首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this paper, we report a new method to determine the effective atomic number, Z eff, of composite materials for Compton effect in the γ-ray region 280–1115 keV based on the theoretically obtained Klein–Nishina scattering cross-sections in the angular range 50°–100° as well as a method to experimentally measure differential incoherent (Compton) scattering cross-sections in this angular range. The method was employed to evaluate Z eff for different inorganic compounds containing elements in the range Z = 1–56, at three scattering angles 60°, 80° and 100° at three incident gamma energies 279.1 keV, 661.6 keV and 1115.5 keV and we have verified this method to be an appropriate method. Interestingly, the Z eff values so obtained for the inorganic compounds were found to be equal to the total number of electrons present in the sample as given by the atomic number of the elements constituting the sample in accordance with the chemical formula of the sample. This was the case at all the three energies.  相似文献   

2.
In this work, we have made an effort to determine whether the effective atomic numbers of H-, C-, N- and O-based composite materials would indeed remain a constant over the energy grid of 280–1200 keV wherein incoherent scattering dominates their interaction with photons. For this purpose, the differential incoherent scattering cross-sections of Be, C, Mg, Al, Ca and Ti were measured for three scattering angles 60°, 80° and 100° at 279.1, 661.6 and 1115.5 keV using which an expression for the effective atomic number was derived. The differential incoherent scattering cross-sections of the composite materials of interest measured at these three angles in the same set-up and substituted in this expression would yield their effective atomic number at the three energies. Results obtained in this manner for bakelite, nylon, epoxy, teflon, perspex and some sugars, fatty acids as well as amino acids agreed to within 2% of some of the other available values. It was also observed that for each of these samples, Z eff was almost a constant at the three energies which unambiguously justified the conclusions drawn by other authors earlier [Manjunathaguru and Umesh, J. Phys. B: At. Mol. Opt. Phys. 39, 3969 (2006); Manohara et al,Nucl. Instrum. Methods B266, 3906 (2008); Manohara et al Phys. Med. Biol. 53, M377 (2008)] based on total interaction cross-sections in the energy grid of interest.  相似文献   

3.
4.
The K shell absorption jump ratios, jump factors, effective atomic numbers, and electron densities were derived from the measured total mass attenuation coefficient using an energy dispersive X‐ray fluorescence spectrometer for Gd2O3, Gd2(CO3)3H2O, Gd2(C2O4)3H2O, and Gd2(SO4)3 compounds. The total mass attenuation coefficients were measured in the X‐ray energy range from 39.52 to 57.14 keV in a transmission geometry utilizing the Kα2, Kα1, Kβ1, and Kβ2 X‐rays from different secondary source targets excited by the 59.54‐keV photons from an Am‐241 annular source and detected by a Si(Li) detector with a resolution of 160 eV at 5.9 keV. The energy gap, ionization energy, electron affinity, and global electrophilicity parameters of oxide, sulfate, oxalate, and carbonate ions were calculated using density functional theory (B3LYP). The experimental results are discussed based on these parameters. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
Monte Carlo simulations, FLUKA and Geant4, were performed to study mass attenuation for various types of soil at 59.5, 356.5, 661.6, 1173.2 and 1332.5 keV photon energies. Appreciable variations are noted for all parameters by changing the photon energy and the chemical composition of the sample. The simulations parameters were compared with experimental data and the XCOM program. The simulations show that the calculated mass attenuation coefficient values were closer to experimental values better than those obtained theoretically using the XCOM database for the same soil samples. The results indicate that Geant4 and FLUKA can be applied to estimate mass attenuation for various biological materials at different energies. The Monte Carlo method may be employed to make additional calculations on the photon attenuation characteristics of different soil samples collected from other places.  相似文献   

6.
The main goal of this present study is focused on testing the applicability of Geant4 electromagnetic models for studying mass attenuations coefficients for different types of composite materials at 59.5, 80, 356, 661.6, 1173.2 and 1332.5 keV photon energies. The simulated results of mass attenuation coefficients were compared with the experimental and theoretical XCOM data for the same samples and a good agreement has been observed. The results indicate that this process can be followed to determine the data on the attenuation of gamma rays with the several energies in different materials. The modeling for photon interaction parameters was standard for any type of composite samples. The Geant4 code can be utilized for gamma ray attenuation coefficients for the sample at different energies, which may sometimes be impractical by experiment investigation.  相似文献   

7.
Molar extinction coefficients of aqueous solutions of some organic compounds, viz. formamide (CH3NO),N-methylformamide (C2H5NO),NN-dimethylformamide (C3H7NO),NN-dimethylacetamide (C4H9NO), 1,4-dioxane (C4H8O24), succinimide (C4H5NO2) and solutions of acetamide (C2H5NO) and benzoic acid (C7H6O2) in 1,4-dioxane (C4H8O2) have been determined by narrow beam γ-ray transmission method at 81, 356, 511, 662, 1173 and 1332 keV. The experimental values of mass attenuation coefficients of these compounds have been used to calculate effective atomic numbers and electron densities. The additivity rule earlier used for aqueous solution has been extended to non-aqueous (1,4-dioxane) solutions.  相似文献   

8.
The total mass attenuation coefficients for elements Cr, Co and Fe and compounds CrCl2, CrCl3, Cr2(SO4)3K2SO4·24H2O, CoO, CoCl2, Co(CH3COO)2, FePO4, FeCl3·6H2O, Fe(SO4)2NH4·12H2O were measured at different energies between 4.508 and 14.142 keV using secondary excitation method. Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr were chosen as secondary exciters. 59.5 keV γ-rays emitted from a 241Am annular source were used to excite a secondary exciter and Kα(K-L3, L2) lines emitted by the secondary exciter were counted by a Si(Li) detector with a resolution of 160 eV at 5.9 keV. It was observed that mixture rule method is not a suitable method for determination of the mass attenuation coefficients of compounds, especially at an energy that is near the absorption edge. The obtained values were compared with theoretical values.   相似文献   

9.
The total mass attenuation coefficients for element Fe and compounds FeF3, Fe2O3, FeCl2·4H2O, FeCl32NH4Cl·H2O were measured at different energies between 4.508-17.443 keV range by using secondary excitation method. Ti, V, Cr, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Y, Zr, Nb, Mo were chosen as secondary exciter. 59.5 keV gamma rays emitted from an 241Am annular source were used to excite secondary exciter and Kα(K-L3, L2) lines emitted of secondary exciter were counted by a Si(Li) detector with a resolution of 160 eV at 5.9 keV. It was observed that mixture rule method is not a suitable method for determination of the mass attenuation coefficients of compounds, especially at energy that is near the absorption edge. Obtained values were compared with theoretical values.  相似文献   

10.
Thermally stimulated luminescence (TSL) of undoped and doped CaSO4 with activators such as Cu and Mn has been investigated. The polycrystalline samples of undoped and doped CaSO4 are prepared by the melting method. The formation of CaSO4 compound is confirmed by X-ray diffraction and Fourier transform infrared studies. Scanning electron microscopic studies of CaSO4 are also carried out.

The TSL glow curves of undoped CaSO4, Cu- and Mn-doped CaSO4 are studied. Comparison of the thermoluminescence (TL) intensity of the most intensive glow peak of Cu-doped CaSO4 compound with that of undoped CaSO4 shows that addition of Cu impurity in CaSO4 compound enhances the TL intensity by about four times. However, the addition of Mn impurity to undoped CaSO4 increases the TL intensity by about three times when compared with that of undoped CaSO4. The TL-dose dependence of all three samples was studied and was observed to be almost linear in the studied range of irradiation time. Among the samples studied, namely undoped CaSO4 and Cu- and Mn-doped CaSO4, Cu-doped CaSO4 is found to be the most sensitive. The trap parameters, namely order of kinetics (b), activation energy (E) and frequency factor (s) associated with the most intensive glow peaks of CaSO4:Mn, CaSO4:Cu and CaSO4 phosphors were determined using the glow curve shape (Chen's) method.  相似文献   

11.
The objective of this work is focused on development of a classification tool for identifying soil texture based on photon attenuation interaction atomic cross‐section data. The total mass attenuation coefficients (μ/ρ) and the atomic cross sections (σa) of soils with different textures have been calculated for total photon interactions in a wide energy range (1 keV to 100 GeV). The values of these parameters have been found to change with soil composition in low energies (1–100 keV), whereas their behavior has been found to be similar at all energies. Slight differences were observed in σa in the energy range of 0.01 to 10 MeV and more pronounced ones from 10 MeV to 100 GeV. Regarding μ/ρ, only small differences were observed among soils for all the energy range investigated. Differences between μ/ρ and σa considering different proportions of Fe2O3 and SiO2 were also observed. The reported data should be useful for studying soil texture according photo attenuation. The results of this work can stimulate research for all types of soil texture. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
This work evaluates the dosimetric properties of crystals of CaSO4 doped with unusual elements, such as europium (Eu) and silver (Ag), including their nanoparticle forms, after the incorporation of glass or Teflon and compares them with well-known thermoluminescent dosimeters (TLD). X-ray diffraction analyses showed that samples of doped CaSO4 exhibit only a single phase corresponding to the crystal structure of anhydrite. Optical spectroscopy confirmed the presence of Eu3+ in the crystal matrix and a luminescent gain due the presence of silver nanoparticles. The composites showed thermoluminescent emission glow curves, with a single peak centered at approximately 200 °C for pellets with Teflon and at 230 °C for pellets with glass. The dosimeters based on calcium sulfate doped with europium and silver nanoparticles provided the most intense thermoluminescent (TL) emission of the composites studied. In comparison with commercial TLD, such as LiF:Mg,Ti and CaSO4:Dy, the CaSO4:Eu,Ag(NP)+glass produced in this work presented similar low detection limits and higher sensitivity. The new methods for the preparation of dosimeters and the incorporation of glass are shown to be viable because all of the samples presented a linear, reproducible and first order kinetic TL emission.  相似文献   

13.
Spectroscopic properties of Er3+:CBS (CdSO4+B2O3 and R2SO4+CdSO4+B2O3, R2SO4=Li2SO4.H2O, Na2SO4, K2SO4 and Gd2(SO4)3.8H2O) glasses are reported. The assigned energy level data of Er3+(4f 11) in these glasses are analysed in terms of a parametrized model Hamiltonian. The standard deviations of the data fits are between 39 and 47 cm−1 so that the energy level schemes of the Er3+(4f 11) ions in borosulphate (CBS) glasses are reasonably well reproduced. Radiative properties for the fluorescent levels of Er3+:CBS glasses are determined by using the Judd-Ofelt theory. The potential laser transitions are identified with the help of predicted radiative properties which are compared and discussed with similar results.  相似文献   

14.
Radiation interaction parameters such as total stopping power, projected range (longitudinal and lateral) straggling, mass attenuation coefficient, effective atomic number (Zeff) and electron density (Neff) of some shielding materials were investigated for photon and heavy charged particle interactions. The ranges, stragglings and mass attenuation coefficients were calculated for the high-density polyethylene(HDPE), borated polyethylene (BPE), brick (common silica), concrete (regular), wood, water, stainless steel (304), aluminum (alloy 6061-O), lead and bismuth using SRIM Monte Carlo software and WinXCom program. In addition, effective atomic numbers (Zeff) and electron densities (Neff) of HDPE, BPE, brick (common silica), concrete (regular), wood, water, stainless steel (304) and aluminum (alloy 6061-O) were calculated in the energy region 10?keV–100?MeV using mass stopping powers and mass attenuation coefficients. Two different methods namely direct and interpolation procedures were used to calculate Zeff for comparison and significant differences were determined between the methods. Variations of the ranges, longitudinal and lateral stragglings of water, concrete and stainless steel (304) were compared with each other in the continuous kinetic energy region and discussed with respect to their Zeffs. Moreover, energy absorption buildup factors (EABF) and exposure buildup factors (EBF) of the materials were determined for gamma rays as well and were compared with each other for different photon energies and different mfps in the photon energy region 0.015–15?MeV.  相似文献   

15.
The mass attenuation coefficients (μm) have been measured for undecylic acid (C11H22O2), lauric acid (C12H24O2), tridecylic acid (C13H26O2), myristic acid (C14H28O2), pentadecylic acid (C15H30O2) and palmitic acid (C16H32O2) using 57Co, 133Ba, 137Cs, 60Co and 22Na emitted γ radiation with energies 122, 356, 511, 662, 1170, 1275 and 1330 keV, respectively. The accurate values of the effective atomic number (Zeff), atomic cross-section (σt,), electronic cross-section (σe) and the effective electron density (Neff) have great significance in radiation protection and dosimetry. These quantities were obtained by utilizing experimentally measured values of mass attenuation coefficients (μm). A NaI(Tl) scintillation detector with 8.2% (at 662 keV) resolution was used for detecting of attenuated γ-photons. The variation in Zeff and Neff of fatty acids with energy is discussed. The experimental and theoretical results are in good agreement within 2% deviation.  相似文献   

16.
在不同温度不同水分子环境中对聚环氧琥珀酸(PESA)阻垢剂与硬石膏晶体主要生长面(001)的相互作用进行了分子动力学模拟. 结果表明:在323~343 K时,不同水分子数中PESA都能有效阻止CaSO4垢的生长;同一水分子数中,不同温度下的结合能比较接近. 体系的结合能主要由库仑能变(包括离子键)提供,硬石膏晶体中的Ca原子与PESA中的羰基O原子发生了成键作用. PESA中羧基O原子和水分子中H原子之间存在氢键作用,而范德华相互作用有助于该PESA-H2O-CaCO3相互作用体系的形成. O(PESA的羧基)-H(H2O)、O(CaSO4)-H(H2O)和O(CaSO4)-H(PESA)原子对的径向分布函数表明,溶剂分子对聚环氧琥珀酸阻硫酸钙的阻垢性能有影响.  相似文献   

17.
In this study, the absorption experiments which are an application area in XRS are discussed. The effect on the absorption parameters of the pressure applied to make pellet powder samples was investigated. The mass attenuation coefficients ( μ m ), mean free paths and half-value layers of samples prepared at different pressures were experimentally determined. C6H10O5, VF4, CaO and Y2O3 samples were pressed at 1.91, 3.82, 5.72 and 7.63 tons/cm2. A variable energy x-ray source from Amersham (AMC.2084) was used in order to irradiate the samples at energies 13.39, 19.63, 24.90, 32.06, 36.39, 44.48, 51.70 and 59.54 keV. The photon intensities were measured by using an HPGe detector with a resolution of 182 eV at 5.9 keV. The theoretical radiation absorption parameters were calculated by WinXCOM program. The calculated values were compared with the experimental values. Good agreement has been observed within experimental uncertainties for low pellet pressure. The obtained results show that the radiation absorption parameters change with the amount of pressure applied to the sample.  相似文献   

18.
19.
20.
Abstract

LiNaSO4: Eu is a recently discovered thermoluminescence dosimetry (TLD) phosphor which is more sensitive than the widely used CaSO4:Dy. In this paper results are reported on TL glow curves, TL emission spectra and PL photoluminescence. These measurements help to understand the role of impurity and the mechanism of thermoluminescence in this phosphor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号