首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel mesoporous‐coated stainless steel wire microextraction coupled with the HPLC procedure for quantification of four polycyclic aromatic hydrocarbons in water has been developed, based on the sorption of target analytes on a selectively adsorptive fiber and subsequent desorption of analytes directly into HPLC. Phenyl‐functionalized mesoporous materials (Ph‐SBA‐15) were synthesized and coated on the surfaces of a stainless steel wire. Due to the high porosity and large surface area of the Ph‐SBA‐15, high extraction efficiency is expected. The influence of various parameters on polycyclic aromatic hydrocarbons extraction efficiency were thoroughly studied and optimized (such as the extraction temperature, the extraction time, the desorption time, the stirring rate and the ionic strength of samples). The results showed that each compound for the analysis of real water samples was tested under optimal conditions with the linearity ranging from 1.02×10?3 to 200 μg/ L and the detection limits were found from 0.32 to 2.44 ng/ L, respectively. The RSD of the new method was smaller than 4.10%.  相似文献   

2.
In this work, an isotope dilution method for determination of selected acidic herbicides by high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS) was developed for surface water samples. Average percent recoveries of native analytes were observed to be between 70.8 and 93.5% and average recoveries of labeled quantification standards [(13)C(6)]2,4-D and [(13)C(6)]2,4,5-T were 85.5 and 101%, respectively. Using this method, detection limits of 0.05 ng/L for dicamba, MCPA, MCPP, and triclopyr, and 0.5 ng/L for 2,4-D were routinely achieved. The method was applied to measuring the concentration of these analytes in surface water samples collected from five sampling locations in the Lower Fraser Valley region of British Columbia, Canada. All of the herbicides monitored were detected at varying levels in the surface water samples collected. The highest concentrations detected for each analyte were 345 ng/L for 2,4-D, 317 ng/L for MCPA, 271 ng/L for MCPP, 15.7 ng/L for dicamba, and 2.18 ng/L for triclopyr. Average detection frequencies of the herbicides were 95% for MCPA, 80% for MCPP, 70% for dicamba, 65% for 2,4-D, and 46% for triclopyr. Seasonal variations of herbicide levels are also discussed.  相似文献   

3.
Docetaxel is an antineoplastic agent widely used in therapeutics. The objective of this study was to develop and validate a routine assay, using liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS), for the simultaneous quantification of docetaxel and its main hydroxylated metabolites in human plasma. A structural analogue, paclitaxel, was used as the internal standard. Determination of docetaxel and four metabolites (M1, M2, M3 and M4) was achieved using only 100 microL of plasma. Liquid-liquid extraction was used for sample preparation, with extraction efficiency of at least 90% for all analytes. Detection used positive-mode electrospray ionization in selected reaction monitoring mode. The lower limit of quantification (LLOQ) was 0.5 ng/mL for all analytes. The assay was linear in the calibration curve range 0.5-1000 ng/mL and acceptable precision and accuracy (<15%) were obtained with concentrations above the LLOQ. This method was sufficiently selective and sensitive for quantification of metabolites in plasma from cancer patients receiving docetaxel chemotherapy, and is suitable for routine analyses during pharmacokinetic studies.  相似文献   

4.
Trifloxystrobin (TFS) is a widely used strobilurin fungicide and its residues accumulating in animal-derived food could result in potential harm to consumers. By optimization of extraction solvents and cleanup sorbents, a residue analysis method for TFS and its metabolite trifloxystrobin acid (TFSA) was established in milk, eggs and pork based on QuEChERS sample preparation and LC–MS/MS. The calibration curves exhibited good linearity with determination coefficients (R2) >0.9930 over the range of 0.5–250 ng/ml for both TFS and TFSA. The recoveries of the two analytes were 81–100% with RSD 3–10% and 76–96% with RSD 2–13%, respectively. The limit of quantification (LOQ) was 1 ng/g for both analytes. The milk, egg and pork samples, 30 each, were collected from the 30 main producing regions in China, and residues of TFS and TFSA were analyzed. The concentrations of both analytes were lower than the corresponding LOQs and maximum residue limits. Long-term dietary risk assessment showed that the hazard quotients were 0.001–0.003%, indicating an absence of unacceptable risks in milk, eggs and pork to the health of common consumers in China.  相似文献   

5.
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of rimonabant in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 463-363 for rimonabant and m/z 408-235 for the internal standard. The assay exhibited a linear dynamic range of 0.1-100 ng/mL for rimonabant in human plasma. The lower limit of quantification was 0.1 ng/mL with a relative standard deviation of less than 6%. With dilution integrity up to 10-fold, the upper limit of quantification was extendable up to 1000 ng/mL. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method was successfully used to analyze human plasma samples for application in pharmacokinetic studies.  相似文献   

6.
In this study, a highly sensitive and robust method using an ultra-high-performance liquid chromatography-tandem mass spectrometry combined with solid-phase extraction and ultrasonic extraction for pretreatment and silica gel purification steps has been developed for determination of 21 natural and synthetic progestagens in river surface water and sediments, and influents, effluents, and sludge from municipal wastewater treatment plants, and flush water and feces from swine farms. For the various matrices considered, the optimized method showed satisfactory performance with recoveries of 70–129 % (except AD, 5α-DHP, DPT, HPC), the limits of quantification below 2.30 ng/L for liquid samples and 2.59 ng/g for solid samples (except AD), and good linearity and reproducibility. This developed method was successfully applied in the analysis of progestagens in environmental samples from Liuxi Reservoir, Xintang municipal wastewater treatment plant, and Shunfeng swine farm in South China. Six analytes were detected at trace levels in surface water, effluent, and sediment samples. Seven analytes (0.7 (HPA)–35.1 ng/L (DGT)) were found in the influent samples and three analytes (5.6 (DGT)–11.8 ng/g (5α-DHP)) in the dewatered sludge samples. Moreover, 13 analytes were detected in swine farm, with high concentrations ranging from 23.8 ng/L (ET) to 5,024 ng/L (P) in flush water, and from 20.0 ng/g (MPA) to 1952 ng/g (P) in feces.  相似文献   

7.
A simple and reliable method was developed to detect two basic synthetic dyes, rhodamine B (RB) and rhodamine 6G (R6G), in wastewater and surface water samples by high performance liquid chromatography with fluorescence detection (HPLC‐FLD). These dyes have been reported to be both mutagenic and carcinogenic in various organisms. The contents of these two dyes in water samples were extracted by Oasis HLB solid‐phase extraction (HLB‐SPE), and were then determined by an isocratic HPLC using an Atlantis® T3‐C18 column. Water samples at various pH conditions and the compositions of eluents for SPE were evaluated. The results indicate that the proposed method is precise and sensitive in analyzing these two basic synthetic dyes, and the limits of quantitation were 1.5 ng/L for RB and 0.3 ng/L for R6G in 100 mL of water samples. The recovery of analytes in spiked surface water and municipal wastewater treatment plant (WWTP) effluent samples ranged from 61 to 90% with the precision (RSD) ranging from 2 to 12%. The concentrations of analytes were detected in various water samples ranging from 0.7 to 81 ng/L.  相似文献   

8.
A liquid chromatography/electrospray ionization tandem mass spectrometric method for analyzing organophophorus flame retardants and plasticizers in drinking and environmental waters was developed. Five alkyl phosphates, three chlorinated alkyl phosphates, two aryl phosphate and triphenylphosphine oxide were selected for this study. These compounds were extracted from water samples by a hydrophilic polymeric solid-phase extraction cartridge. Accuracy and precision were evaluated analyzing 0.5 L of water samples spiked at concentrations of 10 and 100 ng/L for drinking water and at 300 and 1000 ng/L for river water. Except for trimethyl phosphate, analyte recoveries were better than 80%, and were not dependent on the type of aqueous matrix in which they were dissolved. At the spike levels considered, within-day precision was between 3 and 12% for tap water and between 4 and 14% for river water, and estimated method quantification limits ranged from 0.2 to 3.9 ng/L. A short survey conducted by analyzing some river water samples (River Tiber) ascertained the presence of ten organophosphorus compounds at concentration levels ranging from a few nanograms per liter to 323 ng/L for tris(2-butoxyethyl) phosphate.  相似文献   

9.
A new method for the determination of perchlorate in water and soil samples using on-line enrichment in a capillary zone electrophoresis-mass spectrometry is presented. The target analytes in the sample solutions were introduced into the capillary column by pressure-assisted electrokinetic injection (PAEKI) with the simultaneous application of -18 kV and +50 mbar external pressure to the sample vial at the capillary inlet for 4 min. The injected sample zone was flushed out with a running buffer and analyzed by a tandem mass spectrometer in a negative selected reaction monitoring mode. The influence of the matrix in both water and soil samples was eliminated by a clean-up step by passing the sample through Ba/Ag/H cartridges. The method showed good linearity in the dynamic range of 20 to 1000 ng/L, and achieved a detection limit of 18.7 ng/L for water samples and 3.3 ng/g for soil samples, respectively. The recovery of perchlorate in spiked samples, at three different levels, ranged over 79-127%. The method reproducibility was found to be 11% RSD for water samples and 7% RSD for soil samples. Perchlorate was found in 25 out of 28 water samples analyzed, with the levels ranging from 19.8 to 192 ng/L, and was not detected in the 10 soil samples analyzed.  相似文献   

10.
Because of their pronounced estrogenicity, resorcyclic acid lactones (RALs) are of concern in aqueous environments even at the low ng/L level. Therefore, we developed an accurate, precise and sensitive HPLC-MS/MS method to detect these mycotoxins in different aqueous environmental samples. The compounds investigated included zearalenone (ZON), alpha- and beta-zearalenol, zearalanone as well as alpha- and beta-zearalanol. The use of isotope labelled internal standards (in this case deuterated RAL-analogues) ensured an accurate quantification of the target analytes, independent of matrix compounds interfering with the analytes during ionisation and analyte losses occurring during sample preparation. Sample enrichment was carried out by solid-phase extraction (SPE) using Supelclean Envi-18 cartridges. Absolute method recoveries for all analytes ranged from 95 to 108%, 70 to 102%, and 76 to 109%, method detection limits from 0.5 to 2.1 ng/L, 0.4 to 1.1 ng/L, and 0.8 to 12.4 ng/L and precision from 3 to 14%, 2 to 13% and 4 to 16% in drainage water, river water and wastewater treatment plant (WWTP) effluent, respectively. The method was applied to verify the emission of RALs from a Fusarium graminearum infested crop field into the drainage system. Zearalenone was present in drainage water in concentrations up to 30 ng/L. So far, none of the other five investigated compounds have been detected.  相似文献   

11.
A fast and simple technique composed of dispersive liquid–liquid microextraction (DLLME) and online preconcentration MEKC with diode array detection was developed for the determination of four phenoxyacetic acids, 2,4,5‐trichlorophenoxyacetic acid, 2,4‐dichlorophenoxyacetic acid, 2,6‐dichlorophenoxyacetic acid, and 4‐chlorophenoxyacetic acid, in drinking water. The four phenoxyacetic acids were separated in reversed‐migration MEKC to the baseline. About 145‐fold increases in detection sensitivity were observed with online concentration strategy, compared with standard hydrodynamic injection (5 s at 25 mbar pressure). LODs ranged from 0.002 to 0.005 mg/L using only the online preconcentration procedures without any offline concentration of the extract. A DLLME procedure was used in combination with the proposed online preconcentration strategies, which achieved the determination of analytes at limits of quantification ranging from 0.2 to 0.5 μg/kg, which is far lower than the maximum residue limits established by China. The satisfactory recoveries obtained by DLMME spiked at two levels ranged from 67.2 to 99.4% with RSD <15%, making this proposed method suitable for the determination of phenoxyacetic acids in water samples.  相似文献   

12.
A new method is presented for the determination of 12 acidic pharmaceuticals (non-steroidal anti-inflammatory drugs and bezafibrate), including two metabolites from aqueous samples, together with triclosan as a personal care product. Ion-pair liquid chromatography (IP-LC) with electrospray ionisation tandem mass spectrometry (ESI-MS) in the negative ion mode was employed. The ion-pairing agent (tri-n-butylamine) increased the signal intensity for all acidic analytes and detection limits of 6-200 ng/L were obtained by multiple reaction monitoring. This allows analysis of wastewater samples by direct injection into the LC/MS system without the need for a preceding enrichment step. When combined with a solid-phase extraction (SPE) step, limits of quantification between 0.15 and 11 ng/L were obtained from 100-mL sample volumes, which is adequate for most applications. The occurrence of matrix effects was studied and standard addition was required for reliable quantification after SPE from wastewater. The method was finally applied to surface and wastewaters, with analyte concentrations ranging from below the detection limit up to 5.5 microg/L.  相似文献   

13.
A simple and rapid GC‐MS method has been developed for the screening and quantification of many illicit drugs and their metabolites in human urine by using automatic SPE and trimethylsilylation. Sixty illicit drugs, including parent drugs and their metabolites that are possibly abused in Korea, can be monitored by this method. Among them, 24 popularly abused illicit drugs were selected for quantification. Very delicate optimizations were carried out in SPE, trimethylsilylation derivatization, and GC/MS to enable such remarkable achievements. Trimethylsilylated analytes were well separated within 21 min by GC‐MS. In the validation results, the LOD of all the analytes were in the range of 2–75 ng/mL. The LOQ of the quantified analytes were in the range of 5–98 ng/mL. The linearity (r2) of the quantified analytes ranged 0.990–1.000 in each concentration range between 10 and 1000 ng/mL. The mean recoveries ranged from 62 to 126% at three different concentrations of each analyte. The inter‐day and inter‐person accuracies were within ?13.3~14.9%, and ?10.1~13.0%, respectively, and the inter‐day and inter‐person precisions were less than 12.9%. The method was reliable and efficient for the screening and quantification of abused illicit drugs in routine urine analysis.  相似文献   

14.
This paper describes a rapid and solvent-free method, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for the extraction of six commonly used synthetic polycyclic musks: galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI) from water samples prior to their determination using gas chromatography-mass spectrometry (GC-MS). The effects of various extraction parameters for the quantitative extraction of these analytes by MA-HS-SPME were systematically investigated and optimized. The analytes in a 20-mL water sample (in a 40-mL sample-vial containing 4 g of NaCl) were efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the system was microwave irradiated at 180 W for less than 4 min. The limits of detection (LODs) ranged from 0.05 to 0.1 ng/L, and the limits of quantification (LOQs) were less than 0.2 ng/L. A preliminary analysis of wastewater samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their concentration were determined to range from 1.2 to 37.3 ng/L with relative standard deviation (RSD) ranging from 2 to 6%. The results obtained using this approach are better than those from the conventional oil-bath HS-SPME.  相似文献   

15.
Dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography and mass spectrometry (GC-MS) was applied to the determination of six organophosphorous pesticides (OPPs) in water samples. The analytes included in this study were prophos, diazinon, chlorpyrifos methyl, methyl parathion, fenchlorphos and chlorpyrifos. Several extraction and dispersion solvents were tested for dispersive liquid-liquid microextraction of these analytes and the best results were obtained using chloroform as extraction solvent and 2-propanol as dispersion solvent. Calibration curves of the analytes in water samples were constructed in the concentration range from 100 to 1100 ng/L for prophos, diazinon and methyl parathion and in the range from 100 to 1000 ng/L for chlorpyrifos methyl, fenchlorphos and chlorpyrifos. Limits of detection (LODs) were in the range of 1.5-9.1 ng/L and limits of quantification (LOQs) were in the range of 5.1-30.3 ng/L, below the maximum admissible level for drinking water. Relative standard deviations (RSDs) were between 6.5 and 10.1% in the concentration range of 100-1000 ng/L. The relative recoveries (%RRs) of tap, well and irrigation water samples fortified at 800 ng/L were in the range of 46.1-129.4%, with a larger matrix effect being detected in tap water.  相似文献   

16.
A selective method using three-phase liquid-phase microextraction (LPME) in conjunction with LC-MS-MS was devised for the enantioselective determination of chloroquine and its n-dealkylated metabolites in plasma samples. After alkalinization of the samples, the analytes were extracted into n-octanol immobilized in the pores of a polypropylene hollow fiber membrane and back extracted into the acidic acceptor phase (0.1 M TFA) filled into the lumen of the hollow fiber. Following LPME, the analytes were resolved on a Chirobiotic V column using methanol/ACN/glacial acetic acid/diethylamine (90:10:0.5:0.5 by volume) as the mobile phase. The MS detection was carried out using multiple reaction monitoring with ESI in the positive ion mode. The optimized LPME method yielded extraction recoveries ranging from 28 to 66%. The method was linear over 5-500 ng/mL and precision (RSD) and accuracy (relative error) values were below 15% for all analytes. The developed method was applied to the determination of the analytes in rat plasma samples after oral administration of the racemic drug.  相似文献   

17.
A sensitive rapid resolution liquid chromatography-tandem mass spectrometry (RRLC-MS/MS) method, combined with solid-phase extraction, ultrasonic extraction and silica gel cartridge cleanup, was developed for 28 steroids including 4 estrogens (estrone (E1), 17β-estradiol (E2), 17α-ethynyl estradiol (EE2), diethylstilbestrol (DES)), 14 androgens (androsta-1,4-diene-3,17-dione (ADD), 17α-trenbolone, 17β-trenbolone, 4-androstene-3,17-dione, 19-nortestoserone, 17β-boldenone, 17α-boldenone, testosterone (T), epi-androsterone (EADR), methyltestosterone (MT), 4-hydroxy-androst-4-ene-17-dione (4-OHA), 5α-dihydrotestosterone (5α-DHT), androsterone (ADR), stanozolol (S)), 5 progestagens (progesterone (P), ethynyl testosterone (ET), 19-norethindrone, norgestrel, medroxyprogesterone (MP)), and 5 glucocorticoids (cortisol, cortisone, prednisone, prednisolone, dexamethasone) in surface water, wastewater and sludge samples. The recoveries of surface water, influents, effluents and sludge samples were 90.6-119.0% (except 5α-DHT was 143%), 44.0-200%, 60.7-123% and 62.6-138%, respectively. The method detection limits for the 28 analytes in surface water, influents, effluents and freeze-dried sludge samples were 0.01-0.24 ng/L, 0.02-1.44 ng/L, 0.01-0.49 ng/L and 0.08-2.06 ng/g, respectively. This method was applied in the determination of the residual steroidal hormones in two surface water of Danshui River, 12 wastewater and 8 sludge samples from two wastewater treatment plants (Meihu and Huiyang WWTPs) in Guangdong (China). Ten analytes were detected in surface water samples with concentrations ranging between 0.4 ng/L (17β-boldenone) and 55.3 ng/L (5α-DHT); twenty analytes in the wastewater samples with concentrations ranging between 0.3 ng/L (P) and 621 ng/L (5α-DHT); and 12 analytes in the sludge samples with concentrations ranging between 1.6 ng/g (E1) and 372 ng/g (EADR).  相似文献   

18.
建立了在线净化液相色谱-串联质谱同时测定牛奶中炔诺酮、17α-羟基孕酮、甲羟孕酮、乙酸甲地孕酮、孕酮和醋酸美伦孕酮6种孕激素的方法。本方法采用乙腈为提取溶剂提取目标化合物。提取液经在线净化柱Cyclone-P净化,经Phenyl-Hexyl色谱柱分离,流动相采用0.5%(v/v)甲酸水溶液-乙腈,在电喷雾正离子模式下以多反应监测(MRM)方式测定,内标法定量。方法在0.1~50 μg/L范围内呈线性关系,线性相关系数均大于0.999。6种分析物的测定低限为0.5 μg/kg,在牛奶中3个水平的添加回收率在90.8%~107.5%之间,相对标准偏差在6.3%~11.8%之间。该方法快速简便,灵敏度高,选择性好,可用于牛奶样品中孕激素的快速定性定量分析。  相似文献   

19.
The quantification of steroid hormones of individual zebrafish (Danio rerio) provides perspective to understand endogenous hormone function. A UPLC–TOF–MS method was developed to provide a reproducible, sensitive, and efficient assay to determine the concentration of steroid hormones, including cortisol, testosterone, androstenedione, 11-deoxycortisol, 11-deoxycorticosterone, and 17-hydroxyprogesterone in whole-body homogenates of each zebrafish. Solid-phase extraction was used to sample matrix clean-up and acquired a recovery from 89.7% to 107.9%. The analytes were separated on an Aquity BEH C18 column using gradient elution. Mass spectrometric analysis was performed by single reaction monitoring (SRM) using positive electrospray ionization mode. The total running time was 6 min, which was greatly shortened compared with a previously reported method. The developed method exhibited excellent linearity for all the analytes, with regression coefficients higher than 0.99. The limit of detection varied between 0.1 and 0.5 ng/L and the limit of quantification was 0.5–1.7 ng/L for all analytes. The precision of the method was assessed on replicate measurements and was found to be in the ranges of 1.9 % to 6.6% and 4.3% to 8.6%, for intra- and inter-day analysis, respectively. This method was validated according to FDA guidance and applied to determine steroid hormone levels in the tissue homogenate of zebrafish acutely treated with caffeine and ethanol.  相似文献   

20.
A membrane-assisted solvent extraction (MASE) method is presented for the extraction of several non-ionic organophosphorus chemicals from wastewaters samples followed by LC-MS/MS determination. The method was developed for a variety of chlorinated phosphates (trichloroethyl, tichloropropyl) and non-chlorinated phosphates (triphenyl, tributyl) used as flame retardants and for plasticizers such as triethylhexyl and tris-butoxyethyl phosphate. Parameters such as extracting solvent, sample volume and ionic strength, extraction temperature and time were optimized. The final method provides good quantification limits (1-25 ng L(-1)) and linearity (R2>0.9978). Method precision was also good at high concentrations (5% mean RSD at the 500 ng L(-1) level) but decreased at lower concentrations (20% mean RSD at the 20 ng L(-1) level). MASE yields lower matrix effects than SPE in a successive LC-MS/MS analysis of these compounds, avoiding the need for standard addition for quantification. When applied to wastewater samples comparable results were obtained using either MASE with internal standard calibration or SPE with standard addition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号