首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polycyclic aromatic hydrocarbons (PAHs) are environmental contaminants resulting from emissions of a variety of sources including industrial combustion, discharge of fossil fuels, and residential heating. Because of their mutagenic and carcinogenic properties, the study of PAHs in environmental matrices is of great importance. In this work, the extraction of 9 out of the 16 PAH priority pollutants according to the U.S. Environmental Protection Agency is carried out through liquid-liquid extraction (LLE) and solid-phase extraction (SPE). The determination of PAHs is made by high-performance liquid chromatography with diode-array detection and liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. Between the extraction techniques used, LLE is revealed to be efficient in the extraction of the higher molecular weight PAHs, though SPE is adequate for the extraction of all PAHs. In the real water samples analyzed, no PAH is detected under the analysis conditions used.  相似文献   

2.
Polycyclic aromatic hydrocarbons (PAHs) were determined in marine samples of various types, i.e. seawater, sediment and mussel homogenate samples. The samples were spiked with standard PAH mixtures in both polar (acetonitrile) and non-polar (i-octane) solvents, then extracted. Extraction from seawater was performed by liquid/liquid extraction to hexane (LLE) and with solid phase extraction (SPE) discs. The water samples were filtered and unfiltered seawater, and redistilled water for comparison. The discs with PAHs adsorbed from water samples, and also the sediment and mussel homogenate samples, were extracted with acetonitrile by sonication. PAHs in the disc extracts and from the LLE were cleaned-up using TLC and next determined by GC/MS/IT (with ion-trap) and HPLC-DAD/UV. The analytical procedures were verified with deuterated PAH standard mixtures. The large differences in PAH recoveries (from 12 to 86% for sum, and from 3 to 135% for particular PAHs) do not depend solely on the type of matrix and analytical procedure applied (e.g. standard solvent, volume of evaporated sample), but also on the concentration and molecular structure of the analyte. Usually, only a fraction of each PAH content in the matrix is determined, depending on the particulate matter in seawater and the sorption properties of the solid matrix. The recoveries of deuterated PAHs are higher than those of non-deuterated compounds.  相似文献   

3.
In this work, solid-phase extraction (SPE) trapping performance of lutein and β-carotene, which were used as the model molecules of carotenoids, was investigated. The absorption, elution, and enrichment of carotenoids on SPE cartridges with four different sorbents, i.e. C30, C18, diol, and silica, were compared respectively with the help of frontal analysis technique. The high retentions of both lutein and β-carotene were achieved on the C18 and C30 cartridges. The diol and silica cartridges only had good retention for lutein. The optimized SPE method for sample pretreatment for the carotenoids analysis was obtained after the investigation of trapping performance. The method was applied successfully to the analysis of biological sample, i.e. serum and human breast milk. The recovery, accuracy, and precision of SPE method comparing with those of traditional liquid–liquid extraction (LLE) method for the sample pretreatment for the analysis of carotenoids owned a number of advantages such as rapid, no chloroform used, and accurate versus LLE.  相似文献   

4.
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) from rainwater by solid-phase extraction (SPE) with three different types of cartridge, and analysis by high-performance liquid chromatography with fluorescence detection, are discussed in this paper. Three cartridges were investigated but only one was suitable. After equilibration in a desiccator for 65–80 h or in ambient air for 90–100 h the SPE cartridges were activated with 5 mL dichloromethane then 5 mL 2-propanol. The volume of sample passed through the cartridges was 50 mL; after loading of the sample the cartridges were dried under vacuum for approximately 20 min by application of a pressure of 15 mbar to the SPE manifold. The PAHs were eluted with 5 mL dichloromethane–hexane, 50:50 (v/v). The flow rate used for conditioning, sample loading, and elution was 2.5 mL min−1, achieved by application of a pressure of 6 mbar. For analysis of PAHs in rainwater, recovery was between 67 and 99%, the relative standard deviation varied between 2 and 5%, and the detection limits of the method were less than 16.9 ng L−1 for several PAHs. These optimum conditions were used for analysis of rainwater collected between June 2002 and May 2003 at two sites in Alsace (eastern France) and 17 PAHs were quantitatively determined. Concentrations varied between 1.6 and 968.1 ng L−1.  相似文献   

5.
The article is concerned with the simultaneous determination of simple and macrocyclic trichothecenes using high-performance liquid chromatography (LC) coupled to UV and mass spectrometric (MS) detection. Emphasis is put on the liquid-liquid extraction (LLE) and solid phase extraction (SPE) procedure from plant material such as wheat, comparing SPE cartridges packed with different stationary phases based on silica and polymer sorbents. In this coherence a polymeric material on the basis of poly(glycidyl methacrylate-divinylbenzene) (GMA-DVB) is developed with special regard on synthesis procedures to enhance the extraction recovery of trichothecenes in a broad polarity range. Evaluation of extraction techniques showed that the introduced material is competitive with commercially available high quality SPE materials. Percentage recovery is 82% for polar compounds, 89% for medium polar compounds and 98% for lipophilic compounds.  相似文献   

6.
G H Tan 《The Analyst》1992,117(7):1129-1132
Solid-phase extraction (SPE) of organochlorine pesticide residues from environmental water samples was evaluated using octadecyl (C18)-bonded porous silica. The efficiency of SPE of these pesticide residues from reagent water samples at 1-5 micrograms dm-3 levels was compared with those obtained by solvent extraction with hexane and Freon TF (trichlorotrifluoroethane). Average recoveries exceeding 80% for these organochlorine pesticides were obtained via the SPE method using small cartridges containing 100 mg of 40 microns C18-bonded porous silica. The average recovery by solvent extraction with hexane and Freon TF exceeded 90% in both instances. It was concluded that the recoveries and precision for the SPE of organochlorine pesticides were poorer than those for the solvent extraction method. Organochlorine pesticide residue levels in environmental water samples from two major rivers flowing through predominantly rice-growing areas were monitored by gas chromatography using the solvent extraction method with hexane. Exceptionally high levels of organochlorine pesticide residues such as BHC, DDT, heptachlor, endosulfan and dieldrin were found in these water samples.  相似文献   

7.
A method was developed and validated for the determination of residues of the organophosphorus nematicide fosthiazate in soil and water by using reversed-phase liquid chromatography with UV detection. Good recoveries (>85%) of fosthiazate residues were obtained from water samples (drinking water, groundwater, and liquid chromatography water) after passage of 0.5-2 L water through solid-phase extraction (SPE) C-18 cartridges and subsequent elution with ethyl acetate. Residues in soil were extracted with methanol-water (75 + 25, v/v) on a wrist-action shaker, and the extract was cleaned up on C-18 SPE cartridges before analysis. The method was validated by analysis of a range of soils with different physicochemical characteristics; recoveries exceeded 87% at fortification levels ranging from 0.02 to 5.0 mg/kg. The precision values obtained for the method, expressed as repeatability and reproducibility, were satisfactory (<11%). Fosthiazate detection limits were 0.025 microg/L and 0.005 mg/kg for water and soil samples, respectively. The decline in the levels of fosthiazate residues in soil was measured after application of fosthiazate to protected tomato cultivation. The dissipation of fosthiazate residues followed first-order kinetics with a calculated half-life of 21 days.  相似文献   

8.
This work describes the problems that occur during routine multi-step determinations of polyaromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs), which can be present at trace levels in water, and identifies sources of analyte losses at particular steps during the analytical procedure. PAH and PCB adsorption onto the walls of the container ranged from 0 to 70%. PAH and PCB recoveries of >70% were achieved during the LLE and SPE extraction steps. During the process of enriching the dichloromethane extract with PAHs and PCBs, based on the gentle evaporation of solvent, losses were <24% and <19%, respectively. Model experiments show that neither isolation of PAHs and PCBs (performed using either LLE or SPE) nor extract enrichment reduce the reliability of PAH and PCB determination. The steps that lead to the greatest loss of analyte are the ones that involve sampling, transport and storage of the water samples.  相似文献   

9.
Solid-phase extraction (SPE) and solid-phase microextraction (SPME) were evaluated for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples using gas chromatography coupled to negative chemical ionisation mass spectrometry (GC-NCI-MS). For SPE optimisation, four commercially available SPE cartridges were tested and several SPE parameters, such as the elution solvent, elution volume and breakthrough volume were studied. The best results were obtained with Varian Bond Elut-C18. In order to achieve a high selectivity in the determination of SCCPs, GC-NCI-MS was used. Quality parameters of the optimised SPE and SPME procedures were determined, and the best results were obtained for the SPE/GC-NCI-MS method with LODs of 5 and 20 ng l(-1) for tap and river water, respectively. This method was successfully applied to the analysis of SCCPs in river water samples at concentrations below the microg l(-1) level.  相似文献   

10.
饮用水中9种卤乙酸的超高效液相色谱法测定   总被引:1,自引:0,他引:1  
建立了固相萃取/超高效液相色谱(SPE/UPLC)测定饮用水中9种痕量卤乙酸(HAAs)的分析方法.对固相萃取和液相色谱等分析条件进行了优化,选择Lichrolut EN固相萃取小柱富集饮用水中的HAAs,三乙胺-磷酸缓冲液和甲醇作为UPLC的流动相.在优化的分析条件下,9种卤乙酸在6min内实现基线分离,所有目标物在一定质量浓度范围内线性良好,相关系数为0.995 7~0.9999;一氯乙酸(MCAA)的检出限为10.85μg/L,其它8种化合物的检出限为0.25~0.70μg/L;除MCAA外,其它目标物在低、中、高3种加标水平的回收率为60%~106%.方法的相对标准偏差(RSD,n=5)为2.0%~5.7%.将此方法应用于我国北方某城市自来水中卤乙酸的测定,5种HAAs被检出.方法灵敏度高、简便快捷,可用于生活饮用水中痕量卤乙酸的测定.  相似文献   

11.
Summary Comparative results of pre-treatment methods for the extracts of polycyclic aromatic hydrocarbons (PAHs) from airborne particulate matter for quantitative determination by gas chromatography (GC) are presented. The first method included liquid-liquid extraction and column liquid adsorption chromatography. In the second procedure the extract was fractionated by liquid-liquid chromatography and liquid adsorption chromatography. In the last procedure two different solid phase extraction (SPE) cartridges examined makes it possible to separate PAHs and remove paraffinic compounds which is very important for the quantitative GC analysis of the PAHs. Recoveries of PAH standards and some their derivatives were determined and the contents of 15 of the most important PAHs, were compared. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996  相似文献   

12.
The feasibility of different clean-up procedures was studied for the determination of polycyclic aromatic hydrocarbons (PAHs) in biota samples such as oysters, mussels and fish liver. In this sense, once the samples were extracted--essentially with acetone and in a microwave system--and before they could be analysed by gas chromatography-mass spectrometry (GC-MS), three different approaches were studied for the clean-up step: solid phase extraction (SPE), microwave-assisted saponification (MAS) and gel permeation chromatography (GPC). The main aim of this work was to maximise the recoveries of PAHs and to minimise the presence of interfering compounds in the last extract. In the case of SPE, Florisil cartridges of 1, 2 and 5 g, and silica cartridges of 5 g were studied. In that case, and with oysters and mussels, microwave-assisted extraction and 5 g Florisil cartridges provided good results. In addition, the concentrations obtained for Standard Reference Material (SRM) NIST 2977 (mussel tissue) were in good agreement with the certified values. In the case of microwave-assisted saponification, the extracts were not as clean as those obtained with 5 g Florisil and this fact lead to overestimate the concentration of the heaviest PAHs. Finally, the cleanest extracts were obtained by GPC. The method was successfully applied to mussels, oysters and hake liver, and the results obtained for NIST 2977 (mussel tissue) were within the confidence interval of the certified reference material for most of the certified analytes.  相似文献   

13.
Solid-supported liquid-liquid extraction (SS-LLE) was compared to liquid-liquid extraction (LLE) for the analysis of phenolic compounds in wine. Diatomaceous earth commercial cartridges were evaluated together with "in-house" made cartridges for the wine phenolic extraction. Statistical treatment, analysis of variance ANOVA-single factor, was used to compare the extraction yields obtained by these methods, and for the majority of the studied compounds, significantly higher yields were obtained by the SS-LLE methodology using the "in-house" prepared cartridges. This is an environmentally friendly low-cost sample preparation method which proved to be reproducible (RSD<5% for the most compounds) and yielding high recoveries (80-100%) for the compounds studied.  相似文献   

14.
A disk-type solid-phase extraction (SPE) method was used for the extraction of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in natural water and tap water. Since this SPE system comprised airtight glass covers with a decompression pump, it enabled continuous extraction with semi-automation. The disk-type SPE method was validated by comparing its recovery rates of spiked internal standards with those of the liquid-liquid extraction (LLE). The recovery ranges of both methods were similar in terms of (13)C-labeled internal standards: 64.3-99.2% for the LLE and 52.4-93.6% for the SPE. For the native spike of 1,3,6,8-tetrachlorinated dibenzo-p-dioxin (TCDD) and octachlorinated dibenzo-p-dioxin (OCDD), the recoveries in the SPE were in the normal range of 77.9-101.1%. However, in the LLE, the recoveries of 1,3,6,8-TCDD decreased significantly. One of the reasons for the low recovery is that the solubility of this congener is high. The semi-automated SPE method was applied to the analysis of different types of water: river water, snow, sea water, raw water for drinking purposes, and tap water. PCDD/F congeners were found in some sea water and snow samples, while their concentrations in the other samples were below the limits of detection (LODs). This SPE system is appropriate for the routine analysis of water samples below 50L.  相似文献   

15.
A solid-phase extraction (SPE) method for sample clean-up, followed by reversed-phase high-performance liquid chromatography (HPLC) with fluorescence detection is reported for the determination of polycyclic aromatic hydrocarbons (PAHs) in edible oils. The effects of experimental variables, such as washing and elution solvents, sample solvent and drying time have been studied using C18 cartridges. Recoveries and selectivity using other sorbent materials (C8, C2, CH, PH and NH2) were also examined, with C18 being the best one. The recoveries ranged between 50 and 103% depending on the molecular mass of the PAH. The limits of quantitation were lower than 1 ng/g for most PAHs and good precision was achieved. The method was validated using certified reference materials.  相似文献   

16.
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous compounds that enter the environment from natural and anthropogenic sources, often used as markers to determine the extent, fate, and potential effects on natural resources after a crude oil accidental release. Gas chromatography-mass spectrometry (GC-MS) after liquid–liquid extraction (LLE+GC-MS) has been extensively used to isolate and quantify both parent and alkylated PAHs. However, it requires labor-intensive extraction and cleanup steps and generates large amounts of toxic solvent waste. Therefore, there is a clear need for greener, faster techniques with enough reproducibility and sensitivity to quantify many PAHs in large numbers of water samples in a short period of time. This study combines online solid-phase extraction followed by liquid chromatography (LC) separation with dopant-assisted atmospheric pressure photoionization (APPI) and tandem MS detection, to provide a one-step protocol that detects PAHs at low nanograms per liter with almost no sample preparation and with a significantly lower consumption of toxic halogenated solvents. Water samples were amended with methanol, fortified with isotopically labeled PAHs, and loaded onto an online SPE column, using a large-volume sample loop with an auxiliary LC pump for sample preconcentration and salt removal. The loaded SPE column was connected to an UPLC pump and analytes were backflushed to a Thermo Hypersil Green PAH analytical column where a 20-min gradient separation was performed at a variable flow rate. Detection was performed by a triple-quadrupole MS equipped with a gas-phase dopant delivery system, using 1.50 mL of chlorobenzene dopant per run. In contrast, LLE+GC-MS typically use 150 mL of organic solvents per sample, and methylene chloride is preferred because of its low boiling point. However, this solvent has a higher environmental persistence than chlorobenzene and is considered a carcinogen. The automated system is capable of performing injection, online SPE, inorganic species removal, LC separation, and MS/MS detection in 28 min. Selective reaction monitoring was used to detect 28 parent PAHs and 15 families of alkylated PAHs. The methodology is comparable to traditional GC-MS and was tested with surface seawater, rainwater runoff, and a wastewater treatment plant effluent. Positive detections above reporting limits are described. The virtual absence of sample preparation could be particularly advantageous for real-time monitoring of discharge events that introduce PAHs into environmental compartments, such as accidental releases of petroleum derivates and other human-related events. This work covers optimization of APPI detection and SPE extraction efficiency, a comparison with LLE+GC-MS in terms of sensitivity and chromatographic resolution, and examples of environmental applications.  相似文献   

17.
The coupling of solid-phase extraction (SPE) using bamboo charcoal (BC) as an adsorbent with a monolithic column-high performance liquid chromatography (MC-HPLC) method was developed for the high-efficiency enrichment and rapid determination of 16 polycyclic aromatic hydrocarbons (PAHs) in water. Key influence factors, such as the type and the volume of the elution solvent, and the flow rate and the volume of the sample loading, were optimized to obtain a high SPE recovery and extraction efficiency. BC as an SPE adsorbent presented a high extraction efficiency due to its large specific surface area and high adsorption capacity; MC as an HPLC column accelerated the separation within 8 min because of its high porosity, fast mass transfer, and low-pressure resistance. The calibration curves for the PAHs extracted were linear in the range of 0.2-15 μg/L, with the correlation coefficients (r(2)) between 0.9970-0.9999. This method attained good precisions (relative standard deviation, RSD) from 3.5 to 10.9% for the standard PAHs I aqueous solutions at 5 μg/L; the method recoveries ranged in 52.6-121.6% for real spiked river water samples with 0.4 and 4 μg/L. The limits of detection (LODs, S/N = 3) of the method were determined from 11 and 87 ng/L. The developed method was demonstrated to be applicable for the rapid and sensitive determination of 16 PAHs in real environmental water samples.  相似文献   

18.
建立了气相色谱仪检测水中氟乐灵的方法. 分别采用液液和固相两种萃取浓缩的方式进行样品预处理,两种方法均能满足要求. 液液萃取操作简单,节约时间. 固相萃取能实现自动化处理,节省劳力. 浓缩后使用HP-5色谱柱分离,电子捕获检测器进行测定. 试验结果表明,当水中氟乐灵的质量浓度在0.05~1.0 μg/L范围内,其工作曲线回归方程的相关系数高于0.999,方法检出限(3 S/N)为0.02 μg/L. 在两种不同浓度水平条件下对方法的回收率和精密度进行了试验,其回收率在84.0%~98.0%之间,相对标准偏差在3.0%~5.8%之间.  相似文献   

19.
A quantitative, selective and sensitive HPLC method for the analysis of 14 fungicides in white grapes for vinification is described. The proposed method is based on liquid-liquid extraction (LLE) and solid-phase extraction (SPE) followed by liquid chromatography and diode array detection (HPLC-DAD). Dichloromethane-acetone (75:25, v/v) was the most appropriate solvent mix for extracting fungicides in white grapes. Silica cartridges resulted the most appropriate for extract purification purposes. Quality parameters of the proposed multiresidue method presented good recovery (ca. 85% for almost all target compounds) and precision (between 1.5 and 16%), and detection limits lower than maxima residual limits set by the 76/895/ECC and 90/642/ECC Directive. Five different white grapes for vinification produced in Rias Baixas area in Galicia (NW Spain) were analyzed in order to assess the performance of the method with real samples and to determine whether the concentration of the pesticides used exceed their maxima residue levels (MRLs). Results showed that grape concentrations for those identified fungicides were lower than those established by European legislation.  相似文献   

20.
Analysis of urinary N7-(benzo[a]pyren-6-yl)guanine (BP-6-N7Gua), a DNA adduct induced by benzo[a]pyrene, may serve as a risk-associated biomarker for exposure to polyaromatic hydrocarbons (PAHs). In this study a highly sensitive and specific analytical method, incorporating on-line sample preparation coupled with isotope-dilution liquid chromatography and tandem mass spectrometry (LC/MS/MS), was developed to quantitate this adduct in human urine. In order to achieve accurate quantitation, 15N5-labeled BP-6-N7Gua was synthesized to serve as the internal standard, and a two-step solid-phase extraction (SPE) procedure using C8 and SCX cartridges was used for sample cleanup. BP-6-7-N7Gua was analyzed using positive ion LC/MS/MS operated in multiple reaction monitoring (MRM) mode. The [M+H]+ ions at m/z 402 and 407 and the common fragment ion of [M+H]+ at m/z 252 were monitored for quantification. The recovery of this analyte after two-step SPE was 90%, and the limit of detection was 2.5 fmol/mL in 10 mL of urine. This highly specific and sensitive method for BP-6-N7Gua in urine may be applied to assess exposure to PAHs in coke-oven workers for future molecular epidemiology studies on health effects of PAHs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号