1.
Rodriguez JJ  Ferrera ZS  Perera AA  Diaz VG 《Talanta》1992,39(12):1611-1617
A synchronous spectrofluorometric method was developed for the simultaneous determination of benzo(a)pyrene, perylene and chrysene in a POLE micellar medium, with detection limits of 0.05 ng/ml, 0.28 ng/ml and 0.64 ng/ml, respectively. Good recoveries were obtained for sea water samples spiked with each hydrocarbon.  相似文献   

2.
A method first developed to quantify ochratoxin A in wine has been applied to the analysis of domestic and imported beers in Italy. The method uses commercial immunoaffinity columns for clean-up and high-performance liquid chromatography for quantification of the toxin. Beer was degassed, then diluted with a polyethylene glycol-sodium hydrogencarbonate solution and applied to an OchraTest immunoaffinity column. Ochratoxin A was eluted from the immunoaffinity column with methanol and quantified by reversed-phase HPLC with fluorometric detector. Average recoveries of ochratoxin A from blank beer spiked at levels from 0.04 to 1.0 ng/ml ranged from 93.8% to 100.4%, with relative standard deviations between 3.3% and 5.7%. The detection limit was 0.01 ng/ml based on a signal-to-noise ratio of 3:1. The analysis of 61 samples of domestic (10) and imported (51) beers showed ochratoxin A levels ranging from <0.01 to 0.135 ng/ml with an incidence of contamination of 50% and no substantial difference between strong and pale beers.  相似文献   

3.
A sensitive method has been developed for the detection and quantitative determination of thiodiglycol in blood, plasma and urine. Samples were extracted from Clin Elut columns and cleaned up on C18 Sep-Pak cartridges (blood, plasma) or Florisil Sep-Pak cartridges (urine). Tetradeuterothiodiglycol was added to the sample prior to extraction as internal standard. Thiodiglycol was converted to its bis-(pentafluorobenzoate) derivative and analysed by capillary gas chromatography-electron-capture negative-ion chemical ionisation mass spectrometry using selected ion monitoring. Levels of thiodiglycol down to 1 ng/ml (1 ppb) could be detected in 1-ml spiked blood and urine samples; calibration curves were linear over the range 5- or 10-100 ng/ml. Blood and urine samples from a number of control subjects were analysed for background levels of thiodiglycol. Concentrations up to 16 ng/ml were found in blood, but urine levels were below 1 ng/ml.  相似文献   

4.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B, in a milk powder based infant formula at a possible future European regulatory limit (0.1 ng/g). The test portion was extracted with methanol-water (8 + 2 [v + v]), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. The separation and determination of the aflatoxin B1 was performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) involving bromination. PCD was achieved with either pyridinum hydrobromide perbromide (PBPB) or an electrochemical (Kobra) cell by addition of bromide to the mobile phase. The baby food (infant formula) test samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 14 laboratories in 13 different European countries. Test portions were spiked at levels of 0.1 and 0.2 ng/g for aflatoxin B1. Recoveries ranged from 101 to 92%. Based on results for spiked test samples (blind pairs at 2 levels) and naturally contaminated test samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 3.5 to 14%. The relative standard deviation for reproducibility (RSDR) ranged from 9 to 23%. Nine participants used PBPB derivatization, and  相似文献   

5.
Two flow injection inductively coupled plasma atomic emission spectrometric methods for the preconcentration and determination of trace amounts of cadmium in sea-water and waste-water samples are described based on the adsorption of the metal ion on a micro-column placed in the injection valve of the FI manifold and packed with silica gel funtionalised with 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH-gel) and silica gel functionalised with methylthiosalicylate (TS-gel), respectively. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES are evaluated. The DPTH-gel preconcentration method has a linear calibration range from 5 to at least 100 ng ml(-1) of cadmium, with a R.S.D. of 1.1% for ten independent analyses of 100 ng ml(-1), a detection limit of 1.1 ng ml(-1) and a throughput of 40 samples per hour using a 60 s preconcentration time. The TS-gel preconcentration method shows a linear range between 10 and 100 ng ml(-1), with a R.S.D. of 2.5% for ten independent analyses of 100 ng ml(-1), a detection limit of 4.3 ng ml(-1) and a sample throughput of 24 samples per hour for a preconcentration time of 120 s. Validation was carried out against a certified reference water sample and by determining the analyte content in spiked synthetic sea-water, sea-water and waste-water.  相似文献   

6.
A new and accurate method to quantify ochratoxin A (OA) in table wine has been developed. The method uses commercial immunoaffinity columns for clean-up and high-performance liquid chromatography (HPLC) with fluorescence detection for quantification of the toxin. Wine was diluted with a solution containing 1% polyethylene glycol (PEG 8000) and 5% sodium hydrogencarbonate, filtered and applied to an OchraTest immunoaffinity column. The column was washed with a solution containing sodium chloride (2.5%) and sodium hydrogencarbonate (0.5%) followed by water. OA was eluted with methanol and quantified by reversed-phase HPLC with fluorometric detection (excitation wavelength 333 nm, emission wavelength 460 nm) using acetonitrile-water-acetic acid (99:99:2) as mobile phase. Average recoveries of OA from white, rosé and red wine samples spiked at levels from 0.04 to 10 ng/ml ranged from 88% to 103%, with relative standard deviations (RSDs) between 0.2 and 9.7%. Detection limit was 0.01 ng/ml based on a signal-to-noise ratio of 3:1. The method was applied successfully to 56 samples of red (38), rosé (8), white (9) and dessert (1) wine. The levels of OA ranged from <0.01 to 7.6 ng/ml with red wines more contaminated than rosé and white wines. A good correlation (r=0.987) was found by comparative analysis of 20 naturally contaminated samples using this method and the method of Zimmerli and Dick with better recoveries of OA and better performances for the new method. Several advantages of this method with respect to the actually available methods have been pointed out, with particular reference to red wine which appears to be the most difficult to analyze.  相似文献   

7.
A flow-through/first derivative synchronous spectrofluorimetric sensor for the determination of PAH has been described. This sensor has been used for the simultaneous determination of PAH mixtures (pyrene, benzo(e)pyrene and benzo(ghi)perylene). Linear calibration ranges between 10 and 500 ng/ml with acceptable precision (repeatability, expressed as relative standard deviation, smaller than 4.6%, and sampling frequency of 12 h(-1)) have been obtained. The method has been applied to the determination of the target analytes in spiked water samples with excellent results (recoveries between 94 and 108%).  相似文献   

8.
A flow-through/first derivative synchronous spectrofluorimetric sensor for the determination of PAH has been described. This sensor has been used for the simultaneous determination of PAH mixtures (pyrene, benzo(e)pyrene and benzo(ghi)perylene). Linear calibration ranges between 10 and 500 ng/ml with acceptable precision (repeatability, expressed as relative standard deviation, smaller than 4.6%, and sampling frequency of 12 h–1) have been obtained. The method has been applied to the determination of the target analytes in spiked water samples with excellent results (recoveries between 94 and 108%).  相似文献   

9.
A sensitive fluorescence optosensing method for the determination of Hg(II) in water samples is described. The method, using a flow injection technique, is based on the immobilization on a non-ionic-exchanger solid support (packed in a flow cell placed in a conventional fluorimeter) of the thiochrome formed by the oxidation of thiamine with Hg(II) in a continuous flow carrier at pH 8.1. Experimental parameters such as the solid support, the carrier pH, the thiamine concentration and the flow-rate were investigated to select the optimum operating conditions. The proposed optosensor showed a relative standard deviation of + 3.0% for ten replicates analysis of 100 ng ml(-1) of mercury(II). A detection limit of 3 ng ml(-1) for mercury(II) was achieved for 4-ml sample injections. A detailed study of interferences (possible elements present in natural waters) demonstrated that this optosensing method is virtually specific for this metal, because it allows the determination of mercury in the presence of relatively large amounts of other heavy metals and compounds present in natural waters, such as Mg(II) or Ca(II). The method was successfully applied to the determination of Hg(II) in spiked samples of mineral, tap and sea water.  相似文献   

10.
A method was developed for the confirmed identification and quantitation of 17beta-estradiol, estrone, 17alpha-ethynylestradiol and 16alpha-hydroxy-17beta-estradiol (estriol) in ground water and swine lagoon samples. Centrifuged and filtered samples were extracted using solid-phase extraction (SPE), and extracts were derivatized using pentafluorobenzy] bromide (PFBBR) and N-trimethylsilylimidazole (TMSI). Analysis was done using negative ion chemical ionization (NICI) gas chromatography-mass spectrometry-mass spectrometry (GC-MS-MS). Deuterated analogs of each of the estrogens were used as isotope dilution standards (IDS) and were added to the samples before extraction. A limit of quantitation of 1 ng/l in ground water was obtained using 500 ml of ground water sample, 1.0 ml of extract volume and the lowest calibration standard of 0.5 pg/microl. For a 25 ml swine lagoon sample, the limit of quantitation was 40 ng/l. The average recovery of the four estrogens spiked into 500 ml of distilled water and ground water samples (n = 16) at 2 ng/l was 103% (S.D. 14%). For 25 ml of swine lagoon samples spiked at 500, 1000 and 10,000 ng/l, the average recovery for the four estrogens was 103% (S.D. 15%). The method detection limits (MDLs) of the four estrogens spiked at 2 ng/l in a 500 ml of ground water sample ranged from 0.2 to 0.6 ng/l. In swine lagoon samples from three different types of swine operations, estrone was found at levels up to 25,000 ng/l, followed by estriol and estradiol up to levels at 10,000 and 3000 ng/l, respectively. It was found that pretreatment of swine lagoon samples with formaldehyde was necessary to prevent conversion of estradiol to estrone.  相似文献   

11.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic method for determination of aflatoxin M1 in milk at proposed European regulatory limits. The test portion of liquid milk was centrifuged, filtered, and applied to an immunoaffinity column. The column was washed with water, and aflatoxin was eluted with pure acetonitrile. Aflatoxin M1 was separated by reversed-phase liquid chromatography (LC) with fluorescence detection. Frozen liquid milk samples both naturally contaminated with aflatoxin M1 and blank samples for spiking, were sent to 12 collaborators in 12 different European countries. Test portions of samples were spiked at 0.05 ng aflatoxin M1 per mL. After removal of 2 noncompliant sets of results, the mean recovery of aflatoxin M1 was 74%. Based on results for spiked samples (blind pairs at 1 level) and naturally contaminated samples (blind pairs at 3 levels) the relative standard deviation for repeatability (RSDr) ranged from 8 to 18%. The relative standard deviation for reproducibility (RSDR) ranged from 21 to 31%. The method showed acceptable within- and between-laboratory precision data for liquid milk, as evidenced by HORRAT values at the low level of aflatoxin M1 contamination.  相似文献   

12.
Anti-microcystin LR immunnoaffinity cartridges were evaluated for their ability to selectively remove microcystins from extracts of blue-green algae, fish and water samples for subsequent analysis by liquid chromatography with UV absorbance detection at 238 nm. Blue-green algae and fish samples were extracted with 75% methanol in water. A portion of the extract was diluted and passed through an immunoaffinity cartridge. Water samples were applied directly to the cartridge. The cartridge was rinsed with water and 25% methanol in water. The microcystins were eluted with 80% methanol in water containing 4% acetic acid. It was found that the cartridges were effective in isolating the microcystins from blue-green algae, fish and water samples, resulting in extracts that were clean enough to enable direct LC-UV detection down to approximately 0.03 microg/g in the blue-green algae and fish samples, and as low as 0.02 ng/ml for water samples. The cartridges were found to have a capacity of approximately 200 ng each for a mixture of microcystins RR, YR, LR and LA, or as much as 525-800 ng for individual compounds. Recoveries trough the complete analytical procedure ranged from 64 to 115% (all values) with an overall average of approximately 80% at spiking levels of 0.5-4.0 microg/g for the microcystins in blue-green algae. The average recoveries (n=8) from spiked (0.1-0.5 microg/g) fish samples were 73% for RR, 79% for YR, 81% for LR and 77% for LA, while from the spiked (2.0-0.04 ng/g) tap and river water samples (n=6), recoveries were 78% for RR, 86% for YR, 94% for LR and 89% for LA.  相似文献   

13.
Two different reversed-phase high-performance liquid chromatographic methods for the determination of aniracetam (I) and its metabolite N-anisoyl-GABA (II) in human plasma are described. The procedure for I involves direct injection of plasma samples spiked with the internal standard on a clean-up column followed by reversed-phase chromatography on a C18 column. The limit of quantification was 5 ng/ml, using a 200-microliters specimen of plasma. The mean inter-assay precision of the method up to 800 ng/ml was 3%. The procedure for II involved liquid-liquid extraction of II and the internal standard from plasma with ethyl acetate, and reversed-phase chromatography on a C18 column. The limit of quantification was 50 ng/ml using a 0.5-ml plasma specimen. The mean inter-assay precision up to 50 micrograms/ml was 6%. The applicability and accuracy of the methods were demonstrated by the analysis of over 1000 plasma samples from two bioavailability studies in healthy volunteers.  相似文献   

14.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in cattle feed at a possible future European regulatory limit (1 ng/g). The test portion was extracted with acetone-water (85 + 15), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase liquid chromatography (RP-LC) and detected by fluorescence after post column derivatization (PCD) involving bromination. PCD was achieved with either pyridinium hydrobromide perbromide (PBPB), used by 14 laboratories, or an electrochemical cell and addition of bromide to the mobile phase, used by 7 laboratories. Both derivatization techniques were not significantly different when compared by the t-test; the method was statistically evaluated for all laboratories together (bromination and PBPB). The cattle feed samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 21 laboratories in 14 different countries (United States, Japan, and Europe). Test portions were spiked at levels of 1.2 and 3.6 ng/g for aflatoxin B1. Recoveries ranged from 74 to 157%. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 5.9 to 8.7%. The relative standard deviation for reproducibility (RSDR) ranged from 17.5 to 19.6%. The method showed acceptable within- and between-laboratory precision for this matrix, as evidenced by HORRAT values, at the target levels of determination for aflatoxin B1. No major differences in RSD were observed, showing that the composition of the feeds was not a factor for the samples tested and that the method was applicable for all materials used.  相似文献   

15.
An automated two-dimensional chromatographic method has been developed for the isolation and concentration of recombinant fusion proteins with beta-galactosidase. The system consists of an immunoaffinity column with anti-beta-galactosidase antibodies as ligand, followed by an anion-exchange column. It was used for the purification and concentration of recombinant fusion proteins from Mycobacterium tuberculosis and M. leprae. Small amounts of crude lysates of Escherichia coli were loaded stepwise onto the immunoaffinity column with intermittent washing, elution and re-equilibration. After several cycles the eluate was passed through the anion-exchanger. Using an immunoaffinity gel of 5-ml volume and the anion-exchanger Mono Q HR 5/5, from 10 ml of crude E. coli lysate (containing up to 50 mg of protein) up to 100 micrograms of recombinant protein in a 2-ml volume could be isolated overnight.  相似文献   

16.
A selective and sensitive method for the determination of piritramide in human plasma is described. A 1-ml aliquot of plasma was extracted with 10 ml of hexane-isoamyl alcohol (99.5:0.5, v/v) (extraction efficiency 86%) after addition of 50 microliters of 2 M ammonia and 20 microliters of aqueous strychnine solution (100 ng per 10 microliters) as internal standard. Gas chromatography was performed with J&W DB-1, 30 m x 0.53 mm I.D. separation column, film thickness 1.5 microns, using an nitrogen-phosphorus-sensitive detector. The assay was linear in the concentration range 3.75-2250 ng/ml (r = 0.999), with a lower limit of detection of 1-2 ng/ml. The precision was determined using spiked plasma samples (10 and 50 ng/ml), with coefficients of variation of 3.5 and 3.1% (intra-day; n = 5) and 4.6 and 4.1% (inter-day; n = 4). In the range 3.75-150 ng/ml, the accuracy of the assay was 3.36%. The method was used for the determination of piritramide plasma concentrations in patients receiving intra- or post-operative analgesia.  相似文献   

17.
《Analytical letters》2012,45(13):2217-2230
Abstract

(Acetylacetone)‐2‐thiol‐phenyleneimine (H2L) immobilized on an anion‐exchange resin (Dowex) was used for separation and removal of mercury from natural water samples and for preconcentration prior to its determination by cold vapor inductively coupled plasma atomic emission spectroscopy. The metal was eluted from the column using a solution of 10% thiourea in 0.1 M HCl. The modified resin is higly selective with an exchange capacity of 1.60 mmol g?1. Various parameters like pH, column flow rate, and desorbing agents are optimized. The proposed method has a linear calibration range of 15–1000 ng/ml Hg(II), with a relative standard deviation at the 15 ng/ml level of 3.5%. The precision of the method (evaluated as the relative standard deviation obtained after analyzing six series of five replicates) was ±4.2% at the 50 ng/ml level of Hg(II). The method has been used for routine determination of trace levels of mercury species in natural waters. The potential application of modified resin for the removal of mercury(II) from two natural water samples (top water and lake water) spiked with 50 ng/ml of mercury (II) was studied by ICP‐AES, and the results proved that excellent percent extraction of mercury(II) from both natural water samples was obtained by column method using modified resin.  相似文献   

18.
The use of micellar media in constant-energy synchronous fluorescence spectrometry has been proposed. The influence of some aqueous micellar systems on the determination of pyrene, perylene and benzo[a]pyrene has been investigated. The presence of these micellar systems allows their determination in aqueous media, thus avoiding the use of an organic solvent, and greatly enhances the fluorescence signals. The combination of a constant-energy synchronous scanning technique and a micellar system provided a single spectrum for the simultaneous identification and quantitative determination of the three polycyclic aromatic hydrocarbons (PAHs). Further there was no energy transfer among them, making the measurement simple and fast. A constant-energy difference of 2800 cm(-1) was selected. The analytical characteristics of the proposed method in the presence of anionic micelles of sodium dodecylsulfate (SDS) were studied. The detection limits were at a level of ng ml(-1). Analysis of water samples from two different origins spiked with known amount of pyrene, perylene and benzo[a]pyrene also gave satisfactory results, and total average recoveries were greater than 97.1%.  相似文献   

19.
Stir bar sorptive extraction (SBSE) followed by HPLC-fluorescence detection (FLD) was optimised for analysing 15 polycyclic aromatic hydrocarbons (PAHs) from water samples, especially rainfall water with low PAH content. The literature data described widely different experimental conditions for the extraction of PAHs by SBSE. A chemometric approach was therefore used to evaluate the statistically influential and/or interacting factors, among those described in the literature, and to find the best extraction and desorption conditions. Among six factors studied in a 2(6-2) fractional factorial design, only sample volume, extraction time and the interaction between both of them had significant effects on the PAH extraction recoveries. Optimal sample volume of 10 mL and extraction time of 140 min were obtained with a response surface design. For the desorption conditions, a Box-Behnken design showed that desorption time, temperature and PAH concentrations had significant effects. The best conditions were two successive desorptions with 100 microL of acetonitrile for 25 min at 50 degrees C. The optimised method was repeatable (RSD< or =5.3% for 50 ng L(-1) spiked water and < or =12.8% for 5 ng L(-1) spiked water), linear (R(2)> or =0.9956), with quantitative absolute recoveries (> or =87.8% for 50 ng L(-1) spiked water), and with the LOD between 0.2 and 1.5 ng L(-1). The optimised method was successfully applied to six-rainfall water samples collected in a suburban area. The total PAHs concentrations studied ranged from 31 to 105.1 ng L(-1). Seasonal variation was observed and on average three PAHs were at the highest concentrations (phenanthrene, fluoranthene and pyrene).  相似文献   

20.
《Analytical letters》2012,45(2):243-254
Abstract

An immunoaffinity column (IAC), which can bind diazinon primely, was developed to treat the water and soil samples. The IAC, having an appropriate binding capacity for diazinon (200 ng per mg gel), was prepared by entrapping the anti-diazinon antibody into sol-gel, which was made from hydrolyzed Tetramethoxysilane (TMOS). In comparison with the IACs entrapped with others non-special antibodies, the IAC entrapped with anti-diazinon antibody has a special binding capacity to diazinon. Two different elution modes, 40% and 20% MeCN water solution, were evaluated for desorbing diazinon from the IAC. Efficient desorption of bound diazinon was achieved with the 40% MeCN water elution. The water and soil samples spiked with diazinon were treated by the IAC. The reliable recoveries, which ranged from 50% and 100% with RSD from 4.54% to 16.79%, were achieved.  相似文献   