首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with potassium permanganate in a nitric acid medium. A strong chemiluminescence signal was observed when ferulic acid was injected into an acidic potassium permanganate solution in a flow-cell. The present method allowed the determination of ferulic acid in the concentration range of 6.0 x 10(-6) to 2.0 x 10(-4) mol l(-1); the detection limit (3sigma) for ferulic acid was 9.6 x 10(-8) mol l(-1). The relative standard deviation was 1.0% for 11 replicate analyses of 2.0 x 10(-4) mol l(-1) ferulic acid. The proposed method was applied to the determination of ferulic acid in real samples with satisfactory results. Moreover, the reaction mechanism of the chemiluminescence system was primarily considered.  相似文献   

2.
酸性介质下,KMnO4氧化阿魏酸产生化学发光,乙二醛对该体系有增敏作用。结合流动注射技术,建立了测定阿魏酸的流动注射化学发光新方法。该方法线性范围为1.0×10-7~2.0×10-5mol/L,检出限为1.0×10-8mol/L,对1.0×10-6mol/L的阿魏酸平行测定11次,相对标准偏差为2.8%。该法用于太太美容口服液中阿魏酸的测定,结果令人满意。  相似文献   

3.
Flow injection configurations were developed for the individual determination of l-cysteine and l-cystine and for the mixture of both analytes. The method is based on the reaction of l-cysteine with tris(2,2'-bipyridyl) ruthenium (II) and peroxydisulphate under UV irradiation to produce chemiluminescence. Cystine is determined after reduction to cysteine in a copper-coated cadmium reductor mini-column in the flow system. The inclusion of a selection valve in the configuration allows the successive determination of the two analytes. Calibration was linear between 2x10(-6) and 5x10(-4) moll(-1) for cysteine and between 1x10(-6) and 2x10(-4) moll(-1) for cystine. When applied to pharmaceutical formulations, the procedure was free from interferences from common excipients. The results obtained for the assay of commercial formulations compared well with those obtained by an official method and demonstrated good accuracy and precision.  相似文献   

4.
流动注射化学发光抑制法测定抗坏血酸   总被引:22,自引:0,他引:22  
李峰  张文艳  朱果逸 《分析化学》2000,28(12):1523-1526
基于抗坏血酸对Luminol-KIO4-H2O2体系化学发光反应的抑制作用,建立了化学发光抑制快速测定抗坏血酸的新方法。该方法线性范围为1.0*10^-7-1.0*10^-5mol/L,检出限为6.0*10^-8mol/L,对8.0*10^-7mol/L抗坏血酸11次平行测定的相对标准偏差为1.0%。用于维生素C片剂及注射液中抗坏血酸含量的测定,结果令人满意。  相似文献   

5.
Som-aum W  Li H  Liu J  Lin JM 《The Analyst》2008,133(9):1169-1175
A highly sensitive chemiluminescence (CL) method for the determination of arsenate in water based on a simple microfluidic device was developed. The method was based on sorption pre-concentration of arsenate as a form of vanadomolybdoarsenate heteropoly acid (VMoAs-HPA) ion-paired with hexadecyltrimethylammonium bromide on the surface of polystyrene beads packed in a microfluidic device monitored by chemiluminescence detection. The composition of the VMoAs-HPA complex was studied by varying the concentrations of ammonium molybdate, ammonium vanadate and sulfuric acid with a variable-size simplex optimization process, of which the optimum concentrations were 6.3 x 10(-5), 5.0 x 10(-6) and 1.0 x 10(-2) M, respectively. In this work, 1.0 x 10(-3) M ethylenediaminetetraacetic acid was added to all work solutions to remove the interferences of the other metal ions on the CL detection. The integration of sorption pre-concentration not only increased the detection sensitivity but also eliminated the interference from phosphate and chromate. The calibration plot was linear from 1.0 x 10(-7) to 5.0 x 10(-5) M As(v). The limit of detection was 8.9 x 10(-8) M As(v) (S/N = 3). The time required for one analysis run was as short as 5 min. The relative standard deviation was 5.9% (n = 9). This method was successfully applied to the determination of arsenate in mineral-, drinking- and tap-water samples.  相似文献   

6.
A flow-injection analysis (FIA) with a chemiluminescence detection method was developed for the determination of ornidazole based on the inhibition intensity of chemiluminescence from the luminol-ferricyanide system. Under the condition of 1.0 x 10(-3) mol/L luminol and 5.0 x 10(-6) mol/L potassium ferricyanide, the response to the concentration of omidazole is linear from 0.2 microg ml(-1) to 10 microg ml(-1), and a detection limit of 0.05 microg ml(-1) can be obtained. This method has been successfully applied to the determination of omidazole in pharmaceutical preparations.  相似文献   

7.
Ma Q  Ma H  Wang Z  Su M  Xiao H  Liang S 《Talanta》2001,53(5):983-990
7-(4,6-Dichloro-1,3,5-triazinylamino)-4-methylcoumarin (DTMC) was synthesized as a completely new chemiluminescent reagent, and with it a novel chemiluminescence method was developed for the determination of hydrogen peroxide in the absence of any added catalyst or co-oxidant. The chemiluminescence intensity of the DTMC-H(2)O(2) system could be enhanced by the addition of cation surfactants. The chemiluminescence intensity was directly proportional to the concentration of H(2)O(2) in the range 1.0 x 10(-7)-4.0x10(-4) mol l(-1), and the detection limit was 4.0 x 10(-8) mol l(-1). The relative S.D. was 4.9% for 1.0 x 10(-6) mol l(-1) of H(2)O(2) (n=10). The selectivity of this method was high, and most of the transition metal ions have no effect on the determination. The proposed method has been applied to the determination of trace amounts of hydrogen peroxide in snow water. A possible mechanism of the chemiluminescence reaction is also discussed.  相似文献   

8.
Zhike H  Hua G  Liangjie Y  Shaofang L  Hui M  Xiaoyan L  Yun'e Z 《Talanta》1998,47(2):301-304
A chemiluminescence method for the determination of citric acid was developed. The method is based on the enhancement of citric acid on the chemiluminescence light emission of tris-(2,2'-bipyridine)ruthenium(II). In the presence of tris-(2,2'-bipyridine)ruthenium(II), upon the addition of Ce(IV), resulted in intense light emission. The emission intensity is greatly enhanced by the presence of citric acid. The linear range and detection limit of citric acid are 3.0x10(-8) approximately 6.0x10(-6) mol l(-1) and 3.0x10(-8) mol l(-1), respectively. The precision of the proposed method is determined by analyzing 11 samples containing 1.0x10(-7) mol l(-1) citric acid. The relative standard deviation is 3.0%. The enhanced mechanism of citric acid was studied. The method was evaluated by carrying out an interference study with common ions and compounds, by a recovery study and by analysis of human urine and orange juice. A satisfactory result was obtained.  相似文献   

9.
A simple, sensitive and rapid flow-injection chemiluminescence (CL) method has been developed for the determination of cefotaxime sodium based on the chemiluminescence reaction of cefotaxime sodium with ceric sulfate and rhodamine 6G in nitric acid solution. The concentration of cefotaxime sodium was proportional with the CL intensity in the range of 4×10(-8)-8×10(-6) mol L(-1). The detection limit (signal-to-noise ratio=3) was 1×10(-8) mol L(-1). Coupled to the technique of on-line microdialysis sampling, this method was successfully applied to study cefotaxime sodium-protein interaction. The drug and protein were mixed in different molar ratios in Ringer's solution, pH 7.4, and incubated at 37°C in a water bath. The microdialysis probe was utilized to sample the mixed solution at a perfusion rate of 5 μL min(-1) and the recovery of cefotaxime sodium under experimental condition was 16.2%. The data obtained by the present Microdialysis-Flow Injection Analysis-CL method was analyzed with the Scatchard analysis and Klotz plot. The estimated association constant (K) and the number of the binding sites (n) on one of BSA molecule were 5.94×10(4) M(-1) and 1.29 (Klotz equation), respectively.  相似文献   

10.
A novel method based on reversed-phase high-performance liquid chromatography with chemiluminescence detection has been developed for the simultaneous determination of three flavonols including quercetin, kaempferol, and isorhamnetin. The procedure was based on the chemiluminescent enhancement by flavonols of the cerium(IV)-rhodamine 6G system in sulfuric acid medium. The effects of several parameters on the HPLC resolution and CL emission were studied systematically. Good separation was achieved with isocratic elution using a mixture of methanol and aqueous 1.0% acetic acid (37:63, v/v) within 25 min. Under optimized conditions, the linear working range covers 3 orders of magnitude with relative standard deviations below 4.5% for 11 replicate injected flavonol samples, and detection limits (S/N= 3) were 1.6 x 10(-8), 3.5 x 10(-9), and 6.5 x 10(-9) g mL(-1) for quercetin, kaempferol, and isorhamnetin, respectively. The chemiluminescence reaction was compatible with the mobile phase of high-performance liquid chromatography. The proposed method has been successfully applied to the determination of three active flavonols in phytopharmaceuticals of Hippophae rhamnoides L. After a simple extraction procedure, the repeatability and recovery were satisfactory.  相似文献   

11.
基于绿原酸对鲁米诺-H2O2-辣根过氧化物酶化学发光体系具有强烈的抑制作用,建立了绿原酸的化学发光分析法,并探讨了其作用机理。化学发光强度的变化值与绿原酸浓度的对数在5.2×10-9~1.0×10-6g/mL范围内呈线性关系,检出限(S/N=3)达7.8×10-10g/mL。该方法成功用于金银花中绿原酸含量的测定,回收率为96.0%~100.7%。  相似文献   

12.
A novel, rapid and sensitive analytical method is described for determination of ofloxacin and levofloxacin by enhanced chemiluminescence (CL) with flow-injection sampling. The method is based on the CL reaction of the Ce(IV)-Na2S2O4-ofloxacin/levofloxacin-H2SO2 system. The enhanced CL mechanism was developed and the optimum conditions for CL emission were investigated. The CL intensity was correlated linearly (r = 0.9988) with the concentration of ofloxacin (or levofloxacin) in the range of 1.0 x 10(-8) - 1.0 x 10(-7) g ml(-1) and 1.0 x 10(-7) - 6.0 x 10(-6) g ml(-1). The detection limit (S/N = 3) is 7 x 10(-9) g ml(-1). The relative standard derivation (RSD, n = 11) is 2.0% for ofloxacin at 4 x 10(-7) g ml(-1) and for levofloxacin at 6 x 10(-7) g ml(-1). This method has been successfully applied for the determination of ofloxacin and levofloxacin in pharmaceutical preparations and biological fluids with satisfactory results.  相似文献   

13.
A new chemiluminescence system was developed for the determination of cysteine by flow injection system. This method is based on the reaction of L-cysteine with Ru(phen)3(2+) and Ce(IV) to produce chemiluminescence. The calibration curve was linear over the range 8.0x10(-7) to 4.0x10(-5) and 4.0x10(-5) to 1.0x10(-3) M with a detection limit of 7.0x10(-7) M (S/N=3). The relative standard deviation of 4.0x10(-6) M cysteine was found 3.5% (n=10). The influence of potential interfering substances was studied. The proposed method was successfully applied for the flow injection determination of cysteine in the real samples with minimum sampling rate of 90 sample/h.  相似文献   

14.
建立了测定5-磺基水杨酸的流动注射化学发光新方法。 研究了影响化学发光强度的因素,并初步探讨了可能的发光机理。 在最佳化学发光条件下,化学发光强度与5-磺基水杨酸浓度在5.0×10-8~2.0×10-5 mol/L范围内呈良好的线性关系,检出限为1.0×10-8 mol/L,对5.0×10-6 mol/L的5-磺基水杨酸平行测定9次,其相对标准偏差为2.7%。 该法可用于强力霉素废水中5-磺基水杨酸的测定。  相似文献   

15.
Li JJ  Du JX  Lu JR 《Talanta》2002,57(1):53-57
A selective flow injection electrogenerated chemiluminescence(CL) method for the determination of vanadium is described in this paper. It was based on the chemiluminescence reaction of luminol with vanadium(II), which was on-line electrogenerated from vanadate using a flow-through carbon electrolytic cell. Under the optimal conditions, the CL intensity was linear to the concentration of vanadium in the range of 5.0x10(-10)-1.0x10(-7) gml(-1) with a detection limit of 2x10(-10) gml(-1) vanadium. The relative standard deviation was 4% for 5.0x10(-8) gml(-1) vanadium in 11 repeated measurements. The method has been successfully applied to the determination of vanadium in environmental water samples.  相似文献   

16.
Hassouna ME  Elsuccary SA 《Talanta》2002,56(1):193-202
A new kinetic spectrophotometric method for the determination of oxalate has been described, based on its enhancing effect on the oxidation of Mn(II) to MnO(4)(-), which is measured at 525 nm, by potassium periodate. Under the optimum conditions of 20 mugml(-1) Mn(II) in MnSO(4).H(2)O/0.015 moll(-1) H(3)PO(4)/0.013 moll(-1) sodium acetate and 3x10(-3) moll(-1) KIO(4) at 35 degrees C, calibration graphs in the range of 0.05-1.25 and 0.05-1.75 mugml(-1) oxalate concentration were obtained with detection limits of 27 and 5 ngml(-1) by the fixed time and the induction period methods, respectively. No serious interference was identified. The proposed method is simple, inexpensive, sensitive and accurate. The applicability of the method was demonstrated by the determination of the oxalate in spinach and urine samples.  相似文献   

17.
在酸性条件下,KMnO4与甲醛能够产生微弱的化学发光,而富马酸依美斯汀的存在能够大大增强该化学发光强度;结合流动注射技术,建立了测定富马酸依美斯汀的流动注射-化学发光新方法。该方法的线性范围分别为3.0×10-8~2.0×10-7g/mL,2.0×10-7~1.0×10-6g/mL和1.0×10-6~8.0×10-6g/mL。检出限为1.0×10-8g/mL,对2.0×10-6g/mL富马酸依美斯汀滴眼液平行测定11次,其相对标准偏差为1.3%。该方法已成功应用于滴眼液中富马酸依美斯汀的含量测定。  相似文献   

18.
Cu2+ selective PVC membrane electrode based on new Schiff base 2, 2'-[1,9 nonanediyl bis (nitriloethylidyne)]-bis-(1-naphthol) as a selective carrier was constructed. The electrode exhibited a linear potential response within the activity range of 1.0 x 10(-6) - 5.0 x 10(-3) moll(-1) with a Nernstian slope of 29 +/- 1 mV decade(-1) of Cu2+ activity and a limit of detection 8.0 x 10(-7) mol l(-1). The response time of the electrode was fast, 10 s, and stable potentials were obtained within the pH range of 3.5- 6.5. The potentiometric selectivity coefficients were evaluated using two solution method and revealed no important interferences except for Ag+ ion. The proposed electrode was applied as an indicator electrode to potentiometric titration of Cu2+ ions and determination of Cu2+ content in real samples such as black tea leaves and multivitamin capsule.  相似文献   

19.
基于对乙酰氨基酚在酸性介质下对KMnO4-甲醛化学发光体系强烈的增敏作用,建立了对乙酰氨基酚的流动注射化学发光测定方法。在最佳测试条件下,方法对对乙酰氨基酚的检出限(S/N=3)为1.0×10-10mol/L,线性范围为1.0×10-9~1.0×10-5mol/L对乙酰氨基酚,相关系数R为0.9993;对1.0×10-6mol/L的对乙酰氨基酚溶液平行测定11次,其RSD为1.1%。该方法可应用于药物中对乙酰氨基酚含量的测定。  相似文献   

20.
It is found that phenol can react with potassium permanganate in the acidic medium and produce chemiluminescence, which is greatly enhanced by formaldehyde. The optimum conditions for this chemiluminescent reaction are in detail studied using a flow injection system. The experiments indicate that under optimum conditions, the chemiluminescence intensity is linearly related to the concentration of phenol in the range 5.0x10(-9) to 1.0x10(-6)gmL-1 with a detection limit (3sigma) of 3x10(-9)gmL-1. The relative standard deviation is 1.2% for 4.0x10(-7)gmL-1 phenol solution in 11 repeated measurements. This method has the advantages of simple operation, fast response and high sensitivity. The method is successfully applied to the determination of phenol in the waste water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号