首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
In this paper we proposed a reverse high performance liquid chromatography method for the simultaneous determination of three N-methylcarbamates (NMCs) named carbofuran, carbaryl and methiocarb, using the post-column chemiluminescence (CL) detection with the luminol reaction. This method is based on the enhancing effect of these analytes on the CL emission generated by the oxidation of luminol with potassium permanganate in alkaline medium. The separation was reached in less than 14 min using a C18 column and an isocratic binary mobile phase consisting of acetonitrile:water (50:50, v/v) pumped at a flow rate of 1 mL min−1. CL reagents (luminol and KMnO4) were incorporated by means of a peristaltic pump and were firstly mixed using a three-way connector. Then this stream was mixed with the eluate using another three-way connector just before reaching the detection cell. The optimization of variables affecting the CL reaction (reaction medium, concentration, flow rate of reagents and distance between both connectors) were optimized by means of experimental designs. Ethiofencarb, a NMC which has nowadays fallen into disuse was used as internal standard. For the analysis of theses pesticides in real water samples a pre-treatment step consisting of solid phase extraction (SPE) was conducted in order to reach sensitivity levels below the legal maximum concentration permitted. In the case of vegetable sample, SPE was used for matrix cleaning purpose.  相似文献   

3.
Although the mechanisms of many chemiluminescence (CL) reactions have been intensively studied, no general model has been suggested to rationalize the efficiency of these transformations. To contribute to this task, we report here quantum yields for some well‐characterized CL reactions, concentrating on recent reports of efficient transformations. Initially, a short review on the most important general CL mechanisms is given, including unimolecular peroxide decomposition, electrogenerated CL, as well as the intermolecular and intramolecular catalyzed decomposition of peroxides. Thereafter, quantum yield values for several CL transformations are compiled, including the unimolecular decomposition of 1,2‐dioxetanes and 1,2‐dioxetanones, the catalyzed decomposition of appropriate peroxides and the induced decomposition of properly substituted 1,2‐dioxetane derivatives. Finally, some representative examples of quantum yields for complex CL transformations, like luminol oxidation and the peroxyoxalate reaction, in different experimental conditions are given. This quantum yield compilation indicates that CL transformations involving electron transfer steps can occur with high efficiency in general only if the electron transfer is of intramolecular nature, with the intermolecular processes being commonly inefficient. A notable exception to this general rule is the peroxyoxalate reaction which, also constituting an example of an intermolecular electron transfer system, possesses very high quantum yields.  相似文献   

4.
The present review presents the state of the art of the developments, key strategies and analytical applications of chemiluminescence detection coupled to CE (CE‐CL). Different parts considering the most common CL systems have been included, such as the tris(2,2′‐bipyridine)ruthenium(II) system, the luminol and derivatives reaction, the peroxyoxalate CL or direct oxidations. New advances in homemade configurations and applications in different fields such as clinical, pharmaceutical, environmental and food analysis have been included. The focus is on studies which appeared from 2000 to the end of 2009.  相似文献   

5.
4-(N,N-Dimethylaminosulphonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F), presented as a fluorogenic labelling reagent for amines and amino acids, is preferred for peroxyoxalate chemiluminescence (PO-CL) detection in high performance liquid chromatography. Amino acids and epinephrine derivatized with DBD-F were separated on a reversed phase column and detected at the femtomole level by the PO-CL detection system.  相似文献   

6.
Fu Z  Li Z  Xie H  Li T  Li C 《Electrophoresis》2010,31(19):3342-3345
Luminol-type compounds can be used as chemiluminescent (CL) derivatization reagents for amines, carboxylic acids and protein. Copper chelate diperiodatocuprate(III) (K5[Cu(HIO6)2], DPC) was synthesized by complexation of copper at trivalent oxidation state and periodate in a strong basic medium. It was found that DPC can greatly enhance the reaction between luminol-type compounds and H2O2 to produce very strong CL emission. Based on this fact, a rapid CE method combined with high-sensitive end-column CL detection was established to simultaneously analyze luminol and N-(4-aminobutyl)-N-ethylisoluminol (ABEI) with wide concentration range of 3.0-300 nmol/L in 5 min. The RSDs of the signal intensity and the migration time were less than 3.9 and 7.0% for a standard sample containing 100 nmol/L luminol and ABEI (n=5), respectively. The investigation implies that DPC is a promising sensitizer for CE-CL detection of a great variety of biomolecules and drugs in biological samples after derivatization using luminol derivatives.  相似文献   

7.
Yang W  Zhang Z  Deng W 《Talanta》2003,59(5):951-958
A novel chemiluminescence (CL) detection scheme has been developed for detecting underivatized amino acids following capillary electrophoresis (CE) separation. This detection was based on the inhibitory effect of amino acids on the CL reaction between luminol and BrO in alkaline aqueous solution. Detection of amino acids was accomplished with a borate-based background electrolyte at pH 9.2. The luminol was used as a component of the separation carrier electrolyte. Parameters affecting CE-CL separation and detection, such as the pH value, the concentration of electrolyte and CL reagent on the resolution were optimized. The relative standard deviation for the analysis of amino acids was less than 1.5% for the migration time and 4% for the peak height. The mass limits of detection were from 7 to 144 fmol for the 7 amino acids. This method has been applied of 7 amino acids in amino acid injection.  相似文献   

8.
Quinones are a class of compounds of substantial toxicological and pharmacological interest. An ultrasensitive and highly selective chemiluminescence (CL) method was newly developed for the determination of quinones based on the utility of photochemically initiated luminol CL. The method involved ultraviolet (UV) irradiation of quinones to generate reactive oxygen species (ROS) through the unique photosensitization reaction accompanied with the photolytical generation of 3,6-dihydroxyphthalic acid (DHPA) from quinones. The photoproducts were detected by luminol CL reaction. Interestingly, it was noticed that DHPA had enhancement effect for the luminol CL. The generation of the enhancer (DHPA) in association with the oxidant (ROS) in the photochemical reaction greatly increases the sensitivity and selectivity of the proposed luminol CL method. In order to elucidate the type of ROS produced by the photosensitizaion reaction in relation to the proposed CL reaction, we investigated the quenching effect of selective ROS scavengers in the luminol CL. Although several ROS were generated, superoxide anion was the most effective ROS for the generated CL. Moreover, the enhancement mechanism of DHPA for luminol CL was confirmed. The enhancement was found to be through the formation of stabilized semiquinone anion radical that provided long-lived CL. The generation of the semiquinone radical was confirmed by electron spin resonance technique. Furthermore, we developed an HPLC method with on-line photochemical reaction followed by the proposed CL detection for the determination of four quinones. A luminol analogue, L-012, was used for its high sensitivity. The detection limits for quinones obtained with the proposed method (S/N = 3) were in the range 1.5–24 fmol that were 10–1000 times more sensitive compared with the previous methods. Finally, the developed HPLC-CL system was successfully applied for the determination of quinones in airborne particulate samples collected at Nagasaki city.  相似文献   

9.
液相色谱-化学发光检测法的最新进展   总被引:2,自引:0,他引:2  
周延秀  朱果逸 《色谱》1997,15(4):296-300
评述了近年来液相色谱-化学发光检测法的最新进展,参考文献从1992年到1995年。内容涉及各类化学发光反应同液相色谱体系的耦合方式,仪器设计,多种无机、有机、生物大分子、生物活性物质及药物的分析方法及其在环境、生物医学科学和生命科学、临床化学及药物化学中的应用和发展方向。  相似文献   

10.
A new method based on high‐performance liquid chromatography (HPLC) coupled with on‐line gold nanoparticle‐catalyzed luminol chemiluminescence (CL) detection was developed for the simultaneous quantitation of catecholamines in rat brain. In the present CL system, gold nanoparticles were produced by the on‐line reaction of H2O2, NaHCO3?Na2CO3 (buffer solution of luminol) and HAuCl4. Norepinephrine (NE), epinephrine (EP) and dopamine (DA) could strongly enhance the CL signal of the on‐line gold nanoparticle‐catalyzed luminol system. The UV?visible absorption spectra and transmission electron microscopy studies were carried out, and the CL enhancement mechanism was proposed. Catecholamines promoted the on‐line formation of more gold nanoparticles, which better catalyzed the luminol–H2O2 CL reaction. The good separation of NE, EP and DA was achieved with isocratic elution using a mixture of methanol and 0.2% aqueous phosphoric acid (5:95, v/v) within 8.5 min. Under the optimized conditions, the detection limits, defined as a signal‐to‐noise ratio of 3, were in the range of 1.32–1.90 ng/mL, corresponding to 26.4?38.0 pg for 20 μL sample injection. The recoveries of catecholamines added to rat brain sample were >94.6%, with the precisions <5.5%. The validated HPLC?CL method was successfully applied to determine NE and DA in rat brain without prior sample purification. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
液相色谱化学发光检测法的新进展   总被引:4,自引:0,他引:4  
武竟存  章竹君 《分析化学》1994,22(4):396-405
本文评述了近年来液相色谱化学发光检测法的新进展,内容涉及各类化学发光发反应,生物发光反应和电致化学发光反应同色谱体系的偶合方式,仪器设计,多种无机,有机,生物大分子和生物活性物质的分析方法及其在环境,生物医学科学和生命科学中的应用和发展方向。引用文献168篇。  相似文献   

12.
The peroxyoxalate chemiluminescence(CL) detection method for the evaluation of the CL intensity of malondialdehyde(MDA) condensates with seven 2-thiobarbituric acid derivatives is described. The method consists of a flow injection technique together with a CL detection system using bis(2,4,6-trichlorophenyl) oxalate(TCPO) and hydrogen peroxide as chemiluminogenic reagents. Linear correlations between CL intensity and concentration are obtained for pmol levels of condensates. Among the condensates, 1,3-diethyl-2-thiobarbituric acid(DETBA)-MDA shows the largest CL intensity. High performance liquid chromatography (HPLC)/CL detection of DETBA-MDA and 1,3-diphenyl-2-thiobarbituric acid(DPTBA)-MDA using a mixture of TCPO and hydrogen peroxide in acetonitrile as a postcolumn reagent solution is also described. The detection limits for DETBA-MDA and DPTBA-MDA are 20 and 200 fmol, respectively, per 20 microL injection at a signal-to-noise ratio of 2. This HPLC/CL detection system was applied to the determination of MDA in rat brains by using DETBA as a fluorescent derivatizing reagent.  相似文献   

13.
This paper reviews the latest developments and analytical applications of chemiluminescence detection coupled to capillary electrophoresis (CE-CL). Different sections considering the most common CL systems have been included, such as the tris(2,2?-bipyridine)ruthenium(II) system, the luminol and acridinium derivative reactions, the peroxyoxalate CL or direct oxidations. Improvements in instrumental designs, new strategies for improving both resolution and sensitivity, and applications in different fields such as clinical, pharmaceutical, environmental and food analysis have been included. This review covers the literature from 2010 to 2015.  相似文献   

14.
A flow-injection chemiluminescence (CL) method has been proposed for sensitive determination of arsenate, germanate, phosphate and silicate, after separation by ion chromatography (IC). The post-column detection system involved formation of heteropoly acid in a H2SO4 medium before the CL reaction with luminol in an NaOH medium. For separation, heteropoly acid formation and the CL detection reaction, pH requirements were not compatible. When present as a heteropoly acid complex with molybdenum(VI), ger- manium(IV) and silicon(IV) caused CL emission from oxidation of luminol, and such a CL oxidation of luminol was observed analogously for arsenic(V) and phosphorus(V) but with the addition of metavanadate ion to the acid solution of molybdate. Good sensitivity for the three analytes arsenic(V), ger- manium(IV) and phosphorus(V) could be given by a single set of reagent conditions, chosen carefully. Another set was suitable for determining phosphorus(V) and silicon(IV). The minimum detectable concentrations of arsenic(V), germanium(IV), phosphorus(V) and silicon(IV) were 10, 50, 1 and 10 μg l−1, respectively. Linear calibrations for arsenic(V), germanium(IV), phosphorus(V) and silicon(IV) were established over the respective concentration ranges of 10–1000, 50–25000, 1–1000 and 50–1 μg l−1. The proposed IC–CL method was successfully applied to analyses of a seaweed reference material, rice wine and water samples.  相似文献   

15.
Horseradish peroxidase (HRP) encapsulated in liposomes was directly detected by using luminol chemiluminescence (CL) with H2O2 without lysis of liposomes. At a low concentration of H2O2, the initial rate of HRP-catalyzed luminol CL in liposomes was slower than that of HRP-catalyzed luminol CL in a lipid-free bulk solution. The decrease in the initial rate of the CL reaction in liposomes was due to the membrane permeation of luminol and H2O2. At a high concentration of H2O2, the initial rate of the CL reaction in liposomes was the same as that in a lipid-free bulk solution. The CL measurement conditions in both a lipid-free bulk solution and in liposomes were optimized in the concentrations of luminol and H2O2 by measuring the CL response curves, in which only one peak appeared and the CL intensity was maximal. The CL intensity observed in HRP-catalyzed luminol CL in liposomes was a factor of seven greater than that observed in a lipid-free bulk solution. The CL intensity was dependent on the amount of HRP-encapsulated liposomes used. The detection limit in the direct detection of HRP encapsulated in liposomes was sensitive by a factor of 3 compared with that in HRP-catalyzed luminol CL in a lipid-free bulk solution.  相似文献   

16.
In this work, using benzo(a)pyrene (BaP) as marker, the analytical merits of on-line flow-injection cloud-point extraction (FI CPE), including preconcentration factor, extraction efficiency, sample throughput, and analysis time were evaluated by use of peroxyoxalate chemiluminescence (CL) detection. Moreover, by detailed discussion of several preconcentration conditions for traditional and on-line FI CPE the advantages of on-line FI CPE became conspicuously apparent. When coupled with separation techniques such as high-performance liquid chromatography (HPLC) or capillary electrophoresis (CE), on-line FI CPE–CL has much potential for analysis of low concentrations of polycyclic aromatic hydrocarbons (PAH) in environmental samples.  相似文献   

17.
鲁米诺化学发光分析法研究进展   总被引:1,自引:0,他引:1  
邵晓东  李瑛 《化学研究》2010,21(1):102-112
从化学发光反应机理和应用进展两个方面对鲁米诺-过氧化氢、鲁米诺-铁氰化钾、鲁米诺-碘化物、鲁米诺-高锰酸钾和鲁米诺-溶解氧等化学发光体系进行了综述;指出鲁米诺化学发光体系是应用最为广泛的一类化学发光体系,同时对鲁米诺化学发光分析法的发展方向进行了展望.  相似文献   

18.
Eighteen kinds of pyrimido[5,4-d]pyrimidines together with several commercially available fluorescent compounds such as perylene, Rhodamine B, etc., were evaluated as the reagents for a peroxyoxalate chemiluminescence (CL) detection system by using a flow injection method. The peroxyoxalate CL reaction employed consists of bis(2,4,6-trichlorophenyl)oxalate, hydrogen peroxide, triethylamine, and a fluorophore. Under the conditions used, 2,6-bis[di-(2-hydroxyethyl)amino]-4,8- dipiperidinopyrimido[5,4-d]pyrimidine (Dipyridamole) and 2,4,6,8-tetrathiomorpholinopyrimido[5,4-d]pyrimidine (1i) gave very intense chemiluminescence intensities which were larger than those of any other commercially available fluorescent compounds tested (e.g., 10 times larger than that of perylene).  相似文献   

19.
Homogentisic acid gamma-lactone (HAL) chemiluminescence (CL) was applied to the determination of horseradish peroxidase (HRP) encapsulated in liposomes. HRP was detected after the lysis of HRP-trapped liposomes with Triton X-100. CL response rate, detection limit and linear range of calibration curve for HRP in HAL CL were compared with those in piodophenol (p-IP)-enhanced luminol CL. Maximal light emission in HAL CL appeared more rapidly compared to that in p-IP enhanced luminol CL, thus resulting in remarkable reduction of CL measurement time. The detection limit for HRP in HAL CL was the same as that in p-IP-enhanced luminol CL. The linear range of calibration curve for HRP in HAL CL was improved by a factor of 50 compared with that in p-IP-enhanced luminol CL. From these results, it was found that HAL CL were superior to p-IP-enhanced luminol CL for the determination of HRP encapsulated in liposomes.  相似文献   

20.
In this work the catalytic role of unsupported gold nanoparticles on the luminol–hydrazine reaction is investigated. Gold nanoparticles catalyze the reaction of hydrazine and dissolved oxygen to generate hydrogen peroxide and also catalyze the oxidation of luminol by the produced hydrogen peroxide. The result is an intense chemiluminescence (CL) due to the excited 3-aminophthalate anion. In the absence of gold nanoparticles no detectable CL was observed by the reaction of luminol and hydrazine unless an external oxidant is present in the system. The size effect of gold nanoparticles on the CL intensity was investigated. The most intensive CL signals were obtained with 15-nm gold nanoparticles. UV–vis spectra and transmission electron microscopy studies were used to investigate the CL mechanism. The luminol and hydroxide ion concentration, gold nanoparticles size and flow rate were optimized. The proposed method was successfully applied to the determination of hydrazine in boiler feed water samples. Between 0.1 and 30 μM of hydrazine could be determined with a detection limit of 30 nM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号