共查询到20条相似文献,搜索用时 46 毫秒
1.
2.
3.
4.
5.
6.
《光学学报》2020,(4)
基于朗奇-泰伯效应及莫尔条纹技术,利用发散光和不等周期光栅的焦距测量方法被用于小口径长焦透镜的焦距测量。将一块曲率半径存在加工误差的平凹长焦透镜作为待测透镜进行焦距测量。在未知透镜真实曲率半径的情况下,首先计算待测透镜曲率半径误差对焦距检测精度的影响,并确定透镜在整个检测系统中的位置,然后进行透镜焦距实际测量,分别计算多组测量焦距值。通过对比发现,在未知待测透镜曲率半径的情况下,检测焦距的重复性、稳定性均一致,所测焦距均为33200~33270mm,且重复性精度高于±0.055%,测量精度优于焦深的1/5。结果充分说明,所提方法对小口径长焦透镜的焦距检测是可靠、有效的。 相似文献
7.
8.
长焦距测量的Talbot-Moiré法是研究热点,目前很多方法虽然都是基于Talbot现象和Moiré技术,但基本原理和实验方案各不相同,因此焦距计算公式也不相同。基于透镜位相变换作用,利用Talbot效应和Moiré条纹,通过图像处理的方法获得条纹的斜率变化,根据焦距与莫尔条纹斜率之间的关系求得透镜焦距。由于长焦透镜的焦距相对于被测透镜厚度大得多,完全可以看作是薄透镜对光束的变换,可用薄透镜对球面波的变换作用来近似表示其对高斯光束的变换。因此,该方法测量长焦透镜焦距对于高斯光束与非高斯光束焦距测量结果无差别,均适用。最后全面分析了该测量方法的误差及精度极限。在影响测量精度的各个误差因素中,光栅节距误差对焦距测量的影响最为显著。 相似文献
9.
10.
11.
Guided-Wave Two-Dimensional Acousto-Optic Scanner Using Proton-Exchanged Lithium Niobate Waveguide 总被引:1,自引:0,他引:1
Two-dimensional scanning of a 0.6328 mum guided-light beam has been realized using noncolinear acousto-optic (AO) coplanar Bragg diffraction together with colinear AO guided-mode to substrate radiation-mode conversion in a Z-cut Xpropagation LiNbO3 proton-exchanged (PE) waveguide. The two surface acoustic (SAW) waves utilized are at the center frequencies of 500 and 200 MHz, propagating in the Y and X axes, respectively. Two-dimensional scanning of approximately 720 resolvable light beam spots, namely, 18 40 (horizontal vertical) scanning, has been demonstrated using a light beam of 1.0 mm aperture. The total number of resolvable beam spots can be greatly increased from 720 by simply utilizing SAW transducers of larger bandwidth and a light beam of greater aperture. It should also be possible to significantly increase the diffraction efficiency from 3 % by optimizing the parameters of the PE waveguide and the SAWs. 相似文献
12.
A simple technique of pulse compression, based on the linear chirp compensation of self-phase modulation (SPM) spectra in dispersion shifted fibers, is demonstrated. The optimization procedure is carried out, for a short span of a single-mode fiber, using a parabolic law, which describes the behavior of the squared output pulse width versus the pump peak power in the case of Gaussian pulses. The experimental results give a minimum pulse duration of 233 fs, which is in good agreement with the model. Shorter and coherent pulses, down to 90 fs, have been obtained by inserting an interference filter at the optical output. 相似文献
13.
S. G. Nedel’ko M. A. Krysyuk A. L. Apanasenko L. N. Lymarenko Z. T. Moroz 《Journal of Applied Spectroscopy》1997,64(1):55-61
Results of a study of the effect of γ-radiation on the spectral luminescence properties of cadmium tungstate crystals doped
with silver, bismuth, and molybdenum cations are presented. Spectral characteristics of the nondnnnoped crystals are briefly
described. Absorption and photo and X-ray luminescence spectra of the crystals taken before and after exposure to γ-radiation
(5.5·104 Gy) are compared. It is found that the spectral characteristics of the crystals doped with silver, bismuth, and molybdenum
cations do not change markedly after the exposure. The relation between the type of impurity-induced defects, individual characteristics
of the impurity cations, and the character of the effect of γ-radiation on the spectral luminescence properties of impure
crystals is analyzed (preliminarily).
Translated from Zhurnal Prikladnoi Spektroskopii, Vol. 64, No. 1, pp. 55–60, January–February, 1997. 相似文献
14.
The Shanghai Synchrotron Radiation Facility(SSRF)booster ring,a full energy injector for the storage ring,is deigned to accelerate the electron beam energy from 150MeV to 3.5GeV that demands high extraction efficiency at the extraction energy with low beam loss rate when electrons are ramping.Closed orbit distortion(COD)caused by bending magnet field uniformity errors which affects the machine performance harmfully could be effectively reduced by bending magnet location sorting.Considering the affections of random errors in measurement,both ideal sorting and realistic sorting are studied based on measured bending magnet field uniformity errors and one reasonable combination of bending magnets which can reduce the horizontal COD by a factor of 5is given as the final installation sequence of the booster bending magnets in this paper. 相似文献
15.
16.
We measure the waveform and phase curves of short optical pulses before and after transmission over different lengths of fibers by use of the pulse analyzer with the frequency-resolved optical gating (FROG),and numerically simulate pulse evolution under the experimental conditions.The nonlinear coefficient of the fiber is given by comparing the experimental results with the numerical ones.Difference between the experiment and numerical simulation is analyzed. 相似文献
17.
Resonance scattering of elastic spherical shell and cylindrical shell while the surrounding fluid medium has absorption is studied. The normal mode solution derived using exact elastic theory and the separation of variables is still applicable. However, the scattering form function has to be modified for the absorbing medium, otherwise the unreasonable result would be obtained. The backscattering form function in the absorbing medium is redefined, and the form function of elastic spherical and cylindrical shell with vacuum or solid matter filled is calculated in various absorption conditions. The results show that the absorption of surrounding fluid leads to notable attenuation of the coincidence resonances in the mid-frequency, but it has a little influence on the low-frequency resonance scattering induced by the filler inside the shell. 相似文献
18.
A versatile and low-cost single-beam self-referenced phase-sensitive surface plasmon resonance(SPR)sensing system with ultra-high resolution performance is presented.The system exhibits a root-mean-square phase fluctuation of ±0.0028.over a period of 45 min.i.e.a resolution of±5.2×10-9 refractive index units.The enhanced performance has been achieved through the incorporation of three design elements:a true single-beam configuration enabling complete self-referencing so that only the phase change associated with SPR gets detected,a differential measurement scheme to eliminate spurious signals not related to the sensor response,and the elimination of retardation drifts by incorporating temperature stabilization in the liquid crystal phase modulato .Our design should bring the detection sensitivity of non-labeling SPR biosensing closer to that achievable by conventional fluorescence-based techniques. 相似文献
19.
Ta2O5 films are prepared on BK7 substrates with conventional electron beam evaporation deposition.The effects of SiO2 protective layers and annealing on the laser-induced damage threshold (LIDT) of the films are investigated.The results show that SiO2 protective layers exert little influence on the electric field intensity(EFI)distribution,microstructure and microdefect density but increase the absorption slightly.Annealing iS effective on decreasing the microdefect density and the absorption of the films.Both SiO2 protective layers and annealing are beneficial to the damage resistance of the films and the latter is more effective to improve the LIDT.Moreover,the maximal LIDT of Ta2O5 films is achieved by the combination of SiO2 protective layers and annealing. 相似文献
20.
Yepeng Guan 《中国光学快报(英文版)》2008,6(6)
Gray cross correlation matching technique is adopted to extract candidate matches with gray cross correla- tion coefficients less than some certain range of maximal correlation coefficient called multi-peak candidate matches. Multi-peak candidates are extracted corresponding to three closest feature points at first. The corresponding multi-peak candidate matches are used to construct the model polygon. Correspondence is determined based on the local geometric relations between the three feature points and the multi-peak candidates. The disparity test and the global consistency checkout are applied to eliminate the remaining ambiguous matches that are not removed by the local geometric relational test. Experimental results show that the proposed algorithm is feasible and accurate. 相似文献