1.
This work presents a flow injection (FI) system that was developed for determination of iodate. The system utilizes the oxidation of iodide by the analyte to iodine, which subsequently forms tri-iodide. In the presence of starch, the blue I3–starch complex is developed within the sample zone and can be colorimetrically detected at 590 nm. Optimization was carried out to make the system suitable for quantitating iodate added to table salts. To prevent accumulation of the blue complex residue on walls of tubing and the flow cell, a port was placed in the system for injection of 10−3 M thiosulfate plug (100 μl). An injection of this cleaning solution after each sample injection is recommended to avoid positive baseline shift. By means of the paired t-test, the amounts of iodine (mg I kg−1) were statistically compared with the results determined by titration and by iodide ion selective electrode. No significant disagreement at 95% confidence was observed. The proposed system is very simple, uses common chemicals and provides rapid analysis (65 injections per h) with high precision (R.S.D.=0.66%, n=10). A detection limit of 2 mg I kg−1 salt can be achieved.  相似文献   

2.
This paper reports the development of a new approach for total phenol distillation using a focussed microwave oven, aiming its determination in petroleum refinery effluents and sour waters. In the procedure, 25 ml of sample is distilled during 15 min at 210 W power. At these conditions, recoveries as high as 95% are obtained, making possible the determination of total phenol in the samples without any interference and in a time significantly lower than that required by the reference method. In the course of the research, the influence of the distilled volume was investigated and a Doehlert matrix was employed for the multivariate optimization of the irradiation power and time. Quantification of phenol was spectrophotometrically performed in a FIA system, exploring classical reaction of phenol with 4-amineantipyrine and ferricyanide. Aqueous standards solutions of phenol could be directly injected in the FIA system for calibration purposes, making the procedure very simple and low time-consuming. A detection limit of 10 μg l−1 was achieved as well as a quantification limit of 33 μg l−1, becoming the procedure very suitable to be applied in the control of total phenols in effluents from petroleum industry.  相似文献   

3.
在碱性条件下,佐米曲谱坦对鲁米诺-K3[Fe(CN)6]化学发光体系有较强的抑制作用,据此建立了佐米曲谱坦的流动注射化学发光分析法。该法的化学发光抑制值ΔI与佐米曲谱坦质量浓度在2.0×10-6~1.2×10-4g/mL范围内,呈良好的线性关系,检出限为7.6×10-7g/mL。对2.5×10-5g/mL佐米曲谱坦测定的相对标准偏差为1.2%(n=11)。方法适用于佐米曲谱坦片中佐米曲谱坦的测定。  相似文献   

4.
Two new flow methods, flow injection analysis (FIA) and sequential injection analysis (SIA), for the spectrophotometric determination of Cu(II) in water at trace levels have been developed and optimised. Both methods are based on the reaction with oxalic acid bis(cyclohexylidene hydrazide) (cuprizone) in alkaline media. The two procedures have been developed for the final aim to compare their performances and to offer new rapid heavy metals analysis tools, avoiding the use of extraction steps. A detailed study of the physico-chemical parameters affecting the systems performances has been carried out. The reversed FIA and sandwich SIA approaches offered the best sensitivity. In both cases, an extremely good linearity has been obtained within the range 0.06-4 μg ml−1 (correlation coefficient r=0.9999), whereas the observed detection limits were 0.013 and 0.004 μg ml−1, for FIA and SIA, respectively. Furthermore, due to the great similarity of the diffusion zones in the reaction slugs, our approach offers the opportunity to compare the two methods in analogous conditions. This SIA method, besides keeping its typical reagent saving features, offered analytical performances equivalent to those of FIA. To obtain these results, an original “stop-flow like” method was successfully employed in the SIA approach. Both methods were validated by analysis of real water samples, after copper addition, and certified reference samples of fortified and waste waters.  相似文献   

5.
流动注射化学发光法测定那格列奈   总被引:2,自引:0,他引:2  
在碱性介质中,那格列奈对Luminol-H2O2体系的化学发光有很强的抑制作用,据此建立了流动注射化学发光抑制法测定那格列奈的新方法.该法的化学发光抑制值△I与那格列奈的质量浓度在2.0×10-8~1.0×10-6 g/mL范围内,呈良好的线性关系,检出限为1.4×10-8 g/mL;对4.0×10-7 g/mL那格列奈连续进行11次平行测定,相对标准偏差为1.0%;通过对荧光光谱的研究,对机理进行了初步探讨.  相似文献   

6.
A flow injection method with on-line solid sample dissolution was developed for the determination of fluoride in phosphate rock. The fluoride was selectively leached (98-102.4 % recovery) from a 50-mg powdered phosphate rock sample with 0.50 M citric acid. Using the zone sampling technique the fluoride in the buffered leachate was determined by injecting 87 μL into the carrier stream using a fluoride ion-selective electrode detector. The sensing element of the electrode was housed in a home-made sleeve-type flow-through cell. On-line solid sample digestion with 0.50 M citric acid at 55 °C resulted in minimum dissolution of interfering iron and aluminum ions with improved accuracy and calibration linearity. The incorporation of relatively high level of fluoride in the carrier stream (40 μg mL−1) facilitated the determination of high levels of fluoride in phosphate rock (up to 4.1%) with out the need for excessive on-line dilution.The optimized flow system was applied for the determination of fluoride in phosphate rocks samples and a reference material at a rate of nine samples per hour with a relative standard deviation (n = 5) of 2.95-4.0 %. Comparison of the proposed flow injection method with the standard method, which involves steam distillation from sulfuric acid solution and manual titration with thorium nitrate, showed no evidence of bias at the 95% confidence level.  相似文献   

7.
In this study, flow injection-cloud point extraction (FI-CPE) of iron and copper in food samples by flame atomic absorption spectrometric determination was described. Triton X-114 non-ionic surfactant and Eriochrome Cyanine R (ECR) have been used as an extraction medium and a chelating agent, respectively. The amounts of Triton X-114, ECR and the pH value necessary for extraction were carefully optimized. In addition, several parameters of the FI-CPE system, including sample loading rate, column dimension, type of packing material, eluent flow rate were investigated and analytical characteristics of the method were evaluated. Under optimum conditions, detection limits of 0.33 ng/mL and 0.57 ng/mL and quantification limits of 1.1 ng/mL and 1.9 ng/mL for iron and copper along with enrichment factors of 141 and 99 were obtained, respectively. The calibration was linear over the range 1.5-25 ng/mL and 1.0-35 ng/mL for iron and copper, respectively. The proposed CPE technique has been successfully applied for the determination of iron and copper ions in certified reference materials (NCS DC 73349—bush, branches and leaves; and TM-23.2—fortified water), water samples (mineral and sea water) and food samples (vegetables, bread and hazelnut) with high efficiency.  相似文献   

8.
The presence of sulphate constitutes a serious interference in the usual zirconium lake-based spectrophotometric method for the determination of fluoride in water. In this report, full spectral data have been recorded for the zirconium lake of 2-(parasulfophenylazo)-1,8-dihydroxy-3,6-naphthalene-disulfonate (SPADNS) in the simultaneous presence of fluoride and sulphate, as obtained with a flow injection system with a diode-array detector. The information has been processed with partial least-squares (PLS) multivariate calibration. Adequate modeling using a sixteen-sample calibration set allows fluoride to be determined in ground waters by the automated flow injection method, even in the presence of sulphate in concentrations up to 1000 mg l−1. In the calibration range 0-1.50 mg l−1 for fluoride, the limit of detection is 0.1 mg l−1. The fluoride contents in real samples, as determined with the present method, were satisfactorily compared with those provided by ion selective potentiometry.  相似文献   

9.
This paper reports the development of a new methodology for the determination of cobalt in biological samples by using a flow injection system with loaded DPTH-gel as solid phase to preconcentrate analytes. The procedure is based on the on-line preconcentration of cobalt on a microcolumn of 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The trapped cobalt is then eluted with 1% tartaric acid and 1% citric acid (7.1 mL) and determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). The analytical figures of merit for the determination of cobalt are as follows: detection limit (3S), 8.5 ng mL–1; precision (RSD), 5.8% for 100 ng mL–1 of cobalt; enrichment factor, 13 (using 7.3 mL of sample); sampling frequency, 40 h–1 using a 60-s preconcentration time. For a 120-s preconcentration time (14.6 mL of sample volume) a detection limit of 5.7 ng mL–1, an RSD under 5% at 50 ng mL–1, an enrichment factor of 25, and a sampling frequency of 24 h–1 were reported. The precision and accuracy of the method were checked by analysis of biological certified reference materials.  相似文献   

10.
A new flow injection (FI) method is reported for the spectrophotometric determination of fosfestrol (diethyl-stilbestrol (DES) diphosphate) in pharmaceutical formulations. The proposed method is based on the on-line hydrolysis of the analyte by alkaline phosphatase (Al-Pase) using a “chasing zones” FI manifold. The orthophosphate ions, thus, generated are determined spectrophotometrically (λmax=690 nm) using the molybdenum blue approach. The chemical and FI variables affecting the enzymatic reaction were investigated. The proposed method is very precise (sr=1.1% at 1×10−4 mol l−1 fosfestrol, n=12), fast (allowing up to 40 samples h−1 to be analyzed) and has a determination range of 2×10−5 to 2×10−4 mol l−1, with a satisfactory 3σ detection limit of 5×10−6 mol l−1. The method was shown to provide accurate determinations of the fosfestrol concentration in a pharmaceutical formulation, giving relative errors, er, of +0.6 and −0.5% compared to the value stated by the supplier (Asta Medica Inc.) and the concentration derived using a method recommended by the United States Pharmacopoeia XXI, respectively. In addition, the average recoveries of known amounts of the analyte ranged between 99.2 and 101.2%.  相似文献   

11.
A flow injection analysis (FIA) catalytic spectrophotometric method for the determination of dissolved iron in seawater was further developed to yield a more sensitive assay with a low detection limit. The method employs an initial sample acidification step followed by an iron pre-concentration step involving an in-line 8-hydroxy-quinoline (8-HQ) metal-chelating resin column. The copper capacity and elution efficiency, as well as the iron FIA performance of three trace-metal clean resins were compared, resulting in the selection of a clean silica gel support for the 8-HQ ligand. The concentrated sample is eluted from the resin with an acidic carrier and mixed with reagents, initiating an iron-catalyzed, color-forming reaction. Increasing the reaction temperature from 18 to 30 °C doubled the sensitivity; reaction temperature control was necessary to obtain good reproducibility in the field. Reagent blanks were as low as 0.05 nM and a detection limit of 0.016 nM was obtained from three times the S.D. of a 0.06 nM seawater sample repeated six times. A 0.06 nM detection limit was calculated from shipboard experiments where total dissolved iron was determined for 10 different samples from the same station. The instrumental sensitivity and precision evolved to the point where the blank associated with the technique is the major factor influencing its detection limit.  相似文献   

12.
Hollow fiber-based liquid-liquid-liquid microextraction (HF-LLLME) followed by flow injection analysis and diode array detection (FIA-DAD) was applied as a simple and sensitive quantitative method for the determination of phenazopyridine in urine and plasma samples. Flow injection system included a conventional HPLC system (without a chromatographic column) and a diode array detector. The extraction of phenazopyridine was carried out using diphenyl ether as the organic phase for filling the pores of the hollow fiber wall, and 0.1 M H(2)SO(4) solution as acceptor phase in the lumen of the fiber. The factors affecting the HF-LLLME and flow injection analysis including type of organic solvent, pH of donor phase, extraction temperature, extraction time, stirring rate, and pH of mobile phase were investigated and the optimal extraction conditions were established. With the consumption of 5 mL of sample solution, the enrichment factor was about 230. The limit of detection was 0.5 μg/L with inter- and intra-day precision being (RSD%) 6.9 and 4.9, respectively. Excellent linearity was found between 5 and 200 μg/L.  相似文献   

13.
An analytical flow-injection procedure based on PbSO4 colloidal formation is proposed as a turbidimetric determination of sulphate in natural waters. Ethanol-water was used as a medium in order to improve the sensibility of the method. Both chemical and flow variables as well as interfering species were studied. A detection limit of 0.3 μg SO2−4 ml−1 was found, and the analytical range (according to Beer's law) was 2–20 μg SO2−4 ml−1. The precision was better than 3% R.S.D. and the sample throughput was ca. 35 h−1. The method, when compared with a standard methodology, gave good results when applied to water analysis.  相似文献   

14.
Flow injection (FI) and sequential injection (SI) systems with anodic stripping voltammetric detection have been exploited for simultaneous determination of some metals. A pre-plated mercury film on a glassy carbon disc electrode was used as a working electrode in both systems. The same film can be repeatedly applied for at least 50 analysis cycles, thus reducing the mercury consumption and waste. A single line FI voltammetric system using an acetate buffer as a carrier and an electrolyte solution was employed. An injected standard/sample zone was mixed with the buffer in a mixing coil before entering a flow cell. Metal ions were deposited on the working electrode by applying a potential of −1.1 V vs Ag/AgCl reference electrode. The stripping was performed by anodically scanning potential of working electrode to +0.25 V, resulting a voltammogram. Effects of acetate buffer concentration, flow rate and sample volume were investigated. Under the selected condition, detection limits of 1 μg l−1 for Cd(II), 18 μg l−1 for Cu(II), 2 μg l−1 for Pb(II) and 17 μg l−1 for Zn(II) with precisions of 2–5% (n=11) were obtained. The SI voltammetric system was similar to the FI system and using an acetate buffer as a carrier solution. The SI system was operated by a PC via in-house written software and employing an autotitrator as a syringe pump. Standard/sample was aspirated and the zone was then sent to a flow cell for measurement. Detection limits for Cd(II), Cu(II), Pb(II) and Zn(II) were 6, 3, 10 and 470 μg l−1, respectively. Applications to water samples were demonstrated. A homemade UV-digester was used for removing organic matters in the wastewater samples prior to analysis by the proposed voltammetric systems.  相似文献   

15.
Pyridylazo and thiazolylazo reagents are synthetic dyes widely used in analytical chemistry. These reagents are also very attractive for use in preconcentration systems. This paper covers the application of pyridylazo and thiazolylazo reagents in flow injection systems for the determination of metals. The article discusses flow injection preconcentration systems with solid-phase extraction, precipitation and cloud point extraction. The use of pyridylazo and thiazolylazo reagents in flow injection detection systems is also presented. The relative advantages and drawbacks of these systems are discussed. The application of pyridylazo and thiazolylazo reagents in new systems is presented in the concluding part of this review article.  相似文献   

16.
A new, rapid, sensitive, non-extraction batch, and flow injection spectrophotometric method for the determination of cationic surfactants (CSs) such as cetyltrimethyl ammonium bromide (CTAB), tetra-n-butyl ammonium chloride (TBAC) and cetylpyridinium chloride (CPC) is proposed. The method is based on the interaction of cationic surfactants with eriochrome black-T to form an ion-association complex. This complex has strong absorbance at 708 nm. The effects of chemical parameters and FIA variables on the determination of cationic surfactants were studied in detail, especially for CTAB. Under optimum conditions, the two linear calibration ranges of the method are 3.0 × 10−6 to 5.0 × 10−3 mol L−1 CTAB, CPB and DTAB for the batch spectrophotometric method and 2.0 × 10−6 to 2.0 × 10−4 mol L−1 CTAB, CPB and TBC for the flow injection spectrophotometric method. The sample throughput was 35 ± 5 samples h−1 at room temperature. The relative standard deviations for 10 replicates of analysis of (2.0, 0.6 and 0.2) × 10−4 mol L−1 CTAB were 1.2, 1.3, and 0.8%, respectively. In addition, the influence of potential interfering substances on the determination of cationic surfactants was studied. The proposed method is simple and rapid, using no toxic organic solvents. It was applied to the determination of trace CS in industrial wastewater with satisfactory results.  相似文献   

17.
Almeida MI  Estela JM  Segundo MA  Cerdà V 《Talanta》2011,84(5):1244-1252
A new design of a membraneless gas-diffusion (MGD) unit coupled to a multisyringe flow injection system is proposed. The spectrophotometric determination of ammonium using an acid-base indicator was chosen to show the feasibility of this approach. Hence, in alkaline medium, ammonium ions are transformed into ammonia (donor channel) which diffuses through the headspace into the acceptor stream (bromothymol blue solution), causing a pH change and subsequently a colour change. The exploitation of the enhanced potentialities of this re-designed MGD device was the main purpose of the present work. Hence, several strategies concerning flow management were studied seeking to characterize and improve the analytical features of the methodology and moreover, untreated environmental samples were analysed without previous filtration. Consequently, stopped flow in acceptor channel with continuous flow in donor channel was chosen for the application to wastewater and spiked river water samples. A linear concentration range between 10.0 and 50.0 mg L−1 of NH4+, a limit of detection of 2.20 mg L−1 and a determination frequency of 11 h−1 were obtained.  相似文献   

18.
基于苯胺与亚硝酸盐的重氮化反应及反应产物与甲萘酚的显色,借助流动分析技术,实现了海水中苯胺含量的分析测定。体系以30.9g/L的NaCl做载液、人工海水配制标准样品,对各个影响因素进行了优化。苯胺浓度在0.01~1.0mg/L范围内与相对峰高呈线性关系,线性方程ΔH(mV)=200.53ρ+1.0728(n=8,ρ为苯胺浓度mg/L),相关系数R2=0.9982。方法的检出限(3σ)为0.005mg/L,相对标准偏差(RSD)为4.8%(n=11)。考察了共存离子、不同盐度样品对分析测定的影响。用于实际海水样品的分析,回收率为95.8%~106.6%。  相似文献   

19.
Saad B  Ariffin M  Saleh MI 《Talanta》1998,47(5):89-1236
A flow injection potentiometric method for the rapid determination of paraquat in herbicide formulations and biological samples is described. It is based on the utilization of a flow-through potentiometric detector containing polyvinyl chloride-immobilised octamethylcyclotetrasiloxane, a lipophilic plasticizer (tetra-n-undecyl 3,3′,4,4′-benzophenone tetracarboxylate) and membrane additive potassium tetrakis(4-chlorophenyl)borate. The detector was minimally interfered by the presence of constituents such as Na+, K+, Ca2+, Mg2+, glucose, urea, lactic and citric acids at physiological levels, respectively. Good correlation between results of the proposed method and HPLC for the formulation samples was found, while results for the determination of paraquat in biological samples such as urine, vomitus and stomach washout was less satisfactory.  相似文献   

20.
Xiao-Qing Zhao 《Talanta》2009,80(1):242-385
A rapid and sensitive flow injection fluorometry has been developed for the determination of formaldehyde based on the microwave on-line accelerating its Hantzsch reaction with cyclohexane-1,3-dione. Under the optimized conditions, the fluorescent intensity is proportional to formaldehyde content in the range from 0.05 ng/mL to 2.000 μg/mL. The detection limit (S/N = 3) is 0.02 ng/mL and the analytical frequency is 28 injections per hour. The relative standard deviations are 2.2% and 3.1% for eleven injections of 0.100 and 0.001 μg/mL of formaldehyde, respectively. With the assistance of microwave irradiation, a best sensitive fluorometry was established for the determination of formaldehyde at a high analytical frequency. This method was successfully applied to food analysis without requiring any sample pretreatment, and the determination results were correlated well with those obtained by the standard method with a sample pretreatment of steam distillation.  相似文献   