首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Absorber is an important component in vapor absorption refrigeration system and its performance has greater influence in overall efficiency of absorption machines. Falling film heat and mass transfer in an absorber is greatly influenced by fluid properties, geometry of heat exchanger and its operating parameters. This paper presents on the results of experimental studies on the heat and mass transfer characteristics of a coiled tube falling film absorber, using 1,1,1,2-Tetrafluroethane(R-134a) and N-N Dimethyl Acetamide (DMAC) as working fluids. The effects of film Reynolds number, inlet solution temperature and cooling water temperature on absorber heat load, over all heat transfer coefficient and mass of refrigerant absorbed are presented and discussed. Normalized solution and coolant temperature profiles and refrigerant mass absorbed along the height of absorber are also observed from the experimental results. The optimum over all heat transfer coefficient for R-134a–DMAC solution found to be 726 W/m2K for a film Reynolds number of 350. The R-134a vapour absorption rate is maximum in the normalized coil height of 0.6 to 1.  相似文献   

2.
The heat transfer characteristics of supercritical fluids in tubes have been considered indispensable for the design and optimization of the heat exchanger and the energy conversion system. Specifically the cooling heat transfer of supercritical R1234ze(E) in horizontal tubes is a promising heat-power conversion technology; however, there is a scarcity of conducted research in available literature. The present work, the first-ever study in this direction, aims to thoroughly investigate the heat transfer characteristics of supercritical R1234ze(E) which is cooled in horizontal tubes. Experimental work was performed to thoroughly explore and inspect the heat transfer characteristics of supercritical R1234ze(E) passing through the tube of 4.12 mm diameter at 4–5 MPa pressure and 240–400 kg/m2 s mass flux. Furthermore, the simulation study, supporting the experimental investigation under the same conditions of pressure and mass flux, extended the range of tube diameter up to 9.44 mm. The effects of pressure, mass flux and tube diameter on the heat transfer coefficient were carefully analyzed in the present research work. Based on the simulation results and experimental results, heat transfer correlations were newly developed by separating the region above and below the pseudo-critical temperature. The average absolute deviation between the calculated Nusselt numbers by the numerical correlation and the simulation results was found 2.87%; the average absolute deviation between the calculated Nusselt numbers by the experimental correlation and the experimental results was found 5.3%.  相似文献   

3.
The performance of heat pipe solar collector is investigated theoretically and experimentally. The system employs wick-assisted heat pipe for the heat transfer from the absorber (evaporator) to a heat exchanger (condenser). The heat pipe is made with a copper tube and the evaporator section is finned with aluminium plate. Theoretical model predicts the outlet water from heat exchanger, heat pipe temperature and also the thermal efficiency of solar collector. The results are compared with experimental data.  相似文献   

4.
In this paper the heat and mass transfer characteristics of a horizontal tube absorber for the mixture R134a/DMAC in terms of experimentally gained heat and mass transfer coefficients are presented. The heat transfer coefficient is mainly dependent on the solution’s mass flow rate. The mass transfer coefficient is strongly related to the subcooling of the solution. The data are compared to experimental absorption characteristics of water into aqueous lithium bromide in an absorption chiller. The mass transfer coefficients are of similar size whereas the heat transfer coefficients are about one order of magnitude smaller for R134a-DMAC.  相似文献   

5.
The condensation heat transfer of pure refrigerants, R-22, R-134a and a binary refrigerant R-410A flowing in small diameter tubes was investigated experimentally. The condenser is a countflow heat exchanger which refrigerant flows in the inner tube and cooling water flows in the annulus. The heat exchanger is smooth, horizontal copper tube of 1.77, 3.36 and 5.35 mm inner diameter, respectively. The length of heat exchanger is 1220, 2660 and 3620 mm, respectively. The experiments were conducted at mass flux of 200–400 kg/m2 s and saturation temperature of 40°C. The main results were summarized as follows: in case of single-phase flow, the single-phase Nusselt Number measured by experimental data was higher than that calculated by Gnielinski and Wu and Little correlation. The new single-phase correlation based on the experimental data was proposed in this study. In case of two-phase flow, the condensation heat transfer coefficient of R-410A for three tubes was slightly higher than that of R-22 and R-134a at the given mass flux. The condensation heat transfer coefficient of R-22 showed almost a similar value to that of R-134a. The condensation heat transfer coefficient for R-22, R-134a and R-410A increased with increasing mass flux and decreasing tube diameter. Most of the existing correlations which were proposed in the large diameter tube failed to predict condensation heat transfer. Therefore, the new condensation heat transfer correlation based on the experimental data was proposed in the present study.  相似文献   

6.
The condensation heat transfer characteristics for CO2 flowing in a horizontal microfin tube were investigated by experiment with respect to condensation temperature and mass flux. The test section consists of a 2,400?mm long horizontal copper tube of 4.6?mm inner diameter. The experiments were conducted at refrigerant mass flux of 400–800?kg/m2s, and saturation temperature of 20–30?°C. The main experimental results showed that annular flow was highly dominated the majority of condensation flow in the horizontal microfin tube. The condensation heat transfer coefficient increases with decreasing saturation temperature and increasing mass flux. The experimental data were compared against previous heat transfer correlations. Most correlations failed to predict the experimental data. However, the correlation by Cavallini et al. showed relatively good agreement with experimental data in the microfin tube. Therefore, a new condensation heat transfer correlation is proposed with mean and average deviations of 3.14 and ?7.6?%, respectively.  相似文献   

7.
For one horizontal tube in an absorber the Nusselt solution for film thickness and velocity distribution was applied, assuming steady state in heat transfer and a semi-infinite body’s concentration profile with unsteady state mass transfer. The model was applied to the absorption of steam into aqueous lithium bromide in absorption chillers. The results are compared to published experimental values and show fair agreement.  相似文献   

8.
Experimental results for heat transfer characteristic and pressure gradients of hydrocarbon (HC) refrigerants and R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have one tube diameter of 12.70 mm with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local condensing heat transfer coefficients of HC refrigerants were higher than that of R-22. The average condensing heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in HC refrigerants than R-22. Comparing the heat transfer coefficient of experimental results with that of other correlations, the presented results had a good agreement with most of the Cavallini’s correlations.  相似文献   

9.
The condensation heat transfer coefficients of R-22, R-134a and R-410A in a single circular microtube were investigated experimentally. The experiments are conducted without oil in the refrigerant loop. The test section is a smooth, horizontal copper tube of 1.77 mm inner diameter. The experiments were conducted at mass flux of 450-1050 kg/m2 s, saturation temperature of 40 °C. The test results showed that in case of single-phase flow, the single-phase Nusselt Number measured by experimental data was higher than that calculated by Gnielinski correlation. In case of two-phase flow, the condensation heat transfer coefficient of R-410A was higher than that of R-22 and R-134a at the given mass flux. The condensation heat transfer coefficient of R-22 showed almost a similar value to that of R-134a. Most of the existing correlations which were proposed in the large diameter tube failed to predict condensing heat transfer. And also, recently proposed correlation in the single circular microtube is considered not adequate for small diameter tube. Therefore, it is necessary to develop accurate and reliable correlation to predict heat transfer characteristics in the single circular microtube.  相似文献   

10.
This article reports an experimental investigation on flow boiling heat transfer and pressure drop of refrigerant R-134a in a smooth horizontal and two microfinned tubes from different manufacturers with the same geometric characteristics. Experiments have been carried out in an experimental facility developed for change of phase studies with a test section made with 9.52 mm external diameter, 1.5 m long copper tubes, electrically heated by tape resistors wrapped on the external surface. Tests have been performed under the following conditions: inlet saturation temperature of 5 °C, vapor qualities from 5% to 90%, mass velocity from 100 to 500 kg/s m2, and a heat flux of 5 kW/m2. Experimental results indicated that the heat transfer performance was basically the same for both microfin tubes. The pressure drop is higher in the microfinned tubes in comparison to the smooth tube over the whole range of mass velocities and vapor qualities. The enhancement factor, used to evaluate the combination of heat transfer and pressure drop, is higher than one for both tubes for mass velocities lower than 300 kg/s m2. Values lower than one have been obtained for both tubes in the mass velocity upper range as a result of a significant pressure drop increment not followed by a correspondent increment in the heat transfer coefficient. Some images, illustrating the flow patterns, were obtained from the visualization section, located in the exit of the test section with the same internal diameter of the tested tube.  相似文献   

11.
A model was developed to determine the performance of the counter and parallel flow absorbers using water-lithium bromide solution. The simulation method of heat and mass transfer in the coil absorber is explained and a computer program was generated and applied. The effects of the main parameters on the absorber performance were determined and the results were presented in graphical form. It has been proved that the model explained in this study is capable of predicting an estimated wetted area and can approximate heat transfer coefficients and so can predict the absorber performance.  相似文献   

12.
In this study, effect of electrohydrodynamic (EHD) on the condensation heat transfer enhancement and pressure drop of pure R-134a are experimentally investigated. The test section is a 2.5 m long counterflow double tube heat exchanger with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is made from smooth horizontal copper tubing of 9.52 mm outer diameter. The electrode is made from stainless steel wire of 1.47 mm diameter. The test runs are performed at average saturated temperatures ranging between 40 and 60°C, mass flux ranging between 200 and 600 kg/m2 s, heat flux ranging between 10 and 20 kW/m2 and applied voltage at 2.5 kV. For the presence of the electrode, the experimental results indicate that the maximum heat transfer enhancement ratio is around 30% while the maximum increase in pressure drop is about 25%.  相似文献   

13.
A new absorber configuration has been proposed for parabolic trough solar collector. It consists of a tube through which the working fluid flows. The tube is attached externally to two longitudinal fins which are directed normally to the collector aperture. The absorber aggregate, tube and fins, is encased by a transparent envelope. The heat balance equations for such absorber have been derived and solved. Based on these analyses a study has been carried out on an absorber located in Alexandria (31o N latitude) in Egypt to show the effect of its geometrical parameters on the thermal performance. The results of the study show that a wide range of concentration ratios, higher than the smallest ideal ones, can be chosen. For each concentration ratio, there is a corresponding fin height to absorber tube diameter ratio which maximizes the collector efficiency. The greatest collector efficiency is achieved when the concentration ratio is 1.7 of the smallest ideal one and the ratio of fin height to tube diameter in 0.7. In this case the collector efficiency increases in average ca. 3% over that when using a conventional absorber.  相似文献   

14.
Water wall design is a key issue for supercritical Circulating Fluidized Bed (CFB) boiler. On account of the good heat transfer performance, rifled tube is applied in the water wall design of a 600 MW supercritical CFB boiler in China. In order to investigate the heat transfer and frictional characteristics of the rifled tube with vertical upward flow, an in-depth experiment was conducted in the range of pressure from 12 to 30 MPa, mass flux from 230 to 1200 kg/(m2 s), and inner wall heat flux from 130 to 720 kW/m2. The wall temperature distribution and pressure drop in the rifled tube were obtained in the experiment. The normal, enhanced and deteriorated heat transfer characteristics were also captured. In this paper, the effects of pressure, inner wall heat flux and mass flux on heat transfer characteristics are analyzed, the heat transfer mechanism and the frictional resistance performance are discussed, and the corresponding empirical correlations are presented. The experimental results show that the rifled tube can effectively prevent the occurrence of Departure from Nucleate Boiling (DNB) and keep the tube wall temperature in a permissible range under the operating condition of supercritical CFB boiler.  相似文献   

15.
A mathematical model based on the annular flow pattern is developed to simulate the evaporation of refrigerants flowing under varied heat flux in a double tube evaporator. The finite difference form of governing equations of this present model is derived from the conservation of mass, energy and momentum. The experimental set-up is designed and constructed to provide the experimental data for verifying the simulation results. The test section is a 2.5 m long counterflow double tube heat exchanger with a refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tube is made from smooth horizontal copper tubing of 9.53 mm outer diameter and 7.1 mm inner diameter. The agreement of the model with the experimental data is satisfactory. The present model can be used to investigate the axial distributions of the temperature, heat transfer coefficient and pressure drop of various refrigerants. Moreover, the evaporation rate or the other relevant parameters that is difficult to measure in the experiment are predicted and presented here. The results from the present mathematical model show that the saturation pressure and temperature of refrigerant decrease along the tube due to the tube wall friction and the flow acceleration of refrigerant. The liquid heat transfer coefficient increases with the axial length due to reducing the thickness of the liquid refrigerant film. Due to increase of the liquid heat transfer coefficient, increasing wall heat flux is obtained.Finally, the evaporation rate of refrigerant increases with increasing wall heat flux.  相似文献   

16.
A spiral wire was used to augment the heat transfer inside the tubes of surface condensers or shell-and-tube heat exchangers. A spiral wire with a reinforcing component in the direction of the spiral axis has been investigated as a fouling cleaner on the internal surface of a tube, when it is driven in a reciprocating motion with the help of reinforcing wires. When it stays in the tube, it augments the convective heat transfer. Based on the an experimental investigation, the relationships among the heat transfer, drag, cleaning effectiveness, fouling rates, and geometric variables of the cleaner-augmenter performance were found. The results of the experimental investigations on the cleaner-augmenter and the comprehensive evaluation criterion for the device as a fouling cleaner are presented along with the dimensions of tube diameter, wire diameter, and pitch.  相似文献   

17.
An analysis has been provided for the entropy generated for the micro/nano scale heat and mass transfer in a capillary tube in terms of the gradients of velocity, temperature and concentration as well as the physical properties of the fluid. The heat and mass transfer rates are assumed to be uniform on the surface of the capillary tube. The optimum tube diameter that corresponds to the minimization of entropy generated and minimization of fluid flow resistance is about 1 mm. We have applied the method of thermodynamic optimization to capillary driven systems. The objective was to identify the geometric configuration that maximized performance by minimizing the entropy generated when the flow rate is prescribed.  相似文献   

18.
This study intended to verify the cooling heat transfer characteristics of supercritical gas for refrigerating and air-conditioning devices that use CO2, a natural refrigerant, as the operating fluid. Experiments were performed with a gas cooler, which was the test part. The gas cooler was a heat exchanger made of a micro-fin tube with an inner diameter of 4.6 mm and an outer diameter of 5.0 mm. The experiment results are summarized as follows. The heat transfer coefficient, according to the mass flux, peaked at the low cooling pressure of 8.0 MPa in the gas cooler, and reached its minimum at the high pressure of 10.0 MPa. Furthermore, when the mass flux of the refrigerant increased, the coefficient increased faster with the lower cooling pressure in the gas cooler. The heat transfer coefficient, according to the shape of the heat transfer tube, showed that the maximum values of the CO2 cooling heat transfer coefficients of the smooth tube and the micro-fin tube were found at 44.7 °C, which were the pseudo-critical temperatures for the entrance pressures. It was found that the cooling heat transfer coefficient of the micro-fin tube increased by 12–39 % more than that of the smooth tube. The experiment results for the CO2 heat transfer coefficients of the smooth tube and the micro-fin tube were compared with the results estimated from previous correlations. It was found that the experiment values generally significantly differed from and the experiment values greater than the estimated values. The differences were especially greater in the vicinity of the critical temperature points. Based on these results, a new correlation was suggested that includes the density ratio and the specific heat ratio.  相似文献   

19.
Experimental measurements of heat transfer by free convection in a cylindrical waterfilled enclosure from a horizontal finned tube of small fin height is reported. The measured heat transfers are presented in form of correlation equationsNu=f(Ra). The Rayleigh numbers have been alternatively defined with the annulus height, core diameter and an equivalent diameter defined for the finned tube. The correlation equations have been formulated for heat transfer (i) in an infinite medium and (ii) in an annulus. Results show that for the experimental annulus gap/enclosure diameter ratio of 24.66 and 40.74, the heat transfer analysis based on infinite medium assumption shows a somewhat better correlation although the influence of the enclosure cannot be completely neglected. Defining the Rayleigh number with an equivalent diameter makes it possible to compare the experimental measurements with those from a smooth tube.  相似文献   

20.
The flow patterns and heat transfer coefficients of R-22 and R-134a during evaporation in small diameter tubes were investigated experimentally. The evaporation flow patterns of R-22 and R-134a were observed in Pyrex sight glass tubes with 2 and 8 mm diameter tube, and heat transfer coefficients were measured in smooth and horizontal copper tubes with 1.77, 3.36 and 5.35 mm diameter tube, respectively. In the flow patterns during evaporation process, the annular flows in 2 mm glass tube occurred at a relatively lower vapor quality compared to 8 mm glass tube. The flow patterns in 2 mm glass tube did not agree with the Mandhane’s flow pattern maps. The evaporation heat transfer coefficients in the small diameter tubes (d i  < 6 mm) were observed to be strongly affected by tube diameters, and to differ from those in the large diameter tubes. The heat transfer coefficients of 1.77 mm tube were higher than those of 3.36 mm and 5.35 mm tube. Most of the existing correlations failed to predict the evaporation heat transfer coefficient in small diameter tubes. Therefore, based on the experimental data, the new correlation is proposed to predict the evaporation heat transfer coefficients of R-22 and R-134a in small diameter tubes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号