首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel chemiluminescence (CL) flow sensor has been developed for the monitoring of iron(III). The analytical reagents involved in the CL reaction, including luminol and hexacyanoferrate(II) were both immobilized on an anion-exchange resin column. When sodium sulfate solution was passed through the column, these two reagents were eluted from the resins and then mixed with an iron(III) stream. By the fast reaction between iron(III) and hexacyanoferrate(II), the complex Prussian Blue was generated, which could catalyse the luminol oxidation by dissolved oxygen in alkaline aqueous solution to produce CL. The CL emission intensity was correlated with the standard iron(III) concentration in the range 0.01-Smgl–1, and the detection limit was 7 × 10–3mgl–1 iron(III). A complete analysis, including sampling and washing, could be performed in l min with a relative standard deviation of less than 5%. The sensor was stable for over 200 times and has been applied successfully to the determination of iron in blood samples.  相似文献   

2.
Zhang Z  Qin W 《Talanta》1996,43(1):119-124
A novel flow sensor based on chemiluminescence (CL) for the determination of ascorbic acid has been proposed. The analytical reagents, luminol and ferricyanide, were both immobilized on an anion-exchange resin column. The CL signal produced by the reaction between luminol and ferricyanide, which were eluted from the column through sodium phosphate injection, was decreased in the presence of ascorbic acid. The CL emission intensity was linear with ascorbic acid concentration in the range 0.01-0.8 mug ml(-1); the detection limit was 5.5 x 10(-3) mug ml(-1). The whole process, including sampling and washing, could be completed in 1 min with a relative standard deviation of less than 5%. The sensor could be reused more than 100 times and has been applied successfully to the analysis of ascorbic acid in pills and vegetables.  相似文献   

3.
A contact lens (CL) biosensor for in situ monitoring of tear glucose was fabricated and tested. Biocompatible 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer and polydimethyl siloxane (PDMS) were employed as the biosensor material. The biosensor consists of a flexible Pt working electrode and a Ag/AgCl reference/counter electrode, which were formed by micro-electro-mechanical systems (MEMS) technique. The electrode at the sensing region was modified with glucose oxidase (GOD). The CL biosensor showed a good relationship between the output current and glucose concentration in a range of 0.03-5.0 mM, with a correlation coefficient of 0.999. The calibration range covered the reported tear glucose concentrations in normal and diabetic patients. Also, the CL biosensor was applied to a rabbit for the purpose of tear glucose monitoring. The basal tear glucose was estimated to 0.11 mM. Also, the change of tear glucose induced by the change of blood sugar level was assessed by the oral glucose tolerance test. As a result, tear glucose level increased with a delay of 10 min from blood sugar level. The result showed that the CL biosensor is expected to provide further detailed information about the relationship between dynamics of blood glucose and tear glucose.  相似文献   

4.
Song Z  Lü J  Zhao T 《Talanta》2001,53(6):2510-1177
A novel chemiluminescence (CL) sensor for isoniazid combined with flow-injection technology is presented in this paper. The analytical reagents, luminol and ferricyanide, were both immobilized on an anion-exchange column. The CL signal produced by the reaction between luminol and ferricyanide, which were eluted from the column through sodium phosphate injection, was decreased in the presence of isoniazid. The decreased CL intensity was linear with isoniazid concentration in the range 0.001–1.0 μg·ml−1; and the detection limit was 0.35 ng·ml−1 (3s). The whole process, including sampling and washing, could be completed in 2 min with a relative standard deviation of less than 4.1%. The sensor could be reused more than 400 times and has been applied for the determination of isoniazid in pharmaceutical preparations.  相似文献   

5.
A three-layer poly(dimethylsiloxane) (PDMS)/glass microfluidic system for performing on-chip solid-phase enzymatic reaction and chemiluminescence (CL) reaction was used for the determination of glucose as a model analyte. A novel method for the immobilization of controlled-pore-glass based reactive particles on PDMS microreactor beds was developed, producing an on-chip solid-phase reactor that featured large reactive surface and low flow impedance. Efficient mixing of reagent/sample/carrier streams was achieved by incorporating chaotic mixer structures in the microfluidic channels. A conventional sequential injection (SI) system was adapted for direct coupling with the microfluidic system, and combined with hydrostatic delivery of reagents to achieve efficient and reproducible sample introduction at 10 μl levels. A detection limit of 10 μM glucose (3σ), and a precision of 3.1% RSD (n=7, 0.2 mM glucose) were obtained using the SI-microfluidic-CL system integrated with a glucose oxidase (GOD) reactor. Carryover was <5% at a throughput of 20 samples/h.  相似文献   

6.
试剂固定化的流动注射化学发光测定盐酸伊托必利   总被引:2,自引:0,他引:2  
基于盐酸伊托必利在碱性条件下对铁氰化钾鲁米诺化学发光体系有较强的抑制作用,并采用离子交换固定法将鲁米诺和铁氰化钾全部固定在阴离子交换树脂上,联用流动注射技术建立了测定盐酸伊托必利的新方法。本法的线性范围为1.0~100.0μg/mL,检出限0.2μg/mL,对20μg/mL的盐酸伊托必利11次平行测定,其相对标准偏差为2.1%。单次测定在45 s内完成。此固定化柱可使用200次以上。可用于盐酸伊托必利片剂中盐酸伊托必利的质量检测。  相似文献   

7.
Chemiluminescence flow sensor for folic acid with immobilized reagents.   总被引:1,自引:0,他引:1  
A novel chemiluminescence (CL) sensor for folic acid combined flow-injection (FI) technology was presented in this paper. The analytical reagents involved in the CL reaction, including luminol and hexacyanoferrate(III), were both immobilized on an anion-exchange column in FI system. The CL signal produced by the reaction between luminol and hexacyanoferrate(III), which were eluted from the column through sodium phosphate injection, was decreased in the presence of folic acid. The CL emission was correlated with the folic acid concentration in the range from 0.01 to 15 microg ml(-1), and the detection limit was 3.5 ng ml(-1) folic acid (3sigma). At a flow rate of 2.0 ml min(-1), including sampling and washing, could be performed in 2 min with a relative standard deviation of < 2.5%. The flow sensor could be reused more than 300 times and has been applied to the analysis of folic acid in pharmaceutical preparations. and the recovery was from 97.4% to 100.4%.  相似文献   

8.
Lv Y  Zhang Z  Chen F 《The Analyst》2002,127(9):1176-1179
A chemiluminescence biosensor on a chip coupled to a microfluidic system and a microreactor is described in this paper. The chemiluminescence biosensor measured 25 x 75 x 6.5 mm in dimension, and was readily produced in an analytical laboratory. The sol-gel method is introduced to co-immobilize horseradish peroxidase (HRP) and luminol in the microreactor, and to immobilize uricase in the enzymatic reactor. The main characteristic of the biosensor was to introduce air as the carrier flow instead of the more common solution carrier for the first time. The uric acid was determined by a chemiluminescent (CL) reaction between the hydrogen peroxide produced from the enzymatic reactor and luminol under the catalysis of HRP in the microreactor. The linear range of the uric acid concentration was 1 to 100 mg L(-1) and the detection limit was 0.1 mg L(-1) (3sigma).  相似文献   

9.
Bienzymatic biosensor for the determination of glucose by flow injection chemiluminescence (CL) detection was proposed. Hybrids of gold nanoparticles (GNPs) and chitosan were chosen as the immobilization matrix of glucose oxidase (GOD) and horseradish peroxidase (HRP) to fabricate the biosensors with silane-pretreated glass microbeads. After the enzyme catalyzing oxidation of glucose in GOD biosensor, the produced H2O2 flowed into HRP biosensor to react with luminol. The doped GNPs in chitosan were found to enhance the classical CL reaction of luminol-H2O2-HRP. The CL enhancement was investigated in detail by CL and UV-visible spectrum. Under the optimized experimental conditions, glucose could be determined in a linear range from 0.01 to 6.0 mmol/L with a detection limit of 5.0 μmol/L at 3σ. The accuracy of the proposed method was examined by detecting the glucose level in four clinical serum samples from hospital. The proposed method provides a new alternative to determine glucose. Supported by the Natural Science Foundation of Shandong Province (Grant No. Q2007B03), the Doctoral Fund of Qingdao University of Science and Technology (Grant No. 0022141), and the National Natural Science Foundation of China (Grant No. 20775038)  相似文献   

10.
A practical biosensor system has been developed for the determination of urinary glucose using a flow-injection analysis (FIA) amperometric detector and ion-exchange chromatography. Glucose oxidase was immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an immobilized enzyme column. On the basis of its negative charge at pH 5.5, endogenous urate in urine samples was effectively retained by an upstream anion-exchange resin column. The biosensor system possessed a sensitivity of 160 ±2.4 RU μM-1 (RU or relative unit is defined as 2.86 μV at the detection output) for glucose with a minimum detection level of 10 μM. When applied for the determination of urinary glucose, the result obtained compared very well with that of the widely accepted hexokinase assay. The immobilized glucose oxidase could be reused for more than 1000 repeated analyses without losing its original activity. The reuse of the acetate anion-exchange column before replacement would be about 25–30 analyses. Acetaminophen and ascorbic acid were also effectively adsorbed by the acetate anion exchanger. The introduction of this type of anion exchanger thus greatly improved the selectivity of the FIA biosensor system and fostered its applicability for the determination of glucose in urine samples.  相似文献   

11.
A novel analytical procedure based on chemiluminescence (CL) detection was described for the determination of lysozyme at ng ml(-1) level by using controlled-reagent-release technology in a flow injection system. The analytical reagents involved in the CL reaction, including luminol and periodate, were both immobilized on the anion-exchange resins in the flow injection system. Through water injection, luminol and periodate were eluted from the anion-exchange column to generate the chemiluminescence, which was inhibited in the presence of lysozyme. By measuring the decrease of CL intensity, one could analyze the lysozyme quantitatively. The decrement of CL emission was linear over the logarithm of lysozyme concentration in the range of 30-1000 ng ml(-1). A typical analytical procedure, including sampling and washing, could be performed in 0.5 min at a flow rate of 2.0 ml min(-1), giving a throughput of 120 h(-1), with a relative standard deviation of less than 3.0%. The proposed method was applied successfully to the determination of lysozyme in human tear and saliva samples, and the recovery was from 92.0% to 105.7%.  相似文献   

12.
A novel enzyme reactor with co-immobilization of β-galactosidase and glucose oxidase in calcium alginate fiber (CAF) and amine modified nanosized mesoporous silica (AMNMS) was prepared which incorporate the adsorption and catalysis of AMNMS with the cage effect of the polymer to increase catalytic activity and stability of immobilized enzyme. The enzyme reactor was applied to prepare a chemiluminescence (CL) flow-through biosensor for determination of lactose combined with a novel luminol-diperiodatonickelate (DPN) CL system we reported. It shows that the CL flow-through biosensor possesses long lifetime, high stability, high catalytic activity and sensitivity. The relative CL intensity was linear with the lactose concentration in the range of 8 × 10−8-4 × 10−6 g mL−1 with the detection limit of 2.7 × 10−8 g mL−1 (3σ). It has been successfully applied to the determination of lactose in milk.  相似文献   

13.

A rapid and sensitive chemiluminescence flow sensor for the determination of formaldehyde was proposed in this article. The analytical reagents involved in chemiluminescence (CL) reaction, luminol and KIO4, were both immobilized on an anion-exchange column. The CL signal produced by the reaction between luminol and KIO4, which were eluted from the column through water injection, was decreased in the presence of formaldehyde. Formaldehyde was sensed by measuring the decrement of CL intensity, which was observed linear over the logarithm of formaldehyde concentration range of 5.0-1000.0 ng mL?1, and the limit of detection is 1.8 ng mL?1 (3σ). At a flow rate of 2.0 mL min?1, including sampling and washing, could be performed in 0.5 min with a relative standard deviation of less than 3.0%. The flow sensor offered reagentless procedures and remarkable stability in determination of formaldehyde, and could be easily re-used over 80 h. The proposed flow microsensor was applied successfully in the determination of formaldehyde in artificial water samples and air.  相似文献   

14.
Chang G  Tatsu Y  Goto T  Imaishi H  Morigaki K 《Talanta》2010,83(1):61-65
Optical biosensor arrays for rapidly determining the glucose concentrations in a large number of beverage and blood samples were developed by immobilizing glucose oxidase (GOD) on oxygen sensor layer. Glucose oxidase was first encapsulated in silica based gels through sol-gel approach and then immobilized on 96-well microarrays integrated with oxygen sensing film at the bottom. The oxygen sensing film was made of an organically modified silica film (ORMOSIL) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium dichloride (Ru(dpp)3Cl2). The oxidation reaction of glucose by glucose oxidase could be monitored through fluorescence intensity enhancement due to the oxygen consumption in the reaction. The luminescence changing rate evaluated by the dynamic transient method (DTM) was correlated with the glucose concentration with the wide linear range from 0.1 to 5.0 mM (Y = 13.28X − 0.128, R = 0.9968) and low detection limit (0.06 mM). The effects of pH and coexisting ions were systemically studied. The results showed that the optical biosensor arrays worked under a wide range of pH value, and normal interfering species such as Na+, K+, Cl, PO43−, and ascorbic acid did not cause apparent interference on the measurement. The activity of glucose oxidase was mostly retained even after 2-month storage, indicating their long-term stability.  相似文献   

15.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

16.
流动注射化学发光植物组织传感器测定草酸盐   总被引:3,自引:0,他引:3  
草酸是尿道结石主要成因之一 .统计结果表明 ,90 %以上结石均含草酸钙 .回肠病、口角性肠胃炎及脂肪吸收不良均可引起尿液中草酸的增加 .草酸盐的测定在临床上具有重要意义 .微量草酸测定的传统方法是变色酸比色法或偶氮化合物比色法[1 ] .测定草酸盐的方法还有原子吸收光谱法[2 ] 、高效液相色谱法[3] 、离子色谱法[4] 、光度法[5] 和草酸氧化酶法[6] 等 .这些方法或操作复杂、耗时 ,或灵敏度低 ,使其应用受到限制 .本文提出一种测定草酸盐的新方法 ,其原理为草酸 +O2草酸氧化酶 CO2 +H2 O2 ,Luminol+H2 O2 hv  将含有草…  相似文献   

17.
Uricase purified from 20-day-old leaves of cowpea was immobilized on to epoxy resin membrane with 80% retention of initial activity of free enzyme and a conjugation yield of 0.056 mg/cm2. The uricase epoxy resin bioconjugate membrane was mounted over the sensing part of the combined electrode of ‘Aqualytic’ dissolved O2 (DO) meter to construct a uric acid biosensor. The biosensor measures the depletion of dissolved O2 during the oxidation of uric acid by immobilized uricase, which is directly proportional to uric acid concentration. The biosensor showed optimum response within 10-12 s at a pH 8.5 and 35 °C. A linear relationship was found between uric acid concentration from 0.025 to 0.1 mM and O2 (mg/l) consumed. The biosensor was employed for measurement of uric acid in serum. The mean value of uric acid in serum was 4.92 mg/dl in apparently healthy males and 3.11 mg/dl in apparently healthy females. The mean analytic recoveries of added uric acid in reaction mixture (8.9 and 9.8 mg/dl) were 93.6 ± 2.34 and 87.18 ± 3.17% respectively. The within and between batch CVs were <6.5 and <5.0%, respectively. The serum uric acid values obtained by present method and standard enzymic colorimetric method, showed a good correlation (r = 0.996) and regression equation being y = 0.984x + 0.0674. Among the various metabolites tested only, glucose (11%), urea (38%), NaCl (25%) and cholesterol (13%) and ascorbic acid (56%) caused decrease, while, MgSO4 and CaCl2 had no effect on immobilized enzyme. The enzyme electrode showed only 32% decrease during its use for 100 times over a period of 60 days at 4 °C.  相似文献   

18.
A flow-through CL method for the determination of lead combined with controlled-reagent-release technology has been developed. Chemiluminescence (CL) reagents luminol and potassium permanganate were immobilized on anion exchange resin by electrostatic interaction. Lead ion was determined by its enhancing effect on the CL reaction between luminol and potassium permanganate. Both luminol and potassium permanganate were eluted from the anion exchange resin column by sodium phosphate solution. The linear range of the system was 10 μg mL?1, and the detection limit was 5?×?10–9 g mL?1 lead (3σ). A complete analysis could be performed in 1 min with a relative SD 3.2% (1.0?×?10–7 g mL?1, n?=?9). The column shows remarkable stability and can be reused over 350 times and 21 days. The method has been applied to determine lead in human blood samples.  相似文献   

19.
A glucose biosensor based on polyvinylpyrrolidone (PVP) protected Prussian blue nanoparticles (PBNPs)-polyaniline/multi-walled carbon nanotubes hybrid composites was fabricated by electrochemical method. A novel route for PBNPs preparation was applied in the fabrication with the help of PVP, and from scanning electron microscope images, Prussian blue particles on the electrode were found nanoscaled. The biosensor exhibits fast current response (<6 s) and a linearity in the range from 6.7x10(-6) to 1.9x10(-3) M with a high sensitivity of 6.28 microA mM(-1) and a detection limit of 6x10(-7) M (S/N=3) for the detection of glucose. The apparent activation energy of enzyme-catalyzed reaction and the apparent Michaelis-Menten constant are 23.9 kJ mol(-1) and 1.9 mM respectively, which suggests a high affinity of the enzyme-substrate. This easy and controllable construction method of glucose biosensor combines the characteristics of the components of the hybrid composites, which favors the fast and sensitive detection of glucose with improved analytical capabilities. In addition, the biosensor was examined in human serum samples for glucose determination with a recovery between 95.0 and 104.5%.  相似文献   

20.
A novel chemiluminescence (CL) flow sensor for the determination of uric acid in human urine and serum has been developed by using controlled-reagent-release technology. The reagents involved in the chemiluminescence (CL) reaction, luminol and periodate, are immobilized on anion-exchange resin packed in a column. After injection of water, chemiluminescence generated by released luminol and periodate in alkaline media is inhibited in presence of uric acid. By measuring the decreased chemiluminescence (CL) intensity the uric acid is sensed. The decreased response is linear in the 5.0-500.0 ng mL(-1) range, with a detection limit of 1.8 ng mL(-1). The flow sensor showed remarkable operational stability and could be easily reused for over 80 h with sampling frequency of 100 h(-1). The proposed sensor was applied to the determination of uric acid in human urine and serum, and monitoring metabolic uric acid in human urine with RSD less than 3.0%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号