首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 48 毫秒
1.
During January and February 1996, a significant number of tarball/patty incidents occurred along the coasts of Vancouver Island, Washington, Oregon, and California. Samples of the tarballs were collected from the affected beaches and analyzed by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/flame ionization detector (GC/FID) using a tiered analytical approach developed for determining the origin of oils. Selected samples were further analyzed using a carbon isotopic technique. Also, the relative abundances of a large number of “source-specific marker” compounds, in particular alkylated series of polycyclic aromatic hydrocarbons within the same alkylation isomeric groups, were compared. Results of the analysis revealed that (1) California/Oregon samples were chemically similar and consistent with the same source. They were identified to be bunker type fuel; (2) The tarball samples collected from British Columbia and Ocean Shores, Washington were chemically similar and consistent with the same source (also bunker type fuel). They were found to be similar to but may have a source different than the California/Oregon samples; (3) The source of the tarball/patty samples was neither Alaska North Slope oil nor California Monterrey Miocene oil; (4) The spilled oil samples have been highly weathered since release, and the California samples were more heavily weathered than the British Columbia samples.  相似文献   

2.
Non-degradated mineral-oils like gasoline, solvent naphtha, diesel fuel, fuel and lubricating oils provide a characteristic fingerprint gas chromatogram. This visual classification, e.g. in solid wastes, is complicated due to the simultaneous presence of several mineral-oils. Therefore, a mathematical algorithm for the separation of gas chromatographic fingerprint of “single mixtures” of aliphatic hydrocarbons is developed. The technique ¶is essential for analysis of time-overlapping “single mixtures” of petroleum hydrocarbons (so-called “complex mixtures”) and it relies on the concentration-varying hydrocarbons during evaporation. It is possible to separate the data from the gas chromatogram of a “complex mixture” of hydrocarbons into the chromatograms of the pure “single mixtures” and to give their respective concentrations. A synthetic ?complex mixture” of kerosene, diesel fuel and lubricating oil is used to illustrate the method.  相似文献   

3.
Formal acceptance of the results of chemical laboratories is increasingly organized through a) accreditation of measuring laboratories nationally and b) mutual recognition of accreditation internationally (through formal Multilateral Recognition Agreements, MRAs). However, real comparability of results of measurements is realized by using common (internationally agreed) measurement scales which make these results traceable to this scale, i.e. “traceable” to the same (internationally agreed) value of the unit of that scale. In addition, the criterion against which the evaluation is done, should be “external” to the measurement laboratories which are being evaluated. This is realized in IRMM’s International Measurement Evaluation Programme (IMEP) where evaluation is performed against values which are anchored using “metrology”, the science of measurement with its own rules, which offers a sound foundation for measurement in all scientific disciplines. It is argued in this paper that the demonstration of measurement capability against values on such scales provides a result-oriented rather than a procedure-oriented evaluation. Thus, competence can be “demonstrated” rather than just “designated” and this can be shown to both customers and regulators. It inspires more confidence.  相似文献   

4.
Two batches of a reference material “Creatinine in Human Urine” have been prepared with creatinine concentrations at the physiological level, and used in interlaboratory comparisons in which up to 26 laboratories participated employing up to 4 independent methods. The 95% confidence intervals obtained for the certified creatinine concentrations are better than the “acceptable ranges” of commercially control samples available for clinical laboratories, the certified values being traceable to mean values of the commercial control samples. Thus, a suitable reference material has been prepared for the quality assurance of environmental and occupational health studies in which the concentration of a pollutant or its metabolites in human urine has to be related to the creatinine concentration.  相似文献   

5.
A proficiency testing programme might involve a great number of participating laboratories coming from different countries or regions, and normally they analysed the same test materials using their own routine analytical methods. Hence, the results of a proficiency testing programme may contain valuable information which could serve purposes other than just performance evaluation. This study attempted to extract information from the results of a proficiency testing programme for the purposes of educating the participating laboratories as suggested by ISO/IEC 17043. The “bias analysis” approach introduced in this study was based on the statistical model of measurement and the nature of bias in chemical analysis. With this approach, the participating laboratories could estimate the bias associated with different settings of experimental conditions according to the statistics of subset distribution of the reported results from the participating laboratories. This would be useful for them to review the analytical procedures they used and modify their methods if needed. The approach was applied to the analysis of data obtained from a number of past proficiency testing programmes, and the findings were discussed in this paper.  相似文献   

6.
The implementation of the internal quality assurance program allows for demonstration of the performance characteristics of a method, as well as the avoidance of erroneous results. There is increasing concern in testing laboratories to ensure that the analytical process remains stable, giving reliable results under statistical control. Robustness is tested by introducing variations in experimental conditions and examining the effects on the results. The European document SANCO/12495/2011, “Method validation and quality control procedures for pesticide residue analysis in food and feed”, defines robustness as a parameter that can be derived from ongoing method verification. Internal quality control tools, such as the recovery control chart, were employed in this study to enhance the stability of the recovery rates and to investigate the experimental conditions that have a major influence on the quantification of recovery rates. The method investigated in this study permitted us to investigate eighteen pesticides in olive oil by using a gas chromatography–mass spectrometry technique. This method has been accredited to ISO/IEC 17025:2005 standards and was applied for 1 year in routine conditions for pesticide residues at the Italian National Reference Laboratory. The recovery control chart has showed that all recovery rates for 1 year were close to the maximum limit (120 %) of recovery performance criteria. Consequently, a “positive” bias has affected all data over longer periods of time. A robustness test was planned in order to investigate the grounds that most influenced the variability of the results. The robustness test involved the following three parameters: solvent used to dissolve the final extract, internal standards, and type of olive oil.  相似文献   

7.
A series of dendramines and dendramides have been synthesized and some of their “anti-freeze” properties in diesel fuels have been tested, showing that these compounds are good oil additives for reducing the wax-like crystals which block the fuel filters.  相似文献   

8.
Abstract

Analytical laboratories are looking for the “Total Solution” today. Ideally, the “Total Solution” is the automation of all steps after receiving a sample for analysis including generation of the final report. While that goal is not yet fully realized, efforts to attain it are well underway. Robotic sample preparation systems have rapidly evolved to become common tools in many analytical laboratories which use them along with standard analytical instruments such as chromatographs and spectrophotometers. Physically coupling the two types of systems can offer advantages – the full extent of which depends upon the degree of sophistication in the communication between them. The goal of a “Total Solution” demands real-time decision-making capability based on the information associated with each sample. This information includes everything from its origin to just-completed chromatographic results as the sample travels through the lab. Hence, the level of information exchange between preparation and analysis systems will determine how fully the potential power of such a coupling is utilized.  相似文献   

9.
Gas chromatography with mass spectrometric detection was used to analyze bitumens isolated from bottom sediments of peat lakes contaminated with petroleum products. Endogenous hydrocarbons are characterized by the presence of n-alkanes with an odd number of carbon atoms in the molecule in the characteristic region of C23–C33, the absence of a “hump” characteristic of oil products in the chromatogram, and the presence of light hydrocarbons, eluting in the initial part of the chromatogram (light hydrocarbons are usually lost when the sample is dried). The distribution profile of odd n-alkanes is used to assess the contribution of endogenous hydrocarbons to the “hydrocarbon index” with the help of the pattern recognition method. The concentration of light hydrocarbons is from 50 and 300–400 to 3500–5000 mg/kg for a number of samples and even up to 26000 mg/kg in some samples. The concentration of petroleum hydrocarbons and heteroatomic compounds varies from the lowest values of 30–80 mg/kg up to 20000 mg/kg and higher.  相似文献   

10.
Aging W/O emulsions with various stabilities brake into “rags” – fragments with uneven shapes. Individual “rags” combine into a separate “rag” layer below supernatant oil. In the “rag” material, the continuous oil phase is enriched in heavy constituents, while the disperse phase contains two populations of water drops. Larger drops are formed by mechanical dispersion during emulsification, as indicated by their log-normal number size distributions. Smaller droplets possess exponential number size distributions, indicating a possibility of their spontaneous nucleation. The latter conclusion is supported by microscopic observation of spontaneous appearance of small droplets at a stationary oil–water interface.  相似文献   

11.
In the framework of a collaboration between laboratories involved in bulk U and Pu analysis of environmental samples (DIF centre of the French Commissariat à l’Energie Atomique, US National Laboratories of New Brunswick, Lawrence Livermore, Pacific Northwest, Oak Ridge, and Los Alamos), two round-robins were organised, each one consisting of the complete analysis (chemical preparation and isotope measurement) of three Quality Control samples. The samples were 10 × 10 cm cotton tissues (“swipe samples”) containing low amounts of U (from ~20 to ~150 ng) and Pu (from ~0.15 to ~10 pg). Despite using different spikes, different methods of sample preparation and different analytical instrumentation, the results for U and Pu contents and isotopic compositions reported by all laboratories are globally in good agreement. All laboratories are able to measure sub-pg amounts of U and Pu isotopes with acceptable accuracy and reproducibility, even if limited discrepancies are observed affecting one or other measurement and/or laboratory. General and laboratory specific recommendations were discussed and adopted to continue to improve the accuracy and precision of the measurements.  相似文献   

12.
Standard operating procedures used for the detection of bacteria in environmental samples are primarily based on bacterial growth on specific culture media and confirmation by biochemical and/or immunological tests. In the case of Legionella, isolation on BCYE-?? medium is the standard method, although it presents a number of drawbacks, and for this reason, the implementation of molecular methods, mainly those based on PCR, has increased over the last years. Following the ISO/IEC 17025, laboratories need an external evaluation of their work to assure the quality of the results they are producing, and the participation in proficiency testing (PT) schemes is compulsory. For those water-testing laboratories using PCR methods for Legionella, we have developed a PT scheme accredited according to ISO/IEC 17043. The preparation and the statistical analysis of the results are performed following this standard and the ISO 13528. The used samples have a very rapid and easy to use format, consisting of tablets with inactivated freeze-dried Legionella cells or freeze-dried Legionella DNA. In this PT scheme, participants evaluate both Legionella pneumophila and Legionella spp. detection systems and control the whole PCR process from the water sample concentration until the PCR results.  相似文献   

13.
In this work, we report that 2-cyano-2-phenylpropanoic acid and its p-Cl, p-CH3 and p-OCH3 derivatives can be used as chemical fuels to control the geometry of the calix[4]arene scaffold in its cone conformation. It is shown that, under the action of the fuel, the cone calix[4]arene platform assumes a “locked” shape with two opposite aromatic rings strongly convergent and the other two strongly divergent (“pinched cone” conformation). Only when the fuel is exhausted, the cone calix[4]arene scaffold returns to its resting, “unlocked” shape. Remarkably, the duration of the “locked” state can be controlled at will by varying the fuel structure or amount. A kinetic study of the process shows that the consume of the fuel is catalyzed by the “unlocked” calixarene that behaves as an autocatalyst for its own production. A mechanism is proposed for the reaction of fuel consumption.  相似文献   

14.
ISO Guide 34 and 35 list 4 approaches for the characterization of reference materials. We argue that an approach using “one method of demonstrable accuracy, performed by a network of competent laboratories” will provide method-specific values. Furthermore, as it is impossible to objectively decide whether a method is a reference method or not, the approach using “two or more independent reference methods in one or several laboratories” should be combined with the approach “two or more methods of demonstrable accuracy, performed by a network of competent laboratories.” We therefore propose to replace the four characterization approaches by three in the ongoing revision of ISO Guide 35.  相似文献   

15.
This inter-laboratory comparison study was arranged for 28 laboratories from different public and private sector organizations in Pakistan having wastewater testing capabilities aimed at improving the quality and comparability of test results. This national inter-laboratory study was started in December 2003 and completed in July 2004. Laboratories were invited to analyze the wastewater collected from printed circuit board (PCB) industry for lead and copper contamination. The samples fulfill the criteria for homogeneity and stability as done by the reference laboratory. The results obtained from participating laboratories were analyzed in terms of Hampel Test for outliers, while the performance evaluation of the participating laboratories was done on the basis of Z-score. An assigned value derived from the participant's results was compared with a reference value provided by a reference laboratory. Overall >50% of the participating laboratories have shown good performance in this PT-program  相似文献   

16.
A method for “fingerprinting” crude petroleum to determine the country of origin by thermogravimetry has been developed. Twenty-nine crude oil samples from various sources, both foreign and domestic, have been examined. Comparison of the thermogravimetric data, both graphically and numerically, yield a set of parameters which are useful in distinguishing between crude oil from the Alaskan Prudhoe Bay field and that of fields in other regions of the world.  相似文献   

17.
The usefulness and reliability of the recent BSSE -free SCF algorithm based on the “chemical Hamiltonian approach” (CHA /F ) is demonstrated by calculating potential curves for several hydrogen-bonded complexes with 4-31G , 6-31G , and 6-31G ** basis sets. It is concluded that the CHA /F scheme gives results that are numerically close to those of the Boys–Bernardi a posteriori correction scheme but are free from the “overcompensation” characteristic of the latter at smaller distances and given basis sets. © 1992 John Wiley & Sons, Inc.  相似文献   

18.
Biodiesel is a clean burning fuel derived from a renewable feedstock such as vegetable oil or animal fat. It is biodegradable, non-inflammable, non-toxic, and produces lesser carbon monoxide, sulfur dioxide, and unburned hydrocarbons than petroleum-based fuel. The purpose of the present work is to present an efficient process using reactive distillation columns applied to biodiesel production. Reactive distillation is the simultaneous implementation of reaction and separation within a single unit of column. Nowadays, it is appropriately called “Intensified Process”. This combined operation is especially suited for the chemical reaction limited by equilibrium constraints, since one or more of the products of the reaction are continuously separated from the reactants. This work presents the biodiesel production from soybean oil and bioethanol by reactive distillation. Different variables affect the conventional biodiesel production process such as: catalyst concentration, reaction temperature, level of agitation, ethanol/soybean oil molar ratio, reaction time, and raw material type. In this study, the experimental design was used to optimize the following process variables: the catalyst concentration (from 0.5 wt.% to 1.5 wt.%), the ethanol/soybean oil molar ratio (from 3:1 to 9:1). The reactive column reflux rate was 83 ml/min, and the reaction time was 6 min.  相似文献   

19.
Current technologies have increased the sensitivity for analyzing forensic DNA samples, especially those considered “touch samples.” Because of this, there has been an increase in the number of forensic mixtures–two or more contributors within a single sample–submitted to the crime laboratories. Therefore, the need to resolve these mixtures has increased as well. Several technologies are currently utilized, but many of them are time consuming and do not resolve the entire profile. Therefore, CE‐Single‐Strand Conformational Polymorphisms coupled with the Pluronic F‐108 polymer was assessed for its ability to resolve human forensic mixtures. This technique has been able to detect sequence variation, such as single nucleotide polymorphism in short tandem repeat loci, such as D7S820 and vWA. Samples were first analyzed with the Performance Optimized Polymer‐7, and mixtures created from samples that shared alleles. These samples were sequenced to detect single base‐pair mutations and evaluated with the F‐108 and CE‐Single Strand Conformational Polymorphism analysis. Results from this study indicated the method would serve as a valuable screening tool to detect base sequence variation between individuals when they share alleles in a mixture and before using Massive Parallel Sequencing technology to distinguish which bases differ.  相似文献   

20.
The analysis of chloroform vapor sorption at 35°C in semicrystalline syndiotactic polystyrene samples shows remarkably different sorption isotherms, depending on the crystalline form of the samples. In particular, “emptied” clathrate (“emptied” δ form) samples are characterized by higher equilibrium sorption levels and the differences are particularly relevant for low vapor activities. Moreover, sorption kinetics detected at a vapor activity equal to 0.5 show that in the case of “emptied” δ form samples the sorption rate is much higher than for the other semicrystalline samples. The larger sorption equilibrium uptakes and sorption rates of the “emptied” δ form samples are essentially due to their ability to absorb chloroform, already for low activities, by clathration in the crystalline phase. The measured equilibrium uptakes and sorption kinetics suggest that “emptied” δ form samples of syndiotactic polystyrene could be suitable for removing polluting chlorinated compounds from vapor and liquid streams. © 1997 John Wiley & Sons, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号