首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and simple high-performance liquid chromatography method with UV detection was developed and validated for determining picroside II in dog plasma. Paeoniflorin was employed as internal standard and the sample pre-treatment procedure consists of deproteinization by addition of acetonitrile. Chromatographic separations were performed on a Shimadzu VP-ODS column (250 x 4.6 mm i.d., 5 microm). The mobile phase consisted of acetonitrile-0.1% acetic acid aqueous (v/v), 23:77, v/v, at a rate of 1 mL/min. Detection was carried out at a wavelength of 266 nm. Calibration standards ranged from 0.25 to 500 microg/mL in dog plasma and the mean correlation coefficient of 0.9981 was found for the linear calibration curves (n = 6). The limit of quantification (LOQ) was 0.25 microg/mL. Intra- and inter-assay RSD ranged from 0.70 to 7.5%. Accuracy (%bias) ranged from -6.3 to 6.0%. This method was applied to the pharmacokinetic study of picroside II in dogs. The study demonstrated the plasma picroside II concentration-time curves were fitted to the two-compartment open model and showed linear pharmacokinetics.  相似文献   

2.
Ferruginol, a diterpene phenol, has recently received attention for its extensive pharmacological properties, including anti‐tumor, antibacterial, cardio‐protective and gastroprotective effects. In the present study, a high‐performance liquid chromatographic (HPLC) method was developed for determination of ferruginol in rat plasma and applied for the pharmacokinetics study. The HPLC assay was performed with a VP ODS‐C18 column. The mobile phaseconsisted of methanol and 1% acetic acid solution (90:10, v/v). The flow rate was 1.0 mL/min, and the wavelength was set at 270 nm. This method was linear over the studied range of 0.1–10.0 µg/mL for ferruginol. The correlation coefficient was 0.9998. The intra‐day and inter‐day precisions were better than 4 and 5%, respectively. The extraction recovery and accuracy were greater than 97 and 96%, respectively. The detection limit was 30 ng/mL. The mean maximum concentration of ferruginol in rat plasma was 3.14 µg/mL at 40 min after oral administration at a dose of 20 mg/kg. Ferruginol was absorbed quickly p.o. with t1/2ka = 14.86 min and had a high rate of elimination with t1/2 = 41.73 min. The pharmacokinetic process of ferruginol in rat was well described with a one‐compartment model. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
Coenzyme Q10 (CoQ10) is a naturally occurring compound located in all membranes throughout the cell. A rapid and sensitive HPLC method was developed to determine the concentration of CoQ10 in dog plasma using a surrogate matrix. Chromatographic separation was carried out on a Diamonsil C18 column with the UV detector set at 275 nm. Methanol–2‐propanol (40:60, v/v) was used as a mobile phase delivered at a flow rate of 1.0 mL/min. Calibrators were prepared using blank plasma–K2HPO4 buffer (50 mm , pH 8.0)–saline (1:3:6, v/v/v) as surrogate matrix. It was shown that the surrogate matrix had similar properties to dog plasma for CoQ10 in extraction, freeze–thaw and stability. The assay was linear over the concentration range of 0.10–100 µg/mL. The intra‐ and inter‐day precisions were within 13.3% in terms of relative standard deviation (RSD%) and the accuracy was within ±7.5% in terms of relative error. This simple and reproducible HPLC method with less plasma volume (0.4 mL) and adequate sensitivity was successfully applied to pharmacokinetic studies of CoQ10 in dogs and an investigation of the effect of CoQ10 formulation on CoQ10 baseline levels. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
Yohimbine is a novel compound for the treatment of erectile dysfunction derived from natural products, and pharmacokinetic study is important for its further development as a new medicine. In this work, we developed a novel PEEK tube‐based solid‐phase microextraction (SPME)–HPLC method for analysis of yohimbine in plasma and further for pharmacokinetic study. Poly (AA‐EGDMA) was synthesized inside a PEEK tube as the sorbent for microextraction of yohimbine, and parameters that could influence extraction efficiency were systematically investigated. Under optimum conditions, the PEEK tube‐based SPME method exhibits excellent enrichment efficiency towards yohimbine. By using berberine as internal standard, an online SPME‐HPLC method was developed for analysis of yohimbine in human plasma sample. The method has wide linear range (2–1000 ng/mL) with an R 2 of 0.9962; the limit of detection was determined and was as low as 0.1 ng/mL using UV detection. Finally, a pharmacokinetic study of yohimbine was carried out by the online SPME‐HPLC method and the results have been compared with those of reported methods.  相似文献   

5.
A simple, sensitive and reproducible high‐performance liquid chromatography (HPLC) assay method was developed for the estimation of 3‐pentylbenzo[c]thiophen‐1(3H)‐one (S5), a potential anti‐ischemic stroke agent, in dog plasma. The analytical procedure involves protein precipitation of S5 and nobiletin (internal standard) from dog plasma with acetonitrile. Chromatographic separation was achieved on Sapphire C18 analytical column with methanol–water (80:20, v/v) as mobile phase. The eluate was monitored using a UV detector set at 260 nm. The calibration curves were linear over the range of 0.2–20 µg/mL. Absolute recoveries of S5 were 79.2–86.1% from dog plasma. The intra‐ and inter‐day relative standard deviation precisions were <7 and 5%, respectively. The method was successfully applied to the pharmacokinetic study of S5 in beagle dogs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
An improved HPLC method was developed for the determination of piperacillin and tazobactam in human plasma and pharmacokinetic study in Chinese healthy volunteers. Piperacillin and tazobactam in human plasma were extracted by solid-phase extraction and separated on a C(18) column and detected at 220 nm. The mobile phase for piepracillin consisted of 0.01 mol/L sodium dihydrogen phosphate (pH = 4.65) and acetonitrile (71:29, v/v), and that for tazobactam was 0.05 mol/L sodium dihydrogen phosphate (pH = 4.45) and methanol (90:10, v/v). The method was linear in the range 0.25-320.00 microg/mL for piperacillin (r(2) = 0.995) and 0.25-64.00 microg/mL for tazobactam (r(2) = 0.994). The lower limit of quantification of both compounds was 0.25 microg/mL. The intra- and inter-day precisions of piperacillin and tazobactam at three concentrations were all less than 9.2% and accuracies were within the range 97.0-108.0%. The method was used to investigate the pharmacokinetics of piperacillin and tazobactam in 12 volunteers who were intravenously given a dosage of 1.25, 2.50 and 3.75 g in three periods. The results showed that piperacillin sodium-tazobactom sodium (4:1) for injection in Chinese people fits linear dynamics, and the administred dosage can be adjusted with therapeutic effect.  相似文献   

7.
A simple, specific and sensitive HPLC method with UV detection was developed and validated for the determination of tectoridin in rat plasma for the first time. Chromatographic separation was performed on a WelchromTM C18 column (150 × 4.6 mm, i.d., 5 µm) at a flow rate of 1.0 mL min?1, using a mixture of methanol–2% HAc aqueous solution (31:69, v/v) as the mobile phase with UV detection at 266 nm. The calibration curves for tectoridin were linear over the concentration range of 1.10–274.40 µg mL?1 in rat plasma. The intra‐ and inter‐day accuracies (RE) were within ?3.23% and 4.11%. The intra‐ and inter‐day precisions (RSD) were not more than 2.74 and 4.72%, respectively. The present method was successfully applied to the pharmacokinetic studies of tectoridin in rats after intravenous administration of three different doses. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Abri Herba and Abri mollis Herba both were important members of the Leguminosae family in southwestern China. Abri mollis Herba was often used as Abri Herba due to their proximity, but there are few studies on pharmacokinetics to compare their main identical active compositions. A sensitive and selective high‐performance liquid chromatography with tandem mass spectrometry method in the positive/negative electrospray ionization switching mode was developed and validated for the simultaneous analysis of four flavonoids and two alkaloids in rat plasma. The chromatographic separation was carried out on a C18 column with a gradient mobile phase consisting of methanol and 0.5% acetic acid. The detection of the target compounds was conducted in multiple‐reaction monitoring mode with a hybrid triple quadrupole linear ion trap mass spectrometer equipped with positive/negative ion‐switching electrospray ion source. The differences in pharmacokinetics were discovered, which indicated that the substitution between them is some degree of irrationality. The validated method was successfully applied to pharmacokinetic study of the six components in male rat plasma after oral administration of Abri Herba and Abri mollis Herba extract and the results in the study would provide a useful guide for the clinical application of Abri Herba with those in Abri mollis Herba.  相似文献   

9.
A rapid, sensitive, precise and specific method for determination of hematoporphyrin monomethyl ether (HMME), a novel photodynamic therapy (PDT) drug, was developed and validated using high-performance liquid chromatography (HPLC) with fluorescence detection. HMME was isolated from the plasma by a single-step liquid-liquid extraction with ethyl acetate. The analyte and internal standard fluorescein were baseline separated on a Diamonsil C(18) analytical column (4.6 x 150 mm, 5 microm) and analyzed using a fluorescence detector with the excitation and emission wavelengths set at 395 and 613 nm, respectively. The method was linear in the concentration range 0.025-5 microg/mL with a lower limit of quantitation (LLOQ) of 10 ng/mL. The inter- and intra-day accuracies and precisions were all within 10% and the mean recoveries of HMME and fluorescein were 95 +/- 3.7 and 90 +/- 2.3%, respectively. The analyte was stable during all sample storage, preparation and analysis periods. This method was successfully applied to a pharmacokinetic study after a single-dose intravenous administration of HMME (5 mg/kg) to beagle dogs. This method was reproducible and sensitive enough for the pharmacokinetic study of HMME. Based on the results of the pharmacokinetic study, we suggest that a rather long light-avoiding time is essential for patients under HMME therapy.  相似文献   

10.
A sensitive high-performance liquid chromatographic method with fluorescence detection (excitation 435 and emission 515 nm) was established and validated for quantification of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) in rat plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (1,8-dihydroxyanthraquinone) were separated on a reversed-phase C(18) column with water-phosphoric acid-methanol as mobile phase at a flow rate of 1 mL/min. The linear ranges of the calibration curves were 6.5-1300 ng/mL for aloe-emodin, 20-4000 ng/mL for rhein, 40-8000 ng/mL for emodin, 15-3000 ng/mL for chrysophanol and 13-2600 ng/mL for physcion. The lower limit of quantification was 6.5 ng/mL for aloe-emodin, 20 ng/mL for rhein, 40 ng/mL for emodin, 15 ng/mL for chrysophanol and 13 ng/mL for physcion. The mean accuracy was 94.3-105.1% for aloe-emodin, 90.3-108.8% for rhein, 92.6-106.7% for emodin, 95.8-103.8% for chrysophanol and 98.7-101.2% for physcion. The within-batch and between-batch precisions were < or = 5.5% and < or = 13.4%, respectively. This method is suitable for determining the five anthraquinones in plasma simultaneously and thus investigating the pharmacokinetics of anthraquinones from Xiexin decoction in rats.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method for determining lehmannine (LMN) in rat plasma was developed for application in the pharmacokinetics study. The plasma was deproteinized with acetonitrile that contained an internal standard and was separated from the aqueous layer by adding sodium chloride. The HPLC assay was carried out using a VP-ODS column at 40 degrees C. The mobile phase was acetonitrile-0.02 mol/L ammonium acetate buffer-triethylamine (35:65:0.04, v/v/v). The flow rate was 1.0 mL/min. The detection wavelength was set at 220 nm. The method was used to determine the concentration-time profiles of LMN in the plasma following oral administration or bolus injection of LMN aqueous solution. The pharmacokinetic parameters of LMN were calculated for the first time by Drug and Statistics 1.0 program.  相似文献   

12.
A sensitive solid-phase extraction/high-performance liquid chromatographic method with ultraviolet detection was established for the analysis of salvianolic acid B in rabbit plasma. The analyte was separated on a reversed-phase column with trifluoroacetic acid-methanol-acetonitrile (70:10:20, v/v/v) as mobile phase at a flow rate of 1 mL/min, and ultraviolet detection at 315 nm. The calibration curve for salvianolic acid B was linear over the range 35-1400 microg/L with coefficients of correlation >0.999. The inter-day and intra-day precisions of analysis were <15%, and assay accuracy ranged from 95.3 to 109.1%. This method is suitable for determining salvianolic acid B in plasma and thus investigating the pharmacokinetics of salvianolic acid B.  相似文献   

13.
建立了茶饮料中六种黄酮类化合物的高效液相色谱检测方法。流动相采用梯度洗脱。结果表明芦丁、漆黄素、木犀草素、芹菜素在0.025~20 mg·L-1范围内呈现良好线性关系,桑色素、槲皮素在0.050~20 mg·L-1范围内呈现良好线性关系。加标回收率在84.5%~107.5%。该方法精密度良好(六种黄酮类化合物的相对标准偏差均不大于3.2%),检测限为6.2~34μg·L-1。该方法简便,灵敏、重现性好,可用于同时分析茶饮料中的黄酮化合物。  相似文献   

14.
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption.  相似文献   

15.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of DRF-4367, a novel cyclooxygenase-2 inhibitor in rat plasma. The assay procedure involved simple liquid/liquid extraction of DRF-4367 and internal standard (IS, celecoxib) from plasma into dichloromethane. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C(18) column (4.6 x 250 mm, 5 microm). The mobile phase consisting of 0.01 M potassium dihydrogen ortho-phosphate (pH 3.2) and acetonitrile (40:60, v/v) was used at a flow rate of 1.0 mL/min. The eluate was monitored using an UV detector set at 247 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of DRF-4367 and IS were 6.6 and 11.2 min, respectively. The standard curve for DRF-4367 was linear (r(2) > 0.999) in the concentration range 0.1-20 micro g/mL. Absolute recovery was >86% from rat plasma for both analyte and IS. The lower limit of quantification of DRF-4367 was 0.1 micro g/mL. The inter- and intra-day precisions in the measurement of quality control samples, 0.1, 0.3, 8.0 and 15.0 microg/mL, were in the range 6.93-9.34% relative standard deviation (RSD) and 0.48-6.59% RSD, respectively. Accuracy in the measurement of QC samples was in the range 91.24-109.36% of the nominal values. Analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. Stability of DRF-4367 was established for 1 month at -80 degrees C. The application of the assay to a pharmacokinetic study in rats is described.  相似文献   

16.
Wu X  Wang R  Xie H  Wang J  Jia Z  Zhang Q  Wang X 《色谱》2011,29(12):1205-1209
建立了快速检测大鼠血浆中普萘洛尔对映体浓度的柱切换-高效液相色谱法。将自制限进填料柱作为预处理柱,通过直接进样方式,使普萘洛尔对映体在预处理柱上保留,同时除去血浆中的蛋白质等大分子;再通过柱切换技术,使普萘洛尔对映体在键合型纤维素-三(3,5-二甲基苯基氨基甲酸酯)(Chiralcel OD-RH)分析柱上得到手性拆分。通过条件优化,确定切换前预处理流动相为硼酸盐缓冲液(pH 8.5)-甲醇(95:5, v/v),流速为1.0 mL/min;切换后分析流动相为异丙醇-乙醇-0.2 mmol/L硼酸盐缓冲液(pH 8.5)(30:30:40, v/v/v),流速为0.8 mL/min;切换时间为3 min;柱温为25 ℃;检测波长为293 nm。普萘洛尔两对映体在25~500 mg/L的质量浓度范围内具有良好的线性关系(r=0.9995), 3个加标水平(50、100、250 mg/L)的平均回收率为97.89%~101.56%,日内和日间精密度均小于5%。该方法简便、快速、灵敏、准确,适于血浆样本中手性药物的药代动力学研究。  相似文献   

17.
A validated reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the determination of bergenin in rat plasma. Bergenin in rat plasma was extracted with methanol, which also acted as a deproteinization agent. Chromatographic separation of bergenin was performed on a C(18) column, with a mobile phase of methanol-water (22:78, v/v) at a flow-rate of 0.8 mL/min and an operating temperature of 40 degrees C, and UV detection was set at 220 nm. The calibration curve was linear over the range 0.25-50 microg/mL (r = 0.9990) in rat plasma. The limit of quantification was 0.25 microg/mL using a plasma sample of 100 microL. The extraction recoveries were 83.40 +/- 6.02, 81.49 +/- 2.40 and 72.51 +/- 2.64% at concentrations of 0.5, 5 and 50 microg/mL, respectively. The intra-day and inter-day precision and accuracy were validated by relative standard deviation (RSD%) and relative error (RE%), which were in the ranges 3.74-9.91 and -1.6-8.0%. After intravenous administration to rats at the dose of 11.25 mg/kg, the plasma concentration-time curve of bergenin was best conformed to a two-compartment open model. The main pharmacokinetic parameters indicated that bergenin exhibited a wide distribution and moderate elimination velocity in rat.  相似文献   

18.
A rapid and sensitive reversed‐phase high‐performance liquid chromatographic (RP‐HPLC) method was developed to investigate pharmacokinetics of columbianadin, one of the main bioactive constituents in the roots of Angelica pubescens f. biserrata, in rat plasma after intravenous administration to rats at two doses of 10 and 20 mg/kg. The method involves a plasma clean‐up step using liquid–liquid extraction by diethyl ether, followed by RP‐HPLC separation and detection. Separation of columbianadin was performed on an analytical Diamonsil? ODS C18 column, with a mobile phase of MeOH–H2O (85 : 15, v/v) at a flow‐rate of 1.0 mL/min, and UV detection was set at 325 nm. The retention time of columbianadin and scoparone (internal standard) was 6.7 and 3.5 min, respectively. The calibration curve was linear over the range of 0.2–20.0 μg/mL (r2 = 0.9986) in rat plasma. The lower limits of detection and quantification were 0.05 and 0.1 μg/mL, respectively. The extraction recovery from plasma was in the range of 81.61–89.93%. The intra‐ and inter‐day precisions (relative standard deviation) were between 1.01 and 9.33%, with accuracies ranging from 89.76 to 109.22%. The results indicated that the method established was suitable for the determination and pharmacokinetic study of columbianadin in rat plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
氧化锆基质HPLC 柱填料研究进展*   总被引:1,自引:0,他引:1  
氧化锆具有很好的化学、机械和热稳定性,适合于碱性物质,特别是生物大分子的分离。氧化锆的色谱性能与硅胶形成很好的互补,具有广阔的应用前景。本文对氧化锆微球表面修饰方法及在色谱分析中的应用进行了综述分析。分析表明氧化锆是性能优异的色谱基质填料。  相似文献   

20.
建立了用高效液相色谱法同时测定白灵菇中3种荧光增白剂(VBL、CBS、CXT)的方法。试样用乙醇-水(V/V=1/2)溶液作提取剂,50℃条件下水浴静置提取15min。采用C18(250mm×4.6mm,2.6μm)为分析柱,以乙酸铵(20mmol/L)+乙腈[65+35]为流动相洗脱,流速为0.8mL/min。3种荧光增白剂在0.01~10μg/mL范围内线性关系良好,相关系数(r2)均大于0.997;加标回收率为79%~90%。方法简单准确,线性关系、重现性及加标回收率均满足分析要求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号