首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   

2.
Tryptic digests were analyzed by means of online microbore liquid chromatography combined with mass spectrometry (LC/MS) for some common proteins. Following conventional enzymatic digestion with trypsin, the freeze-dried residues were dissolved in high-performance liquid chromatography (HPLC) eluent and subjected to gradient reversed-phase microbore HPLC separation with mass spectrometric detection. The latter was done in the full-scan single or tandem (MS/MS) mass spectrometry mode. The formation of gas-phase ions from dissolved analytes was accomplished at atmospheric pressure by pneumatically assisted electrospray (ion spray) ionization. This produced field-assisted ion evaporation of dissolved ions, which could then be mass-analyzed for molecular mass or structure. In the full-scan LC/MS mode, the masses for the peptide fragments in the tryptic digests can be determined as either their singly or multiply charged ions. When the molecular weights of the peptides lie outside the mass range of the mass spectrometer, the multiply charged feature of these experimental conditions still provides reliable molecular weight determinations. In addition, collision-activated dissociation (CAD) on selected peptide precursor ions provides online LC/MS/MS sequence information for the tryptic fragments. Results are shown for the tryptic digests of horse heart cytochrome c, bovine β-lactoglobulin A, and bovine β-lactoglobulin B.  相似文献   

3.
This work describes the analysis of a pyrolysis product of a lignite sample obtained from the Turkish Goynuk reserve. The aliphatic, aromatic and polar compounds present in the tar are separated and identified by various chromatographic techniques: Capillary gas chromatography/mass spectrometry (GC/MS), on-line high performance microbore liquid chromatography/capillary gas chromatography (LC/GC) and capillary supercritical fluid chromatography (SFC). The suitability of each technique for this particular application is discussed, and semi-quantitative results are presented for the major components detected.  相似文献   

4.
A frit restrictor interface for capillary column supercritical fluid chromatography/mass spectrometry (SFC/MS) has been constructed and used for the analysis of high boiling point alkanes. Packed column SFC/MS is described using both a moving belt liquid chromatographic/mass spectrometric interface and a thermospray source in the filament-on mode.  相似文献   

5.
Identification of dyes in historic textiles was until recently only based on reversed phase liquid chromatography and diode-array detection (RPLC–DAD). Although in the last years mass spectrometry (MS) is increasingly used as a detection system for liquid chromatography, most applications in the field are directed to identification of the molecular ions or in studies dedicated to degradation products which may be used as markers in RPLC–DAD. In the present work, an analytical protocol for the identification of dyes using RPLC/ESI/MS is presented. Atmospheric pressure electrospray ionization (ESI) was applied, in the negative ion monitoring mode. Both single stage and tandem MS (MS/MS) approaches were considered. An ion trap was used as mass analyzer. Experiments are based on the characterization of standards (natural dyes and/or dyed fibers) with the mass spectrometer sequentially working in the following modes: single MS/full scan, followed by plotting chromatograms through ion extraction (IEC) according to mass/charge ratios corresponding to molecular ions; single MS/selected ion monitoring (SIM) mode; tandem MS/single reaction monitoring (SRM) mode; tandem MS/multiple reactions monitoring (MRM) or product ion scanning modes. A faster chromatographic separation could be applied as MS detection readily balanced the selectivity of the analytical process. In a case study, 11 dyes from 3 biological sources were detected in a 0.5 mg historic sample.  相似文献   

6.
The goal of this work was to evaluate the improvement in proteome coverage of complex protein mixtures gained by analyzing samples using both LC/ESI/MS/MS and LC/MALDI/MS/MS. Parallel analyses of a single sample were accomplished by interfacing a Probot fractionation system with a nanoscale LC system. The Probot was configured to perform a post-column split such that a fraction (20%) of the column effluent was sent for on-line LC/ESI/MS/MS data acquisition, and the majority of the sample (80%) was mixed with a matrix solution and deposited onto the MALDI target plate. The split-flow approach takes advantage of the concentration sensitive nature of ESI and provides sufficient quantity of sample for MALDI/MS/MS. Hybrid quadrupole time-of-flight mass spectrometers were used to acquire LC/ESI/MS/MS data and LC/MALDI/MS/MS data from a tryptic digest of a preparation of mammalian mitochondrial ribosomes. The mass spectrometers were configured to operate in a data dependent acquisition mode in which precursor ions observed in MS survey scans are automatically selected for interrogation by MS/MS. This type of acquisition scheme maximizes the number of peptide fragmentation spectra obtained and is commonly referred to as shotgun analysis. While a significant degree of overlap (63%) was observed between the proteins identified in the LC/ESI/MS/MS and LC/MALDI/MS/MS data sets, both unique peptides and unique proteins were observed by each method. These results demonstrate that improved proteome coverage can be obtained using a combination of these ionization techniques.  相似文献   

7.
A diverse set of 16 high-throughput organic synthesis libraries, consisting of 48 samples per library, has been purified by both preparative supercritical fluid chromatography (SFC) and preparative high-performance liquid chromatography (HPLC). This paper details the relative effectiveness of these two purification techniques in terms of success, yield, and purity of final product.  相似文献   

8.
High-throughput quantitative bioanalysis by LC/MS/MS   总被引:8,自引:0,他引:8  
This review article discusses the most recent significant advances in the sample preparation and mass spectrometry aspects of high-throughput bioanalysis by LC/MS/MS for the quantitation of drugs, metabolites and endogenous biomolecules in biological matrices. The introduction and implementation of automated 96-well extraction has brought about high-throughput approaches to the biological sample preparation techniques of solid-phase extraction, liquid-liquid extraction and protein precipitation. The fast-flow on-line extraction technique is a different high-throughput approach that has also significantly speeded up analysis by LC/MS/MS. The use of pierceable caps for biological tubes further enhances the analysis speed and improves the safety in handling biological samples. The need for adequate chromatographic separation in order to eliminate interferences due to metabolites and/or matrix effects in LC/MS/MS is discussed. To highlight our limited understanding of atmospheric pressure ionization mass spectrometry, results from recent investigations that appear to be counter-intuitive are presented. Looking ahead to the future, multiplexed LC/MS/MS systems and capillary LC are presented as areas that can bring about further improvements in analysis speed and sensitivity to quantitative bioanalysis by LC/MS/MS.  相似文献   

9.
A simple ion trap/ion mobility/time-of-flight (TOF) mass spectrometer has been coupled with nanoflow liquid chromatography to examine the feasibility of analyzing mixtures of intact proteins. In this approach proteins are separated using reversed-phase chromatography. As components elute from the column, they are electrosprayed into the gas phase and separated again in a drift tube prior to being dispersed and analyzed in a TOF mass spectrometer. The mobilities of ions through a buffer gas depend upon their collision cross sections and charge states; separation based on these gas-phase parameters provides a new means of simplifying mass spectra and characterizing mixtures. Additionally it is possible to induce dissociation at the exit of the drift tube and examine the fragmentation patterns of specific protein ion charge states and conformations. The approach is demonstrated by examining a simple three-component mixture containing ubiquitin, cytochrome c, and myoglobin and several larger prepared protein mixtures. The potential of this approach for use in proteomic applications is considered.  相似文献   

10.
LC/MS/MS方法筛查新生儿苯丙酮尿症   总被引:5,自引:1,他引:5  
苯丙酮尿症 [1~ 4 ] ( PKU )发病原因是患者基因缺陷使肝脏不能合成苯丙氨酸羟化酶而导致体内苯丙氨酸 ( Phe)不能正常代谢为酪氨酸 ( Tyr) ,前者在体内大量堆积并氧化为对人体有害的苯丙酮酸 . PKU是目前筛查范围最广的氨基酸代谢遗传疾病 ,在全世界每年 [5]约有一千万婴儿接受 PKU筛查 ;在我国 ,PKU也是卫生部要求重点筛查的病种 .Chace[5]等在 1 993年报道了 MS/ MS方法筛查新生儿PKU:直接使用 MS/ MS的中性碎片丢失扫描方式检测 Phe和 Tyr,通过氘代内标与待测氨基酸的质谱峰高比来定量 .MS/ MS方法速度快、准确性好、可以…  相似文献   

11.
A liquid chromatography-tandem mass spectrometry method was developed for the determination of ketamine (with its metabolite norketamine) and some amphetamines (amphetamine, methamphetamine, methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine). This method was developed to determine these compounds in hair and is able to simultaneously quantify all of them in human hair. Hair samples (20 mg) were washed and pulverized, and an extraction with formic acid (0.01%) and ultrasonication for 4 h was used. Deuterated analogs of the analytes were used as internal standards for quantification. Linearity from 0.5 to 25 ng/mg was obtained for both ketamine (and norketamine) and amphetamines with correlation coefficients exceeding 0.99. The limit of detection and the limit of quantification obtained were 0.1 and 0.5 ng/mg, respectively, for ketamine and amphetamines. A total of 25 hair samples from known drug abusers (relating to designer drug consumption or consumption of amphetamines) were examined by this validated method. The results show that the proposed method is suitable for testing these drugs in a single sample of hair. In addition, it is simpler and faster than analysis by conventional methods such as gas chromatography-mass spectrometry, which usually require a more laborious extraction procedure and, in most of cases, an additional derivatization process.  相似文献   

12.
A rapid, sensitive, and reliable liquid chromatography-tandem mass spectrometric method was developed to quantify ipatasertib in dog plasma. The dog plasma sample was deproteinated by using acetonitrile with ulixertinib as an internal standard followed by separation on a Spursil C18-EP column with a gradient mobile phase comprising 2 mM ammonium acetate containing 0.1% formic acid and acetonitrile. Positive ion electrospray was used, and multiple reaction monitoring transitions were m/z 458.2 > 387.2 for ipatasertib and m/z 433.1 > 262.1 for the internal standard. The developed method was validated with a linear range of 0.3–1500 ng/mL, and with correlation coefficient greater than 0.9989. The lower limit of quantification was 0.3 ng/mL. The intra- and inter-day precision ranged from 3.58 to 14.32%, whereas the intra- and inter-day accuracy was in the range of −2.50–13.25%. No carry-over and matrix effects were observed under the current conditions. The extraction recovery was demonstrated to be greater than 85.43%. Ipatasertib was stable during the storage, processing, and determination. The validated assay was further successfully applied to a pharmacokinetic study of ipatasertib in dogs after oral and intravenous administrations. The bioavailability of ipatasertib was determined to be 19.3%.  相似文献   

13.
The potential application of capillary column supercritical fluid chromatography (SFC) and SFC/mass spectrometry (SFC/MS) for the separation and analysis of mycotoxins of the trichothecene group was examined. Trichothecenes present significant analytical problems for both gas and liquid chromatography with a major difficulty for the latter being the lack of sufficiently sensitive and selective detectors. Supercritical carbon dioxide mobile phases at temperatures up to 100 degrees C were used with deactivated fused silica columns coated with crosslinked stationary phases. Separations were obtained under pressure ramped conditions using long (15 m) 50-micron i.d. columns for several trichothecenes (diacetoxyscirpenol, deoxynivalenol, and T-2 toxin) and related higher molecular weight macrocyclic (roridin and verrucarin) trichothecenes. In addition, new rapid pressure programming techniques with short (less than 2m) 25- to 50-micron i.d. capillary columns were used to obtain fast separations in as little as 1 min. SFC/MS with ammonia chemical ionization provided high selectivity and sensitive detection (with approximately 1-pg detection limits) for trichothecene mixtures. The extension to complex sample matrices is discussed and the application of selective MS/MS detection is demonstrated.  相似文献   

14.
In this paper, we discuss various methods for fraction collection in high-throughput chromatography. UV-triggered fractionation allows precise cutting of peaks. However, valuable fraction collector space is wasted, because many undesired compounds are collected. In mass-triggered fraction collection, the collector space is used more efficiently, because only peaks containing the desired products are collected. Unfortunately, mass peaks are broader than UV peaks, and therefore, fractions contaminated by a closely following peak are often collected. This can be avoided if the collection in preparative LC/MS occurs by a logical AND combination of UV- and mass-triggered collection. The success of this optimal collection mode is shown for three examples.  相似文献   

15.
The in vivo and in vitro metabolism of jatrorrhizine has been investigated using a specific and sensitive LC/MS/MS method. In vivo samples including rat feces, urine and plasma collected separately after dosing healthy rats with jatrorrhizine (34 mg/kg) orally, along with in vitro samples prepared by incubating jatrorrhizine with rat intestinal flora and liver microsome, respectively, were purified using a C(18) solid-phase extraction cartridge. The purified samples were then separated with a reversed-phase C(18) column with methanol-formic acid aqueous solution (70:30, v/v, pH3.5) as mobile phase and detected by on-line MS/MS. The structural elucidation of the metabolites was performed by comparing their molecular weights and product ions with those of the parent drug. As a result, seven new metabolites were found in rat urine, 13 metabolites were detected in rat feces, 11 metabolites were detected in rat plasma, 17 metabolites were identified in intestinal flora incubation solution and nine metabolites were detected in liver microsome incubation solution. The main biotransformation reactions of jatrorrhizine were the hydroxylation reaction, the methylation reaction, the demethylation reaction and the dehydrogenation reaction of parent drug and its relative metabolites. All the results were reported for the first time, except for some of the metabolites in rat urine.  相似文献   

16.
A single-laboratory validation is reported for an LC/MS/MS quantification of six brevetoxins in four matrixes (Greenshell mussel, eastern oyster, hard clam, and Pacific oyster). Recovery and precision data were collected from seven analytical batches using shellfish flesh at 0.05 mg/kg. Method recoveries and within-laboratory reproducibility ranged from 73 to 112%, with an RSD between 14 and 18% for brevetoxin-3, brevetoxin B5, brevetoxin B2, and S-desoxy brevetoxin B2. The recovery and within-laboratory reproducibility for brevetoxin-2 was 61%, with an RSD of 27%. Brevetoxin B1 gave an RSD of 12%, but no reference material was available and this toxin was only recorded in a hard clam sample naturally contaminated with brevetoxins. One naturally contaminated sample of each shellfish matrix, with brevetoxin levels ranging from 0.012 to 9.9 mg/kg, was tested in multiple batches, and the RSDs were similar to those for fortified samples at 0.05 mg/kg. Comparisons with limited data for the neurotoxic shellfish poisoning mouse bioassay for four naturally contaminated shellfish samples showed that the regulatory action limit of 0.8 mg/kg is conservative with respect to the bioassay regulatory limit of 20 mouse units/100 g.  相似文献   

17.
Here, we describe a system for LC/MS-based analysis and purification of compounds aiming at the minimization of manual interference in the overall process. Key elements of the concept are automated identification of the target compounds, automated assignment of optimized preparative gradients for purification of the target compounds, and automated purity assessment of fractions with subsequent pooling of validated product fractions. Additional support is provided by an automated solvent and waste management system. One person can easily process 100-200 compounds on a 150-mg scale per day on that system, while still the maximization of purity and yield after purification is guaranteed. Reduced demands with respect to purity or yield can lead to significantly higher throughput numbers.  相似文献   

18.
Pharmaceuticals have become major targets in environmental chemistry due to their presence in aquatic environments (following incomplete removal in wastewater treatment or point-source contaminations), threat to drinking water sources and concern about their possible effects to wildlife and humans. Recently several methods have been developed for the determination of drugs and their metabolites in the lower nanogram per litre range, most of them using solid-phase extraction (SPE) or solid-phase microextraction (SPME), derivatisation and finally gas chromatography mass spectrometry (GC-MS), gas chromatography tandem mass spectrometry (GC-MS/MS) and liquid chromatography electrospray tandem mass spectrometry (LC-ES/MS/MS). Due to the elevated polarity of non-steroidal anti-inflamatory drugs (NSAIDs), analytical techniques based on either liquid chromatography coupled to mass spectrometry (LC-MS) and gas chromatography coupled to mass spectrometry (GC-MS) after a previous derivatisation step are essential. The most advanced aspects of current GC-MS, GC-MS/MS and LC-MS/MS methodologies for NSAID analysis are presented.  相似文献   

19.
An analytical method was developed and tested for four different groups of veterinary antibiotics in both river water and sediment matrices. Solid phase extraction (SPE) was used to enrich and to clean up the aqueous sample. Also, Mcllvaine and ammonium hydroxide buffer solutions were used to extract the compounds from the sediment matrix. High performance liquid chromatography (HPLC) equipped with tandem mass spectrometry (MS/MS) was used to separate and quantify the samples. The range of recoveries (in percent) for tetracyclines (TCs), sulfonamides (SAs), macrolides (MLs), and ionophore polyethers (IPs) in the water matrix were 102.2–124.8, 76.6–124.3, 89.5–114.7, 82.7–117.5 with 1–13 (%) of relative standard deviation respectively with three different concentrations. For sediment, the percent recovery ranges were 32.8–114.8, 62.4–108.9, 53.4–128.4 and 51.3–105.4 for TCs, SAs, MLs and IPs, respectively. The relative standard deviation ranged from 16 – 27 (%) over three different concentrations. The limit of quantification (LOQ) was determined by two different methods and calculated to be in the range of 0.01–0.04 μg/l and 0.3–2.5 μg/kg for TCs, SAs, and MLs in water and sediment, respectively. For IPs, the LOQ was 0.001–0.003 μg/l in river water and 0.4–3.6 μg/kg for sediment. The sediment concentration measured in an agriculture-influenced river was much higher than in the overlying water matrix, indicating a high degree of sediment partitioning for these compounds.  相似文献   

20.
Atmospheric pressure (AP) GC/MS was first introduced by Horning et al. [E.C. Horning, M.G. Horning, D.I. Carroll, I. Dzidic, R.N. Stillwell, Anal. Chem. 45 (1973) 936] using 63Ni as a beta-emitter for ionization. Because, at the time special instrumentation was required, the technique was only applied with consistency to negative ion environmental studies where high sensitivity was required [T. Kinouchi, A.T.L. Miranda, L.G. Rushing, F.A. Beland, W.A. Korfmacher, J. High Resolut. Chromatogr., Chromatogr. Commun. 13 (1990) 281]. Currently, AP ion sources are commonly available on LC/MS instruments and recently a method was reported for converting an AP-LC/MS ion source to a combination AP-LC/MS:GC/MS source [C.N. McEwen, R.G. McKay, J. Am. Soc. Mass Spectrom. 16 (2005) 1730]. Here, we report the use of atmospheric pressure photoionization (APPI) with GC/MS and compare this to AP chemical ionization (APCI) GC/MS and electron ionization (EI) GC/MS. Using a nitrogen purge gas, we observe excellent chromatographic resolution and abundant molecular M+ and MH+ ions as well as structurally significant fragment ions. Comparison of a 9.8 eV UV lamp with a 10.6 eV lamp, as expected, shows that the higher energy lamp gives more universal ionization and more fragment ions than the lower energy lamp. While there are clear differences in the fragment ions observed by APPI-MS versus EI-MS, there are also similarities. As might be expected from the ionization mechanism, APPI ionization is similar to low energy EI. These odd electron fragment ions are useful in identifying unknown compounds by comparison to mass spectra in computer libraries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号