首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel spectrofluorimetric method for the determination of sulfite using rhodamine B hydrazide as fluorogenic reagent in the presence of polyoxyethylene sorbitan monooleate (Tween 80) surfactant micelles is described. The method is based on the mixture of sulfite with rhodamine B hydrazide, a colorless, non-fluorescent substance in Tween 80 surfactant micelles which gives rhodamine B-like fluorescence emission. The fluorescence intensity increase is linearly related to the concentration of sulfite in the range 5-800 ng ml−1 with a detection limit of 1.4 ng ml−1 (3σ). The optimal conditions for the detection of sulfite are evaluated and the possible detection mechanism is also discussed. The method has been successfully applied to the determination of total sulfite in wines and compares well with the standard iodimetric method.  相似文献   

2.
环境水样中痕量肼的荧光分析   总被引:3,自引:0,他引:3  
基于在硫酸介质中,肼与罗丹明6G反应,使其荧光增强,建立了一种荧光测定痕量肼的新方法。该方法线性范围2.0-14.0μg/L,检出限为0.62μg/L。可用于环境水样中肼含量的测定,并进行了回收实验,回收率为97%-107%。  相似文献   

3.
A new rhodamine derivative,N-(3-carboxy)acryloyl rhodamine B hydrazide(CARB),has been synthesized,and its unusual spectroscopic reaction with Cu2+ has been investigated.The derivative exhibits a rapid and reversible non-fluorescent absorption upon coordination to Cu2+,which is a rather unusual phenomenon for rhodamine B derivatives.Stoichiometric measurements using the Job's method and the molar ratio method reveal that one CARB molecule combines two Cu2+ ions,and the two Cu2+ ions play different roles:one ...  相似文献   

4.
Ling Mei  Yu Xiang  Na Li  Aijun Tong   《Talanta》2007,72(5):1717-1722
A new fluorescent probe, rhodamine B hydrazide oxalamide (RBHO), which shows very weak fluorescence, was synthesized, and its fluorescence could be substantially enhanced by the addition of copper ion. The probe shows a high selectivity and sensitivity to copper ion by forming a 1:1 complex in acetonitrile, and the chelating is reversible. Limit of detection for copper ion in acetonitrile was found to be 3.7 × 10−8 mol L−1. It was also found that copper ion could catalyze the hydrolysis of the probe in 50% (v/v) buffered (10 mM Tris–HCl, pH 7.0) water/acetonitrile giving a highly fluorescent product, and the fluorescence detection of copper ion was developed in this neutral buffered media with a detection limit of 6.4 × 10−7 mol L−1. Determination of copper ion in water and synthetic samples in the presence of different interfering metal ions was successfully carried out with the new probe RBHO.  相似文献   

5.
The incorporation of rhodamine B into polyurethane foam matrix was prepared by mixing the rhodamine B with polyol (polyether) prior to the addition of diisocyanate reagent to form the polyurethane foam material. Rhodamine B grafted polyurethane foam (Rod.B-PUF) was found to be very suitable for the separation and preconcentration of trivalent metal ions e.g. bismuth (III), antimony (III) and iron (III) from thiocyanate solutions. Bismuth and antimony were separated from concentrated acid medium (1–6 M H2SO4). Iron (III) was separated from pH 1 to 3. The kinetics of sorption of the Bi (III), Sb (III) and Fe (III) onto the Rod.B-PUF was found to be fast, the extraction is accomplished from 5 to 10 min with average values of half-life of sorption (t1/2) of 2.9 min. The average values of the Gibbs free energy (ΔG) for the sorption of metal ions onto Rod.B-PUF are ?6.6 kJ mol?1, which reflect the spontaneous nature of sorption process. The sorption mechanism of the metal ion onto Rod.B-PUF was also discussed.  相似文献   

6.
A new micelle-mediated cloud point extraction method is described for sensitive and selective determination of trace amounts of rhodamine B by spectrophotometry. The method is based on the cloud point extraction of rhodamine B from aqueous solution using Triton X-100 in acidic media. The extracted surfactant rich phase is diluted with water and its absorbance is measured at 563 nm by a spectophotometer. The effects of different operating parameters such as concentration of surfactant and salt, temperature and pH on the cloud point extraction of rhodamine B were studied in details and a set of optimum conditions were obtained. Under optimum conditions a linear calibration graph in the range of 5-550 ng mL−1 of rhodamine B in the initial solution with r = 0.9991 (n = 15) was obtained. Detection limit based on three times the standard deviation of the blank (3Sb) was 1.3 ng mL−1 (n = 10) and the relative standard deviation (R.S.D.) for 50 and 350 ng mL−1 of rhodamine B was 2.40 and 0.87% (n = 10), respectively. The method was applied for the determination of rhodamine B in soft pastel, hand washing liquid soap, matches tip and textile dyes mixture samples.  相似文献   

7.
A sensitive, selective and rapid spectrofluorimetric method is proposed for the determination of hydrogen peroxide using rhodamine B hydrazide as a fluorogenic substrate catalyzed by iron(III)-tetrasulfonatophthalocyanine. It is based on the oxidation of rhodamine B hydrazide, a colorless, non-fluorescent spirolactam hydrazide, by hydrogen peroxide which generates the highly fluorescent product rhodamine B. Under optimum conditions, the responses for hydrogen peroxide were linear from 2.0 × 10−8 to 2.0 × 10−6 mol L−1, with a detection limit of 3.7 × 10−9 mol L−1 in a 3.5 min reaction period. It can easily be incorporated into the determination of biochemical substances that produce hydrogen peroxide under catalytic oxidation in the presence of their oxidase. The possibility has been tested for the determination of glucose in human sera as an example.  相似文献   

8.
Chen X  Ma H 《Analytica chimica acta》2006,575(2):217-222
The spiro form fluorescein hydrazide (1) bearing a cleavable active bond is characterized as a highly selective and sensitive fluorescence probe for Cu2+. In 0.01 M Tris-HCl buffer (pH 7.2), the probe displays a highly selective fluorescence-on response to Cu2+ only, instead of other common metal ions. The reaction mechanism has been explored and proposed as that the hydrazide group of 1 recognizes and binds Cu2+, and the subsequent complexation of Cu2+ promotes hydrolytic cleavage of the amide bond, causing the release of fluorophore (fluorescein) and thereby the retrievement of fluorescence. Conditions for fluorescence measurement were optimized, generating a calibration curve that is linear over the concentration range of 0.1-10 μM Cu2+. The detection limit for Cu2+ is 64 nM based on 11 blank determinations (k = 3), also showing a highly sensitive feature. The fluorescence-on reaction described here has been used for the determination of trace Cu2+ in real biological fluids with satisfactory results.  相似文献   

9.
Summary A method is proposed for the extraction, separation, identification and quantitative measurement of rhodamine B in cosmetics samples The colour is extracted with a solution of orthophosphoric acid in either water or DMF (depending on the type of cosmetic) adsorbed on a polyamide column, and then eluted with water and methanol. Further clean-up of the extract is performed by means of a Bond Elut C-18 cartridge, from which rhodamine B is eluted with methanol-water (82). The final eluate is examined by HPLC. Chromatography is performed on a C-18 column with a gradient elution from 5050 to 7030 of acetonitrile-water, containing 0.1 M sodium perchlorate, in 15 min. A diodearray detector enables peak purity analysis. The method gives recovery values of approximately 90%, or better, and the reproducibility is within 4%.  相似文献   

10.
A fluorimetric sequential injection method for the determination of magnesium is proposed. The system is based on the complex formation between Mg(II) and 8-hydroxyquinoline-5-sulfonic acid (HQS). The reaction was carried out in the presence of ethylene glycol-bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid (EGTA) as a masking agent. Cetyltrimethylammonium chloride (HTAC) was employed as a fluorescence enhancer. The influence of several variables, such as reagent concentration, volumes and pH has been investigated. The reagent was prepared in a 0.1 M Tris-HCl buffer solution (pH 9). A detection limit of 12 mug l(-1) magnesium was obtained. The proposed method was applied to the determination of magnesium in natural waters.  相似文献   

11.
The chemiluminescence (CL) of the rhodamine B (RhB)-cerium(IV) system was investigated by flow-injection. Rhodamine B was suggested to be a suitable chemiluminescent reagent in acidic conditions. When the concentration of rhodamine B was 100 mg l−1 and cerium sulfate was 1.6 mmol l−1 in sulfuric acid, the chemiluminescent intensity was found to be highest by using 0.3 mol l−1 sulfuric acid as a carrier solution. The particular chemiluminescent system could tolerate such distinct acidic environments that it was utilized for detecting many compounds that are stable in acidic solutions. Furthermore, by virtue of IR, UV-Vis and luminescence spectroscopic measurements, the chemiluminescent behavior of rhodamine B was studied and a possible mechanism for this chemiluminescent reaction was proposed. The emitter was affirmed to be a radical species due to one of the oxidation products of RhB; the chemiluminescent emissive wavelength was about 425 nm.  相似文献   

12.
A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0×10−8 to 0.1 μg ml−1 for herring sperm DNA and 2.0×10−6 to 0.2 μg ml−1 for calf thymus DNA with 3σ detection limits of 8.3×10−9 μg ml−1 for herring sperm DNA and 3.5×10−7 μg ml−1 for calf thymus DNA, respectively. The relative standard deviation for 1.0×10−4 μg ml−1 herring sperm DNA was 0.99% and 2.0×10−3 μg ml−1 for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper.  相似文献   

13.
离子缔合物-萃取荧光光度法测定水中阴离子表面活性剂   总被引:15,自引:0,他引:15  
在 0 .2 5 mol/L H2 SO4 溶液中 ,罗丹明 B与阴离子表面活性剂形成离子缔合物 ,氯仿萃取后 ,于 5 5 0 nm处激发 ,荧光波长为 60 0 nm,对于十二烷基硫酸钠的线性范围为 0 .0 2 5~ 0 .4mg/L,RSD<2 .6%。方法可用于河水及生活废水中 1 0 -7~ 1 0 -6mol/L 阴离子表面活性剂的测定  相似文献   

14.
Xiang Y  Mei L  Li N  Tong A 《Analytica chimica acta》2007,581(1):132-136
A new fluorogenic method for the selective and sensitive determination of chromium(VI) in acidic water using rhodamine B hydrazide was developed. This method was based on the oxidation of non-fluorescent rhodamine B hydrazide by potassium dichromate in acidic aqueous conditions to give rhodamine B, which was highly fluorescent, as a product. With the optimum condition described, the fluorescence enhancement at 585 nm was linearly related to the concentration of chromium(VI) in the range of 5.0 × 10−8 to 2.0 × 10−6 mol L−1 (2.60-104 ng mL−1) with a correlation coefficient of R2 = 0.9993 (n = 18) and a detection limit of 5.5 × 10−9 mol L−1 (0.29 ng mL−1). The R.S.D. was 2.2% (n = 5). The proposed method was also applied to the determination of chromium(VI) in drinking water, river water and synthetic samples.  相似文献   

15.
罗丹明6G的溶液状态和荧光特性的研究   总被引:4,自引:0,他引:4  
何锡文  史长虹 《分析化学》1993,21(9):1008-1012
罗丹明6G的荧光性质和它的分子聚集态研究是一个重要的科研领域,所得之k_d值表明水溶液中形成罗丹明6G的双聚体。本文提出用荧光法测定k_d聚合常数,该法用于测定罗丹明6G的溶液状态.实验结果表明罗丹明6G双聚体解聚的某些规律,当单体与双聚体平衡趋于单体时,荧光灵敏度就会增加。  相似文献   

16.
Spectrally dispersed femtosecond time-resolved coherent anti-Stokes Raman spectroscopy is utilized to study the ultrafast vibrational dynamics in rhodamine B dye in solution at room temperature. The anti-Stokes intensities are monitored as a function of time and wavenumber. By simply changing the timing of laser pulses, the vibrational dynamics of excited Raman transitions in rhodamine B molecules can be tracked and detected.  相似文献   

17.
Novel fluorescent materials were satisfactorily synthesized. With this aim, an epoxy resin based on diglycidyl ether of bisphenol A (DGEBA) was reacted with a laser dye, rhodamine B (RB), to achieve an epoxy-based prepolymer. Then, a diamine, m-xylylenediamine (MXDA), was used as hardener with the purpose of obtaining a crosslinked polymer. The curing conditions strongly influence the intended final properties and the optimization of the curing requires a reliable kinetic model. For that reason, this work presents the kinetic study of the polymerization of the epoxy resin by differential scanning calorimetry (DSC) in isothermal mode as well as by Fourier transform infrared spectroscopy (FTIR). DSC data were fitted using a Kamal autocatalytic equation. Conversion as a function of reaction time curves obtained by means of both techniques agreed well. In addition, the synthesized epoxy-based materials were characterized by proton nuclear magnetic resonance spectroscopy (1H NMR) and their fluorescent properties were also analysed.  相似文献   

18.
建立了用1,3-环己二酮-甲醛作为荧光衍生试剂测定氨苄西林钠的方法。氨苄西林钠与1,3-环己二酮-甲醛反应生成一种强荧光物质。其最大激发波长是336 nm,最大发射波长是420 nm。氨苄西林钠浓度在0.01~0.6μg/mL范围内与相对荧光强度呈线性关系,线性方程为ρ=0.0007931F-0.06133,线性相关系数为0.9998,相对标准偏差为1.8%,检出限为10 ng/mL,回收率为97.0%~105.9%。考察了pH、温度、放置时间、干扰离子等对测定的影响。此法可用于注射液中氨苄西林钠的测定。  相似文献   

19.
镁-美他环素胶束体系荧光特性及美他环素的测定   总被引:2,自引:0,他引:2  
研究了在金属离子存在下美他环素在胶柬体系中的荧光特性,实验结果表明:在pH 9.50~11.30的H3PO4-HAc-H3BO3-NaOH缓冲溶液中,镁离子和非离子表面活性剂曲通X-100对美他环素的荧光具有显著的协同增敏作用.据此建立了测定药物制剂中美他环素的荧光光谱法.定量线性范围为0.16~16μg/mL,检出限为0.0036μg/mL,相对标准偏差为1.9%.  相似文献   

20.
Fenoll J  Jourquin G  Kauffmann JM 《Talanta》2002,56(6):1021-1026
A new assay has been developed for measuring residual alkaline phosphatase (ALP) activity in a wide variety of dairy products. The method proposed is simple, rapid and directly applicable to solid and liquid dairy samples. ALP in the test sample hydrolyzes a non fluorescent substrate, trifluoromethyl-β-umbelliferone phosphate, to its highly fluorescent phenolate product. The assay is performed in a reverse micellar medium composed of mixed buffer (2-amino-2-methyl-1-propanol buffer pH 9.0 and borate buffer pH 9.0) in AOT/isooctane, at a temperature of 38 °C. Total test time is 450 s. Reaction rates are linear (except for butter) up to 8.5 and 11% (v/v) raw milk, for whole milk and chocolate milk, respectively. The detection limits are 0.04, 0.4 and 0.22% (v/v) raw milk, for whole milk, chocolate milk and butter, respectively. The precision of the fluorimetric method was assessed by repeated analysis of a pasteurized milk sample spiked with mixed herd raw milk. The accuracy of the method was evaluated by comparison with an official colorimetric assay using p-nitrophenylphosphate as ALP substrate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号