首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
The electrochemical behavior of bisphenol A (BPA) was studied on poly(3,4-ethylenedioxythiophene) (PEDOT)-modified glassy carbon electrodes by cyclic voltammetry. It was observed that BPA oxidation on PEDOT film produced a BPA polymer (pBPA) showing excellent redox activity with anodic and cathodic peaks at 0.15 and 0.01 V, respectively; the former being evaluated for BPA electrochemical sensing. The amount of deposited pBPA has been estimated by electrochemical and spectroscopic analysis by X-ray photoelectron spectroscopy. The effect of scan rate and pH on the oxidation of pBPA film has been studied. The oxidation current was found to vary linearly with BPA concentration in the range 90–410 μM, and a detection limit of 55 μM was evaluated. Results of BPA amperometric detection have also been collected by using a repetitive potential step program to give a linear response to BPA in the concentration range 40–410 μM with a detection limit of 22 μM and a sensitivity of 1.57 μAμM?1?cm?2. The developed sensor showed satisfactory reproducibility and anti-interference properties and was successfully applied to BPA determination in mineral water samples.  相似文献   

2.
This work describes the modification of a glassy carbon electrode with poly(Toluidine Blue O) (GC/poly-TBO) and single-walled carbon nanotubes (SWCNT) for the electrocatalytic oxidation of nitrite. GC/poly-TBO was prepared by electropolymerization and used as such or after immobilizing SWCNT on the polymeric film to give a composite GC/poly-TBO-SWCNT electrode. The electrochemical and catalytic behavior of both electrodes was studied comparatively. It was observed that the presence of SWCNT contributed to enhance the electrocatalytic response for nitrite oxidation, as measured by amperometry at +0.92 V vs. Ag/AgCl/KClsat and pH 7. The response was linear with respect to the nitrite concentration in the 0.001–4 mM range, with a detection limit of 0.37 μM (based on signal to noise ratio of 3) for GC/poly-TBO-SWCNT. The proposed method was also applied to the determination of nitrite in a wastewater sample and compared to the spectrophotometric method.  相似文献   

3.
A sensitive electroanalytical method for the determination of anticancer drug etoposide (ETP) using adsorptive stripping differential pulse voltammetry (AdSDPV) at a multi-walled carbon nanotube-modified glassy carbon electrode (MWCNT-modified GCE) is presented. The surface morphology of modified electrode was characterized by scanning electron microscopy. The effects of accumulation time and potential, pH, scan rate, and amount of MWCNT suspension were investigated. The calibration curve was linear in the concentration range of 2.0?×?10?8–2.0?×?10?6 M with the detection limit of 5.4?×?10?9 M. The reproducibility of the peak current was found at 1.55 % (n?=?5) RSD value in pH 6.0 Britton–Robinson buffer for the MWCNT-modified GCE. The method was then successfully utilized for the determination of ETP in pharmaceutical dosage form, and a recovery of 99.55 % was obtained. The possible oxidation mechanism of ETP was also discussed. The proposed electroanalytical method using MWCNT-modified GCE is the most sensitive method for the determination of ETP with lowest limit of detection in the previously published electrochemical methods.  相似文献   

4.
A graphitized mesoporous carbon modified glassy carbon electrode (GCE/GMC) prepared by drop coating method without any pre-anodization of the underlying GCE or external binder/matrix, has been demonstrated for simultaneous electrochemical oxidation of guanine (G) and adenine (A) at oxidation potentials 0.60 and 0.85 V vs. Ag/AgCl, respectively, in the presence of thymine (T) by differential pulse voltammetric method in pH 7 phosphate buffer solution. Control voltammetric experiments with unmodified GCE, graphite nanopowder and multiwalled carbon nanotube modified electrodes yielded either feeble or with high-background current responses. Interestingly, the GCE/GMC showed highly efficient, stable and well-defined voltammetric signals. Thymine oxidation signal noticed discretely at 1.15 V vs. Ag/AgCl on the GCE/GMC was not influenced for the simultaneous determination of G and A. Constructed DPV calibration graphs were linear in the range of 25–200 and 25–150 μM, respectively, for the G and A. Corresponding detection limit (S/N?=?3) values are 0.76 and 0.63 μM. Real sample analyses for the detection of G and A concentrations in calf-thymus DNA (detected [G]/[A] ratio?=?0.82), beef brain and beef liver were successfully demonstrated with recovery values ~100 %.  相似文献   

5.
Electrocatalytic oxidation of NADH at mesoporous carbon modified electrodes   总被引:1,自引:0,他引:1  
The electrochemical oxidation of β-nicotinamine adenine dinucleotide (NADH) was investigated at a glassy carbon electrode modified with carbon mesoporous materials (CMM). Due to the large surface area and electro-catalytic properties of CMM, the overpotential of the electrodes toward the oxidation of NADH is decreased by 595 mV in aqueous solution at neutral pH. The anodic peak currents increase steadily with the concentration of NADH in the range from 2 µM to 1.1 mM, the detection limit being 1.0 µM at pH 7.2 and a potential of +0.3 V vs. SCE. The apparent Michaelis-Menten constant is ~21.5 μM. The results enable NADH to be sensed at a low potential and are promising with respect to the design of dehydrogenase-based amperometric biosensors.  相似文献   

6.
A novel method has been developed for determination of nitrite by modifying the surface of a glassy carbon electrode (GCE) using single-walled carbon nanotubes with covalently immobilized single-strand deoxyribonucleic acid. The modified electrodes were characterized by field emission scanning electron microscopy, X-ray photoelectron spectroscopy, and electrochemical techniques. The results demonstrate that the nanotube-DNA nanocomposite has been successfully immobilized on the surface of the GCE. The new electrode, under optimum conditions at room temperature, exhibits excellent electrocatalytic activity towards the oxidation of nitrite, with a significantly reduction of the overpotential. The linear range for the detection of nitrite is from 0.6 to 540 μM, with a sensitivity of 0.216 μA?μM?1, and a detection limit as low as 0.15 μM. The electrode showed good reproducibility and high stability and was successfully used to analyze nitrite in water and sausage samples.  相似文献   

7.
We report on a sensitive electrochemical sensor for dopamine (DA) based on a glassy carbon electrode that was modified with a nanocomposite containing electrochemically reduced graphene oxide (RGO) and palladium nanoparticles (Pd-NPs). The composite was characterized by scanning electron microscopy, energy dispersive spectroscopy, and electrochemical impendence spectroscopy. The electrode can oxidize DA at lower potential (234 mV vs Ag/AgCl) than electrodes modified with RGO or Pd-NPs only. The response of the sensor to DA is linear in the 1–150 μM concentration range, and the detection limit is 0.233 μM. The sensor was applied to the determination of DA in commercial DA injection solutions.
Figure
Schematic representation showing the oxidation of DA at RGO-Pd-NPs composite electrode.  相似文献   

8.
Chunya Li 《Mikrochimica acta》2007,157(1-2):21-26
Multi-wall carbon nanotubes (MWNT) were dispersed into water in the presence of dicetyl phosphate (DCP), and MWNT-DCP composite film coated glassy carbon electrodes (GCE) were constructed. The electrochemical properties of 2-chlorophenol at a bare GCE and MWNT-DCP modified GCE were compared. It was found that MWNT-DCP modified GCEs significantly enhance the oxidation peak current of 2-chlorophenol and lowers its oxidation overpotential, suggesting great potential in the sensitive determination of 2-chlorophenol. Finally, a sensitive and simple voltammetric method was developed for the determination of 2-chlorophenol. The oxidation peak current increases linearly with the concentration in the range of 1.0 × 10−7–2.0 × 10−5 mol L−1, and the detection limit is 4.0 × 10−8 mol L−1 for 2 min accumulation. The method was successfully used to determine 2-chlorophenol in waste water samples.  相似文献   

9.
A carbon paste electrode based on γ-cyclodextrin–carbon nanotube composite (γ-CD–CNT–CME) was developed for the determination of propranolol hydrochloride (PRO). The electrochemical behaviour of PRO was investigated employing cyclic voltammetry, electrochemical impedance spectroscopy and differential pulse adsorptive stripping voltammetry (DPAdSV). Surface morphology of the electrode has been studied by means of scanning electron microscopy. The results revealed that the oxidation of PRO is facilitated at γ-CD–CNT–CME. Under the optimized conditions in Britton–Robinson buffer pH 1.5, the peak currents were found to vary linearly with their concentrations in the range of 1.42 × 10?7 to 4.76 × 10?5 M. A detection limit (S/N = 3) of 4.01 × 10?8 M was obtained for PRO by means of DPAdSV. The proposed method was employed for the determination of PRO in pharmaceutical formulations, urine and blood serum samples.  相似文献   

10.
Graphene nanosheets were directly electrodeposited onto a glassy carbon electrode (GCE) from the electrolyte solution containing graphene oxide (GO); the resulting electrode (ED-GO/GCE) was characterized with scanning electron microscopy. A simple and rapid electrochemical method was developed for the determination of theophylline (TP), based on the excellent properties of ED-GO film. The result indicated that ED-GO film-modified GCE exhibited efficient electrocatalytic oxidation for TP with relatively high sensitivity and stability. The electrochemical behavior of TP at ED-GO/GCE was investigated in detail. Under the optimized conditions, the oxidation peak current was proportional to the TP concentration in the range of 8.0?×?10?7 to 6.0?×?10?5 mol?L?1 with the detection limit of 1.0?×?10?7 mol?L?1 (S/N?=?3). The proposed method was successfully applied to green tea samples with satisfactory results.  相似文献   

11.
We report on a glassy carbon electrode that was modified with a composite made from graphene oxide (GO) and multiwalled carbon nanotubes (MWCNT) that enables highly sensitive determination of L-tyrosine. The sensor was characterized by transmission electron microscopy and electrochemical impedance spectroscopy, and its electrochemical properties by cyclic voltammetry, chronocoulometry and differential pulse voltammetry. The GO/MWCNT hybrid exhibits strong catalytic activity toward the oxidation of L-tyrosine, with a well defined oxidation peak at 761 mV. The respective current serves as the analytical information and is proportional to the L-tyrosine concentration in two ranges of different slope (0.05 to 1.0 μM and 1.0 to 650.0 μM), with limits of detection and quantification as low as 4.4 nM and 14.7 nM, respectively. The method was successfully applied to the analysis of L-tyrosine in human body fluids. The excellent reproducibility, stability, sensitivity and selectivity are believed to be due to the combination of the electrocatalytic properties of both GO and MWCNT. They are making this hybrid electrode a potentially useful electrochemical sensing platform for bioanalysis.
Figure
A new L-tyrosine electrochemical sensor was fabricated based on graphene oxide and multiwalled carbon nanotube. The prepared sensor exhibits excellent electro-catalysis to the oxidation of L-tyrosine, and can improve determination sensitivity and decrease detection limit. This sensor was successfully applied to detect L-tyrosine in human fluids with satisfactory results.  相似文献   

12.
New voltammetric sensors based on glassy carbon electrodes (GCEs) modified by poly(arylene phthalide) are studied. The electrochemical behavior of bisoprolol on GCEs modified by poly(arylene phthalide) is investigated. The effects of potential scan rate, time of accumulation on the electrode, pH of supporting electrolyte, and concentration on the current of bisoprolol electrooxidation are estimated. A procedure is developed for the voltammetric determination of bisoprolol on glassy carbon electrodes modified by poly(arylene phthalide). The dependence of the analytical signal on the concentration of bisoprolol is linear in the range 10–6–10–5 M with the limit of detection (3.4–9.8) × 10–8 M.  相似文献   

13.
Carbon-supported palladium nanostructures have had a recent rise in their use for ethanol oxidation applications. In this work, we present the use of unsupported palladium nanoparticles (PdNPs), synthesized by sodium borohydride chemical reduction method, for ethanol electrochemical sensing. The unsupported PdNPs were studied for ethanol oxidation in alkaline media by cyclic voltammetry, and additionally were characterized using transmission electron microscopy, and x-ray photoelectron spectroscopy. The performance of unsupported PdNP-modified glassy carbon electrodes for the electrochemical ethanol oxidation in 1.0 M potassium hydroxide (KOH) solution was studied by cyclic voltammetry. These electrochemical results demonstrated that the unsupported PdNPs have very promising catalytic activity towards the oxidation of ethanol in alkaline media with good detection performance in the concentration range of 2304 to 288 ppm (i.e., 50.00 to 6.25 mM). The detection limit and linear correlation coefficient were 49.3 ppm (1.10 mM) and 0.9998, respectively. The unsupported PdNP-modified glassy carbon electrodes presented good cyclic voltammetric stability for ethanol sensing application in alkaline media.  相似文献   

14.
A new composite electrode of multiwall carbon nanotubes (MWNTs) and 1-dodecyl-3-methylimidazolium hexafluorophosphate (DDMIMPF6) was fabricated to determine rutin. This electrode showed very attractive electrochemical performances compared to other kinds of ionic liquid modified electrodes and notably improved sensitivity and stability. Electrochemical behavior of rutin at the composite electrode had been investigated in pH 2.09 Britton–Robinson buffer solution by cyclic voltammetry and square wave voltammetry. The experimental results suggested that the composite electrode exhibited an electrocatalytic activity toward the redox of rutin. The electrochemical parameters of rutin were calculated with the results of the charge transfer coefficient (α) and the standard rate constant (k s) as 0.48 and 2.09 s?1. Under the selected conditions, the reduction peak current was linearly dependent on the concentration of rutin in the range of 0.03–1.5 μM, with a detection limit of 0.01 μM (S/N?=?3). The relative standard deviation for six times successive determination of 1 μM rutin was 1.6 %. The method was successfully applied to the determination of rutin in tablets and urine samples without the influence of the coexisting substances. In addition, the MWNTs/DDMIMPF6 composite electrode exhibits a distinct advantage of simple preparation, surface renewal, good reproducibility, and stability.  相似文献   

15.
In this study, a glassy carbon electrode modified with different cobalt glucosamines (CoGlu-R), iron glucosamines (FeGlu-R), and nickel glucosamines (NiGlu-R) was used for the electroanalytical determination of melatonin in buffer solutions at pH 7.3 using cyclic and square wave voltammetry. The complexes were synthesized and characterized by IR-TF, 1H-NMR, and UV–visible spectroscopy. When comparing glucosamines of different metals, the influence of the nature of the metal on the activity is not very strong. The most active complex was CoGlu-R. The oxidation peak was used to determine melatonin in the concentration range of 10?8–10?5 M with a detection limit of 2.15?×?10?7 M (LOD). Our results indicate that the current peak is under mass-transport control and probably suggest that chemical reactions coupled with electrochemical steps are involved. The melatonin oxidation current with this kind of modified electrodes is small but this modified electrode shows high selectivity in medium-199 (glutamine, phenol red, glucose, Na+, CO3 2?) with human placental tissue; trophoblast and endothelial cells (K+, Ca2+, traces of Cu2+ and Mg2+), yet the tryptophan causes interference.  相似文献   

16.
Oxine (8-hydroxyquinoline) was used as an efficient and selective ligand for stripping voltammetry trace determination of Mn(II). A validated square-wave adsorptive cathodic stripping voltammetry method has been developed for determination of Mn(II) selectively as oxine complex using both the bare carbon paste electrode (CPE) and the modified CPE with 7 % (w/w) montmorillonite-Na clay. Modification of carbon paste with montmorillonite clay was found to greatly enhance its adsorption capacity. Limits of detection of 45 ng l?1 (8.19?×?10?10 mol L?1) and 1.8 ng l?1 (3.28?×?10?11 mol L?1) Mn(II) were achieved using the bare and modified CP electrodes, respectively. The achieved limits of detection of Mn(II) as oxine complex using the modified CPE are much sensitive than the detection limits obtained by most of the reported electrochemical methods. The developed stripping voltammetry method using both electrodes was successfully applied for trace determination of Mn(II) in various water samples without interferences from various organic and inorganic species.  相似文献   

17.
Nickel–salophen-modified glassy carbon electrodes prepared by transferring one drop of Ni–salophen complex solution on the electrode surface. This modified electrode has been used for the electrocatalytic oxidation of methanol in alkaline solutions with various methods such as cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy. The electrooxidation was observed as large anodic peaks, and early stages of the cathodic direction of potential sweep around 20 mV vs. Ag|AgCl|KClsat. A mechanism based on the electrochemical generation of Ni (Ш) active sites and their subsequent consumptions by methanol have been discussed. EIS studies were employed to unveil the charge transfer rate as well as the electrical characteristics of the catalytic surface. For the electrochemical oxidation of methanol at 5.0 M concentration, charge transfer resistance of nearly 0.936 kΩ was obtained, while the resistance of the electrocatalyst layer was about 111.6 Ω.  相似文献   

18.
Multi-walled carbon nanotubes (MWNTs) modified glassy carbon electrode (GCE) was simply and conveniently fabricated. The electrochemical properties of paracetamol (PCT) at the prepared modified electrode were investigated by cyclic voltammetry (CV). Based on this, an ultrasensitive and rapid electrochemical method was developed for the determination of PCT. The result indicated that the oxidation of PCT was greatly improved at the MWNTs-modified GC (MWNTs/GC) electrode as compared with the bare GC electrode, with relatively high sensitivity, stability and life time. Good linear relationship between the oxidation peak current and the PCT concentration in the range of 1 × 10−7 to 1 × 10−3 M (r = 0.996) was obtained in phosphate buffer solution (PBS) with pH 6.5, the detection limit was 2 × 10−8 M (S/N = 3) by use of modified electrode. The proposed method was successfully applied to the PCT determination in tablets.  相似文献   

19.
The electrochemical oxidation of sulfite catalyzed by acetylferrocene (AFc) at a glassy carbon electrode (GCE) in 0.2 M NaClO4 aqueous solution has been studied by cyclic voltammetry. Although sulfite itself showed a sluggish electrochemical response at the GCE, the response could be enhanced greatly by using AFc as a mediator, which enables a sensitive determination of the substrate (sulfite). The reaction rate constant for catalytic oxidation was evaluated as (7.02 ± 0.05) × 104 M ?1 s?1 by chronoamperometry. Experimental conditions that maximize the current efficiency of the electrocatalytic oxidation, such as the pH and both the catalyst (AFc) and substrate (sulfite) concentrations, were also investigated. The electrochemical kinetics of electrocatalytic oxidation of sulfite by AFc has been studied by cyclic voltammetry. In the presence of 5 × 10?4 M AFc, the oxidation current is proportional to the sulfite concentration and the calibration plot was linear over the concentration range 2 × 10?4–2.4 × 10?3 M . This result can be applied in the determination of real samples. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

20.
The electrochemical oxidation of morphine (MO) and codeine (COD) has been investigated by the application of a novel glassy carbon electrode modified with a hydroxyapatite-Fe3O4 nanoparticles/multiwalled carbon nanotubes composite (HA-FeNPs-MWCNTs/GCE). The modified electrode worked as an efficient sensor for simultaneous determination of MO and COD in the presence of uric acid. Response surface methodology was utilized to optimize the voltammetric response of the modified electrode for the determination of MO and COD. The amount of HA-FeNPs in the modifier matrix (%HA-FeNPs), the solution pH and the accumulation time were chosen as the three important operating factors through the experimental design methodology. The central composite design as a response surface approach was applied for obtaining the optimum conditions leading to maximum oxidation peak currents for MO and COD. The differential pulse voltammetry results showed that the obtained anodic peak currents were linearly proportional to concentration in the range of 0.08–32 µM with a detection limit (S/N = 3.0) of 14 nM for MO and in the range of 0.1–28 µM and with a detection limit of 22 nM for COD. The proposed method was successfully applied to determine these compounds in human urine and blood serum samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号