首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

2.
Optimisation of peak capacity is an important strategy in gradient liquid chromatography (LC). This can be achieved by using either long columns or columns packed with small particles. Monolithic columns allow the use of long columns at relatively low back-pressure. The gain in peak capacity using long columns was evaluated by the separation of a tryptic bovine serum albumin digest with an LC–UV–mass spectrometry (MS) system and monolithic columns of different length (150 and 750 mm). Peak capacities were determined from UV chromatograms and MS/MS data were used for Mascot database searching. Analyses with a similar gradient slope for the two columns produced ratios of the peak capacities that were close to the expected value of the square root of the column length ratio. Peak capacities of the short column were 12.6 and 25.0 with 3 and 15 min gradients, respectively, and 29.7 and 41.0 for the long column with 15 and 75 min gradients, respectively. Protein identification scores were also higher for the long column, 641 and 750 for the 3- and 15-min gradients with the short column and 1,376 and 993 for the 15- and 75-min gradients with the long column. Thus, the use of long monolithic columns provides improved peptide separation and increased reliability of protein identification.  相似文献   

3.
A technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C18 and monolithic columns were in the range of 88-111% and 0.5-14%, respectively. Total analysis cycle time of 4 min per sample was demonstrated using the C18 column. Monolithic column allowed for 2 min total cycle time without compromising the quality and validation criteria of the method. Direct plasma sample injection without on-line SPE resulted in poor accuracy and precision in the range of 41-108% and 3-81%. Furthermore, the increase in back pressure resulted in column damage after the injection of only 60 samples.  相似文献   

4.
We report a cyclic sample pooling technique devised in two‐dimensional liquid chromatography–electrospray ionization mass spectrometry (LC‐ESI‐MS) shotgun proteomics that renders deeper proteome coverage; we combined low pH reversed‐phase (RP) LC in trifluoroacetic acid in the first dimension, followed by cyclic sample pooling of the eluate and low‐pH RP‐LC in formic acid in the second dimension. The new protocol has a significantly higher resolving power suitable for LC‐ESI‐MS/MS shotgun proteomics. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
The enormous interest in proteomics research in recent years has inspired many developments in peptide chromatography. Different strategies have been developed to cope with the vast complexity of proteomics samples, trying to provide sufficient degree of separation to be able to exploit fully the potential of protein identification by mass spectrometry (MS). As reversed-phase liquid chromatography (RPLC) coupled to MS is still the method of choice for the analysis of protein digests, many efforts focus on the development of high-efficiency RP methods (e.g., monolithic columns and ultra-high-performance LC). This can also increase the speed and the sensitivity of the analysis of protein digests.As RPLC-MS alone is unlikely to provide sufficient resolution to unravel the composition of highly complex samples comprehensively, multidimensional methods will remain essential in proteome research. In this area, hydrophilic interaction chromatography (HILIC) seems to be a promising alternative to the traditional strong cation-exchange-based methods. Also, HILIC has found application in the analysis of post-translational modifications (e.g., phosphorylation and glycosylation).This review describes recent developments in LC methods for proteomics research, focusing on advances in column technology and the application of novel column materials. Illustrative examples show the possibilities of the new columns in proteomics research.  相似文献   

6.
A comprehensive 2-D LC x LC system was developed for the separation of phenolic and flavone antioxidants, using a PEG-silica column in the first dimension and a C(18) column with porous-shell particles or a monolithic column in the second dimension. Combination of PEG and C18 or C8 stationary phase chemistries provide low selectivity correlations between the first dimension and the second dimension separation systems. This was evidenced by large differences in structural contributions to the retention by -COOH, -OH and other substituents on the basic phenol or flavone structure. Superficially porous columns with fused core particles or monolithic columns improve the resolution and speed of second dimension separation in comparison to a fully porous particle C(18) column. Increased peak capacity and high orthogonality in different 2-D setups was achieved by using gradients with matching profiles running in parallel in the two dimensions over the whole 2-D separation time range. Multi-dimensional set-up combining the LC x LC separation on-line with UV and multi-channel coulometric detection and off-line with MS/MS technique allowed positive peak identification. The Coularray software compensates for the effects of the baseline drift during the gradient elution and is compatible with parallel gradient comprehensive LC x LC technique. Furthermore, it provides significant improvement in the sensitivity and selectivity of detection in comparison to both UV and MS detection. The utility of these systems has been demonstrated in the analysis of beer samples.  相似文献   

7.
A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, which combines on-line sample extraction through turbulent flow chromatography with a monolithic column separation, has been developed for direct injection analysis of drugs and metabolites in human plasma samples. By coupling a monolithic column into the system as the analytical column, the method enables running 'dual-column' extraction and chromatography at higher flow rates, thus significantly reducing the time required for the transfer and mixing of extracted fraction onto the separation column as well as the time for gradient separation. A strategy of assessing and reducing the matrix suppression effect on the on-line extraction LC/MS/MS has also been discussed. Experiments for evaluating the resolution, peak shape, sensitivity, speed, and matrix effect were conducted with dextromethorphan and its metabolite dextrorphan as model compounds in human plasma matrix. It was demonstrated that the total run time for this assay with a baseline separation of two analytes is less than 1.5 min.  相似文献   

8.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

9.
The gain in separation efficiency for protein digests using long monolithic columns has been evaluated for a LC‐MS system with capillary monolithic columns of different lengths (150 and 750 mm). A mixture of BSA, α‐casein and β‐casein tryptic digests was used as a test sample. Peak capacity and productivity (peak capacity per unit time) were determined from base peak chromatograms and MS/MS data were used for protein identification by MASCOT database searching. Peak capacity and protein identification scores were higher for the long column. Analyses with similar gradient slope for the two columns produced ratios of the peak capacities that were slightly higher than the expected value of the square root of the column length ratio. Peak capacity ratios varied from 2.7 to 4.0 for four different gradient slopes, while protein identification scores were 2–4 times higher for the long column. Similar values were obtained for the productivity of both columns and the highest productivity was obtained at gradient times of 45 and 75 min for the short and long column, respectively. The use of long monolithic columns improves peptide separation and increases reliability of protein identification for complex digests, especially if longer gradients are chosen.  相似文献   

10.
Hyung SW  Kim MS  Mun DG  Lee H  Lee SW 《The Analyst》2011,136(10):2100-2105
The microcapillary liquid chromatography (μLC)/tandem mass spectrometry (MS/MS) system has become a prevailing analytical platform in proteomics. Typical proteomic studies aimed at proteome-wide identification of peptides and proteins rely heavily on producing an accurate and reproducible solvent-composition gradient throughout microcapillary separation columns to improve LC separation. With the recent advent of targeted proteomic approaches utilizing the LC retention time as a physicochemical parameter for peptides, high reproducibility of LC separation additionally becomes an important factor. In this study, column temperature elevation is utilized to improve reproducibility and separation efficiency of the μLC-MS/MS system. The simple incorporation of a semi-rigid gas line heater allowed precise control of the temperature of microcapillary columns longer than 70 cm, up to 60 °C. Tryptic enolase peptides were used as a standard sample to evaluate the effect of the controlled temperature elevation on the peptide separation efficiency and reproducibility. In addition to the increased reproducibility in peptide elution time due to the controlled column temperature, the temperature elevation resulted in a decrease in the column operation pressure, which, in turn, allowed a higher solvent flow-rate to be employed using the same LC pumps, leading to further improvements in the performance of μLC systems.  相似文献   

11.
With the ever-increasing workload from a variety of in vitro and in vivo screening procedures, new analytical methodologies to perform bioanalysis in an accurate and high-throughput manner are in great demand. In this work, monolithic columns were used instead of conventional particulate HPLC columns to perform chromatographic separations. Because the pressure drop on a monolithic column was considerably lower than that on a particulate column, a high flow rate (6 mL/min) was used for a 4.6 x 50 mm monolithic column with a total backpressure of about 61 bar measured using acetonitrile/water (50:50). The capability of using a regular column length at high flow rates, combined with the extremely small dependency of separation efficiency on linear flow velocity, allowed for the generation of sufficient chromatographic resolving power in a significantly reduced runtime. As demonstrated in this work, a plasma extract of a mixture of tempazepam, tamoxifen, fenfluramine, and alprozolam were baseline separated within a total analysis time of one minute. An average peak width at half maximum of approximately one second was noted using a generic broad gradient. It was also found that the separation efficiency and signal/noise (S/N) ratios for this separation remained almost constant at flow rates of 1, 3, and 6 mL/min, respectively. The ruggedness of the separation was evaluated by injecting 600 plasma extracts containing the replicates of a standard curve of the above mixture during an overnight run. The chromatographic retention time, separation quality, peak response and sensitivity were highly reproducible throughout the run. This high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) system has been used routinely in the authors' laboratory to support drug discovery programs.  相似文献   

12.
This study records a novel application of methacrylate-based monolithic columns for MALDI-TOF/TOF MS analyses in proteomics for pre-concentration and separation of peptides derived from protein digestion. Reversed-phase monolithic capillary columns (30 mm × 0.32 mm i.d.) were created inside the fused silica capillary via thermal-initiated free-radical polymerization of ethylene glycol dimethacrylate and lauryl methacrylate monomers in the presence of 1-propanol and 1,4-butandiol as a porogen system. The elution of peptides was achieved using a linear gradient of acetonitrile from 0 to 60% in water with 0.1% trifluoroacetic acid formed in a microsyringe. Individual fractions of separated peptides were collected on the MALDI target spots covered with alpha-cyano-4-hydroxycinnamic acid used as a matrix and then they were analyzed using MALDI-TOF/TOF mass spectrometry. The developed method was tested with a mixture of tryptic peptides from bovine serum albumin and its applicability was also tested for tryptic in-gel digests from barley grain extracts of water soluble proteins separated using SDS gel electrophoresis. The number of detected peptides was approximately three to four times higher compared to the analysis without previous separation. These results show an improved quality of sample information with the higher amount of identified peptides which increased protein sequence coverage and improved sensitivity of mass spectrometry measurements.  相似文献   

13.
In this study, the performance of monolithic columns was evaluated for ultrafast liquid chromatography/mass spectrometry (LC/MS) analyses and for high-resolution separations of several azaspiracid biotoxin analogs. Because of their high permeability, monolithic columns offer a number of advantages over conventional packed columns; viz., very low backpressures and relatively flat van Deemter curves at high flow rates. That is, very high flow rates can be used for ultrafast analyses or, by using longer than normal columns, high-resolution separations are possible. In a series of experiments, we varied the mobile phase flow rates between 1 and 8 mL/min, and studied their impact on chromatographic parameters such as retention time, resolution, number of plates and pressure. The chromatographic run times could be reduced to ca. 30 s without a significant change in the separation efficiency. A signal intensity comparison revealed interesting differences between atmospheric-pressure chemical ionization (APCI) and electrospray ionization (ESI) in their flow-rate dependency. An explanation with respect to the behavior as of a mass-flow or a concentration-dependent device is given in the paper. Additionally, the column length was varied between 10 and 70 cm. As a result, the number of theoretical plates increased substantially. In the example shown in the report, an increase from 13 000 plates for a 10-cm column to 80 000 for a 70-cm column is demonstrated. In addition, the potential of the monolithic columns for high-resolution LC/MS separations is shown for a complex biotoxin mixture, which was separated on a 40-cm-long column.  相似文献   

14.
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Both the mesopore and macropore diameters of the monolithic column are decisive for the column efficiency. As the diameter of the through-pores decreases, the column efficiency increases. The large set of mesopores studied with a nominal diameter of approximately 25 nm provided the most efficient column performance. The efficiency of the monolithic silica columns increase with decreasing n-alkyl chain length in the sequence of C18相似文献   

15.
There is an increasing need to be able to conduct quantitative lipidomics analyses as a complement to proteomics studies. The highest specificity for proteomics analysis can be obtained using methodology based on electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS). For lipidomics analysis it is often necessary to be able to separate enantiomers and regioisomers. This can be very challenging when using methodology based on conventional reversed-phase chromatography. Normal-phase chromatography using chiral columns can provide dramatic improvements in the resolution of enantiomers and regioisomers. However, conventional ESI- and APCI-MS/MS has limited sensitivity, which makes it difficult to conduct studies in cell culture systems where only trace amounts of non-esterified bioactive lipids are present. The use of electron capture APCI-MS/MS overcomes this problem. Enantiomers and regioisomers of diverse bioactive lipids can be quantified using stable isotope dilution methodology coupled with normal-phase chiral chromatography and electron capture APCI-MS/MS. This methodology has allowed a lipidomics profile from rat epithelial cells maintained in culture to be delineated and allowed the effect of a non-selective lipoxygenase inhibitor to be assessed.  相似文献   

16.
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods developed for quantification using rapid ('ballistic') gradients on narrow bore, short HPLC columns have been previously described by this laboratory. This paper compares the fast gradient approach with the more traditional high-organic isocratic LC/MS/MS methods. The comparison is based on an analysis of the effectiveness of the chromatographic separations when using the two approaches (i.e. k', N, and W). The data presented herein are derived from actual biological samples analyzed as part of the drug discovery process.  相似文献   

17.
On examining different proteomics approaches for the investigation of structure-function relationships of erythropoietin (EPO) receptor signaling, it was found that two-dimensional gel electrophoresis/mass spectrometry procedures are clearly limited in their ability to detect low-expressed signaling proteins. Instead it was found that a strategy involving anti-phosphotyrosine immunoprecipitation, one-dimensional gel electrophoresis (1DE), and capillary liquid chromatography/tandem mass spectrometry (LC/MS/MS) provides the sensitivity required for identification of signaling proteins. In the present work the immunoprecipitation/1DE/LC/MS approach was combined with an in-gel 18O-labeling technique to analyze EPO receptor-dependent proteins. Identification and relative quantification of more than 180 EPO receptor-dependent proteins were achieved directly based on the in-gel 18O-labeling approach.  相似文献   

18.
Jiang X  Dong J  Wang F  Feng S  Ye M  Zou H 《Electrophoresis》2008,29(8):1612-1618
An automated nano-LC-MS/MS platform without trap column was established, which only used a 20 cm lauryl methacrylate-ethylene dimethacrylate (LMA-EDMA) monolithic capillary column to allow preconcentration and separation of peptides. The monolithic column had the advantages of good permeability and low backpressure resulting in higher flow rates for capillary columns. Tryptic digests of bovine albumin and yeast protein extract were tested using the monolithic column system. High proteomic coverage using this approach were demonstrated in this study. Furthermore, peptide samples extracted from mouse liver were separated by using the monolithic column system combined with size-exclusion chromatography prefractionation. This monolithic column system might be a promising alternative for the automated system previously using a trap column for routine proteome and peptide profiling analysis.  相似文献   

19.
In this work, a high-throughput and high-performance bioanalytical system is described that is capable of extracting and analyzing 1152 plasma samples within 10 hours. A Zymark track robot system interfaced with a Tecan Genesis liquid handler was used for simultaneous solid-phase extraction of four 96-well plates in a fully automated fashion. The extracted plasma samples were injected onto four parallel monolithic columns for separation via a four-injector autosampler. The use of monolithic columns allowed for fast and well-resolved separations at a considerably higher flow rate without generating significant column backpressure. This resulted in a total chromatographic run cycle time of 2 min on each 4.6 x 100 mm column using gradient elution. The effluent from the four columns was directed to a triple quadrupole mass spectrometer equipped with an indexed four-probe electrospray ionization source (Micromass MUX interface). Hence, sample extraction, separation, and detection were all performed in a four-channel parallel format that resulted in an overall throughput of about 30 s per sample from plasma. The performance of this system was evaluated by extracting and by analyzing twelve 96-well plates (1152) of human plasma samples spiked with oxazepam at different concentrations. The relative standard deviation (RSD) of analyte sensitivity (slope of calibration curve) across the four channels and across the 12 plates was 5.2 and 6.8%, respectively. An average extraction recovery of 77.6% with a RSD of 7.7% and an average matrix effect of 0.95 with a RSD of 5.2% were achieved using these generic extraction and separation conditions. The good separation efficiency provided by this system allowed for rapid method development of an assay quantifying the drug candidate and its close structural analog metabolite. The method was cross-validated with a conventional liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay.  相似文献   

20.
Three long and 1 short reversed-phase C18 columns were compared for separation of deoxynivalenol (DON) in extracts of naturally contaminated wheat samples using liquid chromatography with ultraviolet detection and liquid chromatography/mass spectrometry (LC/MS). Among the 3 long columns used, a Symmetry C18 column with an isocratic solvent mixture of water-acetonitrile-methanol (90 + 5 + 5, v/v/v) gave the best separation for DON without interferences from other compounds in the wheat extracts. The Symmetry short (75 mm) column was comparable with the long column (250 mm) in resolving DON but significantly reduced retention time (i.e., 5.8 versus 16.3 min). Increasing the column temperature from 25 to 45 degrees C resulted in a further reduction in retention time. Identity of DON in the wheat extracts and standard solutions was confirmed by LC/MS in the positive ion mode, whereby DON appeared with an (M+1)+ ion at a mass-to-charge ratio of 297 plus fragment ions associated with loss of water and/or a 30 atomic mass unit (amu) CH2O fragment. The Symmetry short column was also capable of separating a mixture of the mycotoxins DON, 15-acetyl-DON, nivalenol, and zearalenone by use of a combination of an isocratic and gradient solvent system. The overall method showed high precision, exhibiting a relative standard deviation of 4.8%, limit of detection of 50 ng/g, and limit of quantitation of 165 ng/g. It was significantly correlated with enzyme-linked immunosorbent assay analysis, indicating its appropriateness for safety and quality assurance of wheat and related grains.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号