首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A simple and sensitive GC-EI-MS method using solvent extraction and evaporation was developed for the determination of olanzapine concentrations in plasma samples. Because olanzapine and promazine, which was used as the internal standard (IS), are nitrogenous bases, they can adsorb to the weakly acidic silanol groups on the surfaces of glass centrifuge tubes during solvent extraction and evaporation. Silylation of the glass tubes, addition of triethylamine (TEA), and use of a sample solution with a basic pH could prevent adsorption loss. The extraction method involved mixing plasma (500 μL) in a silylated glass tube with a promazine solution (2 μg/mL, 25 μL) in methanol containing 1% TEA. After addition of aqueous sodium carbonate (0.5 mol/L, pH 11.1, 1 mL) and extraction into 3 mL of dichloromethane/n-hexane (1:1, v/v) containing 1% TEA, the organic phase was evaporated to dryness in a silylated glass tube. The residue was dissolved in ethyl acetate containing 1% TEA (50 μL). For GC-EI-MS analysis, the calibration curves of olanzapine in human plasma were linear from 0.5 to 100 ng/mL. Intra- and interday precisions in plasma were both less than 7.36% (coefficient of variation), and the accuracy was between 94.6 and 110% for solutions with concentrations greater than 0.5 ng/mL. The limit of quantification was 0.5 ng/mL in plasma. The assay was applied to therapeutic drug monitoring in samples from three schizophrenic patients.  相似文献   

2.
Free amino acids were quantitatively determined in cerebrospinal fluid (CSF) and plasma samples from patients with aseptic meningitis by a newly developed high performance liquid chromatographic (HPLC) method. The method of analysis was based on precolumn derivatization of orthophthaladehyde in the presence of 2-mercaptoethanol and detection was made at Eex = 340 nm and Eem = 450 nm. The method was sensitive and the limit for detection was less than 1 pmol for most of the amino acids. It took 45 min to separate 26 amino acids with highly reproducible results, giving a coefficient of variance for retention times and integrated areas less than 0.4% and 2%, respectively, after five replicate runs. The results accumulated in 10 patients were compared statistically with 11 age-matched healthy controls. Among the amino acids almost all the neurotransmitter candidates, such as aspartic acid, glutamic acid, glutamine, glycine, tyrosine, phenylalanine and gamma-aminobutyric acid (GABA), were significantly increased in the patients' CSF, whereas arginine and threonine were low. No change was observed in plasma amino acids in patients as compared to healthy controls. The higher levels of most of the neurotransmitters, especially GABA, aspartic acid and glutamic acid, could be used diagnostically in assessing the progression and remission in aseptic meningitis.  相似文献   

3.
A new liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) method with on-line sample clean-up for the determination of telmisartan in human blood plasma is presented. This technique is compared to a previously introduced enzyme-linked immunosorbent assay (ELISA), where fluorescence is used as detection method. For the LC/MS method applying an internal calibration via a deuterated internal standard, the limit of detection was 0.3 ng/mL, the limit of quantification was 0.9 ng/mL and the linear range extended from 0.9 to 1000 ng/mL. Forty-eight plasma samples from four healthy volunteers were analyzed in a pharmacokinetic study to obtain data for the method comparison. As a result, these two new and independent analytical methods for the determination of telmisartan in human blood plasma proved to yield comparable results for the amount of analyte.  相似文献   

4.
为评价盐酸头孢替安酯片在健康人体内的药代动力学特征,应用蛋白沉淀-液相色谱-串联质谱技术建立了灵敏度高、特异性强、快速的健康受试者血浆中头孢替安的分析方法。选用 Waters Symmtry C18色谱柱(50 mm×4.6 mm,5μm),以甲醇和1 mmol/ L 乙酸铵水溶液梯度洗脱,流速1.0 mL/ min。在多反应监测模式(MRM)下,采用电喷雾离子化源,正离子扫描模式下进行定量分析。标准曲线在5.0~5000 ng/ mL 范围内线性关系良好(r>0.99),定量下限为5.0 ng/ mL,方法学验证部分结果均符合生物样本定量测定的要求。本方法快速、灵敏、重现性好,并成功应用于健康受试者盐酸头孢替安酯片药动学研究,同时也为同类药物在人体生物基质中的定量检测提供参考。  相似文献   

5.
A sensitive HPLC/ESIMS method was established for the determination of manidipine in human plasma and pharmacokinetics study. After basified plasma with ammonia, manidipine and the internal standard (IS) (felodipine) were extracted with n-hexane and separated on a Hypersil ODS2 column with a mobile phase of methanol-5 mm ammonium acetate solution containing 0.1% acetic acid (85:15, v/v). MS determination was performed by electrospray ionization in the selected ion monitoring mode. Manidipine was monitored at m/z 611.4 and IS at m/z 384. The assay had a calibration range from 0.2 to 20 ng/mL and a lower limit of quantification of 0.1 ng/mL. The method has been successfully applied to the pharmacokinetic study in healthy volunteers.  相似文献   

6.
A sensitive, rapid and selective liquid chromatography negative electrospray ionization tandem mass spectrometry [LC-(-)ESI-MS-MS] method has been developed and validated for the simultaneous quantification of budesonide (BUD) and its major metabolites, 6beta-hydroxybudesonide (OH-BUD) and 16alpha-hydroxyprednisolone (OH-PRED) in human plasma. The method was validated over a linear range from 0.1 to 10 ng/mL for all three analytes using a solid-phase extraction procedure with 9-fluoro-hydrocortisone as the internal standard. The between-day and within-day coefficients of variation for all compounds were < or =20% at the concentrations of lower limit of quantification and < or =15% at other quality control concentrations. The utility of this assay was demonstrated by monitoring BUD, OH-BUD and OH-PRED plasma concentrations in one healthy subject for 24 h following a 3 mg oral dose of budesonide, administered as a pH modified release capsule (Budenofalk) to healthy volunteers.  相似文献   

7.
A simple and robust analytical method for rapid separation and sensitive quantification of baclofen in human plasma by capillary electrophoresis technique was developed. Electrophoretic separation was optimized and successfully performed using simple sodium tetraborate aqueous solution. Observed detection limit in biological material was 10 ng. Using UV detection at 200 nm excellent linearity (r = 0.999) was observed over the concentration range from 0.025 to 1.0 microg mL(-1). The described method has been validated and applied to the quantitative determination of baclofen in human plasma. The bioavailability of Baclofen (Polpharma) and Lioresal (Novartis) in 18 healthy volunteers was investigated. The results indicate bioequivalence of the reference and Baclofen preparations.  相似文献   

8.
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the determination of quetiapine was developed and validated over the linearity range 1-1500 ng/mL with 0.1 mL of plasma using clozapine as the internal standard. Detection was performed on a triple-quadrupole tandem mass spectrometer using positive electrospray ionization and quantification was performed by selected reaction monitoring mode. The MS-MS ion transitions monitored were m/z 384.1 → 253.1 and 327.0 → 270.0 for quetiapine and clozapine, respectively. The between- and within-run precision was less than 7.44% and accuracy was less than 10.2%. The lower limit of quantification was 1 ng/mL. The extraction recoveries of quetiapine were over 90%. The method is proved to be accurate and specific, and was applied to the pharmacokinetic study in healthy Chinese volunteers.  相似文献   

9.
A method for the separation and quantitative determination of neuroactive amino acids (aspartate, glutamate, citrulline, arginine, glycine, taurine, gamma-aminobutyric acid) and neuroactive amines (noradrenaline, dopamine and serotonin) in a single chromatographic analysis is presented. The method is based on pre-column derivatization with o-phthalaldehyde and tert.-butyl thiol, on-column preconcentration and separation using 50 microns I.D. packed capillary columns, and detection by amperometry. Mass limits of detection are 80-900 amol for all neurotransmitters with RSDs of 0.71 and 4.6% or better for retention time and peak area, respectively. The method was demonstrated by application to the determination of neurotransmitters in microdialysis samples collected from striatum of live rats and tissue samples extracted from butterfly brains.  相似文献   

10.
The release and content of the excitatory amino acid neurotransmitters glutamate and aspartate in rat striatum were determined by liquid chromatography/electrochemistry. This determination was based on precolumn off-line derivatization of the amino acids with o-phthaldialdehyde and 2-mercaptoethanol (OPT/2-MCE), and the adducts formed were separated under isocratic conditions and oxidized on a glassy carbon electrode at moderate potential (+0.6 V). The standard and the extracted glutamate when derivatized with OPT/2-MCE produced similar electrochemical and chromatographic characteristics. The detection limit of glutamate was 0.5 pmol. Depolarization induced by the high potassium medium (40 mmol/L) enhanced the release of glutamate and aspartate from superfused rat striatum, whereas the efflux of glutamine remained unchanged. Perfusion (for 60-70 min) removed 50-80% of the free amino acid content of striatal tissue. The method described here is useful in neurochemical investigations of the brain amino acid neurotransmitters.  相似文献   

11.
A reversed-phase high-performance liquid chromatographic method with electrochemical detection for the quantitative determination of diclofenac potassium in plasma was developed. Naproxen was used as the internal standard. The drug and internal standard were isolated from plasma by extraction with dichloromethane and 2 M hydrochloric acid. Chromatographic separation was performed on a C18 column with methanol-water (68:32, v/v) adjusted to pH 3.2 with phosphoric acid as mobile phase. The oxidation potential for detection was established by constructing a voltammogram for diclofenac. The quantification limit for diclofenac in plasma was 5 ng mL(-1). Linearity of the method was confirmed in the range 5-2000 ng mL(-1), correlation coefficient 0.9998. Within-day relative standard deviations (RSDs) ranged from 0.66 to 14.00% and between-day RSDs from 0.59 to 15.78%. The method was successfully applied for the determination of pharmacokinetic parameters after ingestion of a 50 mg dose of diclofenac. Studies were performed on 18 healthy volunteers of both sexes.  相似文献   

12.
We describe here a simple, sensitive, selective and reproducible assay method for quantitative determination of aspartate, glutamate, serine, glutamine, glycine and gamma-aminobutyric acid in rat brain using reversed-phase high-performance liquid chromatography. The method is based upon formation of phenylthiocarbamyl derivatives of the amino acids. Good resolution of the six amino acids and the internal standard norvaline is achieved within 40 min. Other amino acids which have been reported to be present in rat brain do not interfere with the analysis. Standard curves for each of the amino acids exhibited good linearity (r greater than 0.9993) over the range 0.5-20 nmol. The coefficient of variation for the intra-day and inter-day determinations ranged from 0.4% at the highest to 11% at the lowest concentration limit. Storage of whole brains at -0 degrees C for up to 8 weeks did not affect mean concentrations of the six amino acids.  相似文献   

13.
高效液相色谱-柱前衍生化法测定饲料中的含硫氨基酸   总被引:1,自引:0,他引:1  
Yu S  Feng S  Sun Y  Tang T  Han J  Wang F  Li T 《色谱》2011,29(3):239-243
发展了一种饲料中含硫氨基酸的检测方法。样品经过甲酸氧化,将其中的胱氨酸和蛋氨酸分别氧化为磺基丙氨酸和蛋氨酸砜;再经酸水解后,采用2,4-二硝基氟苯进行柱前衍生化,衍生物经高效液相色谱分析。使用Elite AAK C18色谱柱(250 mm×4.6 mm, 5 μm)分离;以0.05 mol/L乙酸钠和乙腈-水(50:50, v/v)为流动相,梯度洗脱,流速为1.2 mL/min;检测波长为360 nm;柱温为31 ℃。结果表明,胱氨酸在0.4~16.0 mg/L、蛋氨酸在0.7~29.6 mg/L范围内的线性相关系数分别为0.9999、0.9998;胱氨酸和蛋氨酸的定量限(信噪比(S/N)=10)分别为2.6 μg/kg和3.1 μg/kg;3次样品平行测定的胱氨酸和蛋氨酸含量的相对标准偏差(RSD)分别为0.79%和2.56%,加标回收率分别为100.28%~102.00%和105.72%~107.89%。该方法分析成本低,测定结果准确,灵敏度高,符合饲料中含硫氨基酸的检测要求。  相似文献   

14.
The uncertainty of measurement for well-known neurotransmitters like serotonin, noradrenalin and gamma-aminobutyric acid (GABA), glutamate and melatonin hormone with high performance liquid chromatography?fluorescence detection was calculated after the method validation. Two methods were developed for the determination of the neurotransmitters. A derivatization step was performed for the determination of GABA and glutamate. Sensitivity, method detection limit, limit of quantification, linearity, recovery, interday and intraday precision values were calculated. Low detection limit values were obtained especially for the determination of GABA and glutamate. Then, bottom-up approach was used to calculate measurement uncertainty. The critical stages of the method were evaluated. The major sources of the uncertainty budget were calibration curves, stock solution and recovery. The calculated percentage relative uncertainty values for the compounds changed between 10.1 and 16.7.  相似文献   

15.
A new, simple, and reproducible method for determination of carboxylic acid metabolite of clopidogrel in human plasma has been developed. After liquid-liquid extraction in acidic medium with chloroform, samples were quantified on a Nova-pak C(8), 5 microm column using a mixture of 30 mM K(2)HPO(4)-THF-acetonitrile (pH = 3, 79:2:19, v/v/v) as mobile phase with UV detection at 220 nm. The flow rate was set at 0.9 mL/min. Ticlopidine was used as internal standard and the total run time of analysis was about 12 min. The method was linear over the range of 0.2-10 microg/mL of clopidogrel metabolite in plasma (r(2) > 0.999). The within-day and between-day precision values were in the range 1.0-4.8%. The limit of quantification of the method was 0.2 microg/mL. The method was successfully used to study the pharmacokinetics of clopidogrel in healthy volunteers.  相似文献   

16.
A gas chromatographic (GC) method with a rapid and simple sample preparation was developed and validated for determination of prilocaine in human plasma. The validation parameters of linearity, precision, accuracy, recovery, specificity, limit of detection and limit of quantification were studied. The range of quantification for the GC method was 50–300 ng mL?1 in plasma. Intra- and inter-day precision, expressed as the relative standard deviation (RSD) were less than 4.5%, and accuracy (relative error) was better than 8.0% (n = 6). The analytical recovery of prilocaine HCl from plasma has averaged 96.5% and the recovery of internal standard (lidocaine HCl) reached 96.8%. The limit of quantification (LOQ) and the limit of detection (LOD) of the method for plasma were 50 and 40 ng mL?1, respectively. Also the developed and validated method was applied to three healthy volunteers to whom a local anaesthesia with citanest was administered.  相似文献   

17.
A rapid, selective and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed to determine lisinopril in human plasma. Sample pretreatment involved a one-step protein precipitation with methanol of 0.1 mL plasma. Analysis was performed on an Inertsil ODS-3 column (2.1 × 50 mm i.d., 3 μm) with mobile phase consisting of methanol-water (containing 0.2% formic acid; 55:45, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode via an electrospray ionization source. Each plasma sample was chromatographed within 2.5 min. The linear calibration curves for lisinopril were obtained in the concentration range of 1.03-206 ng/mL (r(2) ≥ 0.99) with a lower limit of quantification of 1.03 ng/mL. The intra- and inter-day precisions (relative standard deviation) were not higher than 11%, and accuracy (relative error) was within ±6.8%, determined from quality control samples for lisinopril, which corresponded to the guidance of the Food and Drug Administration. The method described herein was fully validated and successfully applied to the pharmacokinetic study of lisinopril tablets in healthy male volunteers after oral administration.  相似文献   

18.

The ultrahigh-performance liquid chromatography-mass spectrometry (UHPLC/MS) method was optimized and validated for the determination of oxylipins in human plasma using the targeted approach with selected reaction monitoring (SRM) in the negative-ion electrospray ionization (ESI) mode. Reversed phase UHPLC separation on an octadecylsilica column enabled the analysis of 63 oxylipins including numerous isomeric species within 12-min run time. The method was validated (calibration curve, linearity, limit of detection, limit of quantification, carry-over, precision, accuracy, recovery rate, and matrix effect) and applied to 40 human female plasma samples from breast cancer patients and age-matched healthy volunteers (control). Thirty-six oxylipins were detected in human plasma with concentrations above the limit of detection, and 21 of them were quantified with concentrations above the limit of quantitation. The concentrations determined in healthy controls are in a good agreement with previously reported data on human plasma. Quantitative data were statistically evaluated by multivariate data analysis (MDA) methods including principal component analysis (PCA) and orthogonal partial least square discriminant analysis (OPLS-DA). S-plot and box plots showed that 13-HODE, 9-HODE, 13-HOTrE, 9-HOTrE, and 12-HHTrE were the most upregulated oxylipin species in plasma of breast cancer patients.

  相似文献   

19.
A new high-performance liquid chromatographic method is described for the determination of bisoprolol in human plasma. The proposed method was based on the derivatization of bisoprolol with 4-chloro-7-nitro-2,1,3-benzoxadiazole in borate buffer at pH 9.5 to yield a fluorescent product. Chromatographic separation of bisoprolol was achieved by using isocratic elution at a flow rate of 1.2 mL/min on a C18 reversed-phase column (Inertsil, 4 μm, 150 4.6 mm) at 40°C. The mobile phase used for the analysis was methanol-water (70:30, % v/v). Fluorescence detector was used at the excitation and emission wavelengths of 458 and 525 nm, respectively. The method was validated for linearity, limit of detection, limit of quantification, precision, accuracy, recovery and system suitability. The assay was linear over the concentration range of 10-2000 ng/mL. This method was applied in pharmacokinetic studies of bisoprolol preparations in healthy volunteers.  相似文献   

20.
A highly sensitive, simple and selective high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and applied to the determination of bergenin concentration in human plasma. Bergenin and the internal standard (IS) thiamphenicol in plasma were extracted with ethyl acetate, separated on a C(18 )reversed-phase column, eluted with mobile phase of acetonitrile-water, ionized by negative ion pneumatically assisted electrospray and detected in the multi-reaction monitoring mode using precursor --> product ions of m/z 327.1 --> 192 for bergenin and 354 --> 185.1 for the IS, respectively. The linear range of the calibration curve for bergenin was 0.25-60 ng mL(-1), with the lowest limit of quantification of 0.25 ng mL(-1), and the intra/inter-day relative standard deviation (RSD) was less than 10%. The method is suitable for the determination of low bergenin concentration in human plasma after therapeutic oral doses, and has been first and successfully used for its pharmacokinetic studies in healthy Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号