首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new strategy for trace analysis was proposed by preparing a molecularly imprinted polymer (MIP) sensor. The template molecules of clopyralid were determined based on “gate-controlled” electrochemiluminescence (ECL) measurement. A dense polymer film was electropolymerized on an electrode surface to fabricate the MIP–ECL sensor. The process of template elution and rebinding acted as a gate to control the flux of probes, which pass through the cavities and react on the electrode surface. ECL measurement was conducted in the luminol–H2O2 system. A linear relationship between ECL intensity and clopyralid concentrations in the range of 1?×?10?9 mol/L to 8?×?10?7 mol/L exists, and the detection limit was 3.7?×?10?10 mol/L. The prepared sensor was used to detect clopyralid in vegetables. Recoveries of 97.9 % to 102.9 % were obtained. The sensor showed highly selective recognition, high sensitivity, good stability, and reproducibility for clopyralid detection.  相似文献   

2.
In this research, a new strategy for construction of a development potentiometric carbon paste Zn2+-ion selective electrode based on a novel nano-sensing layer is suggested. The proposed nano-sensing layer was prepared with the addition of a synthesised Zn2+-ion imprinted polymer nanoparticles ‘as an efficient sensing agent’ into the carbon paste matrix consisting of graphite powder, nanographene-composite ‘graphene nanosheets decorated with silver nanoparticles’ and 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ‘ an ionic liquid ’, as the conducting binder. Under the optimised experimental conditions, the suggested nanographene-composite potentiometric sensor presented a low detection limit of 1.93 × 10?1 μg L?1 and a linear analytical range from 2.62 × 10?1 to 6.54 × 105 μg L?1 with an excellent Nernstian slope of 29.80 mV decade?1. The proposed zinc selective sensor was successfully applied for the highly sensitive determination of trace amounts of Zn2+ in environmental and biological samples with satisfactory results.  相似文献   

3.
A sensitive and selective imprinted electrochemical sensor for the determination of aflatoxin B1 (AFB1) was constructed on a glassy carbon electrode by stepwise modification of functional multiwalled carbon nanotubes (MCNTs), Au/Pt bimetallic nanoparticles (Au/PtNPs), and a thin imprinted film. The fabrication of a homogeneous porous poly o-phenylenediamine (POPD)-grafted Au/Pt bimetallic multiwalled carbon nanotubes nanocomposite film was conducted by controllable electrodepositing technology. The sensitivity of the sensor was improved greatly because of the nanocomposite functional layer; the proposed sensor exhibited excellent selectivity toward AFB1 owing to the porous molecular imprinted polymer (MIP) film. The surface morphologies of the modified electrodes were characterized using a scanning electron microscope. The performance of the imprinted sensor was investigated by cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy in detail. A linear relationship between the sensor response signal and the logarithm of AFB1 concentrations ranging from 1?×?10?10 to 1?×?10?5 mol L?1 was obtained with a detection limit of 0.03 nmol L?1. It was applied to detect AFB1 in hogwash oil successfully.  相似文献   

4.
A novel molecularly imprinted sensor was firstly prepared based on a carbon nanotubes/graphene composite modified carbon electrode (MIPs/CNT/GP/CE) for the selective determination of bovine serum albumin. The molecularly imprinted sensor was tested by differential pulse voltammetry (DPV) to investigate the relationship between the response current and bovine serum albumin concentration. The results showed that a wide linear range (1.0×10?4 to 1.0×10?10 g mL?1) for the detection of bovine serum albumin with a low detection limit of 6.2×10?11 g mL?1 for S/N=3 was obtained. The novel imprinted sensor exhibited high selectivity, sensitivity, and reproducibility, which provided an applicable way for sensor development.  相似文献   

5.
A novel electrochemical sensor for the determination of bisphenol A (BPA) was fabricated by block polyelectrolyte composite films, which composed of diblock polyelectrolyte poly (2-hydroxyethyl methacrylate)-b-poly (2-(dimethylamino) ethyl methacrylate) (PHEMA-b-PDMAEMA, noted as PHD in the later content) and multi-walled carbon nanotubes (MWCNTs). The tertiary amino groups of PDMAEMA can be protonated at physiological pH. The protonated PDMAEMA can thus interact with the negatively charged BPA through electrostatic attraction to increase the BPA sorption capacity and enhance the ability for highly sensitive detection of BPA. The PHD/MWCNTs composite films combine the electrocatalytic property of MWCNTs and the electrostatic attraction of protonated PHD. Because of the above-mentioned excellent property of the composite films, the PHD/MWCNTs/glassy carbon electrode exhibited good electrocatalytic activity to electrooxidation of BPA. The wide linear response range of the BPA sensor was from 4.56 × 10?5 g L?1 to 2.28 × 10?2 g L?1 with a lower detection limit of 2.28 × 10?6 g L?1 (S/N = 3) and high sensitivity 2442.86 μA L g?1 cm?2. The current reached the steady-state current with a shorter response time less than 4 s. The proposed method was successfully applied to determine BPA in real samples (PVC food package, milk, tap water and pond water) and satisfactory results were obtained. These results indicated that the block polyelectrolyte composite have potential applicability of the BPA sensor.  相似文献   

6.
《Analytical letters》2012,45(6):1033-1045
The amoxicillin-imprinted polymer was synthesized with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The binding characteristic of the imprinted polymer to amoxicillin was evaluated by equilibrium binding experiments. Using the imprinted polymer as recognition material, 3-(3′-nitrophenyl)-5(2′-sulfonylphenylazo)-rhodanine (4NRASP) was synthesized by the authors and was used as chemiluminescence (CL) reagent. A novel chemiluminescence (CL) sensor for the determination of amoxicillin was developed based on the CL reaction of amoxicillin with potassium permanganate in an acidic medium. The sensor displayed excellent selectivity and high sensitivity. The linear response range of the sensor was from 5.0 × 10?9 to 1.0 × 10?6 g · mL?1 (r = 0.9985) and the detection limit was 1.3 × 10?9 g · mL?1. The relative standard deviation for the determination of 1.0 × 10?7 g · mL?1 amoxicillin solution was 1.7% (n = 11). The sensor was applied to the determination of amoxicillin in urine samples with satisfactory results.  相似文献   

7.
A new molecularly imprinted electrochemical luminescence sensor (MIP‐ECL sensor) was developed for isoproturon (IPU) determination based on the competition reaction between IPU and glucose oxidase labeled IPU (GOD‐IPU). After competition, hydrogen peroxide produced by residual GOD‐IPU on the MIP reacted with luminol to emit electrochemiluminescence (ECL) signal. The ECL intensity decreased when the GOD‐IPU molecules were replaced by IPU molecules in the samples. IPU could be determined in the concentration range from 9×10?11 mol/L to 5.1×10?9 mol/L with a detection limit of 3.78×10?12 mol/L. Water samples were assayed and recoveries ranging from 98.5 % to 102.1 % were obtained.  相似文献   

8.
We have developed a “turn on” model of an electrochemiluminescence (ECL) based assay for lead ions. It is based on the formation of a G-quadruplex from an aptamer labeled with quantum dots (QDs) and placed on an electrode modified with of graphene and gold nanoparticles (AuNPs). A hairpin capture probe was labeled with a thiol group at the 5′-end and with an amino group at the 3′-end. It was then self-assembled on the electrode modified with graphene and AuNPs. In the absence of Pb(II), the amino tag on one end of the hairpin probe is close to the surface of the electrode and therefore unable to interact with the QDs because of steric hindrance. The ECL signal is quite weak in this case. If, however, Pb(II) is added, the stem-loop of the aptamer unfolds to form a G-quadruplex. The amino group at the 3′-end will become exposed and can covalently link to a carboxy group on the surface of the CdTe QDs. This leads to strong ECL. Its intensity increases (“turns on”) with the concentration of Pb(II). Such a “turn-on” method does not suffer from the drawbacks of “turn-off” methods. ECL intensity is linearly related to the concentration of Pb(II) in the 10 p mol·L?1 to 1 n mol·L?1 range, with a 3.8 p mol·L?1 detection limit. The sensor exhibits very low detection limits, good selectivity, satisfying stability, and good repeatability.
Figure
A “turn on” model of ECL method was developed based on G-quadruplex of Graphene/AuNPs of aptamer probe by using quantum dots as label. ECL intensity is increased with the increase of Pb2+ concentration. The responsive ECL intensity was linearly related to the Pb2+ concentration in the range of 1.0?×?10?11?~?1.0?×?10?9 mol·L?1, with a detection limit of 3.82?×?10?12 mol·L?1.  相似文献   

9.
《Analytical letters》2012,45(5):803-817
Prussian blue (PB)-multi-walled carbon nanotubes (MWCNTs) modified screen-printed electrodes (SPEs) were used to immobilize enzyme acetylcholinesterase (AChE) for carbamate insecticide sensing. The synthesized hybrid PB-MWCNTs had high stability at pH values in the range of 5–10 and presented a porous and homogeneous microenvironment to entrap enzyme molecules. The generated hybrids not only acted as carriers of acetyl cholinesterase, but also promoted electron-transfer reactions because of the synergistic effects between MWCNTs and PB. Under the optimal conditions, the response of the sensor was proportional to acetylthiocholine (ATCh) concentrations ranging from 0.1 mM to 0.6 mM, with a sensitivity of 21.97 µA · mM?1 · cm?2. The sensors were further used to detect pesticides, and the inhibition rate of pirimicarb was proportional to the logarithm of its concentration ranging from 1.0 × 10?6 to 1.0 g · L?1, with a limit of detection (LOD) equal to 5.32 × 10?8 g · L?1. In order to evaluate the performance of the detection system, the sensors were applied to determine pirimicarb in water samples and exhibited high sensitivity and good stability. The detection system is fast, simple for analysis of pirimicarb in environmental samples, and could provide a semi-automated analytical system through further improvement in biosensor arrays.  相似文献   

10.
A modified glassy carbon electrode was prepared as an electrochemical voltammetric sensor based on molecularly imprinted polymer film for tartrazine (TT) detection. The sensitive film was prepared by copolymerization of tartrazine and acrylamide on the carbon nanotube-modified glassy carbon electrode. The performance of the imprinted sensor was investigated by cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy in detail. Under the optimum conditions, two dynamic linear ranges of 8?×?10?8 to 1?×?10?6?mol?L?1 and 1?×?10?6 to 1?×?10?5?mol?L?1 were obtained, with a detection limit of 2.74?×?10?8?mol?L?1(S/N?=?3). This sensor was used successfully for tartrazine determination in beverages.  相似文献   

11.
《Analytical letters》2012,45(7):1117-1131
A molecularly imprinted electrochemical sensor was fabricated based on a gold electrode modified by chitosan-multiwalled carbon nanotube composite (CS-MWCNTs) multilayer films and gold nanoparticles (AuNPs) for convenient and sensitive determination of oxytetracycline (OTC). The multilayer of CS-MWCNTs composites and AuNPs were used to augment electronic transmission and sensitivity. The molecularly imprinted polymers (MIPs) were synthesized using OTC as the template molecule and o-phenylenediamine (OPD) as the functional monomer. They were modified on a gold electrode by electropolymerization. The electrochemical behavior of OTC at the imprinted sensor was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), and amperometry. The molecularly imprinted sensor showed high selectivity and excellent stability toward OTC. The linear range was from 3.0 × 10?8 to 8.0 × 10?5 mol/L, with a limit of detection (LOD) of 2.7 × 10?8 mol/L (S/N = 3). The developed sensor showed good recovery in spiked samples analysis.  相似文献   

12.
Electrogenerated chemiluminescence (ECL) for DNA hybridization detection is demonstrated based on DNA that was self-assembled onto a bare gold electrode and onto a gold nanoparticles modified gold electrode. A ruthenium complex served as an ECL tag. Gold nanoparticles were self-assembled on a gold electrode associated with a 1,6-hexanedithiol monolayer. The surface density of single stranded DNA (ssDNA) on the gold nanoparticle modified gold electrode was 4.8?×?1014 molecules per square centimeter which was 12-fold higher than that on the bare gold electrode. Hybridization was induced by exposure of the target ssDNA gold electrode to the solution of ECL probe consisting of complementary ssDNA tagged with ruthenium complex. The detection limit of target ssDNA on a gold nanoparticle modified gold electrode (6.7?×?10?12 mol L?1) is much lower than that on a bare gold electrode (1.2?×?10?10 mol L?1). The method has been applied to the detection of the DNA sequence related to cystic fibrosis. This work demonstrates that employment of gold nanoparticles self-assembled on a gold electrode is a promising strategy for the enhancement of the sensitivity of ECL detection of DNA.  相似文献   

13.
We report a rapid and simple method for sensing estradiol by electro‐oxidation on a multi‐walled carbon nanotube (MWCNT) and gold nanoparticle (AuNP) modified glassy carbon electrode (GCE). Compared with a bare GCE, AuNP/GCE and MWCNT/GCE, the composite modified GCE shows an enhanced response to estradiol in 0.1 M phosphate buffer solution. Experimental parameters, including pH and accumulation time for estradiol determination were optimised at AuNP/MWCNT/GCE. A pH of 7.0 was found to be optimum pH with an accumulation time of 5 minutes. Estradiol was determined by linear sweep voltammetry over a dynamic range up to 20 %mol L?1 and the limit of detection was estimated to be 7.0×10?8 mol L?1. The sensor was successfully applied to estradiol determination in tap water and waste water.  相似文献   

14.
In this study, a new sensitised spectrofluorometric method was presented as a probe sensor for hypochlorite analysis in oral and tap water samples. By capping L-tyrosine (Tyr) on ZnSe nanoparticles, stable quantum dots (QDs) were obtained. In comparison with Tyr, the fluorescence (FL) emission of Tyr-capped ZnSe is enhanced and shifted to greater wavelength, which causes to enhance the sensitivity for the determination of hypochlorite. Based on the FL quenching of the Tyr-capped ZnSe QDs, hypochlorite concentration was detected at buffering pH of 7 in the range of 5.15 × 10?5?2.57 × 10?2 g L?1. Relative standard deviation and detection limit were found to be 0.83% and 2.06 × 10?5 g L?1, respectively. In comparison with the other methods of hypochlorite determination, this method is simple, fast and inexpensive, with low sample volume consumption. It also exhibits a good selectivity.  相似文献   

15.
《Analytical letters》2012,45(2):381-392
Abstract

A selective molecular imprinting-chemiluminescence sensor is developed for the determination of prulifloxacin by using a prulifloxacin-imprinted polymer as recognition material and the cerium(IV)/sodium thiosulfate/prulifloxacin chemiluminescence reaction as the detection system. The linear response range of the sensor is from 8.0 × 10?8 to 7.0 × 10?6 mol L?1 with a detection limit of 2.0 × 10?8 mol L?1. The relative standard deviation for 5.0 × 10?7 mol L?1prulifloxacin solution is 1.3% (n = 7). This sensor has been applied to the determination of prulifloxacin in urine samples, and the results obtained are satisfactory.  相似文献   

16.
A novel enzyme-free electrochemical sensor for H2O2 was fabricated by modifying an indium tin oxide (ITO) support with (3-aminopropyl) trimethoxysilane to yield an interface for the assembly of colloidal gold. Gold nanoparticles (AuNPs) were then immobilized on the substrate via self-assembly. Atomic force microscopy showed the presence of a monolayer of well-dispersed AuNPs with an average size of ~4 nm. The electrochemical behavior of the resultant AuNP/ITO-modified electrode and its response to hydrogen peroxide were studied by cyclic voltammetry. This non-enzymatic and mediator-free electrode exhibits a linear response in the range from 3.0?×?10?5 M to 1.0?×?10?3 M (M?=?mol?·?L?1) with a correlation coefficient of 0.999. The limit of detection is as low as 10 nM (for S/N?=?3). The sensor is stable, gives well reproducible results, and is deemed to represent a promising tool for electrochemical sensing.
Figure
AuNPs/ITO modified electrode prepared by self-assembly method exhibit good electrocatalytic activity towards enzyme-free detection H2O2. The linear range of typical electrode is between 3.0?×?10?5 M and 1.0?×?10?3 M with a correlation coefficient of 0.999 and the limit detection is down to 1.0?×?10?8 M.  相似文献   

17.
A magnetic molecularly imprinted polymer (MMIP) was fabricated and used as the sorbent for the MMIP-dispersive solid-phase microextraction of fenitrothion prior its determination by high-performance liquid chromatography equipped with an ultraviolet detector. The MMIP was prepared using functionalized Fe3O4 nanoparticles as the magnetic supporter. Methacrylic acid, ethylene glycol dimethacrylate and fenitrothion were used as the functional monomer, the cross-linker and the template, respectively. The properties of the resultant MMIP were evaluated using X-ray diffraction spectroscopy, Fourier transform infrared spectroscopy and scanning electron microscopy. The sorbent exhibited high selectivity and affinity toward fenitrothion compared to other organophosphate pesticides with the maximum adsorption capacity of 31.5 mg g?1. The effective variables on the extraction were optimized by univariable and MultiSimplex methods. The calibration curve exhibited linearity over the concentration range of 0.3–50.0 μg L?1 with the limit of detection of 0.1 μg L?1. The relative standard deviations at 10.0 μg L?1 level of FNT (n = 5) for intra- and inter-day assays were 1.6 and 3.1%, respectively. The proposed method was successfully used for the determination of trace amounts of FNT in food and water samples.  相似文献   

18.
ABSTRACT

A molecularly imprinted electrochemical sensor for the rapid detection of the anti-parasitic drug Secnidazole (SCZ) is reported. In this work, the build electrochemical sensor was based on a carbon paste electrode (CPE) modified with multi-wall carbon nanotubes (MWCNTs) and boron-embedded duplex molecularly imprinted composite membranes (B-DMICMs), that significantly increased the efficiency of the sensor for the detection of template molecule SCZ. Density functional theory (DFT) was employed to study the interactions between the template and monomers to select appropriate functional monomers for rational design of the B-DMICMs.The optimal experimental conditions were optimised for the factors affecting the performance of the sensor. Under the optimal conditions, the reduction peak currents of SCZ by differential pulse voltammetry increased linearly with SCZ concentration in the range from 3.0 × 10?4 to 1.0 × 1.0?6 mol L?1 and 1.0 × 1.0?6 to 1.91 × 10?8 mol L?1 with a detection limit of 1.72 × 10?8 mol L?1 for secnidazole, which is significantly lower than those in the currently used methods and in previous reports. This method offers low cost, sensitive and effective determination of SCZ and can potentially be used for detection of SCZ in pharmaceutical and biological samples with good precision and accuracy.  相似文献   

19.
A new man-tailored biomimetic sensor for sulfamethoxazole host–guest interactions and potentiometric transduction is presented. The host cavity was shaped on a polymeric surface assembled with methacrylic acid monomers by radical polymerization. Molecularly imprinted particles (MIP) were mixed with graphite powder, paraffin oil and ionic site. Using the Taguchi method, this study analyzed the optimum conditions for preparing the carbon paste electrode. The controllable factors used in this study consisted the weights of (1) MIP, (2) paraffin oil, (3) graphite, and (4) the ionic site. The percentage contribution of each controllable factor was also determined. MIP-modified electrode exhibited a Nernstian response (57.2 mVdecade?1) in a wide concentration range of 6.0 × 10?8 to 3.1 × 10?3 mol L?1 with a lower detection limit of 3.5 × 10?9 mol L?1. The sensor was successfully applied to the determination of sulfamethoxazole concentrations in foods and plasma.  相似文献   

20.
In this work, we described an electrochemical sensor using a nanocomposite based on graphene oxide (GO), silver nanoparticles (AgNP), and disordered mesoporous silica (SiO2), which was used for the determination of bisphenol A in water samples. Initially, the hybrid material SiO2/GO was synthesized via sol-gel process, subsequently decorated with AgNP with an approximate 20 nm particle size prepared directly on the surface of the SiO2/GO using N, N-dimethylformamide (DMF) as an agent reducer. A glassy carbon electrode was modified with SiO2/GO/AgNP and used in developing a sensitive electrochemical sensor for the determination of bisphenol A in phosphate buffer 0.1 mol L?1 (pH 7.0). The detection limit was 45.2 nmol L?1 with a linear response range between 1.0 × 10?7 and 2.6 × 10?6 mol L?1 and a sensitivity of 1.27 × 10?7 A mol?1 L. Finally, the optimized electrochemical sensor was used for the quantitation of endocrine interfering in natural waters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号