; 21~23.8 min, 315 nm/410 nm; 23.8~35 min, 265 nm/410 nm。在上述条件下,9种HAAs在35 min内实现基线分离。3个加标水平的平均回收率为60.47%~90.55%(n=6),相对标准偏差(RSD)为0.49%~9.74%(n=6),检出限(以信噪比为3计)为0.1~3.6 μg/kg。该方法简便快速、结果准确、灵敏度高,可作为测定传统禽肉制品中多种杂环胺类化合物的有效方法。  相似文献   

20.
A dispersive liquid–liquid microextraction procedure coupled with GC‐MS is described for preconcentration and determination of banned aromatic amines from textile samples. Experimental conditions affecting the microextraction procedure were optimized. A mixture of 30 μL chlorobenzene (extraction solvent) and 800 μL ACN (disperser solvent), 5 min extraction time, and 5 mL aqueous sample volume were chosen for the best extraction efficiency by the proposed procedure. Satisfactory linearity (with correlation coefficients >0.9962) and repeatability (<9.78%) were obtained for all 20 aromatic amines; detection limits attained were much lower than the standardized liquid–liquid method. The proposed method has advantages of being quicker and easier to operate, and lower consumption of organic solvent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号