首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The polarographic behaviour of 2-nitronaphthalene was investigated by DC tast polarography (DCTP) and differential pulse polarography (DPP), both at a dropping mercury electrode, and differential pulse voltammetry and adsorptive stripping voltammetry, both at a hanging mercury drop electrode. Optimum conditions have been found for the determination of 2-nitronaphthalene by the given methods in the concentration ranges of 2×10–6–1×10–4, 2×10–7–1×10–4, 1×10–8–1×10–4 and 2×10–9–1×10–8 M, respectively. Practical applicability of these techniques was demonstrated by the determination of 2-nitronaphthalene in drinking and river water after its preliminary separation and preconcentration using liquid–liquid and solid-phase extraction with limits of determination of 3×10–10 M (drinking water) and 3×10–9 M (river water).  相似文献   

2.
Electrochemical studies of famotidine were carried out using voltammetric techniques: cyclic voltammetry, linear sweep and square wave adsorptive stripping voltammetry. The dependence of the current on pH, buffer concentration, nature of the buffer, and scan rate was investigated. The best results for the determination of famotidine were obtained in MOPS buffer solution at pH 6.7. This electroanalytical procedure enabled to determine famotidine in the concentration range 1 × 10−9–4 × 10−8 mol L−1 by linear sweep adsorptive stripping voltammetry (LS AdSV) and 5 × 10−10–6 × 10−8 mol L−1 by square wave adsorptive stripping voltammetry (SW AdSV). Repeatability, precision and accuracy of the developed methods were checked. The detection and quantification limits were found to be 1.8 × 10−10 and 6.2 × 10−10 mol L−1 for LS AdSV and 4.9 × 10−11 and 1.6 × 10−10 mol L−1 for SW AdSV, respectively. The method was applied for the determination of famotidine in urine.  相似文献   

3.
Tap water samples (Assiut city, lie in the middle north of upper Egypt, approx. 370 km from Cairo, January-March, 2002) were taken from the eight sampling sites of different locations at Assiut city. The samples are analyzed to determine the total content of cadmium, copper, lead and zinc by differential pulse anodic stripping voltammetry (DPASV) while nickel and cobalt are determined by a new simple differential pulse adsorptive stripping voltammetry (DPAdSV), using dimethylglyoxime (DMG) as the complexing agent. This method uses sodium sulfite as the supporting electrolyte, which facilitates the removal of oxygen interference without the traditional necessity of purging with inert gas. The effect of various parameters was studied using DPASV (for Cd, Pb, Cu and Zn) and AdSV (for Ni and Co) methods. Subsequently, under the so found experimental conditions, the stability of calibration curves and the detection limits (μg/l) have been determined. The data achieved (for all metals utility) are comparable to those measured by the graphite furnace atomic absorption spectrophotometric (GF-AAS) method. The effects of the interferences between these metal ions have been investigated. Moreover, the effect of storage was discussed and the obtained results were compared favorably with standard official methods. Statistical analysis of the database exhibits applicability and the accuracy of the techniques. The results obtained from the two techniques (Voltammetry and GF-AAS) are in very good agreements in the most tap water samples.  相似文献   

4.
Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA. Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically, resulting in peak current linearly dependent on lutetium (III) concentration. Less than 0.4 ng mL−1 lutetium could be detected after a 2 min deposition.   相似文献   

5.
Cyclic voltammetry was used to investigate the electrochemical behaviour of triclosan (2,2,4′-trichloro-2′-hydroxydiphenyl ether) at a screen-printed carbon electrode (SPCE). It was found that a single anodic peak occurred over the pH range 6.0–12.0; this peak was considered to result from an irreversible oxidation reaction at the phenolic moiety. A plot of Ep versus pH was constructed and from the break point a pKa value of 7.9 was obtained, thus agreeing with the literature value. Detailed voltammetric studies were performed at pH 10, where the analyte exists as an anion. It was demonstrated that, at an initial potential of 0 V, the anion underwent electrosorption prior to electrochemical oxidation. The oxidation reaction appeared to involve a one-electron transfer, as deduced from a calculated na value of 0.5; the same value was obtained at pH 7.0. In contrast to triclosan, triclosan monophosphate was found to be electrochemically inactive when subjected to voltammetry under the stated conditions.

The electrochemical oxidation of triclosan at a SPCE was exploited for its determination (0.3%) in commercial toothpaste and mouthrinse products using differential pulse voltammetry. The recovery and precision data indicated that this approach may have application in routine quality control analysis.  相似文献   


6.
M. Pérez-Ortiz 《Talanta》2010,82(1):398-630
In this work, the electrochemical behavior and the analytical application of atomoxetine, a selective noradrenaline reuptake inhibitor, are studied. Atomoxetine, studied by differential pulse voltammetry and cyclic voltammetry on a glassy carbon electrode, exhibited an anodic response in aqueous media with pH between 1.5 and 7. In non-aqueous medium (acetonitrile), the drug exhibited two irreversible oxidation peaks that are diffusion controlled. From chronocoulometric studies in acetonitrile, it was determined that each oxidation signal involves two and four electrons, respectively. For analytical purposes, a differential pulse voltammetry technique in 0.1 mol L−1 perchloric acid was selected, which exhibited adequate figures of merit. The percent recovery was 96.6 ± 1.2 and the detection and quantitation limits were 6.9 × 10−5 and 1.0 × 10−4 mol L−1, respectively. Also, results indicate that excipients do not interfere with the oxidation signal of atomoxetine, which leads to the conclusion that the developed method is satisfactorily selective for atomoxetine quantification in pharmaceuticals with no prior separation or extraction necessary. Finally, the proposed voltammetric method was successfully applied to both the assay and the uniformity content of atomoxetine in capsules. For comparison, high-performance liquid chromatography analysis was also performed.  相似文献   

7.
In this study a reduction square wave voltammetric method was developed and validated for the direct determination of ciprofloxacin (CIP) in pharmaceutical formulation and biological fluid using hanging mercury dropping electrode (HMDE) surface. Best results were obtained for the quantitative determination of CIP in 0.02 M Britton-Robinson buffer at pH 2.5 and at a potential of ?1300 mV vs. Ag/AgCl reference electrode. Various experimental and instrumental parameters affecting the peak current and potential of CIP electrochemical reduction were investigated and optimized. The monitored peak current was directly proportional to the concentration of CIP, where it exhibited a linear response in the range 3.0 × 10?7–2 × 10?6 M (r = 0.99). The accuracy of the proposed method was concluded based on the value of mean recovery of 98 ± 0.72 % with RSD of 0.181 % at a detection limit of 7 × 10?9 M. Possible interferences by various substances usually present in pharmaceutical formulations have been also evaluated. After validating the proposed method, the applicability of this voltammetric method was demonstrated by estimating CIP in its pharmaceutical formulation and spiked human urine, where values of mean recoveries of 97 ± 1.0% and 108.0 ± 2.0% were obtained, respectively.  相似文献   

8.
大黄素的吸附溶出伏安研究   总被引:1,自引:0,他引:1  
研究了大黄素在甲醇、二氧六环和水的混合溶剂中以1%硼砂为支持电解质在静汞电极上的吸附伏安行为。建立了用微分脉冲吸附溶出伏安法测定其含量的新方法。在-030V(vsAg/AgCl)电位下吸附富集,可得一灵敏的还原溶出峰,峰电位-075V,浓度在5×10-8~5×10-9mol/L范围内与峰电流具有良好的线性关系,最低检出限为1×10-9mol/L。该法用于含有大黄素体系的测定简便、快速、可靠。  相似文献   

9.
Dimenhydrinate exhibits a single adsorptive stripping peak at a hanging mercury drop electrode after accumulation at 0.0V vs Ag/AgCl electrode at pH 3.8 (acetate buffer). The addition of trace amounts of copper ions enhanced the dimenhydrinate peak and its height depends on the concentration of each dimenhydrinate and Cu2+. The adsorptive stripping response was evaluated with respect to accumulation time and potential, concentration dependence, electrolyte, the presence of other purines, surfactants and other metal ions, and some variables. The calibration graph for dimenhydrinate determination is linear over the range 2.0×10–8–2.0×10–7 M (pre-concentration for 60s). The correlation factor is found to be 0.985 and RSD is 3.2% at 1.0×10–7 M. Detection limit is 1.0×10–8 M after 5 min accumulation. The determination of dimenhydrinate in pharmaceutical formulations by the proposed method is also reported.  相似文献   

10.
An indirect voltammetric method is described for determination of cyanide ions and hydrogen cyanide, using the effect of cyanide on cathodic adsorptive stripping peak height of Cu-adenine. The method is based on competitive Cu complex formation reaction between adenine at the electrode surface and CN ions in solution. Under the optimum experimental conditions (pH=6.42 Britton-Robinson buffer, 1×10−4 M copper and 8×10−7 M adenine), the linear decrease of the peak current of Cu-adenine was observed, when the cyanide concentration was increased from 5×10−8 to 8×10−7 M. The detection limit was obtained as 1×10−8 M for 60 s accumulation time. The relative standard deviations for six measurements were 4 and 2% for the cyanide concentrations of 5×10−8 and 2×10−7 M, respectively. The method was applied to the determination of cyanide in various industrial waste waters such as electroplating waste water and also for determination of hydrogen cyanide in air samples.  相似文献   

11.
A linear sweep adsorptive stripping voltammetric method for the determination of netilmicin in the presence of formaldehyde has been proposed for the first time. In the presence of 3.0×10−3 g ml−1 formaldehyde, netilmicin exhibits a sensitive cathodic peak at −1.30 V (vs. the saturated calomel electrode, SCE) in a medium of Britton–Robinson buffer (pH 8.7) with a scan rate of 100 mV s−1 after a preconcentration period of 120 s at −1.10 V (vs. SCE). The peak current showed a linear dependence on the netilmicin concentration over the range 4.2×10−9–1.0×10−7 g ml−1. The achieved limits of detection and quantitation were 1.0×10−10 and 3.3×10−10 g ml−1 netilmicin, respectively. It was deduced from the experiments that the amine–aldehyde condensation product formed between netilmicin and formaldehyde is mainly responsible for the appearance of the peak. The electrochemical behavior of netilmicin in the presence of formaldehyde has been studied. The method was applied to the direct determination of netilmicin in injectable formulations and spiked human urine and serum samples.   相似文献   

12.
采用循环伏安法和线性扫描伏安法对没食子酸在电活化玻碳电极上的电化学行为进行了研究。玻碳电极在pH7.0的磷酸盐缓冲溶液中,用恒电位法在1.7 V电位阳极氧化400 s。然后在pH3.0的柠檬酸盐缓冲溶液中,没食子酸在0.479 V和0.442 V处有一良好的氧化还原峰,在0.02~0.40 V s-1范围内,其氧化峰电流与扫描速率呈良好线性关系,表明电极过程为受吸附控制的准可逆过程。线性循环伏安法的氧化峰电流与没食子酸浓度1×10-6~1×10-4mol L-1范围内呈良好的线性关系(r=0.980 6),检出限为7.6×10-7mol L-1(S/N=3)。该方法操作简便,重现性较好,并应用此法分析了健民咽喉片剂中的没食子酸的含量。  相似文献   

13.
The electrochemical reduction and adsorptive voltammetric behaviour of pravastatin have been studied by means of cyclic and square-wave voltammetry at a hanging mercury-drop electrode in electrolytes of different pH. Within the entire pH range (2.0–9.0) in Britton–Robinson buffer, pravastatin gave rise to a single voltammetric peak in the potential interval from −1.22 to −1.44 V, depending on pravastatin concentration. It was found that the reduction of pravastatin proceeds via a relatively stable intermediate, which is transformed to the final electroinactive product by a coupled chemical reaction or can be re-oxidized back to pravastatin. The rate of chemical transformation is controlled by the proton concentration. The electrode mechanism has the properties of a surface redox reaction. A sensitive analytical method for trace analysis of pravastatin based on the adsorptive stripping technique has been developed. The calibration plot was linear in the range 8×10−8–5×10−7 mol L−1. Application of the square-wave voltammetric method to determination of pravastatin in a pharmaceutical dosage form, without sample pretreatment, resulted in acceptable deviation from the stated concentration.  相似文献   

14.
In situ mercury film electrode produced in the presence of thiocyanate has been shown extremely useful for highly sensitive adsorptive stripping voltammetric measurements of atrazine down to sub-μg L−1 level. Operational parameters have been optimized and the stripping voltammetric performance has been investigated using square wave scans. The adsorptive stripping response is linear over the range of 0.5-60 μg L−1 atrazine, with a detection limit of 0.024 μg L−1. The method has been applied to the determination of atrazine in soil and water samples.  相似文献   

15.
Safavi A  Maleki N  Shahbaazi HR 《Talanta》2006,68(4):1113-1119
A sensitive method for the determination of chromium ion(VI) in complex matrices such as crude oil and sludge is presented based on the decreasing effect of Cr(VI) on cathodic adsorptive stripping peak height of Cu-adenine complex. Under the optimum experimental conditions (pH 7.5 Britton-Robinson buffer, 5 × 10−5 M copper, 8 × 10−6 M adenine and accumulation potential −250 mV versus Ag/AgCl), a linear decrease of the peak current of Cu-adenine was observed, when the chromium(VI) concentration was increased from 5 μg L−1 to 120 μg L−1. Detection limit of 2 μg L−1 was achieved for 120 s accumulation time. The relative standard deviations (R.S.D., %) were 1.8% and 4% for chromium(VI) concentrations of 18 μg L−1 and 100 μg L−1, respectively. The method was applied to the determination of chromium(VI) in the presence of high levels of chromium(III), in various real samples such as crude oil, crude oil tank button sludge, waste water and tap water samples. Effects of foreign ions and surfactants on the voltammetric peak and the influences of instrumental and analytical parameters were investigated in detail. The accuracy of the results was checked by ICP and/or AA.  相似文献   

16.
灰黄霉素在0.1mol LHAc NaAc底液(pH5.0)中,产生灵敏的线性扫描极谱导数峰,峰电位为-1.28V(vs.SCE),峰电流与灰黄霉素浓度在2.0×10-7~2.0×10-6mol L范围内成线性关系。用于灰黄霉素片剂的测定。用线性扫描和循环伏安法等手段研究体系的伏安行为,结果表明,该体系属具有吸附性的不可逆过程。  相似文献   

17.
The anodic voltammetric behavior of methotrexate was studied at glassy carbon electrode in acetate buffer (pH = 3.6) solution using cyclic, square-wave voltammetric and chronocoulometric techniques. The oxidation of methotrexate is an irreversible diffusion-controlled process. The oxidation mechanism was proposed and discussed in this work. The dependence of the current on pH, the concentration and nature of buffer, and instrumental parameters were investigated to optimize the experimental conditions for the determination of methotrexate. It was found that in the range of 8.0 × 10−7–2.0 × 10−5 mol/L, the currents measured by square-wave voltammetry presented a good linear property as a function of the concentrations of methotrexate. In addition, validation parameters, such as reproducibility, sensitivity and recovery were evaluated as well. The proposed method was also successfully applied for the determination of methotrexate in diluted human urine with good satisfactory.  相似文献   

18.
A sensitive procedure for determination of micro-traces of Co(II) by adsorptive stripping voltammetry is proposed. The procedure exploits the enhancement of the cobalt peak obtained by use of the system Co(II)–dimethylglyoxime–piperazine-1,4-bis(2-ethanesulfonic acid)–cetyltrimethylammonium bromide. Using the optimized conditions, a detection limit (based on the 3 criterion) for Co(II) of 1.2×10–11 mol L–1 (0.7 ng L–1) was achieved. The calibration plot for an accumulation time of 30 s was linear from 5×10–11 to 4×10–9 mol L–1. The procedure was validated by analysis of certified reference materials and natural water samples.  相似文献   

19.
The electrochemical oxidation of cisatracurium was investigated by cyclic voltammetry and differential pulse voltammetry at a carbon paste electrode and the experimental parameters have been optimized in order to obtain the optimum analytical signal. A differential pulse voltammetric method with carbon paste electrode is described for the determination of cisatracurium with detection limit of 0.38 μg/ml and quantitation limit of 1.26 μg/ml. The proposed method was applied to determine the content of cisatracurium in human urine and human serum, obtaining accurate and precise results.  相似文献   

20.
硫代硫酸根的溶出伏安吸附性质及应用   总被引:1,自引:0,他引:1  
在 0 .0 1mol·L-1LiNO3介质中 (pH 2 .70 )S2 O32 -有一灵敏的阴极溶出峰( - 0 .42V) ,其峰电流与S2 O32 -浓度在 1× 1 0 -7mol·L-1~ 4× 1 0 -6mol·L-1范围内有线性关系。当富集 2 0 0s时 ,检测限可达 5× 1 0 -8mol·L-1。溶出峰具有吸附性质 ,在悬汞电极上的吸附符合Frumkin等温式。测得在悬汞电极上的饱和吸附量为 1 .0 3× 1 0 -9mol·cm-2 。该方法用于PbS2 O3溶度积的测定 ,结果与文献值基本一致。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号