首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Digital microfluidics (DMF), a fluid-handling technique in which picolitre-microlitre droplets are manipulated electrostatically on an array of electrodes, has recently become popular for applications in chemistry and biology. DMF devices are reconfigurable, have no moving parts, and are compatible with conventional high-throughput screening infrastructure (e.g., multiwell plate readers). For these and other reasons, digital microfluidics has been touted as being a potentially useful new tool for applications in multiplexed screening. Here, we introduce the first digital microfluidic platform used to implement parallel-scale cell-based assays. A fluorogenic apoptosis assay for caspase-3 activity was chosen as a model system because of the popularity of apoptosis as a target for anti-cancer drug discovery research. Dose-response profiles of caspase-3 activity as a function of staurosporine concentration were generated using both the digital microfluidic method and conventional techniques (i.e., pipetting, aspiration, and 96-well plates.) As expected, the digital microfluidic method had a 33-fold reduction in reagent consumption relative to the conventional technique. Although both types of methods used the same detector (a benchtop multiwell plate reader), the data generated by the digital microfluidic method had lower detection limits and greater dynamic range because apoptotic cells were much less likely to de-laminate when exposed to droplet manipulation by DMF relative to pipetting/aspiration in multiwell plates. We propose that the techniques described here represent an important milestone in the development of digital microfluidics as a useful tool for parallel cell-based screening and other applications.  相似文献   

2.
Caspase proteases are familiar targets in drug discovery. A common format for screening to identify caspase inhibitors employs fluorogenic or colorimetric tetra-peptide substrates in 96, 384, or 1536 -well microtiter plates. The primary motivation for increasing the number of wells per plate is to reduce the reagent cost per test and increase the throughput of HTS operations. There are significant challenges, however, to moving into or beyond the 1536-well format, such as submicroliter liquid handling, liquid evaporation, increased surface area-to-volume ratios, and the potential for artifacts and interference from small air-borne particles such as lint. Therefore, HTS scientists remain keenly interested in technologies that offer alternatives to the ever-shrinking microtiter plate well. Microfluidic assay technology represents an attractive option that, in theory, consumes only subnanoliter volumes of reagents per test. We have successfully employed a microfluidic assay technology in fluorogenic screening assays for several caspase isoforms utilizing the Caliper Technologies Labchip platform. Caspase-3 is used as a representative case to describe microfluidic assay development and initial high-throughput screening results. In addition, microfluidic screening and plate-based screening are compared in terms of reagent consumption, data quality, and ease of operation.  相似文献   

3.
Digital microfluidics for cell-based assays   总被引:1,自引:0,他引:1  
We introduce a new method for implementing cell-based assays. The method is based on digital microfluidics (DMF) which is used to actuate nanolitre droplets of reagents and cells on a planar array of electrodes. We demonstrate that this method is advantageous for cell-based assays because of automated manipulation of multiple reagents in addition to reduced reagent use and analysis time. No adverse effects of actuation by DMF were observed in assays for cell viability, proliferation, and biochemistry. A cytotoxicity assay using Jurkat T-cells was performed using the new method, which had approximately 20 times higher sensitivity than a conventional well plate assay. These results suggest that DMF has great potential as a simple yet versatile analytical tool for implementing cell-based assays on the microscale.  相似文献   

4.
Puleo CM  Yeh HC  Liu KJ  Wang TH 《Lab on a chip》2008,8(5):822-825
The recent proliferation of platforms designed to handle arrays of nano- and picolitre volumes is in response to the need to perform biological assays on discrete entities, such as single cells. However, a critical challenge associated with this trend for in vitro compartmentalization is the need for highly sensitive, yet low-volume detection platforms. In this paper, we coupled confocal fluorescence detection with recirculating microfluidic control to perform single particle DNA assays within five nL chambers. The performance of this low-volume assay was shown to match that of traditional single molecule detection platforms. However, volume requirements per measurement were nearly 3 orders of magnitude less than conventional systems, enabling future integration with lab-on-a-chip systems that require discrete or digitalized sample processing.  相似文献   

5.
A fluorescence detection system for a microfluidic device using an organic light-emitting diode (OLED) as the excitation light source and a charge-coupled device (CCD) as the photo detector was developed. The OLED was fabricated on a glass plate by photolithography and a vacuum deposition technique. The OLED produced a green luminescence with a peak emission at 512 nm and a half bandwidth of 55 nm. The maximum external quantum efficiency of the OLED was 7.2%. The emission intensity of the OLED at 10 mA/cm(2) was 13 μW (1.7 mW/cm(2)). The fluorescence detection system consisted of the OLED device, two band-pass filters, a five microchannel poly(dimethylsiloxane) (PDMS) microfluidic device and a linear CCD. The fluorescence detection system was successfully used in a flow-based enzyme-linked immunosorbent assay on a PDMS microfluidic device for the rapid determination of immunoglobulin A (IgA), a marker for human stress. The detection limit (S/N=3) for IgA was 16.5 ng/mL, and the sensitivity was sufficient for evaluating stress. Compared with the conventional 96-well microtiter plate assay, the analysis time and the amounts of reagent and sample solutions could all be reduced.  相似文献   

6.
Drop-based microfluidic devices for encapsulation of single cells   总被引:3,自引:0,他引:3  
We use microfluidic devices to encapsulate, incubate, and manipulate individual cells in picoliter aqueous drops in a carrier fluid at rates of up to several hundred Hz. We use a modular approach with individual devices for each function, thereby significantly increasing the robustness of our system and making it highly flexible and adaptable to a variety of cell-based assays. The small volumes of the drops enables the concentrations of secreted molecules to rapidly attain detectable levels. We show that single hybridoma cells in 33 pL drops secrete detectable concentrations of antibodies in only 6 h and remain fully viable. These devices hold the promise of developing microfluidic cell cytometers and cell sorters with much greater functionality, allowing assays to be performed on individual cells in their own microenvironment prior to analysis and sorting.  相似文献   

7.
Microfluidics technology for manipulation and analysis of biological cells   总被引:1,自引:0,他引:1  
Analysis of the profiles and dynamics of molecular components and sub-cellular structures in living cells using microfluidic devices has become a major branch of bioanalytical chemistry during the past decades. Microfluidic systems have shown unique advantages in performing analytical functions such as controlled transportation, immobilization, and manipulation of biological molecules and cells, as well as separation, mixing, and dilution of chemical reagents, which enables the analysis of intracellular parameters and detection of cell metabolites, even on a single-cell level. This article provides an in-depth review on the applications of microfluidic devices for cell-based assays in recent years (2002–2005). Various cell manipulation methods for microfluidic applications, based on magnetic, optical, mechanical, and electrical principles, are described with selected examples of microfluidic devices for cell-based analysis. Microfluidic devices for cell treatment, including cell lysis, cell culture, and cell electroporation, are surveyed and their unique features are introduced. Special attention is devoted to a number of microfluidic devices for cell-based assays, including micro cytometer, microfluidic chemical cytometry, biochemical sensing chip, and whole cell sensing chip.  相似文献   

8.
A new rapid microfluidic method for measuring enzyme inhibition is presented. The assay relies upon the creation of a uniform concentration of substrate and a microfluidically generated concentration gradient of inhibitor using a single microchannel and a single initial inhibitor concentration. The IC(50) values of two enzyme inhibitors were determined using the new technique and validated using a conventional microtiter plate assay. Using both experimental and computational simulation techniques, the assay was shown to be sensitive to inhibitor potency and the distribution of inhibitor in the system. The method has the potential to be more accurate than conventional methods because of the comparatively large amount of data that may be collected. Recommendations for use of the assay are provided, including its use for high-throughput screening in drug discovery and general use in measurement of enzyme inhibition.  相似文献   

9.
A novel surface treatment method using poly(ethyleneimine) (PEI), an amine-bearing polymer, was developed to enhance antibody binding on the poly(methyl methacrylate) (PMMA) microfluidic immunoassay device. By treating the PMMA surface of the microchannel on the microfluidic device with PEI, 10 times more active antibodies can be bound to the microchannel surface as compared to those without treatment or treated with the small amine-bearing molecule, hexamethylenediamine (HMD). Consequently, PEI surface modification greatly improved the immunoassay performance of the microfluidic device, making it more sensitive and reliable in the detection of IgG. The improvement can be attributed to the spacer effect as well as the functional amine groups provided by the polymeric PEI molecules. Due to the smaller dimensions (140x125 microm) of the microchannel, the time required for antibody diffusion and adsorption onto the microchannel surface was reduced to only several minutes, which was 10 times faster than the similar process carried out in 96-well plates. The microchip also had a wider detection dynamic range, from 5 to 1000 ng/mL, as compared to that of the microtiter plate (from 2 to 100 ng/mL). With the PEI surface modification, PMMA-based microchips can be effectively used for enzyme linked immunosorbent assays (ELISA) with a similar detection limit, but much less reagent consumption and shorter assay time as compared to the conventional 96-well plate.  相似文献   

10.
C Kim  JH Bang  YE Kim  SH Lee  JY Kang 《Lab on a chip》2012,12(20):4135-4142
This paper proposes a new cytotoxicity assay in a microfluidic device with microwells and a distributive microfluidic channel network for the formation of cancer cell spheroids. The assay can generate rapid and uniform cell clusters in microwells and test in situ cytotoxicity of anticancer drugs including sequential drug treatments, long term culture of spheroids and cell viability assays. Inlet ports are connected to the microwells by a hydraulic resistance network. This uniform distribution of cell suspensions results in regular spheroid dimensions. Injected cancer cells were trapped in microwells, and aggregated into tumor spheroids within 3 days. A cytotoxicity test of the spheroids in microwells was subsequently processed in the same device without the extraction of cells. The in situ cytotoxicity assay of tumor spheroids in microwells was comparable with the MTT assay on hanging drop spheroids using a conventional 96-well plate. It was observed that the inhibition rate of the spheroids was less than that in the 2D culture dish and the effect on tumor spheroids was different depending on the anticancer drug. This device could provide a convenient in situ assay tool to assess the cytotoxicity of anticancer drugs on tumor spheroids, offering more information than the conventional 2D culture plate.  相似文献   

11.
The design and implementation of a continuous-flow microfluidic assay for the screening of (complex) mixtures for bioactive compounds is described. The microfluidic chip featured two microreactors (1.6 and 2.4 microL) in which an enzyme inhibition and a substrate conversion reaction were performed, respectively. Enzyme inhibition was detected by continuously monitoring the products formed in the enzyme-substrate reaction by electrospray ionization mass spectrometry (ESI-MS). In order to enable the screening of mixtures of compounds, the chip-based assay was coupled on-line to capillary reversed-phase high-performance liquid chromatography (HPLC) with the HPLC column being operated either in isocratic or gradient elution mode. In order to improve the detection limits of the current method, sample preconcentration based on a micro on-line solid-phase extraction column was employed. The use of electrospray MS allowed the simultaneous detection of chemical (MS spectra) and biological parameters (enzyme inhibition) of ligands eluting from the HPLC column. The present system was optimized and validated using the protease cathepsin B as enzyme of choice. Inhibition of cathepsin B is detected by monitoring three product traces, obtained by cleavage of the substrate. The two microreactors provided 32 and 36 s reaction time, respectively, which resulted in sufficient assay dynamics to enable the screening of bioactive compounds. The total flow rate was 4 microL min-1, which a 25-fold decrease was compared with a macro-scale system described earlier. Detection limits of 0.17-2.6 micromol L-1 were obtained for the screening of inhibitors, which is comparable to either microtiter plate assays or continuous-flow assays described in the literature.  相似文献   

12.
This review covers three aspects of PCR-based microfluidic chip assays: sample preparation, target amplification, and product detection. We also discuss the challenges related to the miniaturization and integration of each assay and make a comparison between conventional and microfluidic schemes. In order to accomplish these essential assays without human intervention between individual steps, the micro-components for fluid manipulation become critical. We therefore summarize and discuss components such as microvalves (for fluid regulation), pumps (for fluid driving) and mixers (for blending fluids). By combining the above assays and microcomponents, DNA testing of multi-step bio-reactions in microfluidic chips may be achieved with minimal external control. The combination of assay schemes with the use of micro-components also leads to rapid methods for DNA testing via multi-step bioreactions. Contains 259 references. Figure
A graphical presentation of main PCR assays: DNA extraction from raw sample, target amplification by PCR and final product detection in conventional bench-top lab and miniaturized microfluidic chip.  相似文献   

13.
In the search for new therapeutic chemicals, lab-on-a-chip systems have recently emerged as innovative and efficient tools for cell-based assays and high throughput screening. Here, we describe a novel, versatile and simple device for cell-based assays at the bench-top. We created spatial variations of porosity on the surface of a membrane filter by microcontact printing with a biocompatible polymer (PDMS). We called such systems Micro-Printed Membranes (μPM). Active compounds dispensed on the porous areas, where the membrane pores are not clogged by the polymer, can cross the membrane and reach cells growing on the opposite side. Only cells immediately below those porous areas could be stimulated by chemicals. We performed proof-of-principle experiments using Hoechst nuclear staining, calcein-AM cell viability assay and destabilization of the cytoskeleton organisation by cytochalasin B. Resulting fluorescent staining properly matched the drops positioning and no cross-contaminations were observed between adjacent tests. This well-less cell-based screening system is highly flexible by design and it enables multiple compounds to be tested on the same cell tissue. Only low sample volumes in the microlitre range are required. Moreover, chemicals can be delivered sequentially and removed at any time while cells can be monitored in real time. This allows the design of complex, sequential and combinatorial drug assays. μPMs appear as ideal systems for cell-based assays. We anticipate that this lab-on-chip device will be adapted for both manual and automated high content screening experiments.  相似文献   

14.
Microfluidic adhesion-based cell separation systems are of interest in clinical and biological applications where small sample volumes must be processed efficiently and rapidly. While the ability to capture rare cells from complex suspensions such as blood using microfluidic systems has been demonstrated, few methods exist for rapid and nondestructive release of the bound cells. Such detachment is critical for applications in tissue engineering and cell-based therapeutics in contrast with diagnostics wherein immunohistochemical, proteomic, and genomic analyses can be carried out by simply lysing captured cells. This paper demonstrates how the incorporation of four-arm amine-terminated poly(ethylene glycol) (PEG) molecules along with antibodies within alginate hydrogels can enhance the ability of the hydrogels to capture endothelial progenitor cells (EPCs) from whole human blood. The hydrogel coatings are applied conformally onto pillar structures within microfluidic channels and their dissolution with a chelator allows for effective recovery of EPCs following capture.  相似文献   

15.
In this paper we report on the controlled biofunctionalization of the hydrophobic layer of electrowetting-on-dielectric (EWOD) based microfluidic chips with the aim to execute (adherent) cell-based assays. The biofunctionalization technique involves a dry lift-off method with an easy to remove Parylene-C mask and allows the creation of spatially controlled micropatches of biomolecules in the Teflon-AF(?) layer of the chip. Compared to conventional methods, this method (i) is fully biocompatible; and (ii) leaves the hydrophobicity of the chip surface unaffected by the fabrication process, which is a crucial feature for digital microfluidic chips. In addition, full control of the geometry and the dimensions of the micropatches is achieved, allowing cells to be arrayed as cell clusters or as single cells on the digital microfluidic chip surface. The dry Parylene-C lift-off technique proves to have great potential for precise biofunctionalization of digital microfluidic chips, and can enhance their use for heterogeneous bio-assays that are of interest in various biomedical applications.  相似文献   

16.
Nuclear translocation is an important step in glucocorticoid receptor (GR) signaling and assays that measure this process allow the identification of nuclear receptor ligands independent of subsequent functional effects. To facilitate the identification of GR-translocation agonists, an enzyme fragment complementation (EFC) cell-based assay was scaled to a 1536-well plate format to evaluate 9,920 compounds using a quantitative high throughput screening (qHTS) strategy where compounds are assayed at multiple concentrations. In contrast to conventional assays of nuclear translocation the qHTS assay described here was enabled on a standard luminescence microplate reader precluding the requirement for imaging methods. The assay uses beta-galactosidase alpha complementation to indirectly detect GR-translocation in CHO-K1 cells. 1536-well assay miniaturization included the elimination of a media aspiration step, and the optimized assay displayed a Z' of 0.55. qHTS yielded EC(50) values for all 9,920 compounds and allowed us to retrospectively examine the dataset as a single concentration-based screen to estimate the number of false positives and negatives at typical activity thresholds. For example, at a 9 microM screening concentration, the assay showed an accuracy that is comparable to typical cell-based assays as judged by the occurrence of false positives that we determined to be 1.3% or 0.3%, for a 3sigma or 6sigma threshold, respectively. This corresponds to a confirmation rate of approximately 30% or approximately 50%, respectively. The assay was consistent with glucocorticoid pharmacology as scaffolds with close similarity to dexamethasone were identified as active, while, for example, steroids that act as ligands to other nuclear receptors such as the estrogen receptor were found to be inactive.  相似文献   

17.
《Analytical letters》2012,45(7):1461-1476
Abstract

A recently developed shallow-well microtiter plate, made from a specially formulated polymer that binds proteins, peptides and nucleic acids rapidly and efficiently, has been investigated for use in solid-phase immunoassays as well as for protein and phospholipid assays. The assay uses quantitation of the color intensity of a dye on the solid phase by means of a simple desk-top scanner coupled to a computer which allows the gray-scale density of the color to be easily and accurately measured. Consequently, this approach is independent of the absorption spectrum of the dye used.

These studies demonstrate that the novel technology incorporated into these unique shallow-well microtiter plates has potential in both protein and immunoassays. In the latter case, there are considerable savings in both time and material costs over conventional ELISA methods. The scanning software provided for the solid-phase immunoassay is user configurable for other densitometry assays on different solid matrices and can be read directly into a spreadsheet file for subsequent data manipulation.  相似文献   

18.
Fluorescence and electrochemical microfluidic biosensors were developed for the detection of cholera toxin subunit B (CTB) as a model analyte. The microfluidic devices were made from polydimethylsiloxane (PDMS) using soft lithography from silicon templates. The polymer channels were sealed with a glass plate and packaged in a polymethylmethacrylate housing that provided leakproof sealing and a connection to a syringe pump. In the electrochemical format, an interdigitated ultramicroelectrode array (IDUA) was patterned onto the glass slide using photolithography, gold evaporation and lift-off processes. For CTB recognition, CTB-specific antibodies were immobilized onto superparamagnetic beads and ganglioside GM1 was incorporated into liposomes. The fluorescence dye sulforhodamine B (SRB) and the electroactive compounds potassium hexacyanoferrate (II)/hexacyanoferrate (III) were used as detection markers that were encapsulated inside the liposomes for the fluorescence and electrochemical detection formats, respectively. Initial optimization experiments were carried out by applying the superparamagnetic beads in microtiter plate assays and SRB liposomes before they were transferred to the microfluidic systems. The limits of detection (LoD) of both assay formats for CTB were found to be 6.6 and 1.0 ng mL−1 for the fluorescence and electrochemical formats, respectively. Changing the detection system was very easy, requiring only the synthesis of different marker-encapsulating liposomes, as well as the exchange of the detection unit. It was found that, in addition to a lower LoD, the electrochemical format assay showed advantages over the fluorescence format in terms of flexibility and reliability of signal recording.  相似文献   

19.
Li CW  Yang J  Yang M 《Lab on a chip》2006,6(7):921-929
The capability of lab-on-a-chip technologies in controlling cell transportation, generating concentration gradients, and monitoring cellular responses offers an opportunity to integrate dose-dependent cell-based bioassays on a chip. In this study, we have developed microfluidic modules featured with channel components and sandbag structures for positioning biological cells within the microchip. We have demonstrated that by geometric modulation of the microchannel architectures, it is possible to immobilize individual cells at desired locations with controllable numbers, to generate defined concentration gradients at various channel lengths, and to improve the efficiency and reproducibility in data acquisition. The microfluidic module was used to exercise a series of cell-based assays, including the measurement of kinetics and dynamics of intracellular enzymatic activities, the analysis of cellular response under the stimulation of two chemicals with defined concentration profiles, and the study of laser irradiation effect on cellular uptake of photosensitizers. The results demonstrated the capabilities of the microfluidic module for simultaneously conducting multiple sets of dose-dependent, cell-based bioassays, and for quantitatively comparing responses of individual cells under various stimulations.  相似文献   

20.
High-density microfluidic arrays for cell cytotoxicity analysis   总被引:12,自引:0,他引:12  
In this paper, we report on the development of a multilayer elastomeric microfluidic array platform for the high-throughput cell cytotoxicity screening of mammalian cell lines. Microfluidic channels in the platform for cell seeding are orthogonal to channels for toxin exposure, and within each channel intersection is a circular chamber with cell-trapping sieves. Integrated, pneumatically-actuated elastomeric valves within the device isolate the microchannel array within the device into parallel rows and columns for cell seeding and toxin exposure. As a demonstration of the multiplexing capability of the platform, a microfluidic array containing 576 chambers was used to screen three cell types (BALB/3T3, HeLa, and bovine endothelial cells) against a panel of five toxins (digitonin, saponin, CoCl(2), NiCl(2), acrolein). Evaluation of on-chip cell morphology and viability was carried out using fluorescence microscopy, with outcomes comparable to microtiter plate cytotoxicity assays. Using this scalable platform, cell seeding and toxin exposure can be carried out within a single microfluidic device in a multiplexed format, enabling high-density parallel cytotoxicity screening while minimizing reagent consumption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号